Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
AJNR Am J Neuroradiol ; 38(11): 2059-2066, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28882862

RESUMO

BACKGROUND AND PURPOSE: Accurate follow-up of metastatic brain tumors has important implications for patient prognosis and management. The aim of this study was to develop and evaluate the accuracy of a semiautomated algorithm in detecting growing or shrinking metastatic brain tumors on longitudinal brain MRIs. MATERIALS AND METHODS: We used 50 pairs of successive MR imaging datasets, 30 on 1.5T and 20 on 3T, containing contrast-enhanced 3D T1-weighted sequences. These yielded 150 growing or shrinking metastatic brain tumors. To detect them, we completed 2 major steps: 1) spatial normalization and calculation of the Jacobian operator field to quantify changes between scans, and 2) metastatic brain tumor candidate segmentation and detection of volume-changing metastatic brain tumors with the Jacobian operator field. Receiver operating characteristic analysis was used to assess the detection accuracy of the algorithm, and it was verified with jackknife resampling. The reference standard was based on detections by a neuroradiologist. RESULTS: The areas under the receiver operating characteristic curves were 0.925 for 1.5T and 0.965 for 3T. Furthermore, at its optimal performance, the algorithm achieved a sensitivity of 85.1% and 92.1% and specificity of 86.7% and 91.3% for 1.5T and 3T, respectively. Vessels were responsible for most false-positives. Newly developed or resolved metastatic brain tumors were a major source of false-negatives. CONCLUSIONS: The proposed algorithm could detect volume-changing metastatic brain tumors on longitudinal brain MRIs with statistically high accuracy, demonstrating its potential as a computer-aided change-detection tool for complementing the performance of radiologists, decreasing inter- and intraobserver variability, and improving efficacy.


Assuntos
Algoritmos , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/secundário , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
2.
AJNR Am J Neuroradiol ; 38(1): 195-199, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27884880

RESUMO

BACKGROUND AND PURPOSE: Spinal epidural AVFs are rare spinal vascular malformations. When there is associated intradural venous reflux, they may mimic the more common spinal dural AVFs. Correct diagnosis and localization before conventional angiography is beneficial to facilitate treatment. We hypothesize that first-pass contrast-enhanced MRA can diagnose and localize spinal epidural AVFs with intradural venous reflux and distinguish them from other spinal AVFs. MATERIALS AND METHODS: Forty-two consecutive patients with a clinical and/or radiologic suspicion of spinal AVF underwent MR imaging, first-pass contrast-enhanced MRA, and DSA at a single institute (2000-2015). MR imaging/MRA and DSA studies were reviewed by 2 independent blinded observers. DSA was used as the reference standard. RESULTS: On MRA, all 7 spinal epidural AVFs with intradural venous reflux were correctly diagnosed and localized with no interobserver disagreement. The key diagnostic feature was arterialized filling of an epidural venous pouch with a refluxing radicular vein arising from the arterialized epidural venous system. CONCLUSIONS: First-pass contrast-enhanced MRA is a reliable and useful technique for the initial diagnosis and localization of spinal epidural AVFs with intradural venous reflux and can distinguish these lesions from other spinal AVFs.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Espaço Epidural/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Medula Espinal/diagnóstico por imagem , Idoso , Angiografia Digital/métodos , Malformações Vasculares do Sistema Nervoso Central/patologia , Espaço Epidural/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medula Espinal/patologia
3.
AJNR Am J Neuroradiol ; 38(1): 200-205, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27811131

RESUMO

BACKGROUND AND PURPOSE: Catheter angiography is typically used for follow-up of treated spinal AVFs. The purpose of this study was to determine the diagnostic performance and utility of first-pass contrast-enhanced MRA in the posttreatment evaluation of spinal AVFs compared with DSA. MATERIALS AND METHODS: A retrospective review was performed of all patients at our tertiary referral hospital (from January 2000 to April 2015) who underwent spine MR imaging, first-pass contrast-enhanced MRA, and DSA after surgical and/or endovascular treatment of a spinal AVF. Presence of recurrent or residual fistula on MRA, including vertebral level of the recurrent/residual fistula, was evaluated by 2 experienced neuroradiologists blinded to DSA findings. Posttreatment conventional MR imaging findings were also evaluated, including presence of intramedullary T2 hyperintensity, perimedullary serpentine flow voids, and cord enhancement. The performance of MRA and MR imaging findings for diagnosis of recurrent/residual fistula was determined by using DSA as the criterion standard. RESULTS: In total, 28 posttreatment paired MR imaging/MRA and DSA studies were evaluated in 22 patients with prior spinal AVF and 1 patient with intracranial AVF with prior cervical perimedullary venous drainage. Six image sets of 5 patients demonstrated recurrent/residual disease at DSA. MRA correctly identified all cases with recurrent/residual disease with 1 false-positive (sensitivity, 100%; specificity 95%; P < .001), with correct localization in all cases without interobserver disagreement. Conventional MR imaging parameters were not significantly associated with recurrent/residual spinal AVF. CONCLUSIONS: First-pass MRA demonstrates high sensitivity and specificity for identifying recurrent/residual spinal AVFs and may potentially substitute for DSA in the posttreatment follow-up of patients with spinal AVFs.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Angiografia Digital/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
4.
AJNR Am J Neuroradiol ; 38(1): 206-212, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27811132

RESUMO

BACKGROUND AND PURPOSE: Different MRA techniques used to evaluate spinal dural arteriovenous fistulas offer unique advantages and limitations with regards to temporal and spatial resolution. The purpose of this study was to compare the efficacy and interobserver agreement of 2 commonly used contrast-enhanced spinal MRA techniques, multiphase time-resolved MRA and single-phase first-pass MRA, in assessment of spinal dural arteriovenous fistulas. MATERIALS AND METHODS: Retrospective review of 15 time-resolved and 31 first-pass MRA studies in patients with clinical suspicion of spinal dural arteriovenous fistula was performed by 2 independent, blinded observers. DSA was used as the reference standard to compare the diagnostic performance of the 2 techniques. RESULTS: There were 10 cases of spinal dural arteriovenous fistula in the time-resolved MRA group and 20 in the first-pass MRA group. Time-resolved MRA detected spinal dural arteriovenous fistulas with sensitivity and specificity of 100% and 80%, respectively, with 100% correct-level localization rate. First-pass MRA detected spinal dural arteriovenous fistulas with sensitivity and specificity of 100% and 82%, respectively, with 87% correct-level localization rate. Interobserver agreement for localization was excellent for both techniques; however, it was higher for time-resolved MRA. In 5 cases, the site of fistula was not included in the FOV, but a prominent intradural radicular vein was observed at the edge of the FOV. CONCLUSIONS: Multiphase time-resolved MRA and single-phase first-pass MRA were comparable in diagnosis and localization of spinal dural arteriovenous fistulas and demonstrated excellent interobserver agreement, though there were more instances of ambiguity in fistula localization on first-pass MRA.


Assuntos
Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
5.
AJNR Am J Neuroradiol ; 37(11): 2026-2032, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27313130

RESUMO

BACKGROUND AND PURPOSE: Signs suggestive of unexpected dural venous sinus thrombosis are detectable on routine MR imaging studies without MRV. We assessed performance characteristics and interrater reliability of routine MR imaging for the diagnosis of dural venous sinus thrombosis, focusing on the superior sagittal, transverse, and sigmoid sinuses. MATERIALS AND METHODS: This case series included 350 patients with MRIs performed with contrast-enhanced MRV and 79 patients with routine MRIs performed within 48 hours of a CTV from 2008 to 2014 (total, n = 429). Routine MR images were separated from the contrast-enhanced MRVs and CTVs. Three neuroradiologists, blinded to clinical data, independently reviewed the MRIs for signs of dural venous sinus thrombosis, including high signal on sagittal T1, loss of flow void on axial T2, high signal on FLAIR, high signal on DWI, increased susceptibility effects on T2*-weighted gradient recalled-echo imaging, and filling defects on axial contrast-enhanced spin-echo T1WI and/or volumetric gradient-echo T1WI. Two neuroradiologists independently reviewed contrast-enhanced MRVs and CTVs to determine the consensus gold standard. Interrater reliability was calculated by using the κ coefficient. RESULTS: Contrast-enhanced MRV and CTV confirmed that dural venous sinus thrombosis was present in 72 of 429 cases (16.8%). The combination of routine MR sequences had an overall sensitivity of 79.2%, specificity of 89.9%, and moderate interrater reliability (κ = 0.50). The 3 readers did not have similar performance characteristics. 69.4% of positive cases had clinical suspicion of dural venous sinus thrombosis indicated on imaging requisition. CONCLUSIONS: Routine MR images can suggest dural venous sinus thrombosis with high specificity in high-risk patients, even in cases without clinical suspicion.

6.
AJNR Am J Neuroradiol ; 36(12): 2285-91, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26471754

RESUMO

BACKGROUND AND PURPOSE: Good CTA collaterals independently predict good outcome in acute ischemic stroke. Our aim was to evaluate the role of collateral circulation and its added benefit over CTP-derived total ischemic volume as a predictor of baseline NIHSS score, total ischemic volume, hemorrhagic transformation, final infarct size, and a modified Rankin Scale score >2. MATERIALS AND METHODS: This was a retrospective study of 395 patients with stroke dichotomized by recanalization (recanalization positive/recanalization negative) and collateral status. Clot burden score was quantified on baseline CTA. Total ischemic volumes were derived from thresholded CTP maps. Final infarct size was assessed on follow-up CT/MRI. We performed uni-/multivariate analyses for each outcome, adjusting for rtPA status, using general linear (continuous variables) and logistic (binary variables) regression. Model comparison with collateral score and total ischemic volume was performed using the F or likelihood ratio test. RESULTS: Collateral presence independently and inversely predicted all outcomes except hemorrhagic transformation in patients who were recanalization negative and mRS >2 in patients who were recanalization positive. The greatest collateral benefit occurred in patients who were recanalization negative, contributing 16.5% and 19.2% of the variability for final infarct size and mRS >2. The collateral score model is superior to the total ischemic volume for mRS >2 prediction, but a combination of total ischemic volume and collateral score is superior for mRS >2 and final infarct prediction (24% and 28% variability, respectively). In patients who were recanalization positive, a model including collateral score and total ischemic volume was superior to that of total ischemic volume for hemorrhagic transformation and final infarct prediction but was muted compared with patients who were recanalization negative (11.3% and 16.9% variability). CONCLUSIONS: Collateral circulation is an independent predictor of all outcomes, but the magnitude of significance varies, greater in patients who were recanalization negative versus recanalization positive. Total ischemic volume assessment is complementary to collateral score in many cases.


Assuntos
Encéfalo/irrigação sanguínea , Circulação Colateral/fisiologia , Acidente Vascular Cerebral/patologia , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
7.
AJNR Am J Neuroradiol ; 36(6): 1069-75, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25721075

RESUMO

BACKGROUND AND PURPOSE: Lacunar infarcts account for approximately 25% of acute ischemic strokes. Compared with NCCT alone, the addition of CTP improves sensitivity for detection of infarcts overall. Our aim was to systematically evaluate the diagnostic benefit and interobserver reliability of an incremental CT protocol in lacunar infarction. MATERIALS AND METHODS: Institutional review board approval and patient consent were obtained. One hundred sixty-three patients presenting with a lacunar syndrome ≤4.5 hours from symptom onset were enrolled. Images were reviewed incrementally by 2 blinded readers in 3 separate sessions (NCCT only, NCCT/CTA, and NCCT/CTA/CTP). Diagnostic confidence was recorded on a 6-point scale with DWI/ADC as a reference. Logistic regression analysis calculated differences between actual and observed diagnoses, adjusted for confidence. Predictive effects of observed diagnostic accuracy and confidence score were quantified with the entropy r(2) value. Sensitivity, specificity, and confidence intervals were calculated accounting for multiple readers. Receiver operating characteristic analyses were compared among diagnostic strategies. Interobserver agreement was established with Cohen κ statistic. RESULTS: The final study cohort comprised 88 patients (50% male). DWI/ADC-confirmed lacunar infarction occurred in 59/88 (67%) with 36/59 (61%) demonstrating a concordant abnormal finding on CTP. Sensitivity for definite or probable presence of lacunar infarct increased significantly from 9.3% to 42.4% with incremental protocol use, though specificity was unchanged (range, 91.9%-95.3%). The observed diagnosis was significantly related to the actual diagnosis after adjusting for CTP confidence level (P = .04) and was 5.1 and 2.4 times more likely to confirm lacunar infarct than NCCT or CTA source images. CTP area under the curve (0.77) was significantly higher than that of CTA source images (0.68, P = .006) or NCCT (0.55, P < .001). CONCLUSIONS: CTP offers an improved diagnostic benefit over NCCT and CTA for the diagnosis of lacunar infarction.


Assuntos
Angiografia Cerebral/métodos , Imagem Multimodal/métodos , Acidente Vascular Cerebral Lacunar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
8.
AJNR Am J Neuroradiol ; 36(4): 646-52, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25572947

RESUMO

BACKGROUND AND PURPOSE: Stroke Prognostication by Using Age and NIHSS score (SPAN-100 index) facilitates stroke outcomes. We assessed imaging markers associated with the SPAN-100 index and their additional impact on outcome determination. MATERIALS AND METHODS: Of 273 consecutive patients with acute ischemic stroke (<4.5 hours), 55 were characterized as SPAN-100-positive (age +NIHSS score ≥ 100). A comprehensive imaging review evaluated differences, using the presence of the hyperattenuated vessel sign, ASPECTS, clot burden score, collateral score, CBV, CBF, and MTT. The primary outcome assessed was favorable outcome (mRS ≤ 2). Secondary outcomes included recanalization, lack of neurologic improvement, and hemorrhagic transformation. Uni- and multivariate analyses assessed factors associated with favorable outcome. Area under the curve evaluated predictors of favorable clinical outcome. RESULTS: Compared with the SPAN-100-negative group, the SPAN-100-positive group (55/273; 20%) demonstrated larger CBVs (<0.001), poorer collaterals (P < .001), and increased hemorrhagic transformation rates (56.0% versus 36%, P = .02) despite earlier time to rtPA (P = .03). Favorable outcome was less common among patients with SPAN-100-positive compared with SPAN-100-negative (10.9% versus 42.2%; P < .001). Multivariate regression revealed poorer outcome for SPAN-100-positive (OR = 0.17; 95% CI, 0.06-0.38; P = .001), clot burden score (OR = 1.14; 95% CI, 1.05-1.25; P < .001), and CBV (OR = 0.58; 95% CI, 0.46-0.72; P = .001). The addition of the clot burden score and CBV improved the predictive value of SPAN-100 alone for favorable outcome from 60% to 68% and 74%, respectively. CONCLUSIONS: SPAN-100-positivity predicts a lower likelihood of favorable outcome and increased hemorrhagic transformation. CBV and clot burden score contribute to poorer outcomes among high-risk patients and improve stroke-outcome prediction.


Assuntos
Infarto Encefálico/diagnóstico , Acidente Vascular Cerebral/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Angiografia Cerebral/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Trombose Intracraniana/diagnóstico , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Estudos Retrospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/diagnóstico por imagem , Resultado do Tratamento
9.
AJNR Am J Neuroradiol ; 34(1): 146-52, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22700751

RESUMO

BACKGROUND AND PURPOSE: Recanalization may not result in better clinical outcomes after ischemic stroke. We determined the incidence and significant predictors of CMR, defined as CT angiographic recanalization and a good clinical outcome, after IV-rtPA in acute ischemic stroke. A CMR score was devised and tested. MATERIALS AND METHODS: One hundred twenty-six consecutive patients with anterior circulation ischemic stroke receiving IV-rtPA were retrospectively reviewed. Imaging included a baseline NCCT and CTA. Recanalization was assessed on a 24-hour CTA. Clinical outcome was determined by the 90-day mRS. CMR was defined as CTA recanalization and a good clinical outcome (mRS ≤2). Logistic regression analysis determined predictors of CMR. The predictive ability of a CMR score was tested with AIC. RESULTS: CMR occurred in 29% (36/126). Patients with CMR had fewer neurologic deficits (P = .001) and higher ASPECTS (P = .041) at baseline than those without CMR. Baseline NIHSS score did not predict proximal occlusion (OR 0.959; 95% CI [0.907-1.014]; P = .141). Multivariate analysis showed admission NIHSS score (P = .001) and the site of vessel occlusion (P = .022) to be significant CMR predictors. CMR was significantly less likely in patients with proximal occlusions (ICA, P = .005; proximal M1, P = .021). A CMR score better predicted CMR than either NIHSS or vessel occlusion site alone (P < .0001). CONCLUSIONS: Milder baseline stroke deficit and distal vessel occlusion are significant predictors of CMR. A combination of these parameters better predicts CMR than either parameter alone.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/prevenção & controle , Angiografia Cerebral/estatística & dados numéricos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/prevenção & controle , Ativador de Plasminogênio Tecidual/administração & dosagem , Idoso , Isquemia Encefálica/epidemiologia , Comorbidade , Fibrinolíticos/administração & dosagem , Humanos , Ontário/epidemiologia , Avaliação de Resultados em Cuidados de Saúde/métodos , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Prevalência , Prognóstico , Proteínas Recombinantes/administração & dosagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Sensibilidade e Especificidade , Acidente Vascular Cerebral/epidemiologia , Ativador de Plasminogênio Tecidual/genética , Resultado do Tratamento
10.
AJNR Am J Neuroradiol ; 34(4): 773-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23079406

RESUMO

BACKGROUND AND PURPOSE: Contrast extravasation within spontaneous intracranial hemorrhage is a well-described predictor of hematoma growth, poor clinical outcome, and mortality. The purpose of this study was to assess the prognostic value of contrast extravasation in acute traumatic intracranial hematomas. MATERIALS AND METHODS: In our institution, CTA (including PCCT) is the primary screening technique for cervical vascular injuries. Sixty consecutive patients with at least 1 acute intracranial hematoma (ICH, subdural hematoma, and/or epidural hematoma) meeting predefined size criteria, with CTA/PCCT performed within 24 hours of admission and follow-up CT within 72 hours of admission, were retrospectively evaluated for CE by 2 observers. The predictive value of CE for a composite outcome (hematoma expansion, need for hematoma evacuation, in-hospital mortality) was evaluated on a per-patient basis. Interobserver agreement for CE and the association between baseline variables and outcome were also examined. Different patterns of extravasation were evaluated on a per-lesion basis, with outcomes including hematoma expansion and evacuation. RESULTS: CE was present in 30 (50%) patients with almost perfect interobserver agreement (κ=0.87; 95% CI, 0.74-0.99). The per-patient multivariate analysis showed independent association of midline shift (P=.020), Glasgow Coma Scale score≤8 (P=.024), and CE (P=.017), with poor outcome and demonstrated a trend toward poor outcome prediction for age 65 years or older (P=.050). In the per-lesion analysis, only extravasation identified on CTA (active and contained extravasation) was associated with hematoma expansion and evacuation. CONCLUSIONS: Contrast extravasation within intracranial hematomas predicts poor in-hospital outcome in the setting of acute traumatic intracranial injuries.


Assuntos
Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Hematoma Epidural Craniano/diagnóstico por imagem , Hematoma Subdural Agudo/diagnóstico por imagem , Hemorragia Intracraniana Traumática/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Extravasamento de Materiais Terapêuticos e Diagnósticos/mortalidade , Feminino , Escala de Coma de Glasgow , Hematoma Epidural Craniano/mortalidade , Hematoma Subdural Agudo/mortalidade , Mortalidade Hospitalar , Humanos , Hemorragia Intracraniana Traumática/mortalidade , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/estatística & dados numéricos
12.
AJNR Am J Neuroradiol ; 32(11): 2132-5, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21903915

RESUMO

BACKGROUND AND PURPOSE: CTA provides high-resolution imaging of the head and neck vasculature but also of the soft tissues and bones. This results in a large volume of information to be interpreted. This study examines interpretation errors with head and neck CTAs and assesses whether double reading reduces miss rates. MATERIALS AND METHODS: Consecutive CTAs of the neck and intracranial circulation were retrospectively identified and reviewed for vascular and nonvascular findings by a consensus of 2 neuroradiologists. The results were compared with the official report. Significant discrepancies were considered those that would have influenced follow-up or management. RESULTS: We reviewed 503 studies; 144 were originally reported by a staff neuroradiologist alone, 209 by staff and diagnostic radiology resident, and 150 by staff and neuroradiology fellow. Twenty-six significant discrepancies were discovered in 20 studies, corresponding to 4.0% of studies with at least 1 miss, and an overall miss rate per study of 5.2%. There was at least 1 miss in 6.3% of studies interpreted by a staff neuroradiologist alone, 3.3% by staff and resident, and 2.7% by staff and fellow. The miss rate differences were not statistically significant. The most common misses were small aneurysms (50% of misses). CONCLUSIONS: CTA neck and head datasets are now large, and there is a potential for missed findings. Significant discrepancies can occur with a low but not insignificant rate. Arterial pathology accounted for most discrepancies. This study emphasizes the need for careful systematic scrutiny for both vascular and nonvascular pathology regardless of indication. Double reading reduces error rates.


Assuntos
Angiografia/métodos , Artefatos , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças Arteriais Cerebrais/diagnóstico por imagem , Aumento da Imagem/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Cabeça/irrigação sanguínea , Cabeça/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
AJNR Am J Neuroradiol ; 32(10): 1879-84, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21885714

RESUMO

BACKGROUND AND PURPOSE: For patients with ICH, knowing the rate of CT contrast extravasation may provide insight into the pathophysiology of hematoma expansion. This study assessed whether the PCT-derived PS can measure different rates of CT contrast extravasation for admission CTA spot signs, PCCT, PCL, and regions without extravasation in patients with ICH. MATERIALS AND METHODS: CT was performed at admission and at 24 hours for 16 patients with ICH with/without contrast extravasation seen on CTA and PCCT. PCT-PS was measured at admission. The Wilcoxon rank sum test with a Bonferroni correction was used to compare PS values from the following regions of interest: 1) spot sign lesions only (9 foci), 2) PCL lesions only (9 foci), 3) hematoma excluding extravasation, 4) regions contralateral to extravasation, 5) hematoma in patients without extravasation, and 6) an area contralateral to that in 5. Additionally, hematoma expansion was determined at 24 hours defined by NCCT. RESULTS: PS was 6.5 ± 1.60 mL · min(-1) × (100 g)(-1), 0.95 ± 0.39 mL · min(-1) × (100 g)(-1), 0.12 ± 0.39 mL · min(-1) × (100 g)(-1), 0.26 ± 0.09 mL · min(-1) × (100 g)(-1), 0.38 ± 0.26 mL · min(-1) × (100 g)(-1), and 0.09 ± 0.32 mL · min(-1) × (100 g)(-1) for the following: 1) spot sign lesions only (9 foci), 2) PCL lesions only (9 foci), 3) hematoma excluding extravasation, 4) regions contralateral to extravasation, 5) hematoma in patients without extravasation, and 6) an area contralateral to that in 5. PS values from spot sign lesions and PCL lesions were significantly different from each other and all other regions, respectively (P < .05). Hematoma volume increased from 34.1 ± 41.0 mL to 40.2 ± 46.1 mL in extravasation-positive patients and decreased from 19.8 ± 31.8 mL to 17.4 ± 27.3 mL in extravasation-negative patients. CONCLUSIONS: The PCT-PS parameter measures a higher rate of contrast extravasation for CTA spot sign lesions compared with PCL lesions and hematoma. Early extravasation was associated with hematoma expansion.


Assuntos
Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/metabolismo , Extravasamento de Materiais Terapêuticos e Diagnósticos/diagnóstico por imagem , Extravasamento de Materiais Terapêuticos e Diagnósticos/metabolismo , Iodo/farmacocinética , Tomografia Computadorizada por Raios X/métodos , Idoso , Hemorragia Cerebral/complicações , Meios de Contraste/farmacocinética , Extravasamento de Materiais Terapêuticos e Diagnósticos/etiologia , Feminino , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade
14.
Diabet Med ; 28(2): 175-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21219425

RESUMO

AIMS: To investigate the impact of wound fluid lactate concentration on diagnosing soft-tissue infection in diabetic foot ulcers. METHODS: Lactate concentration in wound fluid obtained from diabetic foot ulcers was determined using a lactate analyser and compared with clinical examination findings. RESULTS: Overall median wound fluid lactate concentration was 21.03 mm (5.58-80.40 mm). Wound lactate levels were significantly higher in infected compared with non-infected diabetic foot ulcers (P=0.001). Non-infected diabetic foot ulcers that healed within 6 months of treatment showed a significantly lower wound fluid lactate concentration at baseline as opposed to those that did not heal (P=0.007). CONCLUSIONS: Non-healing diabetic foot ulcers are characterized by high wound fluid lactate levels. Assessment of wound fluid lactate concentration might be helpful for confirming the suspicion of soft tissue infection, particularly when clinical signs are atypical.


Assuntos
Líquidos Corporais/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Pé Diabético/metabolismo , Ácido Láctico/metabolismo , Infecções dos Tecidos Moles/diagnóstico , Infecções dos Tecidos Moles/metabolismo , Ferimentos e Lesões/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Amputação Cirúrgica , Biomarcadores/metabolismo , Líquidos Corporais/microbiologia , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/microbiologia , Pé Diabético/diagnóstico , Pé Diabético/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infecções dos Tecidos Moles/microbiologia , Cicatrização , Ferimentos e Lesões/microbiologia
15.
AJNR Am J Neuroradiol ; 32(2): 359-64, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21051518

RESUMO

BACKGROUND AND PURPOSE: CTA-SI have been previously reported to correlate with CBV. We hypothesized that CTA-SI performed by modern multisection CT scanners are CBF-, not CBV-weighted. MATERIALS AND METHODS: Sixty-four consecutive patients with anterior circulation stroke symptoms were selected from a stroke data base between June 2007 and January 2009. Two independent blinded readers calculated defect volumes of CTA-SI and PCCT, CBF, and CBV images. Spearman correlation of lesion volumes was performed. Linear regression and residual analysis demonstrated factors associated with outliers for CTA or PCCT for CBF and CBV volumes. RESULTS: We found a strong positive correlation between CTA with CBF (r = 0.89, P < .0001) and between PCCT and CBV (r = 0.79, P < .0001). CTA to CBV (r = 0.5, P < .0001) and PCCT to CBF (r = 0.52, P < .0001) correlations were weaker. Positive CTA outliers had lower ASPECTS (P = .01), larger baseline CTA (149 ± 46 cm(3) versus 83 ± 32 cm(3); P = .002, respectively), and final infarct (190 ± 100 cm(3) versus 80 ± 50 cm(3); P = .09, respectively) volumes than nonoutliers. No baseline features were significantly related to PCCT outliers. There was no difference in the vessel occlusion sites for positive or negative outliers for CTA or PCCT (P = .55 and P = 1.00, respectively). CONCLUSIONS: Our results indicate that CTA-SI are CBF- rather than CBV-weighted.


Assuntos
Volume Sanguíneo/fisiologia , Angiografia Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Infarto da Artéria Cerebral Anterior/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Bases de Dados Factuais , Humanos , Infarto da Artéria Cerebral Anterior/fisiopatologia , Modelos Lineares
16.
Eur Arch Psychiatry Clin Neurosci ; 260 Suppl 2: S81-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20945070

RESUMO

Obstetric complications play a role in the pathophysiology of schizophrenia. However, the biological consequences during neurodevelopment until adulthood are unknown. Microarrays have been used for expression profiling in four brain regions of a rat model of neonatal hypoxia as a common factor of obstetric complications. Animals were repeatedly exposed to chronic hypoxia from postnatal (PD) day 4 through day 8 and killed at the age of 150 days. Additional groups of rats were treated with clozapine from PD 120-150. Self-spotted chips containing 340 cDNAs related to the glutamate system ("glutamate chips") were used. The data show differential (up and down) regulations of numerous genes in frontal (FR), temporal (TE) and parietal cortex (PAR), and in caudate putamen (CPU), but evidently many more genes are upregulated in frontal and temporal cortex, whereas in parietal cortex the majority of genes are downregulated. Because of their primary presynaptic occurrence, five differentially expressed genes (CPX1, NPY, NRXN1, SNAP-25, and STX1A) have been selected for comparisons with clozapine-treated animals by qRT-PCR. Complexin 1 is upregulated in FR and TE cortex but unchanged in PAR by hypoxic treatment. Clozapine downregulates it in FR but upregulates it in PAR cortex. Similarly, syntaxin 1A was upregulated in FR, but downregulated in TE and unchanged in PAR cortex, whereas clozapine downregulated it in FR but upregulated it in PAR cortex. Hence, hypoxia alters gene expression regionally specific, which is in agreement with reports on differentially expressed presynaptic genes in schizophrenia. Chronic clozapine treatment may contribute to normalize synaptic connectivity.


Assuntos
Encéfalo/metabolismo , Carboxipeptidases/metabolismo , Regulação da Expressão Gênica/fisiologia , Hipóxia/patologia , Neuropeptídeo Y/metabolismo , Receptores de Superfície Celular/metabolismo , Proteína 25 Associada a Sinaptossoma/metabolismo , Sintaxina 1/metabolismo , Animais , Animais Recém-Nascidos , Antipsicóticos/farmacologia , Antipsicóticos/uso terapêutico , Encéfalo/efeitos dos fármacos , Encéfalo/patologia , Carboxipeptidases/genética , Clozapina/farmacologia , Clozapina/uso terapêutico , Modelos Animais de Doenças , Perfilação da Expressão Gênica/métodos , Regulação da Expressão Gênica/efeitos dos fármacos , Hipóxia/tratamento farmacológico , Hipóxia/fisiopatologia , Inibição Neural/efeitos dos fármacos , Inibição Neural/fisiologia , Neuropeptídeo Y/genética , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Ratos , Ratos Sprague-Dawley , Receptores de Superfície Celular/genética , Proteína 25 Associada a Sinaptossoma/genética , Sintaxina 1/genética
17.
AJNR Am J Neuroradiol ; 31(8): 1403-7, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20466799

RESUMO

BACKGROUND AND PURPOSE: Calcium can potentially shorten T1, generating high signal intensity in GREs. Because IPH appears as high signal intensity in MRIPH and the surface effects of calcium can potentially shorten T1 of surrounding water protons, the purpose of this study was to evaluate whether the high signal intensity seen on MRIPH could be attributed solely to IPH and not calcification. MATERIALS AND METHODS: Eleven patients undergoing carotid endarterectomy were imaged by using MRIPH. Calcification was assessed by scanning respective endarterectomy specimens with a tabletop MicroCT. MRIPH/MicroCT correlation used an 8-segment template. Two readers evaluated images from both modalities. Agreement between MRIPH/MicroCT was measured by calculating Cohen κ. RESULTS: High signal intensity was seen in 58.8% and 68.9% (readers 1 and 2, respectively) of MRIPH segments, whereas calcification was seen in 44.7% and 32.1% (readers 1 and 2, respectively) of MicroCT segments. High signal intensity seen by MRIPH showed very good but inverse agreement to calcification (κ = -0.90; P < .0001, 95% CI, -0.93 to -0.86, reader 1; and κ = -0.74; P < .0001; 95% CI, -0.81 to -0.69, reader 2). Most interesting, high signal intensity demonstrated excellent agreement with lack of calcification on MicroCT (κ = 0.92; P < .0001; 95% CI, 0.89-0.94, reader 1; and κ = 0.97; P < .0001; 95% CI, 0.96-0.99, reader 2). In a very small number of segments, high signal intensity was seen in MRIPH, and calcification was seen on MicroCT; however, these represented a very small proportion of segments with high signal intensity (5.9% and 1.6%, readers 1 and 2, respectively). CONCLUSIONS: High signal intensity, therefore, reliably identified IPH, known to describe complicated plaque, rather than calcification, which is increasingly recognized as identifying more stable vascular disease.


Assuntos
Calcinose/patologia , Doenças das Artérias Carótidas/patologia , Hemorragia Cerebral/patologia , Imagem Ecoplanar/métodos , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/cirurgia , Hemorragia Cerebral/diagnóstico por imagem , Hemorragia Cerebral/cirurgia , Imagem Ecoplanar/normas , Endarterectomia das Carótidas , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Microtomografia por Raio-X
18.
AJNR Am J Neuroradiol ; 30(7): 1435-9, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19321627

RESUMO

BACKGROUND AND PURPOSE: The CT grading system for otosclerosis was proposed by Symons and Fanning in 2005. The purpose of this study was to determine if this CT grading system has high interobserver and intraobserver agreement. MATERIALS AND METHODS: All 997 petrous bone CTs performed between December 2000 and September 2007 were reviewed. A total of 81 subjects had CT evidence of otosclerosis on at least 1 side; 68 (84%) had bilateral disease. Because otosclerosis was clinically suspected in both ears of all 81 subjects even if CT evidence was only unilateral, both petrous bones (162 in total) were included. Two blinded neuroradiologists independently graded disease severity using the Symons/Fanning grading system: grade 1, solely fenestral; grade 2, patchy localized cochlear disease (with or without fenestral involvement) to either the basal cochlear turn (grade 2A), or the middle/apical turns (grade 2B), or both the basal turn and the middle/apical turns (grade 2C); and grade 3, diffuse confluent cochlear involvement (with or without fenestral involvement). One reviewer repeat-graded the petrous bone CTs to determine intraobserver agreement with a 7-month intervening delay to mitigate recall bias. RESULTS: There were 154 agreements (95%) comparing the first grading of reviewer 1 with that of reviewer 2 (kappa = 0.93). When the repeat 7-month delayed grading of reviewer 1 was compared with that of reviewer 2, there were 151 (93%) agreements (kappa = 0.90). Therefore, mean interobserver agreement was excellent (mean kappa = 0.92). There were 155 agreements (96%) comparing the original grading of reviewer 1 with the delayed grading (kappa = 0.94), demonstrating excellent intraobserver agreement. CONCLUSIONS: A recently published CT grading for otosclerosis on the basis of location of involvement yielded excellent interobserver and intraobserver agreement.


Assuntos
Otosclerose/diagnóstico por imagem , Osso Petroso/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Curr Oncol ; 16(1): 62-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19229374

RESUMO

Brain metastasis is increasingly common, affecting 20%-40% of cancer patients. After diagnosis, survival is usually limited to months in these patients. Treatment for brain metastasis includes whole-brain radiation therapy, surgical resection, or both. These treatments aim to slow progression of disease and to improve or maintain neurologic function and quality of life.Although less common, primary brain tumours produce symptoms that are similar to those of brain metastasis. Glioblastoma, the most common malignant tumour of the brain, has a median survival of less than 12 months. Patients are often treated with surgical resection followed by radical radiation therapy and chemotherapy.Here, we present 2 separate cases of lesions in the brain radiologically compatible with brain metastasis. In both cases, no primary cancer site had been established, and neurosurgical intervention was sought to obtain a pathologic diagnosis. Both cases were pathologically confirmed as glioblastoma. These cases demonstrate the importance of differentiation between brain metastases and primary brain tumours to ensure that the appropriate management strategy is implemented.

20.
AJNR Am J Neuroradiol ; 30(3): 525-31, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19147716

RESUMO

BACKGROUND AND PURPOSE: Clot extent, location, and collateral integrity are important determinants of outcome in acute stroke. We hypothesized that a novel clot burden score (CBS) and collateral score (CS) are important determinants of clinical and radiologic outcomes and serve as useful additional stroke outcome predictors. MATERIALS AND METHODS: One hundred twenty-one patients with anterior circulation infarct presenting within 3 hours of stroke onset were reviewed. The Spearman correlation was performed to assess the correlation between CBS and CS and clinical and radiologic outcome measures. Patients were dichotomized by using a 90-day modified Rankin scale (mRS) score. Uni- and multivariate logistic regression models were used to assess variables predicting favorable clinical and radiologic outcomes. Receiver operating characteristic and intraclass correlation coefficient (ICC) analyses were performed. Diagnostic performance of a CBS threshold of >6 was assessed. RESULTS: There were 85 patients (mean age, 70 +/- 14.5 years). Patients with higher CBS and CS demonstrated smaller pretreatment perfusion defects and final infarct volume and better clinical outcome (all, P < .01). CBS (P = .009) and recanalization (P = .015) independently predicted favorable outcome. A CBS >6 predicted good clinical outcome with an area under the curve of 0.75 (95% confidence interval [CI], 0.65-0.84; P = .0001), sensitivity of 73.0 (95% CI, 55.9-86.2), and specificity of 64.6 (95% CI, 49.5-77.8). The recanalization rate with intravenous recombinant tissue plasminogen activator was higher in patients with CBS >6 (P = .04; odds ratio, 3.2; 95% CI, 1.1-9.4). The ICC was 0.97 (95% CI, 0.95-0.98) and 0.87 (95% CI, 0.80-0.91) for CBS and CS, respectively. CONCLUSIONS: CBS and CS are useful additional markers predicting clinical and radiologic outcomes.


Assuntos
Angiografia Cerebral/métodos , Circulação Colateral , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Trombose Intracraniana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Revascularização Cerebral , Circulação Cerebrovascular , Feminino , Humanos , Infarto da Artéria Cerebral Média/terapia , Trombose Intracraniana/terapia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...