Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 32(5): 1228-1239, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38477107

RESUMO

PURPOSE: The purpose of this study was to determine whether unrestricted calipered kinematic alignment (KA), coupled with a medial-stabilised (MS) implant system, can reproduce the patient's constitutional alignment as per the arithmetic hip-knee-ankle (aHKA) and improve clinical outcomes. METHODS: One-hundred and ninety-three patients received total knee arthroplasty by the senior author. To determine whether the constitutional alignment was achieved, the postoperative hip-knee-ankle (HKA) alignment was compared against the aHKA. Range of motion (ROM) was determined preoperative and postoperatively at 6 months and 2 years by measuring the active flexion and extension. Patient-Reported Outcomes Measures (PROMs) including Oxford Knee Score (OKS), Knee Injury and Osteoarthritis Outcome Score (KOOS), Forgotten Joint Score (FJS) and Visual Analogue Scale for Satisfaction were also completed. The Sports and Recreation component of KOOS was used to assess the patient's ability to return to sports and daily activities. RESULTS: There was a strong correlation between postoperative HKA and aHKA (r = 0.7, p < 0.05). There was a significant improvement in both extension and flexion seen from as early as 6 months postoperatively, with a mean flexion of 123° ± 11° and extension of 1° ± 3° at 2 years. PROMs had significant improvements with a mean score of 42.8 ± 6.0 for the OKS and all KOOS subscales consisting of Symptoms (88.0 ± 11.7), Pain (91.4 ± 11.6), Activities of Daily Living (91.1 ± 12.4), Sports (76.8 ± 22.1) and Quality of Life (83.0 ± 19.1). The FJS had significant improvements from 6 months to 2 years of 19.9 (p < 0.05), with a mean score of 69.2 ± 26.6 at 2 years. Ninety-three percent (180 patients) were classified as 'satisfied' at the 2-year timepoint. The KOOS Sports component was completed by 64% (124 patients), whereby the mean age was younger than the noncompliant patients (67.7 ± 9.4 vs. 71.7 ± 8.2 years). CONCLUSION: Unrestricted calipered KA can result in an alignment that closely resembles the patient's constitutional alignment, as per the aHKA. This resulted in improved knee ROM and patient satisfaction, as well as assisting younger patients to return to sports and daily activities. LEVEL OF EVIDENCE: Level IV.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Satisfação do Paciente , Amplitude de Movimento Articular , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Artroplastia do Joelho/métodos , Idoso , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia , Medidas de Resultados Relatados pelo Paciente , Resultado do Tratamento , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Articulação do Tornozelo/cirurgia , Articulação do Tornozelo/fisiopatologia , Articulação do Quadril/cirurgia , Articulação do Quadril/fisiopatologia , Prótese do Joelho
2.
Arthroplast Today ; 24: 101250, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37920544

RESUMO

Background: Although various total knee arthroplasty (TKA) implant designs are widely used, the ideal TKA design is yet to be agreed upon. Although the benefits of cruciate-retaining (CR) TKA and medial stabilized (MS) TKA have been reported in literature, the early clinical outcomes of an MS TKA with CR inserts have not been reported. This study aims to report on the patient-reported clinical and radiological outcomes of MS-TKA combined with a CR insert. Methods: A prospective single-surgeon series evaluated the clinical- and patient-reported outcomes of 115 patients implanted with GMK Sphere CR. Patient outcomes were assessed with the Oxford Knee Score, Knee Injury and Osteoarthritis Outcome Scores (KOOS), Forgotten Joint Score, and Visual Analogue Scale for Satisfaction. Radiological assessment for alignment along with active flexion and extension were also assessed. Results: Improvement in all scores was observed between the preoperative and 1-year follow-up timepoints, with statistical significance seen for Oxford Knee Score as well as KOOS Symptoms, Pain, Sport, quality of life, and activities of daily living subscales. The mean active flexion between the preoperative and both postoperative timepoints at 6 months and 1 year was also statistically significant (P = .021 and P = .001). Conclusions: MS-TKA with a CR insert can facilitate symptom relief and improve overall function of the knee after surgery. Both the patient and clinical outcomes were comparable to 1-year outcomes utilizing other MS-TKA designs and were superior to those at 1-year follow-up following implantation of CR-TKA. Most notability, the KOOS symptoms and sports score were higher for the MS-TKA with a CR insert than for an MS-TKA design.

3.
Arthroplast Today ; 22: 101157, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37521743

RESUMO

Background: Collared femoral stems have been considered to reduce the risk of early subsidence over collarless stems. However, with advances in material technology, new surface treatments have been introduced into cementless stem design to enhance primary fixation and long-term stability. This study aims to analyze the early migration behaviors of a proximally coated collarless femoral stem and cementless acetabular component and compare the outcomes with commercially available cementless stems and acetabular cups. Methods: A total of 24 patients (25 hips) undergoing total hip arthroplasty were recruited and followed up for 2 years. All patients received a Masterloc femoral stem (Medacta International SA, Castel San Pietro, Switzerland) and an Mpact acetabular component (Medacta International SA, Castel San Pietro, Switzerland) with tantalum beads embedded during the operation. Radiographs for radiostereometric analysis were taken immediately postsurgery, 6-months, 1-year, and 2-years postoperatively. Results: The median condition number for this study was 59. The median stem subsidence was -0.08 mm (-2.47 to 0.40) at 2 years. The median cup subsidence was -0.03 mm (-0.38 to 0.57) at 2 years. The migration of the Masterloc stem was less than that of other cementless collarless, as well as collared stems, as reported in literature. Conclusions: This study has demonstrated the high stability and fixation provided with the use of a collarless cementless stem. The subsidence seen in both this cementless femoral stem and acetabular cup at 2 years postoperative was below the range reported in literature for cementless collarless and collared stems.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA