Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Tissue Viability ; 28(4): 179-185, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31353285

RESUMO

BACKGROUND: Deep Tissue Pressure Injury (DTI) occurs in the tissues underlying the skin that may not have visible signs of skin breakdown and may be detected by ultrasound. The optimal position for ischial region ultrasound image acquisition to facilitate assessment of the tissue proximal to the ischias not been determined. OBJECTIVE: To evaluate the mean difference in geometric and grey scale measures of tissues overlying the ischial tuberosity (IT) acquired from ultrasound images in supine and lateral recumbent simulated sitting positions from adults with spinal cord impairment (SCI). METHODS: Nine individuals (3 acute and 6 chronic) with SCI or disease with neurological level of injury C4-T12 and AIS A-D and who used a wheelchair for mobility were recruited and underwent ultrasound acquisition in the supine and lateral recumbent positions. One participant was imaged twice on a separate day. Three images from the left (n = 8) and right (n = 2) IT were scanned using a 6 - 18 MHz linear ultrasound probe (Acuson S2000) with participants' hips and knees flexed to 90° in both the supine and lateral recumbent positions using a single rater protocol. MATLAB Image Processing Toolbox with a customized script was used to obtain mean and maximal thickness, echogenicity and contrast of skin, subcutaneous tissue and muscle. Wilcoxon Signed Rank Test and Bland Altman analysis was used to determine if there were differences between the two image acquisition positions and to construct limits of agreement. RESULTS: Thickness and contrast measures were similar in the supine and lateral recumbent positions (p > 0.05). Muscle echogenicity was lower in the supine position (p = 0.04). CONCLUSION: There is agreement in geometric and grey scale measures of tissues over the IT between the supine and lateral recumbent positions with the exception of muscle echogenicity, which was lower in the supine position. Since DTI is thought to originate in the muscle and echogenicity plays in a role in abnormal tissue imaging diagnosis, further studies are recommended to determine the impact of body position on muscle echogenicity prior to being used in prospective studies.


Assuntos
Ísquio/irrigação sanguínea , Posicionamento do Paciente/normas , Pele/irrigação sanguínea , Ultrassonografia/métodos , Idoso , Austrália , Canadá , Estudos de Coortes , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente/estatística & dados numéricos , Pressão/efeitos adversos , Estudos Prospectivos , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/fisiopatologia
2.
Wound Repair Regen ; 27(5): 509-518, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31020747

RESUMO

Clinical practice guidelines recommend using repeated wound surface area measurements to determine if a chronic ulcer is healing. This results in delays in determining the healing status. This study aimed to evaluate whether any of a panel of biomarkers can determine the healing status of chronic venous leg ulcers. Forty-two patients with chronic venous leg ulcers had their wound measured and wound fluid collected at weekly time points for 13 weeks. Wound fluid was analyzed using multiplex enzyme-linked immunosorbent assay to determine the concentration of biomarkers in the wound fluid at each weekly time point. Healing status was determined by examining the change in wound size at the previous and subsequent weeks. Predictive accuracy with 95% confidence intervals (CI) is reported. Of 42 patients, 105 evaluable weekly time points were obtained, with 32 classified as healing, 27 as nonhealing, and 46 as indeterminate. Thirteen biomarkers significantly differed between healing and nonhealing wounds (p < 0.1) and were included in a multivariate logistic regression model. Granulocyte macrophage-colony stimulating factor (p < 0.001) and matrix metalloprotease-13 (p = 0.004) were the best predictors of wound healing. Receiver operating characteristic curves indicated 92% accuracy (95% CI: 85%,100%) for granulocyte macrophage-colony stimulating factor, and 78% accuracy (95% CI: 65%,90%) for matrix metalloprotease-13 in discriminating between healing and nonhealing wounds. This study found that two biomarkers from wound fluid can predict healing status in chronic venous leg ulcers. These findings may lead to the ability to determine the future trajectory of a wound and the ability to modify treatment accordingly.


Assuntos
Exsudatos e Transudatos/microbiologia , Úlcera Varicosa/patologia , Cicatrização/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Infecciosos Locais , Biomarcadores/análise , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curativos Oclusivos , Guias de Prática Clínica como Assunto , Estudos Prospectivos , Reprodutibilidade dos Testes , Úlcera Varicosa/microbiologia
3.
Top Spinal Cord Inj Rehabil ; 24(4): 371-378, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30459500

RESUMO

Background: Ultrasonography may have potential as an effective diagnostic tool for deep tissue injury (DTI) in tissues overlying bony prominences that are vulnerable when under sustained loading in sitting. Methods: Three cases of DTI in the fat and muscle layers overlying the ischial tuberosity of the pelvis in 3 persons with spinal cord injury (SCI) with different medical histories and abnormal tissue signs are described. Conclusion: There is a need for prospective studies using a reliable standardized ultrasonography protocol to diagnose DTI and to follow its natural history to determine its association with the development of pressure injuries.


Assuntos
Nádegas/diagnóstico por imagem , Úlcera por Pressão/diagnóstico por imagem , Lesões dos Tecidos Moles/diagnóstico por imagem , Traumatismos da Medula Espinal/diagnóstico por imagem , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Úlcera por Pressão/etiologia , Lesões dos Tecidos Moles/etiologia , Traumatismos da Medula Espinal/complicações , Ultrassonografia
4.
Spinal Cord ; 56(9): 823-836, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29802393

RESUMO

STUDY DESIGN: Systematic review. OBJECTIVES: To review the content and effectiveness of skin care self-management interventions for people with SCI. SETTING: International. METHODS: We searched electronic bibliographic databases, trial registers, and relevant reference lists. Eligibility criteria for the reviews of intervention content and effectiveness were identical with the exception of study design. The review of intervention content included non-randomized and randomized controlled trials (RCTs). The review of effectiveness included RCTs. A Behavior Change Technique (BCT) taxonomy of 93 BCTs was used to code intervention content. Intervention effects on outcomes of interest are summarized descriptively. Effect sizes were calculated, and the Cochrane risk of bias tool applied. RESULTS: In all, 15 studies testing 17 interventions were included in the review of intervention content. Interventions in these studies included 28 BCTs. The most common were "instructions on how to perform behavior" (16 interventions), "credible source" (12 interventions), and "social support (unspecified)" (9 interventions). Ten RCTs were included in the review of intervention effectiveness and they measured knowledge, self-efficacy, and skills relating to skin care/pressure ulcer (PU) prevention, skin care behaviors, skin status (PU prevalence, severity, and time to PU), and health-care utilization for skin problems. Evidence to support intervention effects on these outcomes was limited, particularly for clinical outcomes. Risk of bias assessments was often inconclusive due to poor reporting. CONCLUSIONS: There is potential to design SCI skin care interventions that include currently untested BCTs. Further research and better consistency in outcome measurements and reporting are required to synthesize evidence on effectiveness.


Assuntos
Autogestão/métodos , Higiene da Pele/métodos , Traumatismos da Medula Espinal , Humanos , Úlcera por Pressão/etiologia , Úlcera por Pressão/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação
5.
Spinal Cord ; 56(9): 837-846, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29795415

RESUMO

STUDY DESIGN: Systematic review. OBJECTIVES: To examine use of theory and quality of reporting in skin care self-management interventions for people with SCI. SETTING: International. METHODS: The Theory Coding Scheme (TCS) and the Template for Intervention Description and Replication (TIDieR) checklist were applied by two independent researchers to 17 interventions identified in a systematic review of self-management interventions for skin care in people with SCI. RESULTS: Six (35%) of the 17 interventions reviewed were reported to have a theoretical basis. Theories used included three of the most commonly featured in health behavior research (the Health Belief Model, Social Cognitive Theory, and the Transtheoretical Model). In these six interventions, theory was used to design content but not to select participants or tailor strategies. None of the interventions were used to test theories in the SCI population, or to propose theoretical refinements. Reporting quality was found to vary by TIDieR item, with 6-100% of interventions including recommended information. Information on two intervention fidelity items was missing in 53 and 82% of descriptions. CONCLUSIONS: Use of theory and reporting quality in SCI self-management research remains suboptimal, potentially slowing down advancements in this area of research. Rehabilitation researchers should direct their efforts toward improving these practices to help build a science of SCI self-management that is cumulative and reproducible by clinicians, scientists, and policy makers. SPONSORSHIP: This work was funded through a postdoctoral fellowship awarded to the first author by the Rick Hansen Institute.


