Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Odontology ; 112(3): 847-854, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38381265

RESUMO

The aim of this study is to evaluate the effect of various disinfection protocols on the cutting efficiency and chemical composition of ProTaper, Twisted File, Twisted File Adaptive, and Hedström files. Four experimental groups (n = 10) were presoaked in either enzymatic solution or 1% sodium hypochlorite for 30 min, followed by either 5 or 15 min of ultrasonic cleaning and then autoclaved. Resin-simulated canals with a single curvature of 38-40° were prepared by each instrument system. Cutting efficiency of each instrument was analyzed by subtracting the final weight from the initial weight of the resin blocks. Chemical compositions were studied by field emission scanning electron microscopy and X-ray energy-dispersive spectrometry. The cutting efficiency of Hedström, ProTaper, and Twisted File instruments decreased compared to their control groups (p < 0.05) whereas it did not change for Twisted File Adaptive. More corrosion was detected with longer ultrasonication time. No difference was observed regarding the pre-soaking media. Disinfection protocols exerted a significant overall effect on the performance of Hedström, ProTaper, and Twisted File instruments. Corrosion, microcracks, and crevices were evident on all tested instruments after disinfection protocols applied. All disinfection protocols, regardless of the pre-soaking media used or the ultrasonic cleaning time applied, have some effect on the cutting efficiency and the surface characteristics of the files.


Assuntos
Desinfecção , Temperatura Alta , Microscopia Eletrônica de Varredura , Preparo de Canal Radicular , Hipoclorito de Sódio , Desinfecção/métodos , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Hipoclorito de Sódio/química , Corrosão , Propriedades de Superfície , Espectrometria por Raios X , Teste de Materiais , Desenho de Equipamento , Instrumentos Odontológicos , Níquel/química
2.
Odovtos (En línea) ; 25(2)ago. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1448740

RESUMO

The first objective of this research was to evaluate the effectiveness of XP-Endo Finisher on dentinal tubule penetration of irrigation solution using confocal laser scanning microscopy. The main purpose of this research was to compare the effect of cold lateral condensation, continuous wave obturation and core-carrier based techniques on sealer penetration. Sixty mandibular premolars were prepared and allocated into two experimental groups (n=30) as the final irrigation technique and obturation technique experiment. In the final irrigation technique experiment, final irrigation was performed with XP-Endo Finisher, passive ultrasonic irrigation (PUI) and conventional needle irrigation (CNI) (n=10). The roots in the obturation technique experiment were also assigned into 3 groups and obturated with cold lateral condensation, continuous-wave obturation and core-carrier techniques (n=10). The most effective activation method, which emerged as a result of the first part of this study, was used as the final irrigation method in the obturation technique experiment. Then, all roots were sectioned in 1-mm-thick slices at 3mm from the apex for scanning. In terms of depth and percentage of material penetration, CNI exhibited significantly the lowest values and no significant difference was found between others. Also, there was no significant difference among obturation methods. In conclusion, XP-Endo Finisher and PUI are more effective than CNI on irrigant penetration. Sealer penetration into dentinal tubules is independent of obturation techniques.


El objetivo principal de esta investigación fue evaluar la eficacia de XP- Endo Finisher en la penetración de la solución de irrigación en los túbulos dentinarios mediante microscopía de láser confocal. Se prepararon sesenta premolares mandibulares y se distribuyeron en dos grupos experimentales (n=30) según el tipo de método de evaluación utilizado. En el experimento de la técnica de irrigación final, la irrigación final se realizó con XP-Endo Finisher, irrigación ultrasónica pasiva (PUI) e irrigación con aguja convencional (CNI) (n=10). Las raíces en el experimento de la técnica de obturación también se asignaron en 3 grupos y se obturaron con técnicas de condensación lateral fría, obturación de onda continua y portador de núcleo (n=10). El método de activación más eficaz, que surgió como resultado de la primera parte de este estudio, se utilizó como método de irrigación final en el experimento de la técnica de obturación. Luego, todas las raíces se seccionaron en muestras de 1mm de espesor. En términos de profundidad y porcentaje de penetración del material, CNI exhibió significativamente los valores más bajos y no se encontraron diferencias significativas entre los demás. Además, no hubo diferencias significativas entre los métodos de obturación. En conclusión, XP-Endo Finisher y PUI son más efectivos que CNI en la penetración del irrigante. La penetración del sellador en los túbulos dentinarios es independiente de las técnicas de obturación.

3.
Lasers Med Sci ; 38(1): 8, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36539627

RESUMO

This study aimed to assess the apical extrusion of sodium hypochlorite in immature teeth caused by needle irrigation, ultrasonic irrigation, EDDY, Er:YAG, and diode lasers. Seventy-five human maxillary anterior teeth were selected. After the apical 3 mm of the roots was resected, the canal lumen was enlarged with #2 to #5 Gates-Glidden burs. The teeth were fixed to the lid of a flat-sided clear plastic container, and the plastic containers were filled with 0.2% agarose gel containing 1 mL of 0.1% m-cresol purple. Then, the specimens were allocated into five groups according to the irrigation activation techniques: needle irrigation, ultrasonic irrigation, EDDY, Er:YAG laser, and diode laser. The apical extrusion of sodium hypochlorite caused the color change in the gel. The containers were digitally photographed, and the percentage of pixels of irrigant extrusion (the color change) in each photograph was calculated. The diode laser group showed a significantly lower percentage of pixels than needle irrigation, EDDY, and Er:YAG laser (p < 0.05). The irrigant extrusion value of the ultrasonic irrigation group was significantly lower than that of the EDDY and Er:YAG laser groups (p < 0.05). There was no significant difference between the other groups (p > 0.05). All the groups caused irrigant extrusion in the immature teeth. The diode laser and ultrasonic irrigation caused less sodium hypochlorite extrusion than EDDY and Er:YAG laser. The needle irrigation showed more irrigant extrusion than the only diode laser group.


Assuntos
Lasers de Estado Sólido , Hipoclorito de Sódio , Humanos , Preparo de Canal Radicular , Lasers Semicondutores/uso terapêutico , Ultrassom , Irrigantes do Canal Radicular , Lasers de Estado Sólido/uso terapêutico , Plásticos , Irrigação Terapêutica , Cavidade Pulpar
4.
Dent Res J (Isfahan) ; 18: 2, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34084289

RESUMO

BACKGROUND: The purpose of this study was to compare the microhardness values of ProRoot mineral trioxide aggregate (MTA), Biodentine, and total fill root repair material (TF-RRM) Putty at varying pH and times. MATERIALS AND METHODS: In this laboratory experiment, materials were mixed and placed in cylinder blocks with internal dimensions of 6 mm × 4 mm. Ten samples of each material were soaked in buffered solutions of butyric acid with 4.4, 5.4, 6.4, and 7.4 pH values and stored at 37°C in 100% humidity. The samples were submitted to the microhardness test at the end of 1 week and then 1 month. Multivariate analysis of variance and Tukey honestly significant difference tests were carried out to compare the mean values at a significance level of P < 0.05. RESULTS: Low pH caused a significant decrease in the microhardness values of all samples. Surface microhardness increased with time (P < 0.0001). The microhardness values of Biodentine were significantly greater than those of ProRoot MTA and TF-RRM putty (P < 0.0001). The lowest microhardness values were recorded for TF-RRM putty groups regardless of the pH of the environment and the evaluation time. CONCLUSION: An acidic environment impaired the surface microhardness of all root repair materials tested. Overall, the mean surface microhardness of TF-RRM Putty was lower than those of ProRoot MTA and Biodentine. Biodentine showed the greatest microhardness values at all pH values, regardless of the evaluation time.

5.
Gen Dent ; 69(3): 73-77, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33908883

RESUMO

Irreversible pulpitis is an acute, brief, and painful condition. Oxytocin, cortisol, and secretory immunoglobulin A (sIgA) are released by the body in response to pain and emotional stress. The aim of this study was to investigate the expression of salivary cortisol, sIgA, and oxytocin among patients with irreversible pulpitis. This was an ethically approved case-control study comparing 90 cases of irreversible pulpitis and 40 healthy individuals. Five study groups were established: nonpregnant female pulpitis, pregnant female pulpitis, male pulpitis, healthy (nonpregnant) female control, and healthy male control. Pregnant women in the first trimester were enrolled in the study. Participants received both clinical and radiographic examinations, completed a simple questionnaire related to food intake, habits, and anxiety, and their pain levels were recorded on a visual analog scale in which 0 represented no pain and 10 represented the worst possible pain. Unstimulated saliva samples were collected to measure oxytocin, sIgA, and cortisol levels. Dental pulp specimens were obtained and stained with hematoxylin and eosin to evaluate the agreement between clinical and histologic pulpal diagnoses. The statistical analysis included analysis of variance and Tukey tests. The majority of patients (37%) recorded a score of 8 (severe pain) on the visual analog scale, while a score of 10 (worst possible pain) was recorded only by pregnant women (3%). There was no statistically significant difference among healthy subjects for all salivary samples. Oxytocin levels increased significantly in nonpregnant (P < 0.5) and pregnant (P < 0.001) women with pulpitis. Cortisol (P < 0.01) and sIgA (P < 0.001) levels were significantly elevated only in pregnant women with pulpitis. The results of the present study indicate that acute dental pain during pregnancy can be considered as a pregnancy risk factor because of the resulting elevated oxytocin and cortisol levels.


Assuntos
Ocitocina , Pulpite , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Dor , Gravidez , Pulpite/complicações , Fatores de Risco
6.
J Endod ; 43(9): 1528-1531, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28712635

RESUMO

INTRODUCTION: The aim of this study was to evaluate and compare the effectiveness of the XP-Endo Finisher (FKG Dentaire, La Chaux-de-Fonds, Switzerland) with passive ultrasonic irrigation (PUI) and needle irrigation in the removal of triple antibiotic paste (TAP) from the straight immature root canals of extracted teeth. METHODS: Thirty-four freshly extracted single-rooted teeth were used. All canals were prepared up to the ProTaper F5 file (Dentsply Maillefer, Ballaigues, Switzerland). Apices were drilled to simulate teeth with immature apices. The canals were filled with TAP, sealed, and incubated at 37°C and 100% humidity for 1 month. Samples were randomly assigned to 3 experimental groups according to the method used for TAP removal: XP-Endo Finisher, PUI, and needle irrigation (n = 10). Then, the roots were split into 2 halves. The amount of TAP residue in the apical portion of each segment was evaluated using a scanning electron microscopy and scored. RESULTS: The amount of remaining TAP was significantly lower in the XP-Endo Finisher group compared with the needle irrigation and PUI groups (P < .05). Between the needle irrigation and PUI groups, there were no statistically significant differences (P > .05). CONCLUSIONS: Within the limitations of this study, the XP-Endo Finisher removed significantly more TAP than needle irrigation and PUI.


Assuntos
Antibacterianos , Cavidade Pulpar , Preparo de Canal Radicular/instrumentação , Desenho de Equipamento , Humanos , Técnicas In Vitro , Pomadas , Distribuição Aleatória
7.
J Endod ; 41(11): 1834-8, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26386947

RESUMO

INTRODUCTION: The aim of this study was to evaluate observer variations and observer reproducibility in the interpretation of periapical health using the Strindberg system, the periapical index (PAI), and the probability index for radiologic assessment of periapical health. METHODS: Four observers read digital periapical images to evaluate the periapical health of 200 root-filled teeth. Each observer evaluated a tooth twice by using the Strindberg system, twice by using the PAI, and twice by using the probability index. Each observation session was held at 1-month intervals. Three scores were used for the evaluations conducted by using the Strindberg system. Both the PAI and the probability index were considered on 5-point scales and were also dichotomized. SPSS for Windows 15.0 software (SPSS Inc, Chicago, IL) was used for data analysis, and intra- and interobserver agreements were described by using kappa statistics. RESULTS: The average kappa values of intra- and interobserver agreement calculated for the Strindberg system were 0.53 and 0.36, respectively. The corresponding average kappa values were calculated as 0.48 and 0.39 for the PAI and 0.45 and 0.30 for the probability index. The highest mean proportion values of intra- and interobserver agreement were observed for the dichotomization of the PAI (88.9% and 87.0%, respectively) followed by the dichotomization of the probability index (86.8% and 82.9%, respectively). CONCLUSIONS: The Strindberg system has lower intraobserver variation compared with the PAI and the probability index, whereas PAI has lower interobserver variation compared with the Strindberg system and the probability index. The dichotomization of the PAI and the probability index provided higher intra- and interobserver agreement values in the radiologic assessment of periapical health.


Assuntos
Doenças Periapicais/diagnóstico por imagem , Radiografia Dentária/métodos , Humanos , Variações Dependentes do Observador
8.
J Endod ; 41(3): 380-4, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25492488

RESUMO

INTRODUCTION: We compared the apical extrusion of sodium hypochlorite delivered with a 27-G needle, self-adjusting file (SAF), passive ultrasonic irrigation, or the EndoVac system (SybronEndo, Orange, CA) during the instrumentation and final irrigation of root canals. METHODS: Matched paired single-canal teeth were divided into 8 groups. The experimental groups were needle irrigation size #30 (NI30) and #50 (NI50), SAF size #30 (SAF30) and #50 (SAF50), passive ultrasonic irrigation size #30 (PUI30) and #50 (PUI50), and EndoVac size #30 (EV30) and #50 (EV50). Teeth were embedded in 0.2% agarose gel (pH = 7.4) containing 1 mL 0.1% m-Cresol purple (Sigma-Aldrich, St Louis, MO), which changes color at a pH level of 9.0. Root canals were irrigated with sodium hypochlorite and EDTA using 4 different techniques, and the amount of irrigant was controlled. Standardized digital photographs were taken 20 minutes after the first irrigant was used and were analyzed to determine the amount of extrusion (expressed as a percentage of total pixels). RESULTS: The amounts of apical extrusion obtained in the NI30, NI50, SAF30, SAF50, PUI30, PUI50, EV30, and EV50 groups were 30% (3/10), 50% (5/10), 20% (2/10), 70% (7/10), 40% (4/10), 40% (4/10), 10% (1/10), and 10% (1/10), respectively. The overall extrusion frequency, regardless of the apical preparation size, was 40% (8/20) for needle, 45% (9/20) for SAF, 40% (8/20) for ultrasonic irrigation, and 10% (2/20) for EndoVac. Although the SAF group showed more extrusion, the percentage of pixels was significantly higher in the needle irrigation group (P < .01). The EndoVac group showed significantly lower extrusion values than the other techniques in terms of the number of teeth and pixels (P < .05 and P < .01, respectively). CONCLUSIONS: The risk of apical extrusion is significantly lower with the EndoVac in comparison with the 3 other techniques.


Assuntos
Tecido Periapical/efeitos dos fármacos , Irrigantes do Canal Radicular/farmacologia , Preparo de Canal Radicular/métodos , Hipoclorito de Sódio/farmacologia , Humanos
9.
Case Rep Dent ; 2014: 918461, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24523971

RESUMO

Radiotherapy in NPC patients has side effects on the dentition, which affects quality of life dramatically. This case report presents multidisciplinary dental treatment approach in a 17-year-old male patient with a history of nasopharyngeal carcinoma (NPC), which was treated with chemotherapy and radiotherapy. The adolescent patient applied to dental hospital 4 years after the radiotherapy with aesthetic and functional problems on dentition affecting psychological, social, and physical aspects of his life. The dentition of the patient demonstrated the severe destruction as a devastating side effect of radiotherapy. With a successful multidisciplinary approach, our patient's aesthetics, function, and self-confidence were obtained. Well-established procedures, which include preventative care and maintenance, can reduce the duration and expenses of the treatment and help in challenging the life-long complications of radiotherapy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA