Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cancer Diagn Progn ; 2(4): 471-481, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35813008

RESUMO

AIM: The aim of this study was to clarify the usefulness of the Liver Imaging Reporting and Data System (LI-RADS) for predicting a patient's prognosis after transcatheter arterial chemoembolization (TACE) combined with radiofrequency ablation (TACE-RFA) for hepatocellular carcinoma (HCC) of Barcelona-Clinic Liver Cancer (BCLC) stage 0 or A. PATIENTS AND METHODS: We retrospectively analyzed cases of patients with HCC who underwent TACE-RFA (Jan 2005 to Dec 2015). Nodules were categorized based on their LI-RADS v2018 core. The LI-RADS category was assigned to each nodule using dynamic contrast-enhanced computed tomography. LR-3, LR-4 and LR-5 nodules were extracted. The overall (OS) and recurrence-free (RFS) survival was assessed among patients with BCLC 0 and BCLC A disease. RESULTS: Of the 64 nodules extracted, 22 were LR-3 or -4 (mean±standard deviation=14.8±6.7 mm) and 42 were LR-5 (17.1±6.9 mm). Regarding OS, there was no significant difference between those with LR-3 or -4 and LR-5 (p=0.278). In terms of RFS, there was a significant difference between those with LR-3 or -4 and those with LR-5 (p=0.03). In particular, patients with BCLC A with LR-5 nodules had significantly poorer RFS than those with LR-3 or -4 (p=0.016) nodules. CONCLUSION: For patients with BCLC A, LR-3 or -4 nodules are associated with a better prognosis than LR-5 nodules.

2.
J Chromatogr A ; 1025(2): 287-96, 2004 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-14763813

RESUMO

Analyses of amino acids and peptides were performed using a quartz microchip and an interface for microchip electrophoresis-electrospray ionization mass spectrometry (MCE-ESI-MS). In MCE-ESI-MS, negative pressure caused by ESI increased band broadening and deteriorated separation. We tried to suppress the negative pressure and improve separation using a microchip with a long separation channel. Separations of peptide standards were compared using two microchips with long separation channel (58.9 mm) and short one (22.9 mm). Theoretical plate numbers and resolution were improved significantly using the former. The theoretical plate numbers of [Val4]angiotensin was 8600 using the former and 1700 using the latter. When background electrolytes of low pH were used in an uncoated quartz microchip, electrokinetic injection was difficult because of weak electroosmotic flow. The use of successive multiple ionic polymer layers coating of the microchip channel stabilized electrokinetic injection and permitted analysis of amino acids and peptides even under low pH conditions. Separation of amino acids was successfully performed using formic acid solution (pH 2.5) as background electrolyte.


Assuntos
Eletroforese/métodos , Miniaturização , Espectrometria de Massas por Ionização por Electrospray/métodos , Concentração de Íons de Hidrogênio
3.
J Chromatogr A ; 1011(1-2): 181-92, 2003 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-14518775

RESUMO

A robust and simple interface for microchip electrophoresis-mass spectrometry (MCE-MS) was developed using a spray nozzle connected to the exit of the separation channel of the microchip. The spray nozzle was attached to the microchip using a polyether ether ketone screw without adhesive, thus allowing easy replaced. Sample injection and electrophoretic separation was performed by control of the voltage only. The analysis of a few basic drugs was performed using the optimized MCE-MS system. The separation was improved by using a high-viscosity separation buffer and a spray nozzle with a small bore size. This system was also applied to the separation of peptides and protein-trypsin digests. Sample adsorption was minimized by adding acetonitrile to the separation buffer when using a quartz microchip.


Assuntos
Espectrometria de Massas/métodos , Semicondutores , Preparações Farmacêuticas/análise , Rodaminas/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...