Assuntos
Autogestão/métodos , Higiene da Pele/métodos , Traumatismos da Medula Espinal , Humanos , Modelos Teóricos , Úlcera por Pressão/etiologia , Úlcera por Pressão/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Projetos de Pesquisa , Traumatismos da Medula Espinal/complicações , Traumatismos da Medula Espinal/reabilitação
6.
J Tissue Viability ; 27(1): 32-41, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28864351

RESUMO

BACKGROUND: High strain in soft tissues that overly bony prominences are considered a risk factor for pressure ulcers (PUs) following spinal cord impairment (SCI) and have been computed using Finite Element methods (FEM). The aim of this study was to translate a MRI protocol into ultrasound (US) and determine between-operator reliability of expert sonographers measuring diameter of the inferior curvature of the ischial tuberosity (IT) and the thickness of the overlying soft tissue layers on able-bodied (AB) and SCI using real-time ultrasound. MATERIAL AND METHODS: Part 1: Fourteen AB participants with a mean age of 36.7 ± 12.09 years with 7 males and 7 females had their 3 soft tissue layers in loaded and unloaded sitting measured independently by 2 sonographers: tendon/muscle, skin/fat and total soft tissue and the diameter of the IT in its short and long axis. Part 2: Nineteen participants with SCI were screened, three were excluded due to abnormal skin signs, and eight participants (42%) were excluded for abnormal US signs with normal skin. Eight SCI participants with a mean age of 31.6 ± 13.6 years and all male with 4 paraplegics and 4 tetraplegics were measured by the same sonographers for skin, fat, tendon, muscle and total. Skin/fat and tendon/muscle were computed. RESULTS: AB between-operator reliability was good (ICC = 0.81-0.90) for 3 soft tissues layers in unloaded and loaded sitting and poor for both IT short and long axis (ICC = -0.028 and -0.01). SCI between-operator reliability was good in unloaded and loaded for total, muscle, fat, skin/fat, tendon/muscle (ICC = 0.75-0.97) and poor for tendon (ICC = 0.26 unloaded and ICC = -0.71 loaded) and skin (ICC = 0.37 unloaded and ICC = 0.10). CONCLUSION: A MRI protocol was successfully adapted for a reliable 3 soft tissue layer model and could be used in a 2-D FEM model designed to estimate soft tissue strain as a novel risk factor for the development of a PU.


Assuntos
Imageamento por Ressonância Magnética/métodos , Traumatismos da Medula Espinal/complicações , Ultrassonografia/métodos , Adulto , Análise de Variância , Estudos Transversais , Feminino , Análise de Elementos Finitos , Humanos , Ísquio/fisiologia , Ísquio/fisiopatologia , Imageamento por Ressonância Magnética/normas , Imageamento por Ressonância Magnética/tendências , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Úlcera por Pressão/fisiopatologia , Úlcera por Pressão/prevenção & controle , Reprodutibilidade dos Testes , Ultrassonografia/normas , Ultrassonografia/tendências
7.
Wound Repair Regen ; 25(5): 901-905, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28922511

RESUMO

Area measurements of a chronic wound are the gold standard outcome measure to determine if a wound is on a healing or nonhealing trajectory. The use of digital planimetry can provide increased accuracy in measuring wound area however it is important to know the reliability and measurement error of these devices when used by multiple assessors. The aim of this study is to determine the within rater, between rater, and standard error of measurement of a digital planimetry device. Wound area in 42 patients was measured weekly for 12 weeks by two different raters, with each rater measuring the wound 10 times per visit. Intraclass correlation coefficients (ICC 1,k) and standard error of measurement were calculated for both within and between raters using 10 and the first three repeated measures to determine if using less measurements was as reliable. The true change in wound area was calculated by dividing stander error of measurements by mean wound areas. Within rater reliability for raters 1 and 2 were 0.995 and 0.992 for 10 measurements, and 0.996 and 0.992 for 3 measurements per time point. Between rater reliability was 0.979 for 10 measurements and 0.996 for 3 measurements per time point. The within rater standard error of measurement for raters 1 and 2 was 0.98 cm2 and 1.28 cm2 for 10 measurements and 0.895 cm2 and 1.29 cm2 for 3 measurements at each time point. The standard error of measurement for between raters was 2.07 cm2 for 10 measurements and 2.25 cm2 for 3 measurements per time point. The true change in wound size varied from 6.4% for within one rater to 15.7% for across different raters. This study found that both within and between rater reliability of the digital planimetry device was very high for three measurements per time point.


Assuntos
Imageamento Tridimensional/métodos , Fotopletismografia/métodos , Ultrassonografia Doppler Dupla/métodos , Úlcera Varicosa/diagnóstico por imagem , Cicatrização , Idoso , Doença Crônica , Feminino , Seguimentos , Humanos , Masculino , Fotografação , Reprodutibilidade dos Testes
9.
Rehab Manag ; 16(9): 26-8, 30-1, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14621435
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...