Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
J Interv Card Electrophysiol ; 66(9): 1971-1978, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36856972

RESUMO

BACKGROUND: Left atrial appendage occlusion (LAAO) may be a viable option for stroke prevention in patients with non-valvular atrial fibrillation and a contraindication for oral anticoagulation. No evidence evaluating the safety of this procedure in patients with a cardiac implantable electronic device (CIED) exists. The aim of this study was to evaluate whether CIED function is affected by LAAO and to explore LAAO procedural characteristics and complications in patients with a CIED. METHODS: This single-center cohort study included consecutive patients scheduled for percutaneous LAAO. Patients with a CIED prior to LAAO were selected and compared to the patients without CIED, concerning procedural characteristics and peri-procedural complications. In the group of patients with CIEDs, essential pacemaker integrity parameters were compared before and after the procedure to detect possible micro and macro lead displacements. RESULTS: Thirty-one patients with CIED were scheduled for LAAO (age 73.7 ± 5.4 years, 65% males, CHA2DS2-VASc 4.3 ± 1.5, and HAS-BLED 3.3 ± 1.0). The 245 patients without CIED were younger, and HAS-BLED-score was slightly lower (69.4 ± 8.2 years, p < 0.001; 2.8 ± 1.0, p = 0.022). Patients without CIED more frequently underwent LAAO combined with catheter ablation (p = 0.002). All other procedural characteristics were comparable between both groups. No visible lead displacement was observed on chest X-ray after LAAO. Additionally, no differences in impedance, threshold, or intracardiac sensing in various CIED lead locations were found prior versus post LAAO. CONCLUSION: This study supports the feasibility and safety of LAAO in patients with a CIED.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Masculino , Humanos , Idoso , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Estudos de Coortes , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
2.
Neth Heart J ; 31(4): 150-156, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36720801

RESUMO

BACKGROUND: In patients with stable coronary artery disease (CAD), revascularisation decisions are based mainly on the visual grading of the severity of coronary stenosis on invasive coronary angiography (ICA). However, invasive fractional flow reserve (FFR) is the current standard to determine the haemodynamic significance of coronary stenosis. Non-invasive and less-invasive imaging techniques such as computed-tomography-derived FFR (FFR-CT) and angiography-derived FFR (QFR) combine both anatomical and functional information in complex algorithms to calculate FFR. TRIAL DESIGN: The iCORONARY trial is a prospective, multicentre, non-inferiority randomised controlled trial (RCT) with a blinded endpoint evaluation. It investigates the costs, effects and outcomes of different diagnostic strategies to evaluate the presence of CAD and the need for revascularisation in patients with stable angina pectoris who undergo coronary computed tomography angiography. Those with a Coronary Artery Disease-Reporting and Data System (CAD-RADS) score between 0-2 and 5 will be included in a prospective registry, whereas patients with CAD-RADS 3 or 4A will be enrolled in the RCT. The RCT consists of three randomised groups: (1) FFR-CT-guided strategy, (2) QFR-guided strategy or (3) standard of care including ICA and invasive pressure measurements for all intermediate stenoses. The primary endpoint will be the occurrence of major adverse cardiac events (death, myocardial infarction and repeat revascularisation) at 1 year. CLINICALTRIALS: gov-identifier: NCT04939207. CONCLUSION: The iCORONARY trial will assess whether a strategy of FFR-CT or QFR is non-inferior to invasive angiography to guide the need for revascularisation in patients with stable CAD. Non-inferiority to the standard of care implies that these techniques are attractive, less-invasive alternatives to current diagnostic pathways.

3.
Neth Heart J ; 30(3): 160-171, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34910279

RESUMO

PURPOSE: Invasive fractional flow reserve (FFR), the reference standard for identifying significant coronary artery disease (CAD), can be estimated non-invasively by computed tomography-derived fractional flow reserve (CT-FFR). Commercially available off-site CT-FFR showed improved diagnostic accuracy compared to coronary computed tomography angiography (CCTA) alone. However, the diagnostic performance of this lumped-parameter on-site method is unknown. The aim of this cross-sectional study was to determine the diagnostic accuracy of on-site CT-FFR in patients with suspected CAD. METHODS: A total of 61 patients underwent CCTA and invasive coronary angiography with FFR measured in 88 vessels. Significant CAD was defined as FFR and CT-FFR below 0.80. CCTA with stenosis above 50% was regarded as significant CAD. The diagnostic performance of both CT-FFR and CCTA was assessed using invasive FFR as the reference standard. RESULTS: Of the 88 vessels included in the analysis, 34 had an FFR of ≤ 0.80. On a per-vessel basis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 91.2%, 81.4%, 93.6%, 75.6% and 85.2% for CT-FFR and were 94.1%, 68.5%, 94.9%, 65.3% and 78.4% for CCTA. The area under the receiver operating characteristic curve was 0.91 and 0.85 for CT-FFR and CCTA, respectively, on a per-vessel basis. CONCLUSION: On-site non-invasive FFR derived from CCTA improves diagnostic accuracy compared to CCTA without additional testing and has the potential to be integrated in the current clinical work-up for diagnosing stable CAD.

4.
Neth Heart J ; 29(12): 632-642, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34724147

RESUMO

INTRODUCTION: Despite considerable advances in the last decade, major adverse events remain a concern after transcatheter aortic valve implantation (TAVI). The aim of this study was to provide a detailed overview of their underlying causes and contributing factors in order to identify key domains for quality improvement. METHODS: This observational, prospective registry included all patients undergoing TAVI between 31 December 2015 and 1 January 2020 at the St. Antonius Hospital in Nieuwegein and the University Medical Centre in Utrecht. Outcomes of interest were all-cause mortality, stroke, major bleeding, life-threatening or disabling bleeding, major vascular complications, myocardial infarction, severe acute kidney injury and conduction disturbances requiring permanent pacemaker implantation within 30 days after TAVI, according to the Valve Academic Research Consortium­2 criteria. RESULTS: Of the 1250 patients who underwent TAVI in the evaluated period, 146 (11.7%) developed a major complication. In 54 (4.3%) patients a thromboembolic event occurred, leading to stroke in 36 (2.9%), myocardial infarction in 13 (1.0%) and lower limb ischaemia in 11 (0.9%). Major bleeding occurred in 65 (5.2%) patients, most frequently consisting of acute cardiac tamponade (n = 25; 2.0%) and major access-site bleeding (n = 21; 1.7%). Most complications occurred within 1 day of the procedure. Within 30 days a total of 54 (4.3%) patients died, the cause being directly TAVI-related in 30 (2.4%). Of the patients who died from causes that were not directly TAVI-related, 14 (1.1%) had multiple hospital-acquired complications. CONCLUSION: A variety of underlying mechanisms and causes form a wide spectrum of major threats affecting early safety in 11.7% of patients undergoing TAVI in a contemporary cohort of real-world patients.

5.
Neth Heart J ; 29(12): 654-661, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34495448

RESUMO

OBJECTIVES: The aim of this study is to evaluate device size selection in patients within the borderline annulus size range undergoing transcatheter aortic valve replacement (TAVR) and to assess if pre-procedural patient-specific computer simulation will lead to the selection of a different device size than standard of care. BACKGROUND: In TAVR, appropriate device sizing is imperative. In borderline annulus size cases no standardised technique for tailored device size selection is currently available. Pre-procedural patient-specific computer simulation can be used, predicting the risk for paravalvular leakage (PVL) and need for permanent pacemaker implantation (PPI). METHODS: In this multicentre retrospective study, 140 patients in the borderline annulus size range were included. Hereafter, device size selection was left to the discretion of the operator. After TAVR, in 24 of the 140 patients, patient-specific computer simulation calculated the most appropriate device size expected to give the lowest risk for PVL and need for PPI. In these 24 patients, device size selection based on patient-specific computer simulation was compared with standard-of-care device size selection relying on a standardised matrix (Medtronic). RESULTS: In a significant proportion of the 140 patients (26.4%) a different device size than recommended by the matrix was implanted. In 10 of the 24 patients (41.7%) in whom a computer simulation was performed, a different device size was recommended than by means of the matrix. CONCLUSIONS: Device size selection in patients within the borderline annulus size range is still ambiguous. In these patients, patient-specific computer simulation is feasible and can contribute to a more tailored device size selection.

