RESUMO

The trend towards realistic numerical models of (pathologic) patient-specific vascular structures brings along larger computational domains and more complex geometries, increasing both the computation time and the operator time. Hexahedral grids effectively lower the computational run time and the required computational infrastructure, but at high cost in terms of operator time and minimal cell quality, especially when the computational analyses are targeting complex geometries such as aneurysm necks, severe stenoses and bifurcations. Moreover, such grids generally do not allow local refinements. As an attempt to overcome these limitations, a novel approach to hexahedral meshing is proposed in this paper, which combines the automated generation of multi-block structures with a grid-based method. The robustness of the novel approach is tested on common complex geometries, such as tree-like structures (including trifurcations), stenoses, and aneurysms. Additionally, the performance of the generated grid is assessed using two numerical examples. In the first example, a grid sensitivity analysis is performed for blood flow simulated in an abdominal mouse aorta and compared to tetrahedral grids with a prismatic boundary layer. In the second example, the fluid-structure interaction in a model of an aorta with aortic coarctation is simulated and the effect of local grid refinement is analyzed.


Assuntos
Aorta Abdominal/ultraestrutura , Modelos Cardiovasculares , Animais , Aorta Abdominal/metabolismo , Hemodinâmica , Camundongos
2.
Ann Biomed Eng ; 43(6): 1370-84, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25186435

RESUMO

The aim of this study was to reconcile some of our own previous work and the work of others to generate a physiologically realistic numerical simulation environment that allows to virtually assess the performance of BMHVs. The model incorporates: (i) a left ventricular deformable model to generate a physiological inflow to the aortic valve; (ii) a patient-specific aortic geometry (root, arch and descending aorta); (iii) physiological pressure and flow boundary conditions. We particularly studied the influence of downstream geometry, valve size and orientation on leaflet kinematics and functional indices used in clinical routine. Compared to the straight tube geometry, the patient-specific aorta leads to a significant asynchronous movement of the valve, especially during the closing of the valve. The anterior leaflet starts to close first, impacts the casing at the closed position and remains in this position. At the same time, the posterior leaflet impacts the pivoting mechanisms at the fully open position. At the end of systole, this leaflet subsequently accelerates to the closed position, impacting the casing with an angular velocity of approximately -477 rad/s. The valve size greatly influences the transvalvular pressure gradient (TPG), but does not change the overall leaflet kinematics. This is in contrast to changes in valve orientation, where changing valve orientation induces large differences in leaflet kinematics, but the TPG remains approximately the same.


Assuntos
Aorta , Valva Aórtica , Pressão Arterial , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Sístole , Adulto , Aorta/patologia , Aorta/fisiopatologia , Valva Aórtica/patologia , Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Humanos , Masculino , Tamanho do Órgão