Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 633
Filtrar
1.
Clin Radiol ; 79(6): 453-459, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38614869

RESUMO

AIM: To evaluate whether deep learning reconstruction (DLR) can accelerate the acquisition of magnetic resonance imaging (MRI) sequences of the knee for clinical use. MATERIALS AND METHODS: Using a 1.5-T MRI scanner, sagittal fat-suppressed T2-weighted imaging (fs-T2WI), coronal proton density-weighted imaging (PDWI), and coronal T1-weighted imaging (T1WI) were performed. DLR was applied to images with a number of signal averages (NSA) of 1 to obtain 1DLR images. Then 1NSA, 1DLR, and 4NSA images were compared subjectively, and by noise (standard deviation of intra-articular water or medial meniscus) and contrast-to-noise ratio between two anatomical structures or between an anatomical structure and intra-articular water. RESULTS: Twenty-seven healthy volunteers (age: 40.6 ± 11.9 years) were enrolled. Three 1DLR image sequences were obtained within 200 s (approximately 12 minutes for 4NSA image). According to objective evaluations, PDWI 1DLR images showed the smallest noise and significantly higher contrast than 1NSA and 4NSA images. For fs-T2WI, smaller noise and higher contrast were observed in the order of 4NSA, 1DLR, and 1NSA images. According to the subjective analysis, structure visibility, image noise, and overall image quality were significantly better for PDWI 1DLR than 1NSA images; moreover, the visibility of the meniscus and bone, image noise, and overall image quality were significantly better for 1DLR than 4NSA images. Fs-T2WI and T1WI 1DLR images showed no difference between 1DLR and 4NSA images. CONCLUSION: Compared to PDWI 4NSA images, PDWI 1DLR images were of higher quality, while the quality of fs-T2WI and T1WI 1DLR images was similar to that of 4NSA images.


Assuntos
Aprendizado Profundo , Articulação do Joelho , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Adulto , Feminino , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/anatomia & histologia , Voluntários Saudáveis , Pessoa de Meia-Idade , Razão Sinal-Ruído , Interpretação de Imagem Assistida por Computador/métodos
2.
Nat Commun ; 14(1): 955, 2023 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-36804939

RESUMO

Proton-boron (p11B) fusion is an attractive potential energy source but technically challenging to implement. Developing techniques to realize its potential requires first developing the experimental capability to produce p11B fusion in the magnetically-confined, thermonuclear plasma environment. Here we report clear experimental measurements supported by simulation of p11B fusion with high-energy neutral beams and boron powder injection in a high-temperature fusion plasma (the Large Helical Device) that have resulted in diagnostically significant levels of alpha particle emission. The injection of boron powder into the plasma edge results in boron accumulation in the core. Three 2 MW, 160 kV hydrogen neutral beam injectors create a large population of well-confined, high -energy protons to react with the boron plasma. The fusion products, MeV alpha particles, are measured with a custom designed particle detector which gives a fusion rate in very good relative agreement with calculations of the global rate. This is the first such realization of p11B fusion in a magnetically confined plasma.

3.
Clin Radiol ; 78(1): e13-e21, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36116967

RESUMO

AIM: To evaluate 1.5 T magnetic resonance imaging (MRI) brain images with denoising procedures using deep learning-based reconstruction (dDLR) relative to the original 1.5 and 3 T images. MATERIALS AND METHODS: Eleven volunteers underwent MRI at 3 and 1.5 T. Two-dimensional fast spin-echo T2-weighted imaging (T2WI), fluid-attenuated inversion recovery (FLAIR) imaging and diffusion-weighted imaging (DWI) sequences were performed. The dDLR method was applied to the 1.5 T data (dDLR-1.5 T), then the image quality of the dDLR-1.5 T data relative to the original 1.5 T and 3 T data was qualitatively and quantitatively assessed based on the structure similarity (SSIM) index; the signal-to-noise ratios (SNRs) of the grey matter (GM) and white matter (WM); and the contrast-to-noise ratios (CNRs) between the GM and WM (CNRgm-wm) and between the striatum (ST) and WM (CNRst-wm). RESULTS: The perceived image quality, and SNRs and CNRs were significantly higher for the dDLR-1.5 T images versus the 1.5 T images for all sequences and almost comparable or even superior to those of the 3 T images. For DWI, the SNRs and CNRst-wm were significantly higher for the dDLR-1.5 T images versus the 3 T images. CONCLUSION: The dDLR technique improved the image quality of 1.5 T brain MRI images. With respect to qualitative and quantitative measurements, the denoised 1.5 T brain images were almost equivalent or even superior to the 3 T brain images.


Assuntos
Neoplasias Encefálicas , Aprendizado Profundo , Humanos , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Encefálicas/patologia
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1258-1261, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086560

RESUMO

We fabricated a wearable sensor that can be attached to the skin surface and continuously measure core body temperature (CBT) wirelessly over a long period. CBT is calculated from skin-surface temperature and heat flux passing through the sensor. Since heat flux is lost to the surroundings of the probe, the slightest change in convection in daily life will degrade the measurement accuracy of the sensor. Accordingly, we previously proposed a heat-flux-path control structure to reduce the absolute amount of heat-flux loss. To make wearable sensors for long-term human trials, we proposed an integrated design in which a sensor probe, a circuit board, and a battery are stacked. We optimized the proposed design by computer simulation and evaluated the fabricated sensor by a phantom experiment in which the convectional state was changed. The evaluation results demonstrate that the sensor has limits of agreement (LOA) of [-0.13; 0.03]°C under 1-m/s-wind convection. Moreover, a preliminary human trial conducted under daily-life conditions (including convectional changes) demonstrated that the sensor has LOA of [-0.18; 0.22]°C. These results demonstrate that the fabricated sensor is suitable for CBT measurement.


Assuntos
Temperatura Corporal , Termômetros , Simulação por Computador , Humanos , Temperatura Cutânea , Temperatura
5.
Biomed Phys Eng Express ; 8(6)2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-35961284

RESUMO

Objective.The goal of this study was to use Monte Carlo (MC) simulations and measurements to investigate the dosimetric suitability of an interventional radiology (IR) c-arm fluoroscope to deliver low-dose radiotherapy to the lungs.Approach.A previously-validated MC model of an IR fluoroscope was used to calculate the dose distributions in a COVID-19-infected patient, 20 non-infected patients of varying sizes, and a postmortem subject. Dose distributions for PA, AP/PA, 3-field and 4-field treatments irradiating 95% of the lungs to a 0.5 Gy dose were calculated. An algorithm was created to calculate skin entrance dose as a function of patient thickness for treatment planning purposes. Treatments were experimentally validated in a postmortem subject by using implanted dosimeters to capture organ doses.Main results.Mean doses to the left/right lungs for the COVID-19 CT data were 1.2/1.3 Gy, 0.8/0.9 Gy, 0.8/0.8 Gy and 0.6/0.6 Gy for the PA, AP/PA, 3-field, and 4-field configurations, respectively. Skin dose toxicity was the highest probability for the PA and lowest for the 4-field configuration. Dose to the heart slightly exceeded the ICRP tolerance; all other organ doses were below published tolerances. The AP/PA configuration provided the best fit for entrance skin dose as a function of patient thickness (R2 = 0.8). The average dose difference between simulation and measurement in the postmortem subject was 5%.Significance.An IR fluoroscope should be capable of delivering low-dose radiotherapy to the lungs with tolerable collateral dose to nearby organs.


Assuntos
COVID-19 , Planejamento da Radioterapia Assistida por Computador , COVID-19/radioterapia , Humanos , Pulmão/diagnóstico por imagem , Método de Monte Carlo , Radiologia Intervencionista , Planejamento da Radioterapia Assistida por Computador/métodos
6.
Phys Med ; 94: 24-34, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34979431

RESUMO

PURPOSE: To use MC simulations and phantom measurements to investigate the dosimetry of a kilovoltage x-ray beam from an IR fluoroscope to deliver low-dose (0.3-1.0 Gy) radiotherapy to the lungs. MATERIALS AND METHODS: PENELOPE was used to model a 125 kV, 5.94 mm Al HVL x-ray beam produced by a fluoroscope. The model was validated through depth-dose, in-plane/cross-plane profiles and absorbed dose at 2.5-, 5.1-, 10.2- and 15.2-cm depths against the measured beam in an acrylic phantom. CT images of an anthropomorphic phantom thorax/lungs were used to simulate 0.5 Gy dose distributions for PA, AP/PA, 3-field and 4-field treatments. DVHs were generated to assess the dose to the lungs and nearby organs. Gafchromic film was used to measure doses in the phantom exposed to PA and 4-field treatments, and compared to the MC simulations. RESULTS: Depth-dose and profile results were within 3.2% and 7.8% of the MC data uncertainty, respectively, while dose gamma analysis ranged from 0.7 to 1.0. Mean dose to the lungs were 1.1-, 0.8-, 0.9-, and 0.8- Gy for the PA, AP/PA, 3-field, and 4-field after isodose normalization to cover âˆ¼ 95% of each lung volume. Skin dose toxicity was highest for the PA and lowest for the 4-field, and both arrangements successfully delivered the treatment on the phantom. However, the dose distribution for the PA was highly non-uniform and produced skin doses up to 4 Gy. The dose distribution for the 4-field produced a uniform 0.6 Gy dose throughout the lungs, with a maximum dose of 0.73 Gy. The average percent difference between experimental and Monte Carlo values were -0.1% (range -3% to +4%) for the PA treatment and 0.3% (range -10.3% to +15.2%) for the 4-field treatment. CONCLUSION: A 125 kV x-ray beam from an IR fluoroscope delivered through two or more fields can deliver an effective low-dose radiotherapy treatment to the lungs. The 4-field arrangement not only provides an effective treatment, but also significant dose sparing to healthy organs, including skin, compared to the PA treatment. Use of fluoroscopy appears to be a viable alternative to megavoltage radiation therapy equipment for delivering low-dose radiotherapy to the lungs.


Assuntos
Radiologia Intervencionista , Radiometria , Fluoroscopia , Pulmão/diagnóstico por imagem , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
7.
Rev Sci Instrum ; 92(5): 053542, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243356

RESUMO

In TAE Technologies' current experimental device, C-2W, neutral beam injection creates a large fast ion population that sustains a field-reversed configuration (FRC) plasma. Diagnosis of these fast ions is therefore critical for understanding the behavior of the FRC. Neutral Particle Analyzers (NPAs) are used to measure the energy spectrum of fast ions that charge exchange on background or beam neutrals and are lost from the plasma. To ensure correct diagnosis of the fast ion population, a calibration check of the NPAs was performed. A novel, generally applicable method for an in situ relative calibration of diagnostics on an unknown source with a small dataset was developed. The method utilizes a machine learning technique, Generalized Additive Models (GAMs), to reconstruct the diagnostic source distribution, and Stochastic Gradient Descent (SGD) to determine the NPA channel calibration factors. The results on both synthetic and experimental datasets are presented.

8.
Rev Sci Instrum ; 92(3): 035003, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820008

RESUMO

Trapped magnetic flux in bulk superconductors reduces the quality factor Q in superconducting radio-frequency (SRF) cavities. However, the mechanisms underlying flux trapping and radio-frequency loss are not well understood. Detailed observation of the magnetic distributions is important for understanding such phenomena. Magnetic field mapping is useful for observing the magnetic field distribution around SRF cavities. Measuring the change in the magnetic field around the cavity elucidates the flux trapping behavior. Anisotropic magnetoresistive (AMR) sensors are inexpensive and small devices that can detect magnetic flux density. The magnetic sensitivities of AMR sensors need to be evaluated at liquid helium temperature for the magnetic field mapping of SRF cavities. In this study, a test stand was constructed to calibrate the magnetic sensitivities of AMR sensors in liquid helium, and 110 AMR sensors were tested using this stand. The magnetic sensitivities were evaluated systematically. A solenoid coil was used to control the uniform external magnetic field and to measure the magnetic sensitivity at low temperatures. All AMR sensors exhibited suitable sensitivities to the magnetic field around the SRF cavity. The variation in these sensitivities in all AMR sensors was ∼1%. The AMR sensors were found to have sufficient sensitivity for mapping the magnetic field around the exterior surface of the SRF cavity.

9.
Opt Express ; 29(6): 9123-9136, 2021 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-33820346

RESUMO

Intense few-cycle laser pulses have a breadth of applications in high energy density science, including particle acceleration and x-ray generation. Multi-amplifier laser system pulses have durations of tens of femtoseconds or longer. To achieve high intensities at the single-cycle limit, a robust and efficient post-compression scheme is required. We demonstrate a staged compression technique using self-phase modulation in thin dielectric media, in which few-cycle pulses can be produced. The few-cycle pulse is then used to generate extreme ultravoilet light via high harmonic generation at strong field intensities and to generate MeV electron beams via laser solid interactions at relativistic intensities.

10.
J Endocrinol Invest ; 43(9): 1317-1325, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32219690

RESUMO

PURPOSE: Wolfram syndrome (WS) is a rare disorder caused by mutations in WFS1 that is characterized by diabetes mellitus, optic atrophy, sensorineural deafness, diabetes insipidus, and neurodegeneration. This disease is usually inherited as an autosomal recessive trait, but an autosomal dominant form has been reported. WFS1 encodes a transmembrane protein, which is a maintenance component of endoplasmic homeostasis. These dominant mutations were thought to increase endoplasmic reticulum (ER) stress. Recent studies suggest that 4-phenylbutyrate (PBA) and valproate (VPA) reduce ER stress. The objective of this study was to analyze the effect of PBA and VPA on dominant WFS1 mutants in vitro. METHODS: We determined whether dominant WFS1 mutants (p.His313Tyr, p.Trp314Arg, p.Asp325_Ile328del, p.Glu809Lys, and p.Glu864Lys) have the dominant negative effect using a luciferase assay of ER stress response element marker as ER stress. Moreover, the rescue of cell apoptosis induced by dominant WFS1 mutants following treatment with PBA or VPA was determined by quantitative real-time PCR of C/EBP homologous protein (CHOP) mRNA expression. RESULTS: These mutants showed the dominant negative effect on the wild-type WFS1. In addition, the levels of ER stress and CHOP mRNA were significantly elevated by all dominant WFS1 mutants. After treatment with PBA or VPA, ER stress and cell apoptosis were reduced in each mutant. CONCLUSIONS: PBA and VPA could reduce the ER stress and cell apoptosis caused by dominant WFS1 mutants.


Assuntos
Proteínas de Membrana/fisiologia , Fenilbutiratos/farmacologia , Ácido Valproico/farmacologia , Síndrome de Wolfram/genética , Animais , Apoptose/efeitos dos fármacos , Apoptose/genética , Células Cultivadas , Estresse do Retículo Endoplasmático/efeitos dos fármacos , Estresse do Retículo Endoplasmático/genética , Regulação da Expressão Gênica/efeitos dos fármacos , Genes Dominantes/efeitos dos fármacos , Genes Dominantes/fisiologia , Células HEK293 , Células HeLa , Humanos , Proteínas de Membrana/genética , Proteínas de Membrana/metabolismo , Camundongos , Camundongos Transgênicos , Mutação/fisiologia , Transporte Proteico/efeitos dos fármacos , Elementos de Resposta/efeitos dos fármacos , Distribuição Tecidual/efeitos dos fármacos , Fator de Transcrição CHOP/genética , Ativação Transcricional/efeitos dos fármacos , Transfecção
11.
J Hosp Infect ; 104(3): 344-349, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31790746

RESUMO

BACKGROUND: Though nurses have frequent contact with patients, their personal protective equipment (PPE) compliance rate is low, which poses a significant challenge in infection control. AIM: To investigate the relative influence of specific factors on PPE compliance. METHODS: A sequential two-stage mixed-methods design was applied. In a qualitative study, semi-structured interviews were conducted from May to July 2018. In a quantitative study, a nationwide, cross-sectional survey was conducted from January to March 2019, in which a questionnaire was mailed to 735 nurses in 28 tertiary care hospitals in Japan. FINDINGS: In the quantitative study, 435 (59.2%) analysable responses were obtained. In the linear regression analysis, the lack of the knowledge that 'standard precaution was the fundamental infection countermeasure applied when patients had signs of infections, and these countermeasures could be terminated if there was no infection found' was significantly associated with decreased PPE adherence, whereas an antimicrobial-resistant bacteria outbreak or a ward shutdown due to an outbreak and the belief 'I must never be the cause of spreading infection' were significantly associated with increased PPE adherence. The ß of standard coefficients and t-values of the items were -0.344, -7.784, 0.090, 2.089, 0.088, 2.018, respectively. CONCLUSION: This survey systematically identified nursing-associated factors that contribute to PPE compliance. As a practical approach to ensure positive outcomes, we suggest educating nurses by providing adequate knowledge on appropriate PPE use and sharing outbreak or ward shutdown experiences.


Assuntos
Controle de Infecções/métodos , Enfermeiras e Enfermeiros , Equipamento de Proteção Individual , Adulto , Estudos Transversais , Feminino , Fidelidade a Diretrizes , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Centros de Atenção Terciária , Adulto Jovem
12.
Horm Res Paediatr ; 91(6): 357-372, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31319416

RESUMO

This update, written by authors designated by multiple pediatric endocrinology societies (see List of Participating Societies) from around the globe, concisely addresses topics related to changes in GnRHa usage in children and adolescents over the last decade. Topics related to the use of GnRHa in precocious puberty include diagnostic criteria, globally available formulations, considerations of benefit of treatment, monitoring of therapy, adverse events, and long-term outcome data. Additional sections review use in transgender individuals and other pediatric endocrine related conditions. Although there have been many significant changes in GnRHa usage, there is a definite paucity of evidence-based publications to support them. Therefore, this paper is explicitly not intended to evaluate what is recommended in terms of the best use of GnRHa, based on evidence and expert opinion, but rather to describe how these drugs are used, irrespective of any qualitative evaluation. Thus, this paper should be considered a narrative review on GnRHa utilization in precocious puberty and other clinical situations. These changes are reviewed not only to point out deficiencies in the literature but also to stimulate future studies and publications in this area.


Assuntos
Hormônio Liberador de Gonadotropina/uso terapêutico , Puberdade Precoce , Adolescente , Criança , Feminino , Humanos , Masculino , Puberdade Precoce/diagnóstico , Puberdade Precoce/tratamento farmacológico , Puberdade Precoce/patologia , Puberdade Precoce/fisiopatologia
13.
Rev Sci Instrum ; 89(10): 10H116, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399746

RESUMO

A versatile combination Doppler backscattering and Cross-Polarization Scattering (CPS) diagnostic for the C-2W beam-driven field-reversed configuration is described. This system is capable of measuring density fluctuations and perpendicular magnetic field fluctuations across a wide wavenumber range (2.5 ≤ k θ ρ s ≤ 50), with typical resolution Δk θ/k θ ≤ 0.4-0.8. Four tunable frequencies (26 GHz ≤ f ≤ 60 GHz corresponding to plasma cut-off densities 0.8 × 1019 ≤ n e ≤ 4.4 × 1019 m-3) are launched via quasi-optical beam combiners/polarizers and an adjustable parabolic focusing mirror selecting the beam incidence angle. GENRAY ray tracing shows that the incident O-mode and backscattered CPS X-mode beam trajectories for C-2W plasma parameters nearly overlap, allowing simultaneous detection of ñ and B̃ r or B̃ θ from essentially the same scattering volume.

14.
Rev Sci Instrum ; 89(10): 10J114, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399830

RESUMO

Field-reversed configuration (FRC) Amplification via Translation-Collisional Merging (FAT-CM) experiments have recently commenced to study physics phenomena of colliding and merged FRC plasma states. Two independently formed FRCs are translated into the confinement region of the FAT-CM device, collided near the mid-plane of the device with a relative speed of up to ∼400 km/s, and a final merged FRC plasma state is achieved. To measure internal magnetic field profiles of the translated and merged FRC plasmas as well as to understand its collisional-merging process, an internal magnetic probe array, developed by TAE Technologies, has been installed in the mid-plane of the FAT-CM device. Initial magnetic field measurements indicate that both the translated and the merged FRC plasma states exhibit a clear field-reversed structure, which is qualitatively in good agreement with 2D MHD simulation. It is found and verified that a sufficient mirror field in the confinement region is required for colliding FRCs to be fully merged into a single FRC plasma state.

15.
Transplant Proc ; 49(8): 1956-1959, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28923654

RESUMO

Arterial dissection is a rare complication after liver transplantation (LT). We report a case of extensive isolated spontaneous celiac trunk dissection (ISCTD) up to the proper hepatic artery, left gastric artery, and splenic artery after living donor liver transplantation. A 48-year-old woman with cryptogenic liver cirrhosis underwent living donor liver transplantation. Intraoperative and postoperative Doppler ultrasound revealed sufficient flow in the hepatic artery, portal vein, and hepatic vein. On postoperative day (POD) 10, Doppler ultrasound showed reduction of hepatic arterial flow. On POD 16, a contrast-enhanced computed tomography scan showed that the ISCTD extended to the proper hepatic artery, left gastric artery, and splenic artery with an entry tear on the proximal side of the celiac trunk. Although the computed tomography scan showed ischemia of a small part of the liver, blood flow to the liver was kept to some extent. Because all false lumens were occluded by thrombi and the liver enzyme levels normalized, we chose conservative therapy with antiplatelet agents. The patient was discharged on POD 53. She remains well without any liver dysfunction after 18 months with reduction in all false lumens and a patent hepatic artery. Several cases of ISCTD have been reported apart from LT, most of which were treated with conservative therapy. We conclude that conservative therapy could be the first choice in ISCTD even after LT.


Assuntos
Dissecção Aórtica/terapia , Artéria Celíaca , Embolização Terapêutica , Transplante de Fígado/efeitos adversos , Adulto , Dissecção Aórtica/diagnóstico por imagem , Angiografia , Artéria Celíaca/diagnóstico por imagem , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Trombose/tratamento farmacológico , Tomografia Computadorizada por Raios X , Ultrassonografia Doppler
16.
Transplant Proc ; 49(7): 1649-1651, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28838457

RESUMO

BACKGROUND: Colon cancer accompanying decompensated liver cirrhosis is a rare clinical condition. Usually, treatment of colon cancer is prioritized, with cirrhosis dealt with later. CASE REPORT: We present a case of end-stage liver disease due to nonalcoholic steatohepatitis evaluated for living donor liver transplant. During the pretransplant examination, an ascending colon cancer was detected. Liver function was too poor to perform colon resection first. Simultaneous living donor liver transplant and colonic resection were carried out. The patient developed left lung metastasis at 2 different times during the first postoperative year, and both of them were resected. The patient received the standard chemoradiotherapy. Now, the patient is alive at 42 months postprocedure and recurrence-free at 31 months postoperatively. CONCLUSION: Simultaneous liver transplantation and colon resection are possible with acceptable long-term outcomes. Immunosuppressive therapy after transplantation increases the risk for cancer recurrence. So the patient should undergo close surveillance.


Assuntos
Colectomia/métodos , Neoplasias do Colo/cirurgia , Doença Hepática Terminal/cirurgia , Transplante de Fígado/métodos , Hepatopatia Gordurosa não Alcoólica/cirurgia , Neoplasias do Colo/complicações , Terapia Combinada , Doença Hepática Terminal/etiologia , Feminino , Humanos , Doadores Vivos , Pessoa de Meia-Idade , Hepatopatia Gordurosa não Alcoólica/complicações , Resultado do Tratamento
17.
Bone Joint Res ; 6(7): 439-445, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28747338

RESUMO

OBJECTIVES: We have previously investigated an association between the genome copy number variation (CNV) and acetabular dysplasia (AD). Hip osteoarthritis is associated with a genetic polymorphism in the aspartic acid repeat in the N-terminal region of the asporin (ASPN) gene; therefore, the present study aimed to investigate whether the CNV of ASPN is involved in the pathogenesis of AD. METHODS: Acetabular coverage of all subjects was evaluated using radiological findings (Sharp angle, centre-edge (CE) angle, acetabular roof obliquity (ARO) angle, and minimum joint space width). Genomic DNA was extracted from peripheral blood leukocytes. Agilent's region-targeted high-density oligonucleotide tiling microarray was used to analyse 64 female AD patients and 32 female control subjects. All statistical analyses were performed using EZR software (Fisher's exact probability test, Pearson's correlation test, and Student's t-test). RESULTS: CNV analysis of the ASPN gene revealed a copy number loss in significantly more AD patients (9/64) than control subjects (0/32; p = 0.0212). This loss occurred within a 60 kb region on 9q22.31, which harbours the gene for ASPN. The mean radiological parameters of these AD patients were significantly worse than those of the other subjects (Sharp angle, p = 0.0056; CE angle, p = 0.0076; ARO angle, p = 0.0065), and all nine patients required operative therapy such as total hip arthroplasty or pelvic osteotomy. Moreover, six of these nine patients had a history of operative or conservative therapy for developmental dysplasia of the hip. CONCLUSIONS: Copy number loss within the region harbouring the ASPN gene on 9q22.31 is associated with severe AD. A copy number loss in the ASPN gene region may play a role in the aetiology of severe AD.Cite this article: T. Sekimoto, M. Ishii, M. Emi, S. Kurogi, T. Funamoto, Y. Yonezawa, T. Tajima, T. Sakamoto, H. Hamada, E. Chosa. Copy number loss in the region of the ASPN gene in patients with acetabular dysplasia: ASPN CNV in acetabular dysplasia. Bone Joint Res 2017;6:439-445. DOI: 10.1302/2046-3758.67.BJR-2016-0094.R1.

18.
Nat Commun ; 7: 13860, 2016 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-28000675

RESUMO

An economic magnetic fusion reactor favours a high ratio of plasma kinetic pressure to magnetic pressure in a well-confined, hot plasma with low thermal losses across the confining magnetic field. Field-reversed configuration (FRC) plasmas are potentially attractive as a reactor concept, achieving high plasma pressure in a simple axisymmetric geometry. Here, we show that FRC plasmas have unique, beneficial microstability properties that differ from typical regimes in toroidal confinement devices. Ion-scale fluctuations are found to be absent or strongly suppressed in the plasma core, mainly due to the large FRC ion orbits, resulting in near-classical thermal ion confinement. In the surrounding boundary layer plasma, ion- and electron-scale turbulence is observed once a critical pressure gradient is exceeded. The critical gradient increases in the presence of sheared plasma flow induced via electrostatic biasing, opening the prospect of active boundary and transport control in view of reactor requirements.

19.
Rev Sci Instrum ; 87(11): 11D406, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910693

RESUMO

We have developed a compact toroid (CT) injector system for particle refueling of the advanced beam-driven C-2U field-reversed configuration (FRC) plasma. The CT injector is a magnetized coaxial plasma gun (MCPG), and the produced CT must cross the perpendicular magnetic field surrounding the FRC for the refueling of C-2U. To simulate this environment, an experimental test stand has been constructed. A transverse magnetic field of ∼1 kG is established, which is comparable to the C-2U axial magnetic field in the confinement section, and CTs are fired across it. On the test stand we have been characterizing and studying CT formation, ejection/translation from the MCPG, and penetration into transverse magnetic fields.

20.
Sci Rep ; 6: 35879, 2016 10 24.
Artigo em Inglês | MEDLINE | ID: mdl-27775087

RESUMO

Bulk niobium Superconducting Radio-Frequency cavities are a leading accelerator technology. Their performance is limited by the cavity loss and maximum acceleration gradient, which are negatively affected by vortex penetration into the superconductor when the peak magnetic field at the cavity wall surface exceeds the vortex penetration field (Hvp). It has been proposed that coating the inner wall of an SRF cavity with superconducting thin films increases Hvp. In this work, we utilized Nb ellipsoid to simulate an inverse SRF cavity and investigate the effect of coating it with magnesium diboride layer on the vortex penetration field. A significant enhancement of Hvp was observed. At 2.8 K, Hvp increased from 2100 Oe for an uncoated Nb ellipsoid to 2700 Oe for a Nb ellipsoid coated with ~200 nm thick MgB2 thin film. This finding creates a new route towards achieving higher acceleration gradient in SRF cavity accelerator beyond the theoretical limit of bulk Nb.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...