6.
Neth Heart J ; 29(11): 595-603, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34415550

RESUMO

BACKGROUND: Symptomatic tricuspid regurgitation (TR) is increasingly prevalent and impairs quality of life and survival, despite medical treatment. Transcatheter tricuspid valve repair (TTVR) has recently become available as a treatment option for patients not eligible for tricuspid valve surgery. In this study we describe the early experience with TTVR in the Netherlands. METHODS: All consecutive patients scheduled for TTVR in two tertiary hospitals were included in the current study. Patients were symptomatic and had severe functional TR. TTVR was performed either with the MitraClip (off-label use) or dedicated TriClip delivery system and device. Procedural success was defined as achievement of clip implantation, TR reduction ≥ 1 grade and no need for re-do surgical or transcatheter intervention. Clinical improvement was evaluated after 4 weeks. RESULTS: Twenty-one patients (median age 78 years, 33% male, 95% New York Heart Association class ≥ 3, 100% history of atrial fibrillation) underwent TTVR. Procedural success was achieved in 16 patients, of whom 15 reported symptomatic improvement (New York Heart Association class 1 or 2). There was no in-hospital mortality and no major complications occurred. Baseline glomerular filtration rate and TR coaptation gap size were associated with procedural success. CONCLUSION: The current study showed that TTVR seems a promising treatment option for patients with severe functional TR deemed high risk for surgery. Successful TR reduction is most likely in patients with limited coaptation gap size and strongly determines clinical benefit. Adequate patient selection and timing of treatment seem essential for an optimal patient outcome.

7.
Sci Rep ; 11(1): 6748, 2021 03 24.
Artigo em Inglês | MEDLINE | ID: mdl-33762686

RESUMO

Multiple non-invasive tests are performed to diagnose coronary artery disease (CAD), but all are limited to either anatomical or functional assessments. Computed tomography derived Fractional Flow Reserve (CT-FFR) based on patient-specific lumped parameter models is a new test combining both characteristics simulating invasive FFR. This study aims to evaluate the added value of CT-FFR over other non-invasive tests to diagnose CAD. Patients with clinical suspicion of angina pectoris between 2010 and 2011 were included in this cross-sectional study. All underwent stress electrocardiography (X-ECG), SPECT, CT coronary angiography (CCTA) and CT-FFR. Invasive coronary angiography (ICA) and FFR were used as reference standard. Five models mimicking the clinical workflow were fitted and the area under receiver operating characteristic (AUROC) curve was used for comparison. 44% of the patients included in the analysis had a FFR of ≤ 0.80. The basic model including pre-test-likelihood and X-ECG had an AUROC of 0.79. The SPECT-strategy had an AUROC of 0.90 (p = 0.008), CCTA-strategy of 0.88 (p < 0.001), 0.93 when adding CT-FFR (p = 0.40) compared to 0.94 when combining CCTA and SPECT. This study shows adding on-site CT-FFR based on patient-specific lumped parameter models leads to an increased AUROC compared to the basic model. It improves the diagnostic work-up beyond SPECT or CCTA and is non-inferior to the combined strategy of SPECT and CCTA in the diagnosis of hemodynamically relevant CAD.


Assuntos
Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Reserva Fracionada de Fluxo Miocárdico , Hemodinâmica , Idoso , Tomada de Decisão Clínica , Angiografia por Tomografia Computadorizada/métodos , Gerenciamento Clínico , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Fluxo de Trabalho
8.
Int J Cardiol ; 330: 179-185, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33582196

RESUMO

BACKGROUND: Immunosuppressive therapy in active cardiac sarcoidosis (CS) might prevent potential life-threatening complications. Infliximab (IFX) is a tumor necrosis factor alpha monoclonal antibody proven to be effective in refractory extracardiac sarcoidosis. It is sparsely used in CS, because of its association with worsening heart failure in prior studies. The goal of this study is to assess the effectiveness and safety of IFX in CS. METHODS AND RESULTS: A retrospective, single center cohort study was performed in sarcoidosis patients treated with IFX based on a cardiac indication between January 2016 and March 2019. Patients received IFX intravenously at a dose of 5 mg/kg at week 0, 2, and subsequently every 4 weeks. After every six months, treatment response was evaluated within the multidisciplinary team using FDG-PET/CT, transthoracic echocardiography, biomarkers and device interrogation reports. Responder analysis definitions were based on; dosage of immunosuppressive drugs, improvement in functional class, left ventricular ejection fraction (LVEF) and SUVmax. Twenty-two patients were included (mean age 51.0 SD10.0 years, male 68.2%) with a mean follow-up of 18.9 months (6 to 44 months) of whom 18 (82%) were classified as responders. Median SUVmax on FDG-PET/CT decreased from SUVmax 5.2 [3.7-8.4] to 2.3 [1.4-2.3], p = 0.015. The target-to-background ratio decreased from 3.2 [2.1-5.1] to 1.0 [0.7-2.4], p = 0.002. The median left ventricular (LV) ejection fraction increased from 45.0% [34.0-60.0] to 55.0% [41.0-60.0], p = 0.02. The majority of patients (73%) experienced no side effects and no patients had worsening of heart failure. CONCLUSION: In this pilot study, patients with refractory CS treated with infliximab, on top of standard of care, had a reduction in inflammation on FDG-PET/CT and an improvement in LV function, without serious adverse events.


Assuntos
Cardiomiopatias , Sarcoidose , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/tratamento farmacológico , Estudos de Coortes , Fluordesoxiglucose F18 , Humanos , Infliximab , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Sarcoidose/diagnóstico por imagem , Sarcoidose/tratamento farmacológico , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda
9.
Int J Cardiovasc Imaging ; 36(8): 1497-1505, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32350704

RESUMO

Pulmonary hypertension (PH) is a well-recognised complication of sarcoidosis. Non-invasive diagnosis is challenging due to limited accuracy of echocardiography in interstitial lung disease. This study evaluates the value of echocardiographic PH probability for diagnosing PH in pulmonary sarcoidosis. All consecutive patients between August 2015 and November 2018 were prospectively screened for PH, and classified as low, intermediate or high PH probability. Patients with intermediate or high PH probability were referred for right heart catheterisation. PH was defined as a mean pulmonary artery pressure of ≥ 25 mm Hg. Additional data on pulmonary function and chest-CT was collected. Of all 479 patients, PH was present in 17 and absent in 19 patients. Six patients refused right heart catheterisation. PH was present in 33% and 75% of patients with intermediate and high PH probability respectively (n = 36). TRV max was measurable in 46% of all patients. Measurability did not correlate with FVC% predicted or presence of significant fibrosis. In intermediate and high PH probability, TRV max < 2.9 m/s successfully ruled out PH whereas a TRV max > 3.4 confirmed PH in all patients. If TRV max was absent or in between 2.9 and 3.4, secondary echocardiographic signs were not able to improve the diagnostic accuracy. PH is unlikely in patients with a TRV max < 2.9 m/s on echocardiography, whereas PH is highly suspected in a TRV max > 3.4 m/s. Discrimination is challenging if the TRV max is between 2.9-3.4 m/s or absent. Additional secondary signs do not improve discrimination. Decision making for further investigations should be made by an expert team.


Assuntos
Ecocardiografia , Hipertensão Pulmonar/diagnóstico por imagem , Sarcoidose Pulmonar/diagnóstico por imagem , Adulto , Idoso , Pressão Arterial , Função do Átrio Direito , Progressão da Doença , Feminino , Humanos , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Fatores de Risco , Sarcoidose Pulmonar/complicações , Sarcoidose Pulmonar/fisiopatologia , Função Ventricular Direita
10.
Neth Heart J ; 27(12): 613-620, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31187455

RESUMO

AIMS: Oral anticoagulation (OAC) reduces the ischaemic stroke risk in patients with atrial fibrillation (AF), but in turn leads to an increased risk of adverse bleeding events. Alternatively, left atrial appendage closure (LAAC) using a mechanical device might overcome these bleeding complications. However, evidence regarding LAAC in patients at high bleeding risk is scarce. This study evaluates the clinical features of AF patients with previous bleeding that underwent LAAC. METHODS: In this retrospective cohort study patients with previous major bleeding or a bleeding predisposition scheduled for transcatheter LAAC were included. The frequency and type of previous bleeding events and prevalence of bleeding and ischaemic stroke during follow-up were evaluated. RESULTS: A total of 73 patients (58% male, age 72.1 ± 7.2 years; CHA2DS2-VASc 4.5 [3.0-5.0]; HAS-BLED 4.0 [3.0-4.0]; 46% paroxysmal AF) were included. Previous bleeding occurred from intracranial (n = 50, 69%), gastro-intestinal (n = 13, 18%) or multiple (n = 16, 22%) foci. After OAC discontinuation due to bleeding, 19% suffered subsequent stroke. LAAC was successful in 96% of patients. During a median of almost 3 years' follow-up recurrent major bleeding occurred in 4 patients (5.5%) despite OAC discontinuation in 93.2%. A total of 6 ischaemic strokes were observed, resulting in an annualised stroke rate of 2.9% compared to a calculated expected stroke rate of 6.7%. CONCLUSIONS: Percutaneous LAAC may provide an alternative strategy to long-term OAC therapy in AF patients with a high bleeding risk. During follow-up, both ischaemic stroke and recurrent bleeding rates were lower than expected based on the CHA2DS2-VASc and HAS-BLED scores respectively.

11.
Neth Heart J ; 25(12): 669-674, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28887807

RESUMO

INTRODUCTION: Structural heart interventions are guided by transoesophageal or intracardiac echocardiography (TEE/ICE). MicroTEE, developed for paediatric purposes, is smaller and therefore less invasive and traumatic, avoiding the need for general anaesthesia. We aimed to show feasibility of procedural guidance by comparing image quality of microTEE with standard TEE and ICE during adult transcatheter interventions, and assess the accuracy in obtaining left atrial appendage (LAA) measurements between the microTEE probe and standard TEE. METHODS AND RESULTS: We prospectively included 49 patients (20 women, 64 ± 18 years). Intraprocedural images were obtained by using the microTEE probe and standard (2D and 3D) TEE (LAA closure, MitraClip implantation) or ICE (interatrial communication closure, transseptal puncture for left atrial ablation). Two echocardiographers independently assessed image quality from 1 (excellent) to 4 (poor) and performed LAA measurements. Use of microTEE was not related to significant discomfort. Image quality obtained with the microTEE probe was lower than with standard TEE (2 [1-2] vs. 1 [1-2]; p = 0.04) and comparable with ICE images (2 [1-2] vs. 2 [1-2], p = 0.13). MicroTEE showed a wider field of view than ICE. LAA measurements on images obtained by microTEE were strongly associated with standard TEE. CONCLUSIONS: MicroTEE seems feasible for guidance during transcatheter heart interventions in adults. MicroTEE imaging offers a wider field of view than ICE, and its accuracy is comparable with TEE. In transcatheter interventions performed under conscious sedation, microTEE might be a viable and advantageous alternative to standard TEE or ICE.

12.
Neth Heart J ; 25(10): 536-544, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28741245

RESUMO

Heart failure has a high prevalence in the general population. Morbidity and mortality of heart failure patients remain high, despite improvements in drug therapy, implantable cardioverter-defibrillators and cardiac resynchronisation therapy. New transcatheter implantable devices have been developed to improve the treatment of heart failure. There has been a rapid development of minimally invasive or transcatheter devices used in the treatment of heart failure associated with aortic and mitral valve disease and these devices are being incorporated into routine clinical practice at a fast rate. Several other new transcatheter structural heart interventions for chronic heart failure aimed at a variety of pathophysiologic approaches are currently being developed. In this review, we focus on devices used in the treatment of chronic heart failure by means of left ventricular remodelling, left atrial pressure reduction, tricuspid regurgitation reduction and neuromodulation. The clinical evaluations of these devices are early-stage evaluations of initial feasibility and safety studies and additional clinical evidence needs to be gathered in appropriately designed clinical trials.

13.
Int J Cardiol ; 225: 218-225, 2016 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-27732925

RESUMO

AIMS: Pulmonary hypertension (PH) is associated with mortality after transcatheter aortic valve implantation (TAVI). However, diagnosis based on tricuspid regurgitant velocity (TRV) is often inaccurate and unreliable. The updated PH guidelines introduced a PH probability grading implementing additional PH signs on transthoracic echocardiography (TTE), from which we aimed to analyse its effects on clinical outcomes in patients undergoing TAVI. METHODS AND RESULTS: We included 591 consecutive patients (mean age 80.2±8.4years, 58.0% female, mean STS risk score 6.2±3.8%) undergoing TAVI. Patients were divided into "low" (n=270; TRV ≤2.8m/s without additional PH signs), "intermediate" (n=131; TRV ≤2.8m/s with additional PH signs, or TRV 2.9-3.4m/s without additional PH signs), and "high" PH probability (n=190; TRV 2.9-3.4m/s with additional PH signs, or TRV >3.4m/s). The overall 30-day and 2-year mortality rates were 10.2% and 33.8%, respectively. "High" PH probability was an independent predictor of mortality at 30days (HR 3.68, 95% CI 2.03 to 6.67, p<0.01) and 2years (HR 2.19, 95% CI 1.57 to 3.04, p<0.01), compared to "low" PH probability. The "intermediate" group did not show an increased risk. The presence of additional PH signs resulted in a significantly higher mortality at 30days (19.6% vs. 5.1%, p<0.01) and two years (54.2% vs. 22.5%, p<0.01). CONCLUSIONS: The updated echocardiographic PH probability model incorporating additional PH signs independently predicts early and late mortality after TAVI. Additional PH signs are of great value in assessing one's risks since its presence is strongly associated with early and late mortality.


Assuntos
Ecocardiografia/tendências , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/tendências , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/cirurgia , Masculino , Mortalidade/tendências , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
16.
Neth Heart J ; 24(7-8): 475-80, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27189214

RESUMO

BACKGROUND: Surgical risk scores are used to identify high-risk patients for surgical mitral valve repair. There is no scoring system to estimate the mortality risk for patients undergoing percutaneous treatment. The aim of this analysis is to evaluate the predictive value of the EuroSCOREs and the Society of Thoracic Surgeons Predicted Risk of Mortality Score (STS) for periprocedural mortality in percutaneous edge-to-edge mitral valve repair. METHODS: From 2009 to 2013, 136 high-risk patients were included who underwent 143 procedures. Observed periprocedural mortality was compared with predicted mortality using the logistic EuroSCORE, EuroSCORE II and STS. The predictive value was analysed by receiver operating characteristic curves for each score. RESULTS: Observed periprocedural mortality was 3.5 %. The predicted surgical mortality risk was: 23.1 ± 15.7 % for the logistic EuroSCORE, 9.6 ± 7.7 % for the EuroSCORE II and 13.2 ± 8.2 % for the STS. The predictive value estimated by the area under the curve was: 0.55, 0.54 and 0.65 for the logistic EuroSCORE, EuroSCORE II and STS respectively. Severe pulmonary hypertension and acute procedural success were significant predictive parameters in univariate analysis. CONCLUSION: Contemporary surgical scores do not adequately predict periprocedural mortality for high-risk patients undergoing edge-to-edge mitral valve repair, but they can be used to help decision-making in the selection process for this procedure.

17.
Neth Heart J ; 24(6): 433-434, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27167732
18.
Neth Heart J ; 23(1): 35-41, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25326104

RESUMO

AIMS: Since the introduction of transcatheter aortic valve implantation (TAVI), newer generation and novel devices such as the retrievable JenaValve™ have been developed. We evaluated the procedural and 6-month results of our first experience with implantation of the JenaValve™. METHODS AND RESULTS: From June 2012 to December 2013, 24 consecutive patients (mean age 80 ± 7 years, 42 % male) underwent an elective transapical TAVI with the JenaValve™. Device success was 88 %. The mortality rate was 4 % at 30 days and 31 % at 6 months. TAVI reduced the mean transvalvular gradient (44.2 ± 11.1 mmHg vs. 12.3 ± 4.3 mmHg, p < 0.001) and increased the mean aortic valve area (0.8 3 ± 0.23 to 1.70 ± 0.44 cm(2)). A mild paravalvular leakage (PVL) occurred in 4 patients (18 %) and a moderate PVL in 1 patient (4 %). Mean New York Heart Association Functional Class improved from 2.9 ± 0.5 to 2.0 ± 0.8 at 30 days. CONCLUSION: TAVI using the JenaValve™ prosthesis seems adequate and safe in this first experience cohort.

19.
Herz ; 38(5): 484-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23797375

RESUMO

Transcatheter edge-to-edge mitral valve repair is an approach for treating mitral regurgitation, which is an alternative for surgery in patients with a high surgical risk. Although the safety and efficacy of the technique have been demonstrated, it is still associated with potentially life-threatening complications. The aim of this paper is to discuss the nature, management, and prevention of the most important procedural complications associated with this procedure.


Assuntos
Seio Coronário/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Medicina Baseada em Evidências , Humanos , Resultado do Tratamento
20.
Neth Heart J ; 20(4): 161-6, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22231152

RESUMO

BACKGROUND: Percutaneous left atrial appendage (LAA) closure can be an alternative to coumadin treatment in patients with atrial fibrillation (AF) at high risk for thromboembolic events and/or bleeding complications. We report the initial experience with this new technique. METHODS: Patients were eligible if they had AF with a high stroke risk (CHADS(2) score >1), and/or contraindication for coumadin therapy. The procedure was performed under general anaesthesia, using biplane fluoroscopy and (3D) transoesophageal echocardiography (TEE) guidance. Patients were discharged on coumadin until a TEE was repeated at 45 days after closure to evaluate LAA occlusion. If LAA occlusion was achieved, oral anticoagulation was discontinued and aspirin started. RESULTS: Percutaneous LAA closure was performed in 10 patients (50% male, age 61.6 ± 9.6 years). The median CHADS(2) score was 3 (range 2-4), median CHA(2)DS(2)-VASc score 3.5 (range 2-6) and HAS-BLED score 1.5 (range 1-4). Nine patients had a history of stroke and 2 patients had a history of major bleeding while on coumadin. Concomitant pulmonary vein isolation was performed in 9 patients. The device was successfully placed in all patients within a median of 56 min (38-137 min). Asymptomatic catheter thrombus occurred in one patient. At 45-day follow-up, no thromboembolic events occurred, TEE showed minimal residual flow in the LAA in three patients. In one patient the LAA device was dislocated, requiring successful percutaneous retrieval. CONCLUSION: Device closure of the LAA may provide an alternative strategy to chronic coumadin therapy in patients with AF and high risk of stroke and/or bleeding complications using coumadin.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...