1.
J Clin Lab Anal ; 31(1)2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27364416

RESUMO

BACKGROUND: The goal of this work was to determine whether there are clinically significant fluctuations in the level of serum creatinine on serial determinations, especially in the borderline range (1.1-1.3 mg/dl), after specimen storage. METHODS: Sixty-one serum samples were analyzed. They were divided into three categories based on the initial serum creatinine measurement: low (≤1.0 mg/dl), borderline (1.1-1.3 mg/dl), and high (≥1.4 mg/dl). The specimens were stored at 4°C and run on the Siemens Advia 1800 chemistry analyzer on days 1, 3, and 11. RESULTS: Statistical comparisons of the three groups were made using the unpaired t-test, yielding a two-tailed P-value for each group comparison. The P-values ranged from 0.0829 to 0.3892, indicating no statistically significant difference between the standard deviations of each group. CONCLUSIONS: Mild-to-moderate fluctuations in precision occur in successive serum creatinine determinations. The overwhelming majority of these fluctuations should not affect clinical decision making.


Assuntos
Química Clínica/instrumentação , Creatinina/sangue , Humanos , Valores de Referência
2.
J Clin Lab Anal ; 30(3): 244-7, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-25867784

RESUMO

GOALS: The goal of this work was to determine if immediate versus postponed centrifugation of samples affects the levels of serum potassium. METHODS: Twenty participants donated normal venous blood that was collected in four serum separator tubes per donor, each of which was analyzed at 0, 1, 2, or 4 hr on the Siemens Advia 1800 autoanalyzer. RESULTS: Coefficients of variation (CVs) for potassium levels ranged from 0% to 7.6% with a mean of 3 ± 2%. ANOVA testing of the means for all 20 samples showed a P-value of 0.72 (>0.05) indicating that there was no statistically significant difference between the means of the samples at the four time points. Sixteen samples were found to have CVs that were ≤5%. Two samples showed increases of potassium from the reference range to levels higher than the upper reference limit, one of which had a 4-hr value that was within the reference or normal range (3.5-5 mEq/l). Overall, most samples were found to have reproducible levels of serum potassium. CONCLUSIONS: Serum potassium levels from stored whole blood collected in serum separator tubes are, for the most part, stable at room temperature for at least 4 hr prior to analysis. However, some samples can exhibit significant fluctuations of values.


Assuntos
Centrifugação/métodos , Potássio/sangue , Preservação Biológica , Humanos , Reprodutibilidade dos Testes , Fatores de Tempo