1.
BMC Ophthalmol ; 23(1): 517, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38124047

RESUMO

BACKGROUND: To characterize anterior corneal higher-order aberration (HOA) excimer ablation map patterns in postoperative LASIK ectasia (POE) and to examine correlations between newly identified corneal HOA ablation map features of POE and known topographic indices. METHODS: Prospective multicenter non-interventional descriptive study. A total of 28 eyes from 22 POE patients were enrolled. The postoperative HOA ablation map was derived from Topolyzer Vario corneal imaging at the time of POE diagnosis. Features that recurred were identified and then analyzed. Correlations to Orbscan indices were studied. RESULTS: An arrangement of two elliptical paracentral ablation islands, deep inferior and shallow superior, in direct mirror-like opposition to each other, were identified on all HOA maps. The paracentral islands were accompanied by peripheral ablation crescents. The deep paracentral inferior island 'hot spot' coincided with the topographical apical POE cone and was highly reproducible in angular position (249.3 ± 17.3°). There was significant variation in ablation depth (shallow superior island: 11.5 ± 6.9 µm and deep inferior island: 32.5 ± 18.8 µm). The superior crescents had high variability in depth (34.8 ± 18.9 µm). Strong correlations were found between the corneal irregularity index and the ablation depth difference between the deep and shallow paracentral islands (R = 0.96; P < 0.0001). CONCLUSION: The corneal HOA excimer ablation map revealed a recurring, distinct, easily recognizable pattern in POE eyes. Validated Orbscan POE indices and HOA ablation map islands showed a strong correlation. It is possible to extract useful information from the corneal HOA ablation map, potentially making it suitable for diagnosing and monitoring POE although more studies are needed.


Assuntos
Aberrações de Frente de Onda da Córnea , Ceratomileuse Assistida por Excimer Laser In Situ , Miopia , Humanos , Ceratomileuse Assistida por Excimer Laser In Situ/efeitos adversos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Refração Ocular , Acuidade Visual , Topografia da Córnea , Dilatação Patológica , Estudos Prospectivos , Aberrações de Frente de Onda da Córnea/diagnóstico , Miopia/cirurgia , Lasers de Excimer/uso terapêutico , Córnea/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA