Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
6.
Graefes Arch Clin Exp Ophthalmol ; 255(3): 457-462, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27632214

RESUMO

PURPOSE: Vision loss in central retinal vein occlusion (CRVO) is mostly caused by macular edema (ME) and can be treated with intravitreal bevacizumab injections. The goal of this study was to identify predictive factors for improvement in visual acuity. METHODS: Three hundred and sixteen eyes of six centres having received intravitreal bevacizumab for ME due to CRVO were enrolled in this multicentre, retrospective, interventional case series. The follow-up time was 24 to 48 weeks. Investigated patient characteristics were pretreatment, duration of CRVO prior to the first injection, initial best-corrected visual acuity (BCVA), baseline central retinal thickness as measured by optical coherence tomography, gender, eye, age, comorbidity with glaucoma, systemic hypertension, or diabetes mellitus. RESULTS: Multiple regression analysis confirmed the following baseline predictive factors for an increase in visual acuity: low BCVA (p < 0.001), high CRT (p < 0.02), and treatment naïve patients (p = 0.03). None of the other investigated patient characteristics could be identified as prognostic factors for increase in visual acuity (p > 0.1). CONCLUSIONS: Intravitreal injections of bevacizumab in a routine clinical setting effectively improved and stabilized BCVA in CRVO. Our large multicenter study identified initial BCVA, baseline CRT, and pre-treatment as prognostic factors for visual improvement.


Assuntos
Bevacizumab/administração & dosagem , Recuperação de Função Fisiológica , Oclusão da Veia Retiniana/tratamento farmacológico , Acuidade Visual/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Inibidores da Angiogênese/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Angiofluoresceinografia , Seguimentos , Fundo de Olho , Humanos , Injeções Intravítreas , Edema Macular/diagnóstico , Edema Macular/etiologia , Edema Macular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Prognóstico , Epitélio Pigmentado da Retina/patologia , Oclusão da Veia Retiniana/complicações , Oclusão da Veia Retiniana/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Tomografia de Coerência Óptica , Adulto Jovem
8.
Graefes Arch Clin Exp Ophthalmol ; 254(7): 1419-24, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26892143

RESUMO

BACKGROUND: The custom-made, flexible artificial iris developed by HumanOptics and Koch can reconstruct the anterior segment of patients with aniridia. The aim of this study was to evaluate the long-term clinical outcome and complication spectrum after artificial iris implantation and the role of the embedded fiber mesh in view of specific complications. METHODS: In this retrospective interventional case series, patients received an artificial iris between 2004 and 2013. Only eyes with a minimum follow-up period of 2 years were included. Indications were congenital, traumatic, or iatrogenic aniridia. The artificial iris was used either with or without embedded fiber mesh for partial or full prostheses. RESULTS: We included 34 patients (mean age 48.8 years; SD ±17.2) with a mean follow-up of 50.0 months (SD ±18.9 months). No repositioning of prostheses was necessary. In cases of keratopathy (17.6 %) visual function increased from baseline mean 1.6 logMAR (SD ±0.7) to 1.2 logMAR (SD ±0.7) after artificial iris implantation. The remaining iris tissue darkened during the follow-up in 23.5 % (83.3 % with and 10.7 % without mesh), 8.8 % developed glaucoma (50 % with and 0 % without mesh) and 14.7 % needed consecutive surgery after prostheses implantation (50 % with and 7.1 % without mesh). In three out of seven trauma cases (42.9 %) silicone oil was spilled into the anterior chamber after 2.5 years on average. CONCLUSION: The artificial iris prosthesis revealed a good clinical outcome in terms of long-term stability, cosmetic appearance, visual function, and represents a good functional iris diaphragm for compartmentalisation. Complications such as glaucoma, darkening of iris tissue, and need for consecutive anterior segment surgery are clearly associated with implants with integrated fiber mesh, but not to those without. Hence, the use of full iris prostheses without embedded fiber mesh, even in cases with remnant iris, and the use of slightly smaller implants than officially recommended may be beneficial.


Assuntos
Aniridia/cirurgia , Órgãos Artificiais , Procedimentos Cirúrgicos Oftalmológicos/métodos , Implantação de Prótese/métodos , Acuidade Visual , Adulto , Idoso , Idoso de 80 Anos ou mais , Aniridia/diagnóstico , Aniridia/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
9.
Acta Ophthalmol ; 94(3): 301-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26805757

RESUMO

PURPOSE: Posttraumatic partial or total iris defects often cause significant debilitating glare, photophobia, decreased vision and cosmetic problems. Currently, the best cosmetic results can be obtained with a customized silicone iris prosthesis. However, little is known about the functional results and the rate of complication if this type of iris prosthesis is implanted into severely traumatized eyes. The aim of this study is to analyse the functional and cosmetic outcomes as well as complications after Artificial Iris implantation. METHODS: A consecutive series of 34 patients who received a customized silicone iris prosthesis after severe globe injury with total or sub-total iris loss was analysed retrospectively. Additionally, patients were interviewed regarding change in subjective complaints. RESULTS: Median follow-up was 24 months (range 12.0-48.8). Mean visual acuity prior to Artificial Iris implantation was 1.1 logMAR (range 0.3-2.6). Five patients (15%) had pre-existing glaucoma and eight patients (24%) had pre-existing hypotony. Visual acuity 12 months after surgery was 1.4 logMAR (range 0.2-2.6). Complications included newly diagnosed glaucoma in three eyes (9%) and hypotony in three eyes (9%), persisting intraocular inflammation or macular oedema in seven patients (21%), and corneal endothelial decompensation requiring corneal transplantation in six patients (18%). Patients' satisfaction increased by reducing glare and enhanced cosmetic appearance. CONCLUSION: The customized silicone iris prosthesis is an individualized treatment approach with appealing cosmetic results. Therefore, especially traumatized eyes with highly different posttraumatic conditions could benefit. However, in some patients, the implantation of this device may cause an increase of intraocular pressure, corneal endothelial decompensation or persisting inflammation.


Assuntos
Órgãos Artificiais , Ferimentos Oculares Penetrantes/cirurgia , Complicações Intraoperatórias , Iris/lesões , Complicações Pós-Operatórias , Implantação de Prótese , Elastômeros de Silicone , Seguimentos , Humanos , Satisfação do Paciente , Resultado do Tratamento , Acuidade Visual/fisiologia
10.
Graefes Arch Clin Exp Ophthalmol ; 254(2): 351-4, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26666231

RESUMO

PURPOSE: A modified canaloplasty technique is described that may facilitate the surgical procedure and potentially maximizes the intraocular pressure (IOP)-lowering effect by altering both the trabecular and uveoscleral aqueous outflow. METHODS: The second deeper layer in the modified technique (about 3.5 × 4 mm, Fig. 1a, b) is not prepared in a lamellar fashion, but is cut down full-thickness to the choroid, hence opening the suprachoroidal space. Furthermore, this second deep scleral flap creates an additional aqueous outflow and drainage into the suprachoroidal space, thus possibly lowering the postoperative IOP by improving the natural uveoscleral outflow facility. RESULTS: Seventy-eight eyes operated with this modified technique in the last 12 months were retrospectively analysed. Mean IOP before surgery was 19.10 mmHg and patients applied 3.0 topical medications. Twelve months after surgery, the IOP was 13.5 mmHg and patients applied 1.0 topical medication; 52.6 % of patients did not use any topical therapy. DISCUSSION: The modified dissection canaloplasty technique potentially improves the IOP-lowering effect due to the creation of additional suprachoroidal drainage and simplifies the most complicated step of the surgery, as the scleral spur and the Schlemm's canal can be located using suprachoroidal access.


Assuntos
Humor Aquoso/metabolismo , Corioide/metabolismo , Drenagem/métodos , Cirurgia Filtrante/métodos , Glaucoma/cirurgia , Esclera/cirurgia , Retalhos Cirúrgicos , Dissecação , Implantes para Drenagem de Glaucoma , Humanos , Pressão Intraocular/fisiologia , Implantação de Prótese/métodos , Estudos Retrospectivos , Técnicas de Sutura
12.
Retina ; 34(4): 785-91, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24670999

RESUMO

PURPOSE: To measure the value of augmented reality technology usage to teach the medical students performing binocular indirect ophthalmoscopy. METHODS: Thirty-seven medical students were randomly assigned to the training of binocular indirect ophthalmoscopy either in the conventional way or with augmented reality ophthalmoscopy (ARO). For testing student's skills, they had to examine a real person using a conventional ophthalmoscopy system and draw the optic disk. They also had to fill out a questionnaire. Subjective and objective evaluations were performed. RESULTS: Thirty-seven students were randomly assigned to two groups. Eighteen students were trained with conventional ophthalmoscopy and 19 students with ARO. The questionnaires showed no differences. Performing an objective analysis, the median ophthalmoscopy training score for the conventional ophthalmoscopy group was 1.2 (range, 0.67-2) and showed a significant difference (P < 0.0033) to the ARO group (median 2; range, 0.67-2). CONCLUSION: The study provides evidence that a single ARO training is efficient to improve ophthalmoscopy skills. As the objective analysis showed, the ARO group had a significantly superior performance. Our study also indicates that subjective evaluation of the fundus drawings without systematic analysis is prone to errors.


Assuntos
Competência Clínica/normas , Educação de Graduação em Medicina/normas , Oftalmologia/educação , Oftalmoscopia , Estudantes de Medicina , Interface Usuário-Computador , Avaliação Educacional , Feminino , Humanos , Masculino , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA