Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 87(11): 11E105, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910614

RESUMO

The upgraded millimeter-wave interferometer with the frequency of 70 GHz is installed on a large-scaled negative ion source. Measurable line-averaged electron density is from 2 × 1015 to 3 × 1018 m-3 in front of the plasma grid. Several improvements such as the change to shorter wavelength probing with low noise, the installation of special ordered horn antenna, the signal modulation for a high accuracy digital phase detection, the insertion of insulator, and so on, are carried out for the measurement during the beam extraction by applying high voltage. The line-averaged electron density is successfully measured and it is found that it increases linearly with the arc power and drops suddenly at the beam extraction.

2.
Rev Sci Instrum ; 87(2): 02B103, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931985

RESUMO

Experiments by a four-pin probe and photodetachment technique were carried out to investigate the charged particle flows in the beam extraction region of a negative hydrogen ion source for neutral beam injector. Electron and positive ion flows were obtained from the polar distribution of the probe saturation current. Negative hydrogen ion flow velocity and temperature were obtained by comparing the recovery times of the photodetachment signals at opposite probe tips. Electron and positive ions flows are dominated by crossed field drift and ambipolar diffusion. Negative hydrogen ion temperature is evaluated to be 0.12 eV.

3.
Rev Sci Instrum ; 87(2): 02B113, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26931995

RESUMO

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (Hα) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of Hα emission near the bias plate has been clearly observed. The same time trend on Hα intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

4.
Rev Sci Instrum ; 87(2): 02B321, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932049

RESUMO

To improve the performance of negative-ion based neutral beam injection on the Large Helical Device, the accelerator was modified on the basis of numerical investigations. A field limiting ring was installed on the upper side of a grounded grid (GG) support and a multi-slot GG was adopted instead of a multi-aperture GG. As a result, the voltage holding capability is improved and the heat load on the GG decreases by 40%. In addition, the arc efficiency is improved significantly only by replacing the GG.

5.
Rev Sci Instrum ; 87(2): 02B908, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932080

RESUMO

At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H(-) production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

6.
Rev Sci Instrum ; 87(2): 02B936, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26932108

RESUMO

Recent research results on negative-ion-rich plasmas in a large negative ion source have been reviewed. Spatial density and flow distributions of negative hydrogen ions (H(-)) and positive hydrogen ions together with those of electrons are investigated with a 4-pin probe and a photodetachment (PD) signal of a Langmuir probe. The PD signal is converted to local H(-) density from signal calibration to a scanning cavity ring down PD measurement. Introduction of Cs changes the slope of plasma potential local distribution depending upon the plasma grid bias. A higher electron density H2 plasma locally shields the bias potential and behaves like a metallic free electron gas. On the other hand, the bias and extraction electric fields penetrate in a Cs-seeded electronegative plasma even when the electron density is similar. Electrons are transported by the penetrated electric fields from the driver region along and across the filter and electron deflection magnetic fields. Plasma ions exhibited a completely different response against the penetration of electric fields.

7.
Rev Sci Instrum ; 85(11): 11E110, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430289

RESUMO

The neutron profile monitor stably operated at a high-count-rate for deuterium operations in the Large Helical Device has been developed to enhance the research on the fast-ion confinement. It is composed of a multichannel collimator, scintillation-detectors, and a field programmable gate array circuit. The entire neutron detector system was tested using an accelerator-based neutron generator. This system stably acquires the pulse data without any data loss at high-count-rate conditions up to 8 × 10(5) counts per second.

8.
Rev Sci Instrum ; 85(11): 11E114, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430293

RESUMO

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10(9) counts/s. Because a maximum total neutron emission rate over 1 × 10(16) n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

9.
Rev Sci Instrum ; 85(2): 02A724, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593458

RESUMO

A spectrally selective imaging system has been developed to obtain a distribution of Hα emissions at the extraction region in a hydrogen negative ion source. The diagnostic system consisted of an aspherical lens, optical filters, a fiber image conduit, and a charge coupled device detector was installed on the 1/3-scaled hydrogen negative ion source in the National Institute for Fusion Science. The center of sight line passes beside the plasma grid (PG) surface with the distance of 11 mm, and the viewing angle has coverage 35 mm from the PG surface. Two dimensional Hα distribution in the range up to 20 mm from the PG surface was clearly observed. The reduction area for Hα emission caused by beam extraction was widely distributed in the extraction region near the PG surface.

10.
Rev Sci Instrum ; 85(2): 02B131, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24593571

RESUMO

The electron density was measured at various bias voltages to understand how the plasma grid bias affects the electron near the plasma grid in large-scaled negative ion sources. It was found that the response of the electron to the bias voltage changes depending on negative ion production processes. The electron density remarkably decreases with increasing the bias voltage in the pure-volume plasma. On the other hand, the electron density depends on the bias voltage weakly in the Cs-seeded plasma. In addition, it was observed that the response of the co-extracted electron current to the bias voltage has similar trend to that of the electron density.

11.
Rev Sci Instrum ; 83(2): 02A731, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380240

RESUMO

Hydrogen negative ion density measurements are required to clarify the characteristics of negative ion production and ion source performance. Both of laser photodetachment and cavity ring down (CRD) measurements have been implemented to a field-effect-transistor based radio-frequency ion source. The density ratio of negative hydrogen ions to electrons was successfully measured by laser photodetachment and effect of magnetic filter field on negative ion density was confirmed. The calculated CRD signal showed that CRD mirrors with >99.990% reflectivity are required and loss of reflectivity due to cesium contamination should be minimized.

12.
Rev Sci Instrum ; 83(2): 02B113, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380270

RESUMO

Electron density measurements of a large-scaled negative ion source were carried out with a surface wave probe. By comparison of the electron densities determined with the surface wave probe and a Langmuir probe, it was confirmed that the surface wave probe is highly available for diagnostic of the electron density in H(-) ion sources. In addition, it was found that the ratio of the electron density to the H(-) ion density dramatically decreases with increase of a bias voltage and the H(-) ions become dominant negative particles at the bias voltage of more than 6 V.

13.
Rev Sci Instrum ; 83(2): 02B116, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380273

RESUMO

We report on the characteristics of the electronegative plasma in a large-scale hydrogen negative ion (H(-)) source. The measurement has been made with a time-resolved Langmuir probe installed in the beam extraction region. The H(-) density is monitored with a cavity ring-down system to identify the electrons in the negative charges. The electron-saturation current decreases rapidly after starting to seed Cs, and ion-ion plasma is observed in the extraction region. The H(-) density steps down during the beam extraction and the electron density jumps up correspondingly. The time integral of the decreasing H(-) charge density agrees well with the electron charge collected with the probe. The agreement of the charges is interpreted to indicate that the H(-) density decreasing at the beam extraction is compensated by the electrons diffusing from the driver region. In the plasmas with very low electron density, the pre-sheath of the extraction field penetrates deeply inside the plasmas. That is because the shielding length in those plasmas is longer than that in the usual electron-ion plasmas, and furthermore the electrons are suppressed to diffuse to the extraction region due to the strong magnetic field.

14.
Rev Sci Instrum ; 83(2): 02B122, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22380279

RESUMO

H(-) beam was successfully extracted from a cesium seeded ion source operated using a field effect transistor inverter power supply as a radio frequency (RF) wave source. High density hydrogen plasma more than 10(19) m(-3) was obtained using an external type antenna with RF frequency of lower than 0.5 MHz. The source was isolated by an isolation transformer and H(-) ion beam was extracted from a single aperture. Acceleration current and extraction current increased with the increase of extraction voltage. Addition of a small amount of cesium vapor into the source enhanced the currents.

15.
Rev Sci Instrum ; 81(10): 10D310, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033836

RESUMO

Deuterium experiment on the Large Helical Device (LHD) is now being planned at the National Institute for Fusion Science. The fusion product diagnostics systems currently considered for installation on LHD are described in this paper. The systems will include a time-resolved neutron yield monitor based on neutron gas counters, a time-integrated neutron yield monitor based on activation techniques, a multicollimator scintillation detector array for diagnosing spatial distribution of neutron emission rate, 2.5 MeV neutron spectrometer, 14 MeV neutron counter, and prompt γ-ray diagnostics.

16.
Rev Sci Instrum ; 81(10): 10D327, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033849

RESUMO

A tangential Fast Ion Charge eXchange Spectroscopy is newly applied on a Large Helical Device (LHD) for co/countercirculating fast ions, which are produced by high energy tangential negative-ion based neutral beam injection. With this new observation geometry, both the tangential-neutral beam (NB) and a low-energy radial-NB based on positive ions can be utilized as probe beams of the measurement. We have successfully observed Doppler-shifted H-alpha lights due to the charge exchange process between the probing NB and circulating hydrogen ions of around 100 keV in LHD plasmas.

17.
Rev Sci Instrum ; 81(2): 02B107, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192414

RESUMO

Characteristics of radio frequency (RF) plasma production are investigated using a field effect transistor inverter power supply as an RF wave source. With the frequency of around 0.3 MHz, an electron density over 10(18) m(-3) is produced in argon plasma. Although lower densities are obtained in hydrogen plasma, it drastically increased up to 5x10(18) m(-3) with an axial magnetic field of around 100 G applied in the driver region. Effects of the magnetic field and gas pressure are investigated in the RF produced plasma with the frequency of several hundred kilohertz.

18.
Rev Sci Instrum ; 81(2): 02B116, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192422

RESUMO

An additional beamline, BL5, equipped with four positive ion sources will be installed on Large Helical Device (LHD) in 2010. The performance of an ion source which generates 80 keV deuterium and 60 keV hydrogen beams was investigated. The structure of the ion source is based on that of a BL4 ion source on LHD. The main differences between the ion sources for the BL4 and BL5 are the acceleration voltages and the materials of plasma electrodes: copper and molybdenum, respectively. The molybdenum plasma electrode for BL5 has better performance than the copper plasma electrode of BL4. The integrated performance of the ion source for BL5 reached a value equivalent to approximately 58 A in the beam current of hydrogen positive ion at 60 keV in the beam energy.

19.
Rev Sci Instrum ; 81(2): 02B117, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20192423

RESUMO

Characteristics of multibeamlets are investigated by means of beamlet monitoring technique. The beamlets are extracted from an accelerator with multislot grounded grid and the profiles are observed as infrared images of temperature distributions on a cold isostatic pressed graphite plate exposed by H-beamlets. The optimal horizontal and vertical divergence angles of single beamlet are estimated at 4.1 and 6.1 mrad, respectively.

20.
Phys Rev Lett ; 105(14): 145003, 2010 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-21230839

RESUMO

Reversed-shear Alfvén eigenmodes were observed for the first time in a helical plasma having negative q0'' (the curvature of the safety factor q at the zero shear layer). The frequency is swept downward and upward sequentially via the time variation in the maximum of q. The eigenmodes calculated by ideal MHD theory are consistent with the experimental data. The frequency sweeping is mainly determined by the effects of energetic ions and the bulk pressure gradient. Coupling of reversed-shear Alfvén eigenmodes with energetic ion driven geodesic acoustic modes generates a multitude of frequency-sweeping modes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...