Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1730: 465022, 2024 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-38861824

RESUMO

The forensic analysis of amide-based synthetic cannabinoids (SCs) in seized materials is routinely performed using gas chromatography-mass spectrometry (GC-MS); however, a major challenge associated with GC-MS is the thermolytic degradation of substances with sensitive functional groups. Herein, we report the comprehensive thermal degradation and ester transformation of amide-based SCs, such as AB-FUBINACA, AB-CHMINACA, and MAB-CHMINACA, during GC-MS analysis and their treatment with analyte protectants (APs). These SCs were found to undergo thermolytic degradation during GC-MS in the presence of non-alcohol solvents. Using methanol as an injection solvent resulted in the conversion of the amide group to an ester group, producing other SCs such as AMB-FUBINACA, MA-CHMINACA, and MDMB-CHMINACA. Degradant and ester product formation has been interpreted as the adsorption of target SCs on glass wool via hydrogen bonding interactions between the active silanol and amide groups of the SCs, followed by an addition and/or elimination process. The factors found to influence the thermal degradation and/or esterification of the amide functional group include residence time, activity of glass wool, and injection volume. This report presents the fragmentation patterns of all compounds that were produced by degradation and esterification. Using 0.5 % sorbitol (AP) in MeOH as an injection solvent resulted in complete protection and improvement of the chromatographic shape of the compounds. This method has been successfully confirmed in terms of sensitivity, linearity, accuracy, and precision for standard solutions and tablet extraction using 0.5 % sorbitol in MeOH. Using AP increased the sensitivity by ten times or more compared to the use of only MeOH. The limit of detection for all analytes was determined as 25 ng/mL, and the calibration curves were linear over the concentration range of 50-2000 ng/mL. The values of accuracy error were below 11 %, and precision was less than 13 %. The effects of phytochemicals of herbal products, tablet ingredients, and biological matrices on the degradation and/or esterification and APs performance have also been evaluated in this work.


Assuntos
Canabinoides , Cromatografia Gasosa-Espectrometria de Massas , Canabinoides/química , Canabinoides/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Esterificação , Amidas/química , Amidas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA