Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Polymers (Basel) ; 16(5)2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38475274

RESUMO

In recent years, composite resin materials have been the most frequently used materials for direct restorations of posterior teeth. These materials have some clinically relevant limitations due to their lack of fracture toughness, especially when used in larger cavities with high volume factors or when utilized as direct or indirect overlays or crown restorations. Recently, short-fiber-reinforced composite materials have been used in bi-structure restorations as a dentine substituting material due to their superior mechanical properties; however, there is no scientific consensus as to whether they can be used as full restorations. The aim of our review was to examine the available literature and gather scientific evidence on this matter. Two independent authors performed a thorough literature search using PubMed and ScienceDirect up until December 2023. This study followed the PRISMA guidelines, and the risk of bias was assessed using the QUIN tool. The authors selected in vitro studies that used short-fiber-reinforced composite materials as complete restorations, with a conventional composite material as a comparison group. Out of 2079 potentially relevant articles, 16 met our inclusion criteria. All of the included studies reported that the usage of short-fiber-reinforced composites improved the restoration's load-bearing capacity. Fifteen of the included publications examined the fracture pattern, and thirteen of them reported a more favorable fracture outcome for the short-fiber-reinforced group. Only one article reported a more favorable fracture pattern for the control group; however, the difference between groups was not significant. Within the limitations of this review, the evidence suggests that short-fiber-reinforced composites can be used effectively as complete restorations to reinforce structurally compromised teeth.

2.
J Nucl Med ; 65(3): 446-452, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38238040

RESUMO

This study evaluated the potential to reduce the scan duration in dopamine transporter (DAT) SPECT when using a second-generation multiple-pinhole (MPH) collimator designed for brain SPECT with improved count sensitivity and improved spatial resolution compared with parallel-hole and fanbeam collimators. Methods: The retrospective study included 640 consecutive clinical DAT SPECT studies that had been acquired in list mode with a triple-head SPECT system with MPH collimators and a 30-min net scan duration after injection of 181 ± 10 MBq of [123I]FP-CIT. Raw data corresponding to scan durations of 20, 15, 12, 8, 6, and 4 min were obtained by restricting the events to a proportionally reduced time interval of the list-mode data for each projection angle. SPECT images were reconstructed iteratively with the same parameter settings irrespective of scan duration. The resulting 5,120 SPECT images were assessed for a neurodegeneration-typical reduction in striatal signal by visual assessment, conventional specific binding ratio analysis, and a deep convolutional neural network trained on 30-min scans. Results: Regarding visual interpretation, image quality was considered diagnostic for all 640 patients down to a 12-min scan duration. The proportion of discrepant visual interpretations between 30 and 12 min (1.2%) was not larger than the proportion of discrepant visual interpretations between 2 reading sessions of the same reader at a 30-min scan duration (1.5%). Agreement with the putamen specific binding ratio from the 30-min images was better than expected for 5% test-retest variability down to a 10-min scan duration. A relevant change in convolutional neural network-based automatic classification was observed at a 6-min scan duration or less. Conclusion: The triple-head SPECT system with MPH collimators allows reliable DAT SPECT after administration of about 180 MBq of [123I]FP-CIT with a 12-min scan duration.


Assuntos
Proteínas da Membrana Plasmática de Transporte de Dopamina , Tomografia Computadorizada de Emissão de Fóton Único , Humanos , Proteínas da Membrana Plasmática de Transporte de Dopamina/metabolismo , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tropanos
3.
BMC Psychol ; 12(1): 45, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267998

RESUMO

BACKGROUND: Over the last century, technological progress has been tremendous, and technological advancement is reflected in the development of medicine. This research assessed attitudes towards surgical robots and identified correlations with willingness to participate in robotic surgery based on factors influencing trust in automated systems. METHOD: Using data from a survey, which included the Multi-dimensional Robot Attitude Scale (MdRAS) and a questionnaire consisting of attitude statements regarding the factors affecting trust in automated systems, the experiment assessed the attitudes of healthcare workers and potential patients towards surgery robots, and attempted to find a correlation between these attitudes, age, and gender. RESULTS AND CONCLUSION: Statistical evaluation of the responses (N = 197) showed that positive attitude towards surgical robots showed a high correlation with the willingness to participate in robotic surgery and gave the strongest correlations with the MdRAS utility and negative attitude towards robots subscales. For the assessment of willingness, the MdRAS subscales alone did not provide a strong enough correlation. All factors examined showed a significant correlation with participation. Having faith in the surgery robot, the propensity to trust technology, the designer's reputation, the ease of work that a surgical robot provides, positive experience with robots, and believing the surgeon is competent at operating the machine seemed to have been the most important positive correlations, while fear of errors gave the highest negative correlation. The healthcare workers and potential patients showed significant differences in the subscales of the questionnaire perceived risk and knowledge but no significant difference in the characteristics of the surgical robot. There was no difference in willingness to participate between the samples. Age did not show a significant correlation with the score achieved and willingness in any of the samples. Significant differences were found between male and female respondents, with men having more positive attitudes and being more likely to participate in surgeries using surgery robots than women. As a result, the research potentially sheds light on the factors that need to be considered when building trust in robotic surgery.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Feminino , Masculino , Confiança , Medo
4.
Int J Mol Sci ; 24(23)2023 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-38069018

RESUMO

The proper regeneration of vessel anastomoses in microvascular surgery is crucial for surgical safety. Pituitary adenylate cyclase-activating polypeptide (PACAP) can aid healing by decreasing inflammation, apoptosis and oxidative stress. In addition to hematological and hemorheological tests, we examined the biomechanical and histological features of vascular anastomoses with or without PACAP addition and/or using a hemostatic sponge (HS). End-to-end anastomoses were established on the right femoral arteries of rats. On the 21st postoperative day, femoral arteries were surgically removed for evaluation of tensile strength and for histological and molecular biological examination. Effects of PACAP were also investigated in tissue culture in vitro to avoid the effects of PACAP degrading enzymes. Surgical trauma and PACAP absorption altered laboratory parameters; most notably, the erythrocyte deformability decreased. Arterial wall thickness showed a reduction in the presence of HS, which was compensated by PACAP in both the tunica media and adventitia in vivo. The administration of PACAP elevated these parameters in vitro. In conclusion, the application of the neuropeptide augmented elastin expression while HS reduced it, but no significant alterations were detected in collagen type I expression. Elasticity and tensile strength increased in the PACAP group, while it decreased in the HS decreased. Their combined use was beneficial for vascular regeneration.


Assuntos
Hemostáticos , Polipeptídeo Hipofisário Ativador de Adenilato Ciclase , Ratos , Animais , Polipeptídeo Hipofisário Ativador de Adenilato Ciclase/farmacologia , Hemostáticos/farmacologia , Receptores de Polipeptídeo Hipofisário Ativador de Adenilato Ciclase/metabolismo , Receptores Tipo I de Polipeptídeo Intestinal Vasoativo/metabolismo
5.
J Homosex ; : 1-24, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37934474

RESUMO

Tourism plays a key role for gay people, as it is not only a way to escape from work, but also a source of liberation and self-embracement. This role can be particularly valued in societies and political environments that are perceived as hostile toward this group. The present study examines the travel motivations and habits of gay and lesbian people, based on a questionnaire sample of 1473 respondents. The results show that for this group, but especially for women, acceptance and an open culture are of paramount importance when choosing a destination. In contrast, services and events specifically targeted at this sector, which are popular in the Western world, do not typically influence decision-making (they tend to be more attractive to women). Sex per se is not a travel motivator for this group, but is an important feature of travel for men. In addition to gender, the services and activities that an individual engages in while traveling are influenced by the degree of their sexual embracement, the place of residence and the company with which the individual travels.

6.
Muscle Nerve ; 67(5): 371-377, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36879542

RESUMO

INTRODUCTION/AIMS: Vaccination against coronavirus disease 2019 (COVID-19) is relatively safe in patients with idiopathic inflammatory myopathies (IIM); however, myositis flares following vaccination have been poorly studied. We aimed to evaluate the frequency, features, and outcomes of disease relapses in patients with IIM following COVID-19 vaccination. METHODS: A cohort of 176 IIM patients were interviewed after the third wave of the COVID-19 pandemic and followed prospectively. Relapses were determined using the disease state criteria and the outcome of the flares with myositis response criteria, calculating the total improvement score (TIS). RESULTS: A total of 146 (82.9%) patients received a vaccination, 17/146 (11.6%) patients had a relapse within 3 mo, and 13/146 (8.9%) patients within 1 mo. The relapse rate of unvaccinated patients was 3.3%. Three months after the post-vaccination relapses, 70.6% of the patients (12/17) achieved an improvement of disease activity (average TIS score: 30 ± 15.81; seven minor, five moderate, and zero major improvements). Six months after flares improvement was detected in 15/17(88.2%) of relapsed patients (average TIS score: 43.1 ± 19.53; 3 minimal, 8 moderate, and 4 major). Forward stepwise logistic regression analysis revealed that the active state of myositis at the time of injection (p < .0001; odds ratio, 33; confidence interval, 9-120) was significantly associated with the occurrence of a relapse. DISCUSSION: A minority of the vaccinated IIM patients had a confirmed disease flare after COVID-19 vaccination and the majority of the relapses improved after individualized treatment. An active disease state at the time of vaccination probably contributes to the increased risk of a post vaccination myositis flare.


Assuntos
COVID-19 , Miosite , Humanos , Vacinas contra COVID-19/uso terapêutico , Incidência , Pandemias , COVID-19/prevenção & controle , COVID-19/epidemiologia , Miosite/epidemiologia , Doença Crônica , Recidiva , Vacinação
7.
Heliyon ; 9(3): e14336, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36938405

RESUMO

Objectives: Helicopter emergency medical services (HEMS) have been integral to healthcare systems in developed countries and are becoming more relevant in developing countries. There is extremely scarce information available regarding the typical cost structure and dynamics of HEMS operation; thus, the limitation of knowledge may limit the shapers of national healthcare policy and potential private operators in starting such a service. This study aims to present the cost dynamics of HEMS operation. Methods: A systematic literature review was performed on open-source studies to obtain appropriate data. International benchmarks were found; nevertheless, as Hungarian data did not emerge, a recent investment into HEMS service was analyzed based on publicly available data from the Hungarian Air Ambulance and affiliated companies. The resulting cost base was allocated per flight hour, and a scenario was established with Western European (German) wages and salaries to challenge the aforementioned international examples. Results: The average cost of operation is calculated at EUR 2488 per hour or EUR 41.5 per airborne minute based on average mission duration. This result is quite below the German example of ca. EUR 55.4 per airborne minute and even less than the US and Australian examples, but once the costing model was recalculated with German salaries, the result was extremely similar to the literature review. Nevertheless, comparable international figures need further research, as ownership structure, cost allocation method, and accounting regimes may dramatically impact the cost per airborne minute. Conclusion: The cost of EUR 2488 per flight hour is a good indicator for an hourly rate of operations; however, when deciding on establishing such a service, the model needs to be adjusted for comparable salaries and foreign exchange rates. Nevertheless, if the number of flight hours can be well estimated, the yearly funding needs can be accurately determined using it.

8.
Polymers (Basel) ; 15(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36987124

RESUMO

The aim of this research was to evaluate the mechanical impact of utilizing different fiber-reinforced composite (FRC) systems to reinforce inlay-retained bridges in dissected lower molars with different levels of periodontal support. A total of 24 lower first molars and 24 lower second premolars were included in this study. The distal canal of all molars received endodontic treatment. After root canal treatment, the teeth were dissected, and only the distal halves were kept. Standardized class II occluso-distal (OD) (premolars) and mesio-occlusal (MO) (dissected molars) cavities were prepared in all teeth, and premolar-molar units were created. The units were randomly distributed among four groups (n = six/group). With the aid of a transparent silicone index, direct inlay-retained composite bridges were fabricated. In Groups 1 and 2, both discontinuous (everX Flow) and continuous (everStick C&B) fibers were used for reinforcement, while in Groups 3 and 4, only discontinuous fibers (everX Flow) were used. The restored units were embedded in methacrylate resin, simulating either physiological periodontal conditions or furcation involvement. Subsequently, all units underwent fatigue survival testing in a cyclic loading machine until fracture, or a total of 40,000 cycles. Kaplan-Meyer survival analyses were conducted, followed by pairwise log-rank post hoc comparisons. Fracture patterns were evaluated visually and with scanning electron microscopy. In terms of survival, Group 2 performed significantly better than Groups 3 and 4 (p < 0.05), while there was no significant difference between the other groups. In the case of impaired periodontal support, a combination of both continuous and discontinuous short FRC systems increased the fatigue resistance of direct inlay-retained composite bridges compared to bridges that only contained short fibers. Such a difference was not found in the case of sound periodontal support between the two different bridges.

9.
EJNMMI Phys ; 10(1): 24, 2023 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-36964406

RESUMO

BACKGROUND: In this study we evaluated the imaging capabilities of a novel Multi-pinhole collimator (MPH-Cardiac) specially designed for nuclear cardiology imaging on a Triple-NaI-detector based SPECT/CT system. METHODS: 99mTc point source measurements covering the field of view (FOV) were used to determine tomographic sensitivity (TSpointsource) and spatial resolution. Organ-size tomographic sensitivity (TSorgan) was measured with a left ventricle (LV) phantom filled with typical myocardial activity of a patient scan. Reconstructed image uniformity was measured with a 140 mm diameter uniform cylinder phantom. Using the LV phantom once filled with 99mTc and after with 123I, Contrast-to-noise ratio (CNR) was measured on the reconstructed images by ROI analysis on the myocardium activity and on the LV cavity. Furthermore, a polar map analysis was performed determining Spill-Over-Ratio in water (SORwater) and image noise. The results were compared with that of a dual-head parallel-hole low energy high resolution (LEHR) collimator system. A patient with suspected coronary artery disease (CAD) was scanned on the LEHR system using local protocol of 16 min total acquisition time, followed by a 4-min MPH-Cardiac scan. RESULTS: Peak TSpointsource was found to be 1013 cps/MBq in the axial center of the FOV while it was decreasing toward the radial edges. TSorgan in the CFOV was found to be 134 cps/MBq and 700 cps/MBq for the LEHR and MPH-Cardiac, respectively. Average spatial resolution throughout the FOV was 4.38 mm FWHM for the MPH-Cardiac collimator. Reconstructed image uniformity values were found to be 0.292% versus 0.214% for the LEHR and MPH-Cardiac measurements, respectively. CNR was found to be higher in case of MPH-Cardiac than for LEHR in case of 99mTc (15.5 vs. 11.7) as well as for 123I (13.5 vs. 8.3). SORwater values were found to be 28.83% and 21.1% for the 99mTc measurements, and 31.44% and 24.33% for the 123I measurements for LEHR and MPH-Cardiac, respectively. Pixel noise of the 99mTc polar maps resulted in values of 0.38% and 0.24% and of the 123I polar maps 0.62% and 0.21% for LEHR and MPH-Cardiac, respectively. Visually interpreting the patient scan images, MPH-Cardiac resulted in better image contrast compared to the LEHR technique with four times shorter scan duration. CONCLUSIONS: The significant image quality improvement achieved with dedicated MPH-Cardiac collimator on triple head SPECT/CT system paves the way for short acquisition and low-dose cardiovascular SPECT applications.

10.
Clin Oral Investig ; 27(5): 2003-2011, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36814029

RESUMO

OBJECTIVE: The purpose was to evaluate the crack formation associated with different direct restorative procedures of the utilized resin composites (RC) right after and 1 week later of the restoration. MATERIALS AND METHODS: Eighty intact, crack-free third molars with standard MOD cavities were included in this in vitro study and randomly divided into four groups of 20 each. After adhesive treatment, the cavities were restored either with bulk (group 1) or layered (group 2) short-fiber-reinforced resin composites (SFRC); bulk-fill RC (group 3); and layered conventional RC (control). Right after the polymerization and a week later, crack evaluation on the outer surface of the remaining cavity walls was performed with a transillumination method utilizing the D-Light Pro (GC Europe) with the "detection mode." Between- and within-groups comparisons Kruskal-Wallis and Wilcoxon tests were used, respectively. RESULTS: Post-polymerization crack evaluation showed significantly lower crack formation in SFRC groups compared to the control (p<0.001). There was no significant difference within SFRC groups and non-SFRC groups (p=1.00 and p=0.11, respectively). Within group comparison revealed significantly higher number of cracks in all groups after 1 week (p≤0.001), however, only the control group differed significantly from all the other groups (p≤0.003). CONCLUSIONS: Post-polymerization shrinkage induced further crack formation in the tooth 1 week after the restoration. SFRC was less prone to shrinkage-related crack formation during the restorative procedure; however, after 1 week, besides SFRC, bulk-fill RC also showed less prone to polymerization shrinkage-related crack formation than layered composite fillings. CLINICAL RELEVANCE: SRFC can decrease the shrinkage stress-induced crack formation in MOD cavities.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Humanos , Resinas Compostas , Assistência Odontológica , Cárie Dentária/terapia , Restauração Dentária Permanente/métodos , Análise do Estresse Dentário , Teste de Materiais , Polimerização
11.
Clin Exp Rheumatol ; 41(2): 254-260, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35894072

RESUMO

OBJECTIVES: Pandemic caused by coronavirus disease (COVID-19) determines the life of clinicians and patients since 2 years. We have a lot of information about disease course, treatment and protection against virus, but less on the prognosis of infection in patients with idiopathic inflammatory myopathies (IIM). Also few data are available on triggered humoral response and side effects after vaccination. METHODS: Our goal was to assess by a retrospective cross-sectional study the above data in our cohort (176 IIM patients) by identifying COVID-19 positive patients and follow disease course. Incidence and complications of vaccination were determined by questionnaires. 101 patients volunteered for complex blood test. RESULTS: By June 1st, 2021 significantly higher incidence of COVID 19 infections (34.7%) were identified comparing to the national prevalence (8.2%). A third of these infections occurred asymptomatically or mild. Patients requiring hospitalisation had a significantly longer disease duration and a higher incidence of anti-Jo-1 antibody. All patients infected by COVID-19 became seropositive regardless the immunosuppressive therapy or symptoms severity. 54.3% of the patients received anti-COVID-19 vaccine. 72.3% of patients became seropositive after vaccination. Higher antibody titer against spike protein was detected after Pfizer-BioNTech vaccination compared to others. Patients receiving steroid therapy had decreased post-vaccination antibody response compared to those without steroid treatment. No major post-vaccination infection was observed. CONCLUSIONS: Based on our results, myositis may be associated with an increased risk of COVID-19 infection. Independent risk factor for hospitalisation are longer disease duration and anti-Jo1 positivity. Anti-SARS-CoV2 vaccines seem safe and tolerable and strongly recommended for that population.


Assuntos
COVID-19 , Pandemias , Humanos , Estudos Transversais , Estudos Retrospectivos , Progressão da Doença , Esteroides
12.
J Fungi (Basel) ; 8(10)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36294669

RESUMO

Mycotoxins originating in the preharvest period represent a less studied research problem, even though they are of the utmost practical significance in maize production, determining marketability (within EU limits), and storage ability, competitiveness, and profit rate. In this study, 18-23 commercial hybrids were tested between 2014 and 2021. Natural infection from Fusarium spp. was higher than 1.5%, and for Aspergillus spp. this was normally 0.01% or 0, much lower than would be considered as severe infection. In spite of this, many hybrids provided far higher toxin contamination than regulations allow. The maximum preharvest aflatoxin B1 was in 2020 (at 2286 µg/kg), and, in several cases, the value was higher than 1000 µg/kg. The hybrid differences were large. In Hungary, the presence of field-originated aflatoxin B1 was continuous, with three AFB1 epidemics in the 8 years. The highest DON contamination was in 2014 (at 27 mg/kg), and a detectable DON level was found in every hybrid. FUMB1+B2 were the highest in 2014 (at 45.78 mg/kg). At these low infection levels, correlations between visual symptoms and toxin contaminations were mostly non-significant, so it is not feasible to draw a conclusion about toxin contamination from ear rot coverage alone. The toxin contamination of hybrids for a percentage of visual infection is highly variable, and only toxin data can decide about food safety. Hybrids with no visual symptoms and high AFB1 contamination were also identified. Preharvest control, including breeding and variety registration, is therefore of the utmost importance to all three pathogens. Even natural ear rot and toxin data do not prove differences in resistance, so a high ear rot or toxin contamination level should be considered as a risk factor for hybrids. The toxin control of freshly harvested grain is vital for separating healthy and contaminated lots. In addition, proper growing and storage conditions must be ensured to protect the feed safety of the grain.

13.
Toxins (Basel) ; 14(9)2022 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-36136521

RESUMO

Gibberella ear rot (GER) is an important fungal ear pathogen of maize that causes ear rot and toxin contamination. Most previous works have only dealt with the visual symptoms, but not with the toxins of GER. As food and feed safety rankings depend on toxin contamination, including deoxynivalenol (DON), without toxins, nothing can be said about the risks involved in food and feed quality. Therefore, three susceptible, three medium-susceptible, and three medium-resistant mother lines were crossed with three testers with differing degrees of resistance and tested between 2017-2020. Two plot replicates and two fungal strains were used separately. The highest heterosis was found at the GER% with a 13% increase across 27 hybrids, including 7 hybrids showing negative heterosis (a higher hybrid performance above the parental mean), with a variance ranging between 63.5 and -55.4. For DON, the mean heterosis was negative at -35%, and only 10 of the 27 hybrids showed a positive heterosis. The mean heterosis for DON contamination, at 1% GER, was again negative (-19.6%, varying between 85% and 224%). Only 17 hybrids showed heterosis, while that of the other 17 was rated higher than the parental mean. A positive significant correlation was found only for GER% and DON; the other factors were not significant. Seven hybrids were identified with positive (2) or negative (5) heterosis for all traits, while the rest varied. For DON and GER, only 13 provided identical (positive or negative) heteroses. The majority of the hybrids appeared to diverge in the regulation of the three traits. The stability of GER and DON (variance across eight data sets) did not agree-only half of the genotypes responded similarly for the two traits. The genetic background for this trait is unknown, and there was no general agreement between traits. Thus, without toxin analyses, the evaluation of food safety is not possible. The variety in degrees of resistance to toxigenic fungi and resistance to toxin accumulation is an inevitable factor.


Assuntos
Fusarium , Gibberella , Tricotecenos , Gibberella/genética , Doenças das Plantas/genética , Doenças das Plantas/microbiologia , Zea mays/microbiologia
14.
Sci Rep ; 12(1): 13312, 2022 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-35922644

RESUMO

The goal of the present study is to examine the cognitive/affective physiological correlates of passenger travel experience in autonomously driven transportation systems. We investigated the social acceptance and cognitive aspects of self-driving technology by measuring physiological responses in real-world experimental settings using eye-tracking and EEG measures simultaneously on 38 volunteers. A typical test run included human-driven (Human) and Autonomous conditions in the same vehicle, in a safe environment. In the spectrum analysis of the eye-tracking data we found significant differences in the complex patterns of eye movements: the structure of movements of different magnitudes were less variable in the Autonomous drive condition. EEG data revealed less positive affectivity in the Autonomous condition compared to the human-driven condition while arousal did not differ between the two conditions. These preliminary findings reinforced our initial hypothesis that passenger experience in human and machine navigated conditions entail different physiological and psychological correlates, and those differences are accessible using state of the art in-world measurements. These useful dimensions of passenger experience may serve as a source of information both for the improvement and design of self-navigating technology and for market-related concerns.


Assuntos
Condução de Veículo , Status Social , Automação , Condução de Veículo/psicologia , Movimentos Oculares , Humanos , Tecnologia
15.
Biomedicines ; 10(7)2022 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-35884813

RESUMO

Vascular graft maturation is associated with blood flow characteristics, such as velocity, pressure, vorticity, and wall shear stress (WSS). Many studies examined these factors separately. We aimed to examine the remodeling of arterio-venous fistulas (AVFs) and loop-shaped venous interposition grafts, together with 3D flow simulation. Thirty male Wistar rats were randomly and equally divided into sham-operated, AVF, and loop-shaped venous graft (Loop) groups, using the femoral and superficial inferior epigastric vessels for anastomoses. Five weeks after surgery, the vessels were removed for histological evaluation, or plastic castings were made and scanned for 3D flow simulation. Remodeling of AVF and looped grafts was complete in 5 weeks. Histology showed heterogeneous morphology depending on the distribution of intraluminal pressure and WSS. In the Loop group, an asymmetrical WSS distribution coincided with the intima hyperplasia spots. The tunica media was enlarged only when both pressure and WSS were high. The 3D flow simulation correlated with the histological findings, identifying "hotspots" for intimal hyperplasia formation, suggesting a predictive value. These observations can be useful for microvascular research and for quality control in microsurgical training.

16.
Orv Hetil ; 163(25): 1005-1011, 2022 Jun 19.
Artigo em Húngaro | MEDLINE | ID: mdl-35895551

RESUMO

Imaging techniques play a primary role in the assessment of the severity of periodontal diseases. However, X-rays are often insufficient to reveal their real nature and extent. One of the most difficult questions to decide is the exact shape and extent of the bony defect, as it undoubtedly poses a major impact on our choice of therapy. CBCT (cone-beam computed tomography) images show the nature of the defect with high accuracy. The three-dimensional (3D) view allows us to examine not only the slices corresponding to the planes, however, their quality and usability is often unsatisfactory. One option for better visualization and analysis is the 3D model, which is created with the help of CBCT and segmentation. Here, the segmented elements (alveolar bone, teeth, defect and other anatomical structures, etc.) appear as real 3D objects and their size, shape and relative position can be examined much better than with the aforementioned diagnostic tools. It gives a preliminary view of the defect, the number of existing bony walls, and allows us to select the most appropriate treatment. Our aim is to demonstrate the role of this method (segmentation) in periodontal surgery through a case presentation. The method has already been used in many other fields of medicine. Its continuous improvement and comprehensive fields of application make it promising in the future and it might open a new horizon in diagnostic imaging.


Assuntos
Digitalis , Doenças Periodontais , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Doenças Periodontais/diagnóstico por imagem
17.
J Fungi (Basel) ; 8(3)2022 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-35330295

RESUMO

Resistance to toxigenic fungi and their toxins in maize is a highly important research topic, as mean global losses are estimated at about 10% of the yield. Resistance and toxin data of the hybrids are mostly not given, so farmers are not informed about the food safety risks of their grown hybrids. According to the findings aflatoxin regularly occurs at preharvest in Hungary and possibly other countries in the region can be jeopardized. We tested, with an improved methodology (two isolates, three pathogens, and a toxin control), 18 commercial hybrids (2017-2020) for kernel resistance (%), and for toxin contamination separately by two-two isolates of F. graminearum, F. verticillioides (mg/kg), and A. flavus (µg/kg). The preharvest toxin contamination was measured in the controls. Highly significant kernel resistance and toxin content differences were identified between hybrids to the different fungi. Extreme high toxin production was found for each toxic species. Only about 10-15% of the hybrids showed higher resistance to the fungal species tested and lower contamination level of their toxins. The lacking correlations between resistance to different fungi and toxins suggest that resistance to different fungi and response to toxin contamination inherits independently, so a toxin analysis is necessary. For safety risk estimation, separated artificial and natural kernel infection and toxin data are needed against all pathogens. Higher resistance to A. flavus and F. verticillioides stabilizes or improves feed safety in hot and dry summers, balancing the harmful effect of climate changes. Resistance and toxin tests during variety registration is an utmost necessity. The exclusion of susceptible or highly susceptible hybrids from commercial production results in reduced toxin contamination.

18.
J Mech Behav Biomed Mater ; 129: 105143, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35272149

RESUMO

OBJECTIVES: The aim of this study was to evaluate the effect of the amount of periodontal support and the presence or absence of root amputation on the fracture resistance of intracoronally splinted maxillary molar teeth. MATERIALS AND METHODS: 48 extracted human upper first molars and 48 s premolars were included in the study. All teeth underwent standard mesio-occluso-distal (MOD) (molars) and standard occluso-distal (OD) (premolars) cavity preparation. After the preparation, all molars were root canal treated, and 48 molar-premolar units were created by intracoronal splinting. The units were randomly divided into 4 groups (Groups A-D, 12 units per group): in Groups C and D, the disto-buccal (DB) roots of the molars were amputated, while in Groups A and B, no root amputation was performed. All units were embedded in methacrylate resin at different levels: in Groups A and C, at 4 mm apically from the cemento-enamel junction (CEJ), while in Groups B and D, at 6 mm apically from the CEJ, mimicking the different stages of furcation involvement. All units were submitted first to dynamic and then to static, load-to-fracture mechanical testing. Fracture resistance values were recorded fracture mode was analysed. RESULTS: During the load-to-facture test, Groups A and B (without root amputation) were characterized by significantly higher fracture resistance values compared to Groups C and D (with root amputation) (p < 0.05). Regarding fracture mode, irreparable fracture was more frequent in Group D (with root amputation and advanced furcation involvement) than in any other group (n = 8). CONCLUSIONS: Root amputation has a negative effect on the fracture resistance of intracoronally splinted upper first molar-second premolar units with modeled furcation involvement.


Assuntos
Dente Molar , Fraturas dos Dentes , Amputação Cirúrgica , Dente Pré-Molar , Humanos , Dente Molar/cirurgia , Tratamento do Canal Radicular , Raiz Dentária/cirurgia
19.
Metabolites ; 11(11)2021 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-34822434

RESUMO

In trauma and orthopedic surgery, limb ischemia-reperfusion (I/R) remains a great challenge. The effect of preventive protocols, including surgical conditioning approaches, is still controversial. We aimed to examine the effects of local ischemic pre-conditioning (PreC) and post-conditioning (PostC) on limb I/R. Anesthetized rats were randomized into sham-operated (control), I/R (120-min limb ischemia with tourniquet), PreC, or PostC groups (3 × 10-min tourniquet ischemia, 10-min reperfusion intervals). Blood samples were taken before and just after the ischemia, and on the first postoperative week for testing hematological, micro-rheological (erythrocyte deformability and aggregation), and metabolic parameters. Histological samples were also taken. Erythrocyte count, hemoglobin, and hematocrit values decreased, while after a temporary decrease, platelet count increased in I/R groups. Erythrocyte deformability impairment and aggregation enhancement were seen after ischemia, more obviously in the PreC group, and less in PostC. Blood pH decreased in all I/R groups. The elevation of creatinine and lactate concentration was the largest in PostC group. Histology did not reveal important differences. In conclusion, limb I/R caused micro-rheological impairment with hematological and metabolic changes. Ischemic pre- and post-conditioning had additive changes in various manners. Post-conditioning showed better micro-rheological effects. However, by these parameters it cannot be decided which protocol is better.

20.
Sensors (Basel) ; 21(16)2021 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-34450986

RESUMO

Alterations of heart rate variability (HRV) are associated with various (patho)physiological conditions; therefore, HRV analysis has the potential to become a useful diagnostic module of wearable/telemedical devices to support remote cardiovascular/autonomic monitoring. Continuous pulse recordings obtained by photoplethysmography (PPG) can yield pulse rate variability (PRV) indices similar to HRV parameters; however, it is debated whether PRV/HRV parameters are interchangeable. In this study, we assessed the PRV analysis module of a digital arterial PPG-based telemedical system (SCN4ALL). We used Bland-Altman analysis to validate the SCN4ALL PRV algorithm to Kubios Premium software and to determine the agreements between PRV/HRV results calculated from 2-min long PPG and ECG captures recorded simultaneously in healthy individuals (n = 33) at rest and during the cold pressor test, and in diabetic patients (n = 12) at rest. We found an ideal agreement between SCN4ALL and Kubios outputs (bias < 2%). PRV and HRV parameters showed good agreements for interbeat intervals, SDNN, and RMSSD time-domain variables, for total spectral and low-frequency power (LF) frequency-domain variables, and for non-linear parameters in healthy subjects at rest and during cold pressor challenge. In diabetics, good agreements were observed for SDNN, LF, and SD2; and moderate agreement was observed for total power. In conclusion, the SCN4ALL PRV analysis module is a good alternative for HRV analysis for numerous conventional HRV parameters.


Assuntos
Fotopletismografia , Telemedicina , Sistema Nervoso Autônomo , Eletrocardiografia , Frequência Cardíaca , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...