Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Atmos Meas Tech ; 13(5)2020 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-32670429

RESUMO

NASA's Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ, conducted in 2011-2014) campaign in the United States and the joint NASA and National Institute of Environmental Research (NIER) Korea-United States Air Quality Study (KORUS-AQ, conducted in 2016) in South Korea were two field study programs that provided comprehensive, integrated datasets of airborne and surface observations of atmospheric constituents, including nitrogen dioxide (NO2), with the goal of improving the interpretation of spaceborne remote sensing data. Various types of NO2 measurements were made, including in situ concentrations and column amounts of NO2 using ground- and aircraft-based instruments, while NO2 column amounts were being derived from the Ozone Monitoring Instrument (OMI) on the Aura satellite. This study takes advantage of these unique datasets by first evaluating in situ data taken from two different instruments on the same aircraft platform, comparing coincidently sampled profile-integrated columns from aircraft spirals with remotely sensed column observations from ground-based Pandora spectrometers, intercomparing column observations from the ground (Pandora), aircraft (in situ vertical spirals), and space (OMI), and evaluating NO2 simulations from coarse Global Modeling Initiative (GMI) and high-resolution regional models. We then use these data to interpret observed discrepancies due to differences in sampling and deficiencies in the data reduction process. Finally, we assess satellite retrieval sensitivity to observed and modeled a priori NO2 profiles. Contemporaneous measurements from two aircraft instruments that likely sample similar air masses generally agree very well but are also found to differ in integrated columns by up to 31.9 %. These show even larger differences with Pandora, reaching up to 53.9 %, potentially due to a combination of strong gradients in NO2 fields that could be missed by aircraft spirals and errors in the Pandora retrievals. OMI NO2 values are about a factor of 2 lower in these highly polluted environments due in part to inaccurate retrieval assumptions (e.g., a priori profiles) but mostly to OMI's large footprint (> 312 km2).

2.
Remote Sens (Basel) ; 11(7): 796, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-31157118

RESUMO

The Radiometer Assessment using Vertically Aligned Nanotubes (RAVAN) 3U CubeSat mission is a pathfinder to demonstrate technologies for the measurement of Earth's radiation budget, the quantification of which is critical for predicting the future course of climate change. A specific motivation is the need for lower-cost technology alternatives that could be used for multi-point constellation measurements of Earth outgoing radiation. RAVAN launched 11 November 2016, into a nearly 600-km, Sun-synchronous orbit, and collected data for over 20 months. RAVAN successfully demonstrates two key technologies. The first is the use of vertically aligned carbon nanotubes (VACNTs) as absorbers in broadband radiometers for measuring Earth's outgoing radiation and the total solar irradiance. VACNT forests are arguably the blackest material known and have an extremely flat spectral response over a wide wavelength range, from the ultraviolet to the far infrared. As radiometer absorbers, they have greater sensitivity for a given time constant and are more compact than traditional cavity absorbers. The second technology demonstrated is a pair of gallium phase-change black body cells that are used as a stable reference to monitor the degradation of RAVAN's radiometer sensors on orbit. Four radiometers (two VACNT, two cavity), the pair of gallium black bodies, and associated electronics are accommodated in the payload of an agile 3U CubeSat bus that allows for routine solar and deep-space attitude maneuvers, which are essential for calibrating the Earth irradiance measurements. The radiometers show excellent long-term stability over the course of the mission and a high correlation between the VACNT and cavity radiometer technologies. Short-term variability-at greater than the tenths-of-a-Watt/m2 needed for climate accuracy-is a challenge that remains, consistent with insufficient thermal knowledge and control on a 3U CubeSat. There are also VACNT-cavity biases of 3% and 6% in the Total and SW channels, respectively, which would have to be overcome in a future mission. Although one of the black bodies failed after four months, the other provided a repeatable standard for the duration of the project. We present representative measurements from the mission and demonstrate how the radiometer time series can be used to reconstruct outgoing radiation spatial information. Improvements to the technology and approach that would lead to better performance and greater accuracy in future missions are discussed.

3.
Faraday Discuss ; 130: 181-93; discussion 241-64, 519-24, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16161784

RESUMO

Airborne observations of ozone, temperature and the spectral actinic photon flux for ozone in the Arctic lower stratosphere April-September 1997 and January-March 2000 allow a connection to be made between the rate of production of translationally hot atoms and molecules via ozone photodissociation and the intermittency of temperature. Seen in the context of non-equilibrium statistical mechanics literature results from molecular dynamics simulations, the observed correlation between the molecular scale production of translationally hot atoms and molecules and the macroscopic fluid mechanical intermittency of temperature may imply a departure from Maxwell-Boltzmann distributions of molecular velocities, with consequences for chemistry, radiative line shapes and turbulence in the atmosphere, arising from overpopulated high velocity tails of the probability distribution functions (PDFs).


Assuntos
Pressão Atmosférica , Ozônio/análise , Fotoquímica , Animais , Regiões Árticas , Humanos , Matemática , Ozônio/química , Probabilidade , Temperatura , Fatores de Tempo
4.
Am J Public Health ; 93(6): 999-1006, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12773368

RESUMO

OBJECTIVE: We compared outcomes, safety, and resource utilization in a collaborative management birth center model of perinatal care versus traditional physician-based care. METHODS: We studied 2957 low-risk, low-income women: 1808 receiving collaborative care and 1149 receiving traditional care. RESULTS: Major antepartum (adjusted risk difference [RD] = -0.5%; 95% confidence interval [CI] = -2.5, 1.5), intrapartum (adjusted RD = 0.8%; 95% CI = -2.4, 4.0), and neonatal (adjusted RD = -1.8%; 95% CI = -3.8, 0.1) complications were similar, as were neonatal intensive care unit admissions (adjusted RD = -1.3%; 95% CI = -3.8, 1.1). Collaborative care had a greater number of normal spontaneous vaginal deliveries (adjusted RD = 14.9%; 95% CI = 11.5, 18.3) and less use of epidural anesthesia (adjusted RD = -35.7%; 95% CI = -39.5, -31.8). CONCLUSIONS: For low-risk women, both scenarios result in safe outcomes for mothers and babies. However, fewer operative deliveries and medical resources were used in collaborative care.


Assuntos
Centros de Assistência à Gravidez e ao Parto/organização & administração , Administração de Caso , Enfermeiros Obstétricos/organização & administração , Obstetrícia/organização & administração , Avaliação de Processos e Resultados em Cuidados de Saúde , Cuidado Pré-Natal/organização & administração , Adulto , Centros de Assistência à Gravidez e ao Parto/normas , California/epidemiologia , Estudos de Coortes , Comportamento Cooperativo , Prestação Integrada de Cuidados de Saúde/organização & administração , Parto Obstétrico/métodos , Feminino , Recursos em Saúde/estatística & dados numéricos , Pesquisa sobre Serviços de Saúde , Hospitalização , Humanos , Recém-Nascido , Modelos Organizacionais , Enfermeiros Obstétricos/normas , Obstetrícia/normas , Relações Médico-Enfermeiro , Gravidez , Complicações na Gravidez/epidemiologia , Cuidado Pré-Natal/normas , Estudos Prospectivos
5.
J Obstet Gynecol Neonatal Nurs ; 32(2): 147-57; discussion 158-60, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12685666

RESUMO

OBJECTIVE: This study compared the effects of early admission in labor and perinatal care provider on delivery method. Higher spontaneous vaginal delivery rates for certified nurse midwives as compared with physicians have been reported in observational studies and randomized clinical trials. Certified nurse midwives, with their more expectant approach to labor management, would be expected to admit women later in labor than obstetricians. METHODS: Prospective cohort study of 2,196 low-risk pregnancies, with singleton, vertex infants admitted in spontaneous labor. Independent and joint effects of perinatal care provider and cervical dilation at admission on delivery method were evaluated. Confounding was addressed using restriction and multiple regression. RESULTS: Fewer (23.4%) women in collaborative care were admitted in early labor (< 4 cm cervical dilation) than women managed by obstetricians (95% CI = -27.6 to -19.2). Obstetrician care had 9% to 30% fewer spontaneous vaginal deliveries. Women admitted early in labor also had 6% to 34% fewer spontaneous vaginal deliveries. Evaluation of joint effects suggested that interaction between obstetrician provider and earlier admission increased the risk of operative delivery. CONCLUSION: Later admission in labor (at 4 cm or greater cervical dilation) and management of perinatal care by certified nurse midwives in collaboration with obstetricians increased the rate of spontaneous vaginal delivery in low-risk women.


Assuntos
Parto Obstétrico/enfermagem , Início do Trabalho de Parto , Parto Normal/enfermagem , Enfermeiros Obstétricos/normas , Adulto , Cesárea/enfermagem , Cesárea/estatística & dados numéricos , Estudos de Coortes , Parto Obstétrico/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Trabalho de Parto , Parto Normal/estatística & dados numéricos , Papel do Profissional de Enfermagem , Assistência Perinatal/métodos , Padrões de Prática Médica/normas , Gravidez , Estudos Prospectivos , Risco , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...