Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Appl Opt ; 53(24): 5359-66, 2014 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-25321106

RESUMO

A method for using liquid-crystal variable retarders (LCVRs) with continually varying voltage to measure the complete Mueller matrix of a general sample is presented. The LCVRs are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. For the measurement method presented here, the nonlinear voltage-retardance relationship is first measured, and then a linear fit of the known retardance terms to the detected signal is performed. For a gap of air, the measurement error in the Mueller-matrix polarimeter is estimated at 1%-10%, depending on the Mueller-matrix element. Also, we present experimental results for a Glan-Thompson prism polarizer as a test sample, and we use the measured Mueller parameters as functions of the orientation of the optical axes of the polarizer as an indication of the quality of the polarimeter. In addition, results are compared to a typical step-voltage method to measure the Mueller matrix. Both methods give good results.

2.
Rev Sci Instrum ; 85(3): 033104, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689561

RESUMO

We present a method for using liquid-crystal variable retarders (LCVR's) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.

3.
Arq Bras Cardiol ; 63(4): 307-8, 1994 Oct.
Artigo em Português | MEDLINE | ID: mdl-7771950

RESUMO

We presented two cases of falsely elevated CK-MB due to the presence of a type 2 macro CK, showed by isoenzymes electrophoresis. The association of this CK-MB falsely elevated with some digestive diseases are frequent. Quantification of CK isoenzymes by electrophoresis could be indicated in those cases in which the clinical course or ECG changes do not correlate with the CK-MB values.


Assuntos
Colecistite/sangue , Creatina Quinase/sangue , Idoso , Reações Falso-Positivas , Feminino , Humanos , Isoenzimas , Masculino
4.
Br J Anaesth ; 67(3): 335-8, 1991 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1832921

RESUMO

We describe a case of postpartum ruptured dissecting aneurysm of the thoracic aorta, unrelated to the anaesthetic management with extradural anaesthesia. This complication is discussed in detail, as the anaesthetist may be the specialist required to respond to the common presenting symptom of severe back pain.


Assuntos
Anestesia Epidural , Anestesia Obstétrica , Dissecção Aórtica/complicações , Ruptura Aórtica/complicações , Dor nas Costas/etiologia , Transtornos Puerperais/etiologia , Adulto , Aorta Torácica , Cesárea , Feminino , Humanos , Complicações Pós-Operatórias/etiologia , Gravidez , Ruptura Espontânea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA