Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Appl Oral Sci ; 26: e20160652, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29412366

RESUMO

The relationship between wear resistance and filler size or filler loading was clarified for the universal resin composite; however, their relationship in flowable resin composites has not been clarified. The purpose of this study was to investigate the effect of filler size and filler loading on wear of experimental flowable resin composites by using a cyclic loading device. Nine experimental flowable resin composites consisting of three different sizes (70, 200 and 400 nm) and loading (50, 55 and 60 wt%) of filler were prepared. Bowl-shaped cavities were prepared on a flat surface of ceramic blocks using a No. 149 regular cut diamond point. The cavities were treated with a silane coupling agent and an all-in-one adhesive and then filled with each experimental flowable resin composite. The restored surfaces were finished and polished with a 1500-grit silicon carbide paper. The specimens were subjected to an in vitro two-body wear test using a cyclic loading device. The localized worn surfaces were evaluated at 10,000, 20,000, 30,000, and 40,000 cycles using a computer-controlled three-dimensional measuring microscope (n=5). The volumetric wear loss of the materials was calculated automatically by the equipment. Data were statistically analyzed with two-way ANOVA and post hoc Tukey test. Two-way ANOVA showed that the filler size significantly influenced wear volume (p<0.003), but the filler loading did not have a significant effect (p>0.05). A post hoc Tukey test detected significant differences in filler size between 70 nm and 400 nm, and 200 nm and 400 nm (p<0.007). The experimental flowable resin composite containing a mean filler size of 400 nm exhibited significantly lower wear resistance in two-body wear compared with those containing mean filler sizes of 200 nm or 70 nm.


Assuntos
Resinas Compostas/química , Desgaste de Restauração Dentária , Metacrilatos/química , Cimentos de Resina/química , Análise de Variância , Teste de Materiais , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Valores de Referência , Reprodutibilidade dos Testes , Propriedades de Superfície , Fatores de Tempo
2.
J. appl. oral sci ; 26: e20160652, 2018. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-893729

RESUMO

Abstract The relationship between wear resistance and filler size or filler loading was clarified for the universal resin composite; however, their relationship in flowable resin composites has not been clarified. Objectives: The purpose of this study was to investigate the effect of filler size and filler loading on wear of experimental flowable resin composites by using a cyclic loading device. Material and Methods: Nine experimental flowable resin composites consisting of three different sizes (70, 200 and 400 nm) and loading (50, 55 and 60 wt%) of filler were prepared. Bowl-shaped cavities were prepared on a flat surface of ceramic blocks using a No. 149 regular cut diamond point. The cavities were treated with a silane coupling agent and an all-in-one adhesive and then filled with each experimental flowable resin composite. The restored surfaces were finished and polished with a 1500-grit silicon carbide paper. The specimens were subjected to an in vitro two-body wear test using a cyclic loading device. The localized worn surfaces were evaluated at 10,000, 20,000, 30,000, and 40,000 cycles using a computer-controlled three-dimensional measuring microscope (n=5). The volumetric wear loss of the materials was calculated automatically by the equipment. Data were statistically analyzed with two-way ANOVA and post hoc Tukey test. Results: Two-way ANOVA showed that the filler size significantly influenced wear volume (p<0.003), but the filler loading did not have a significant effect (p>0.05). A post hoc Tukey test detected significant differences in filler size between 70 nm and 400 nm, and 200 nm and 400 nm (p<0.007). Conclusion: The experimental flowable resin composite containing a mean filler size of 400 nm exhibited significantly lower wear resistance in two-body wear compared with those containing mean filler sizes of 200 nm or 70 nm.


Assuntos
Resinas Compostas/química , Cimentos de Resina/química , Desgaste de Restauração Dentária , Metacrilatos/química , Tamanho da Partícula , Valores de Referência , Propriedades de Superfície , Fatores de Tempo , Teste de Materiais , Microscopia Eletrônica de Varredura , Reprodutibilidade dos Testes , Análise de Variância
3.
Dent Mater J ; 36(3): 348-356, 2017 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-28190811

RESUMO

The aim of this study was to histologically evaluate direct pulp capping using different all-in-one adhesives in rat teeth. Five all-in-one adhesives and a control material (MTA) were used. Each material was applied on the exposed pulp, and each cavity was subsequently restored with the resin composite. Rats were sacrificed 14 days after the surgical procedure. Serial stained sections were histologically evaluated for examining pulp tissue disorganization (PTD), inflammatory cell infiltration (ICI), dentin bridge formation (DBF), and bacterial penetration (BP). We found that rat pulps, which were direct capped with all-in-one adhesives, showed various degrees of PTD, ICI, and DBF depending on the material, and that there were no complete dentin bridges. In contrast, rat pulps capped with MTA showed no PTD and ICI, and there were complete dentin bridges in all, but one specimen. No BP was observed in any specimen.


Assuntos
Adesivos , Capeamento da Polpa Dentária , Animais , Hidróxido de Cálcio , Polpa Dentária , Exposição da Polpa Dentária , Dentina Secundária , Ratos , Cimentos de Resina
4.
Dent Mater J ; 35(1): 37-44, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26843441

RESUMO

The purpose of this study was to examine three- and two-body wear values of flowable resin composites for posterior restorations, using a mechanical loading device. The cavities prepared on flattened extracted molars were restored with flowable resin composites (Clearfil Majesty LV: MLV, Estelite Flow Quick: EFQ, Beautifil Flow Plus F00: BFP, and MI Fill: MIF) using accompanying adhesive systems. A universal resin composite (Clearfil Majesty) was used as a control. The specimens were subjected to in vitro three- and two-body wear testing. MLV showed high wear value (three-body: 14.69 µm, two-body: 0.268 mm(3)) compared with other materials tested in both three- and two-body wear tests. BFP showed high three-body wear value (5.78 µm), whereas low two-body wear value (0.008 mm(3)). MIF and EFQ showed equivalent wear values (MIF, three-body: 0.42 µm, two-body: 0.026 mm(3); EFQ, three-body: 1.15 µm, two-body: 0.14 mm(3)) to that of the control in both wear tests.


Assuntos
Resinas Compostas/química , Restauração Dentária Permanente , Falha de Restauração Dentária , Análise do Estresse Dentário , Cimentos de Ionômeros de Vidro/química , Dureza , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
5.
J Dent ; 44: 27-36, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26620099

RESUMO

OBJECTIVES: This study examines the wound healing process in exposed rat pulp when capped with experimental adhesive resin systems. METHODS: Experimental adhesive resin system for direct pulp capping was composed of primer-I (PI), -II (PII), and -III (PIII) and an experimental bonding agent (EBA). PI was Clearfil(®) SE Bond(®)/Primer (CSP) containing 5.0 wt% CaCl2, PII was PI containing 10 wt% nanofiller (Aerosil(®) 380), and PIII was CSP containing 5.0 wt% of compounds of equal moles of synthetic peptides (pA and pB) derived from dentin matrix protein 1. EBA was Clearfil(®) SE Bond(®)/Bond (CSB) containing 10 wt% hydroxyapatite powders. Three experimental groups were designed. PI was assigned to experimental Groups 1 and 3. PII was assigned to experimental Groups 2 and 3. PIII and EBA were assigned to all experimental adhesive groups. Control teeth were capped with calcium hydroxide preparation (Dycal(®)), and CSP and CSB were applied to the cavity. The rats were sacrificed after each observation period (14, 28, 56, and 112 days). The following parameters were evaluated: pulp tissue disorganization, inflammatory cell infiltration, reparative dentin formation (RDF), and bacterial penetration. RESULTS: There were no significant differences among all the groups for all parameters and all observation periods (p>0.05, Kruskal-Wallis test). All groups showed initial RDF at 14 days postoperatively and extensive RDF until 112 days postoperatively. Groups 2 and 3 demonstrated higher quantity of mineralized dentin bridge formation compared with Group 1. CONCLUSIONS: Addition of nanofillers to the primer was effective in promoting high-density RDF. CLINICAL SIGNIFICANCE: Experimentally developed adhesive resin systems induce the exposed pulp to produce almost the same quantity of reparative dentin as calcium hydroxide. However, we need further studies to elucidate whether the same results could be obtained in humans.


Assuntos
Capeamento da Polpa Dentária/métodos , Polpa Dentária/patologia , Adesivos Dentinários/farmacologia , Tratamento do Canal Radicular/métodos , Adesivos/química , Adesivos/farmacologia , Animais , Cloreto de Cálcio , Polpa Dentária/efeitos dos fármacos , Polpa Dentária/microbiologia , Exposição da Polpa Dentária/terapia , Restauração Dentária Permanente , Dentina Secundária/efeitos dos fármacos , Dentina Secundária/patologia , Adesivos Dentinários/química , Masculino , Agentes de Capeamento da Polpa Dentária e Pulpectomia/química , Agentes de Capeamento da Polpa Dentária e Pulpectomia/farmacologia , Pulpite/patologia , Ratos , Ratos Sprague-Dawley , Cimentos de Resina/química , Cimentos de Resina/farmacologia
6.
Odontology ; 100(2): 164-71, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21604190

RESUMO

The purpose of this study was to examine, morphologically and histochemically, five types of conditioning effects on cavities prepared with an Er,Cr:YSGG laser and an air-turbine. Cavities were prepared using a Waterlase(®) MD turbo handpiece (W) and an air-turbine (AT) on human extracted molars. The cavity conditionings used were non-conditioned (G1), K-etchant Gel (G2), K-etchant Gel + AD Gel (G3), Clearfil SE Bond primer (G4) and Clearfil S(3) Bond (G5). On naked eye observations, enamel of G1, G2 and G3 in the W cavities and etched enamel of G2 and G3 in the AT cavities were observed as rough and dull in appearance. G4 and G5 in W and AT cavities were observed as shiny surfaces. On SEM observations, no smeared layer was observed in W cavities, while a smeared layer and bur-scratches were observed in AT cavities. In W cavities, rough surfaces were observed on enamel. That is, cracks and minute rough surfaces were observed. In contrast, equally etched scale-shaped enamel rods were observed in AT cavities. Widely opened dentinal tubules and protruding peritubular matrices of dentin were observed in W cavities. A few remaining smeared plugs could be observed at the AT cavities. On LM observations, 13-16 µm layers of the dentin in G1, G2, G4 and G5 of W cavities were stained red in color by the Azan staining method, while redness was not observed in G3. No groups were stained red in AT cavities. It was considered that layers stained red in color were thermal degeneration layers of dentin induced by W. Namely 30 s etching of 40% phosphoric acid gel followed by 90 s treatment of 10% NaClO gel should be recommended for use when combined with an Er,Cr:YSGG laser for cavity preparation.


Assuntos
Preparo da Cavidade Dentária/métodos , Equipamentos Odontológicos de Alta Rotação , Lasers de Estado Sólido/uso terapêutico , Condicionamento Ácido do Dente/métodos , Corantes , Preparo da Cavidade Dentária/instrumentação , Esmalte Dentário/efeitos da radiação , Esmalte Dentário/ultraestrutura , Dentina/efeitos da radiação , Dentina/ultraestrutura , Adesivos Dentinários/química , Humanos , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos/química , Cimentos de Resina/química , Camada de Esfregaço , Hipoclorito de Sódio/química , Fatores de Tempo
7.
Odontology ; 99(2): 135-47, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21516293

RESUMO

This study examined the wound-healing process of exposed rat pulp when treated with experimental adhesive resin systems. The experimental direct pulp capping adhesive resin systems were composed of primer-I, primer-II and an experimental bonding agent. Primer-I was Clearfil SE Bond (CSE) primer containing 1.0 or 5.0 wt% CaCl(2), and primer-II was CSE primer containing 0.1, 1.0 or 5.0 wt% compound of equal mole of pA and pB with synthetic peptides derived from dentin matrix protein 1 (DMP1). Primer-I containing 1.0 and 5.0 wt% CaCl(2) was assigned to the experimental groups 1-3 and 4-6, respectively. Primer-II containing 0.1, 1.0 or 5.0 wt% compound of pA and pB was assigned to the experimental groups 1 and 4, 2 and 5, and 3 and 6, respectively. In all experimental groups, CSE bond containing 10 wt% hydroxyapatite powder was used as the experimental bonding agent. The positive control teeth were capped with calcium hydroxide preparation (Dycal), and the negative control teeth were capped with CSE. The specimens were alternately stained with Mayer's H&E and the enhanced polymer one-step staining methods. Experimental groups 1, 4, 5 and 6 showed a higher level of reparative dentin formation compared to the negative control 14 days postoperatively. At 28 days postoperatively, all experimental groups showed the formation of extensive reparative dentin, and experimental groups 4, 5 and 6 demonstrated similar dentin bridge formation as that of the positive control. How quickly reparative dentin formation occurs may depend on the concentration of CaCl(2) and the compound of pA and pB in the experimental primer.


Assuntos
Capeamento da Polpa Dentária/métodos , Polpa Dentária/efeitos dos fármacos , Dentina Secundária/efeitos dos fármacos , Proteínas da Matriz Extracelular/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Fosfoproteínas/uso terapêutico , Agentes de Capeamento da Polpa Dentária e Pulpectomia/uso terapêutico , Cimentos de Resina/química , Animais , Cloreto de Cálcio/uso terapêutico , Hidróxido de Cálcio/uso terapêutico , Colagem Dentária , Polpa Dentária/patologia , Exposição da Polpa Dentária/terapia , Necrose da Polpa Dentária/patologia , Restauração Dentária Permanente , Dentina Secundária/patologia , Durapatita/uso terapêutico , Masculino , Metacrilatos/química , Minerais/uso terapêutico , Odontoblastos/patologia , Processos Fotoquímicos , Polimerização , Pulpite/patologia , Ratos , Ratos Sprague-Dawley , Fatores de Tempo , Cicatrização/efeitos dos fármacos
8.
Dent Mater J ; 29(6): 738-46, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21099165

RESUMO

The purpose of this study was to evaluate the microtensile bond strength (MTBS) of an experimental adhesive system, which was prepared using different concentrations of calcium chloride (CaCl(2)) and synthetic peptides (pA/pB). Specimens were divided into six experimental groups and two control groups. In the experimental groups, self-etching primers used in the adhesive system comprised both Primer-I (Clearfil SE Bond Primer (SEP) containing 1, 5, or 10 wt% CaCl(2)) and Primer-II (SEP containing 0.1, 1, 5, or 10 wt% pA/pB). The negative control group used Primer-I containing 10 wt% CaCl(2 )and Primer-II containing 10 wt% pA/pB. The positive control group used Clearfil SE Bond only. Respective primers, bonding resin, and composite paste were applied and photopolymerized individually on flattened dentin surfaces of extracted human molars. All specimens were subjected to MTBS testing (n=20). Two-way ANOVA revealed significant differences in MTBS among CaCl(2 )concentrations in Primer-I and pA/pB concentrations in Primer-II (p<0.001), and there was a significant interaction between these two factors (p=0.011).


Assuntos
Cloreto de Cálcio/química , Colagem Dentária , Dentina/ultraestrutura , Proteínas da Matriz Extracelular/química , Fosfoproteínas/química , Adesividade , Resinas Compostas/química , Desinfetantes de Equipamento Odontológico/química , Durapatita/química , Humanos , Peróxido de Hidrogênio/química , Teste de Materiais , Metacrilatos/química , Polimerização , Cimentos de Resina/química , Hipoclorito de Sódio/química , Estresse Mecânico , Propriedades de Superfície
9.
Odontology ; 98(2): 110-6, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20652788

RESUMO

The purpose of this study was to evaluate the microtensile bond strength (microTBS) of an experimental adhesive system containing calcium chloride (CaCl(2)), synthetic peptides derived from dentin matrix protein 1 (DMP1: pA and pB), and hydroxyapatite experimentally developed for direct pulp capping to human dentin. Clearfil SE Bond/Primer (SEP) and Bond (SEB) were used for each experimental group as the matrix agents. Experimental self-etching primers included: primer-I, SEP containing 10 wt% CaCl(2), and primer-II, SEP containing a 10 wt% compound of pA and pB. The experimental bonding agent was a mixture of SEB and 10 wt% hydroxyapatite. Specimens were divided into five experimental groups, including the control, according to the mode of primer application. Primer-I was primarily applied, followed by primer-II for group 1, primer-I as the primary and SEP as the secondary for group 2, SEP as the primary and primer-II as the secondary for group 3, and SEP was applied twice for group 4, and SEP was applied once for the control. Clearfil SE Bond adhesive system was used as the control. Flat dentin surfaces of human molars were assigned to bonding tests. After each experimental primer was applied to the dentin surface, each experimental bonding agent was applied and photopolymerized, and then resin composite paste (Clearfil Flow FX and Clearfil AP-X) was placed and photopolymerized. The specimens were subjected to microTBS testing. The data were compared using analysis of variance (ANOVA) and post-hoc Bonferroni/Dunn tests. Results showed that the minimum mean value of microTBS was 15.4 MPa for group 1, while the maximum mean value of microTBS was 52.7 MPa for the control. There were significant differences among the experimental groups, except for group 4 and the control. The experimental primers containing CaCl(2) or DMP1 negatively affected the microTBS value of the experimental adhesive system to dentin.


Assuntos
Cloreto de Cálcio/química , Colagem Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Durapatita/química , Proteínas da Matriz Extracelular/química , Fosfoproteínas/química , Resinas Compostas/química , Capeamento da Polpa Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Processos Fotoquímicos , Polímeros/química , Ácidos Polimetacrílicos/química , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
10.
Dent Mater J ; 28(6): 743-9, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20019427

RESUMO

The purpose of this study was to evaluate the microtensile bond strength (microTBS) to human dentin of an experimental bonding agent containing calcium phosphates experimentally developed for direct pulp capping. Different concentrations of four types of calcium phosphates were added to an experimental bonding monomer, and six experimental bonding agents were thus prepared. Clearfil SE Bond/Bond was used as the control. Flat dentin surfaces of human molars were assigned to the experimental adhesive systems and the control. After Clearfil SE Bond/Primer was applied to the dentin surface, each experimental bonding agent was applied and photopolymerized, and then a resin composite paste was placed and photopolymerized. The specimens were subjected to microTBS testing. Results revealed that there were no significant differences among the microTBS values of the experimental bonding agents and the control. In other words, the calcium phosphate-containing experimental adhesives did not adversely affect the microTBS to dentin.


Assuntos
Fosfatos de Cálcio/química , Colagem Dentária , Capeamento da Polpa Dentária , Adesivos Dentinários/química , Dentina/ultraestrutura , Adesividade , Resinas Compostas/química , Durapatita/química , Humanos , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Ácidos Polimetacrílicos/química , Cimentos de Resina/química , Estresse Mecânico , Propriedades de Superfície , Resistência à Tração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...