Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomater Appl ; 17(1): 45-70, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12222757

RESUMO

We evaluated the extent (luminal coverage) of the endothelial cell (EC) lining/neointimal development and the thromboresistance of electrostatically EC seeded small diameter ChronoFlex-polyurethane vascular grafts. The evaluation consisted of harvesting autologous, canine jugular vein ECs, electrostatically seeding the polyurethane grafts (4-mm I.D., length = 6 cm) with the harvested ECs, implanting the grafts in a canine femoral artery model for four to six weeks, and excising the grafts for histological and scanning electron microscopy evaluations. Results of the histological evaluation (mid-graft region only) indicated that electrostatic EC seeding led to neointimal development and to minimal to no thrombus formation within the EC seeded grafts. The unseeded control grafts resulted in no neointimal development and substantial thrombus formation on the graft luminal surfaces. Scanning electron microscopy examination demonstrated a mature, confluent endothelium with a "cobblestone" appearance on the EC seeded graft luminal surface after six weeks. We conclude that electrostatic EC seeding enhanced the development of a neointima and reduced the incidence of thrombosis in polyurethane grafts implanted in a canine femoral artery model.


Assuntos
Prótese Vascular , Endotélio Vascular/citologia , Poliuretanos , Animais , Cães , Microscopia Eletrônica de Varredura , Eletricidade Estática
2.
Cardiovasc Dis ; 7(3): 278-287, 1980 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15216255

RESUMO

The pumping diaphragm of the Texas Heart Institute (THI) E-Type ALVAD must perform the dual functions of providing a flexible blood interface and isolating the electrical actuator from adjacent fluids. Thus, protection is required against fluid leakage and moisture diffusion to prevent corrosion and damage to electrical actuator components. Average diffusion rates up to 1 ml per day through currently used elastomeric diaphragm materials have been measured during static in-vitro and in-vivo tests. To circumvent this problem, an improved pumping diaphragm has been recently developed for use with the electrically-actuated THI E-Type ALVAD. This trilaminar diaphragm consists of a composite Biomer and butyl rubber design. A.010 inch layer of butyl rubber (characterized by an extremely low diffusion rate for water, approximately 0 ml per day) is positioned between two Biomer layers (.020 and.010 inches in thickness). Initial invitro and in-vivo studies, in calves, indicate that this composite diaphragm provides an excellent barrier to water permeation, without sacrificing biocompatibility or structural integrity under conditions of chronic flexure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA