Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(7)2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38610876

RESUMO

Background and Objectives: Antiseptics have been suggested to enhance the outcomes of non-surgical periodontal treatment (NSPT). Among these, povidone-iodine (PVP-iodine) was reported to significantly reduce periodontal pocket depths (PPDs). The aim of this study was to systematically re-assess the existing literature regarding the potential benefit of using PVP-iodine in step II periodontal therapy. Material and Methods: The scientific literature was systematically searched across electronic libraries for randomized controlled trials employing PVP-iodine during NSPT through to September 2023, using search items related to PVP-iodine and periodontitis. The selection process was performed by two independent reviewers. The primary outcomes were reductions in periodontal probing depth (PPD) and clinical attachment level (CAL). When reasonable, a meta-analysis of the included studies was performed. Results: Initially, 799 records were identified. After abstract and title screening and fulltext revision, 15 RCTs were included. The data from eight studies were merged in meta-analyses. The use of PVP-iodine had no significant effect on PPD reduction at 6 months (means [standard deviation]: -0.12 mm [-0.33; 0.09]) but it did at 12 months (-0.29 mm [-0.56; -0.02]). CAL was significantly better at 6 (-0.42 mm [-0.64; -0.20]) and 12 months (-0.39 mm [-0.66; -0.11]). Conclusions: PVP-iodine rinsing during NSPT may slightly improve patients' PPD and CAL.

2.
Oral Health Prev Dent ; 21(1): 153-162, 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37195331

RESUMO

PURPOSE: This study investigated the effect of toothbrush bristle stiffness and brushing force on the cleaning efficacy in vitro. MATERIALS AND METHODS: Eighty bovine dentin samples were allocated to eight groups (n=10). Two custom-made toothbrushes of different bristle stiffness (soft and medium) were tested at four different brushing forces (1, 2, 3 and 4 N). Dentin samples were stained in black tea and brushed (60 strokes/min) for a total of 25 min in a brushing machine with an abrasive solution (RDA 67). Photographs were taken after 2 and 25 min of brushing time. Cleaning efficacy was measured planimetrically. RESULTS: After 2 min of brushing, the soft-bristle toothbrush did not cause statistically significantly different cleaning efficacy at different brushing forces, while the medium-bristle toothbrush cleaned statistically significantly less efficaceously only at 1 N. Comparing the two different toothbrushes, higher cleaning efficacy was observed only at 1 N for the soft-bristle brush. At 25 min brushing time, the soft-bristle cleaned statistically significantly better at 4 N compared to 1 N and 2 N and at 3 N compared to 1 N. Using the medium-bristle, cleaning efficacy increased with increasing brushing force. After 25 min of brushing, no statistically significant difference was observed between the two different toothbrushes. CONCLUSION: Irrespective the brushing force, the use of a soft or medium toothbrush results in comparable cleaning efficacy. At 2 min brushing time, increasing the brushing force does not increase the cleaning efficacy.


Assuntos
Acidente Vascular Cerebral , Escovação Dentária , Humanos , Animais , Bovinos , Chá , Desenho de Equipamento
3.
Acta Odontol Scand ; 80(6): 465-469, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35147472

RESUMO

OBJECTIVE: To investigate the effect of toothbrush bristles end configuration on the abrasive dentine wear at different brushing forces. MATERIAL AND METHODS: One hundred and sixty bovine dentine samples were randomized into eight groups (n = 20). Groups (1 to 4) were brushed with tapered-end bristles at 1-, 2-, 3-, and 4-N brushing forces, respectively. Groups (5 to 8) were brushed with round-end bristles with the same brushing forces. The brushing sequence was carried out using an abrasive slurry (RDA = 121) for 25 min. Profiles were recorded using a contact profilometer. Mean and standard deviation were calculated for the abrasive dentine wear in each group. Two-way ANOVA was used to locate any significance. The significance values were corrected after Tukey (α = 0.05). RESULTS: Brushing with tapered-end bristles resulted in statistically significantly less abrasive dentine wear than round-end bristles regardless of the applied brushing force (1 N: 4.4 ± 1.5 vs. 7.7 ± 2.0 µm; 2 N: 7.7 ± 2.1 vs. 12.2 ± 2.7 µm; 3 N: 11.3 ± 2.6 vs. 19.4 ± 3.7 µm; 4 N: 11.2 ± 2.1 vs. 25.3 ± 4.8 µm). The interaction between bristle configuration and brushing force was statistically significantly (p < 0.001). CONCLUSION: Tapered-end toothbrushes might be a safer choice for patients, especially when showing signs of non-carious cervical lesion. However, other toothbrush properties should also be considered.


Assuntos
Abrasão Dentária , Escovação Dentária , Animais , Bovinos , Análise de Variância , Dentina , Desenho de Equipamento , Abrasão Dentária/etiologia , Escovação Dentária/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA