Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 199
Filtrar
1.
Q J Nucl Med Mol Imaging ; 52(4): 378-87, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19088692

RESUMO

Iodine-123-labeled metaiodobenzylguanidine (MIBG) has a history of over 20 years as a marker of myocardial sympathetic activity in Japan and has been used for various cardiac diseases. Aside from conventional utilities in patients with cardiac diseases, including ischemic heart diseases, cardiomyopathy, heart failure and diabetes, neurological disorders have recently been drawing special attention. The [(123)I]MIBG study showed markedly decreased myocardial uptake in Parkinson's disease, dementia with Lewy bodies and pure autonomic failure, which is a common feature of Lewy-body diseases. The MIBG study can be used for differentiating patients with extrapyramidal signs and dementia. The unique application of MIBG in movement disorders and related neurological diseases is one of its most common uses in Japan, and further studies are expected worldwide.


Assuntos
3-Iodobenzilguanidina , Doença por Corpos de Lewy/complicações , Doença por Corpos de Lewy/diagnóstico por imagem , Sistema Nervoso Simpático/diagnóstico por imagem , 3-Iodobenzilguanidina/metabolismo , Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/metabolismo , Doença de Alzheimer/fisiopatologia , Diagnóstico Diferencial , Humanos , Doença por Corpos de Lewy/metabolismo , Doença de Parkinson/diagnóstico , Doença de Parkinson/metabolismo , Doença de Parkinson/patologia , Doença de Parkinson/fisiopatologia , Cintilografia , Sistema Nervoso Simpático/metabolismo
2.
J Neurol ; 255(11): 1703-11, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18821045

RESUMO

OBJECTIVE: Lateralization of language function is a prominent feature of human brain function, and its underlying structural asymmetry has been recently reported in normal right-handed subjects. By means of diffusion tensor tractography (DTT), we investigated the asymmetry of the language network, namely, the arcuate fasciculus in patients in whom the unilateral language dominance was defined by Wada test. METHODS: DTT was performed in 24 patients with a focal lesion or an epileptic focus outside the C-shaped segment of the arcuate fasciculus. The arcuate fasciculus was reconstructed by placing two regions-of-interest in the deep white matter lateral to the corona radiata. The pathway was then divided into one terminating in the temporal lobe (FT tract) and the other in the parietal lobe (FP tract). The relative number and volume of the FT and FP tracts in each hemisphere were submitted to repeated measure ANOVA separately, with the hemisphere as a within-subject factor and with the side of pathology as a between subject factor. RESULTS: The FT tract showed a significantly larger number and volume in the language dominant hemisphere than in the non-dominant hemisphere, while, for the FP tract, no significant hemispheric difference was observed in the relative number or volume. There was a tendency that the FT tract was less lateralized when the pathology was located in the dominant hemisphere than in the non-dominant hemisphere. CONCLUSION: Dominance of the FT tract in the language dominant hemisphere was demonstrated for the first time in a patient population and implicated a clinical utility of DTT for non-invasive evaluation of language lateralization. Our preliminary study might indicate reorganization of the language network in conjunction with pathology.


Assuntos
Encefalopatias/patologia , Encéfalo/patologia , Epilepsia/patologia , Lateralidade Funcional/fisiologia , Idioma , Vias Neurais/patologia , Adulto , Análise de Variância , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Malformações Arteriovenosas Intracranianas/patologia , Testes de Linguagem , Masculino , Adulto Jovem
3.
Neuroimage ; 41(4): 1206-19, 2008 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-18468925

RESUMO

The present study investigated the sensitivity of magnetoencephalography (MEG) for spikes depending on sensor type in patients with mesial temporal epileptic focus. We recorded MEG in 6 patients with mesial temporal epileptic focus using two sensor types (magnetometer and gradiometer) simultaneously. The number of spikes detected and the corresponding equivalent current dipole (ECD) parameters (distance from the coordinated head center (radius), and dipole moment) were evaluated with respect to sensor type. Among 426 MEG 'consensus spikes' determined by 3 reviewers, 378 spikes satisfied the predetermined criteria for source localization. Comparing ECD parameters, spikes detected by magnetometer alone displayed a smaller radius and larger dipole moment than those detected by gradiometer alone. Spikes estimated in the mesial temporal area were more frequently detected by magnetometer alone (38.5%) than by gradiometer alone (11.5%), whereas spikes in the lateral temporal area were detected less by magnetometer alone (3.7%) than by gradiometer alone (53.9%). The present results suggest that a magnetometer is advantageous for spike detection in patients with mesial temporal epileptic focus. This also implies the higher sensitivity of magnetometer for deep sources.


Assuntos
Epilepsia do Lobo Temporal/diagnóstico , Magnetoencefalografia/instrumentação , Adolescente , Adulto , Interpretação Estatística de Dados , Eletroencefalografia , Eletrofisiologia , Epilepsia do Lobo Temporal/diagnóstico por imagem , Epilepsia do Lobo Temporal/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Procedimentos Neurocirúrgicos , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
5.
Neurology ; 66(12): 1850-4, 2006 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-16801649

RESUMO

OBJECTIVE: To evaluate the diagnostic reliability of cardiac iodine-123 metaiodobenzylguanidine ((123)I-MIBG) radioactivity in discriminating dementia with Lewy bodies (DLB) from Alzheimer disease (AD) regardless of parkinsonism. BACKGROUND: The diagnosis of DLB may be confounded by the absence of parkinsonism. This highlights the need to improve the accuracy of antemortem diagnosis of DLB without parkinsonism. METHODS: Cardiac sympathetic denervation was examined using myocardial (123)I-MIBG scintigraphy in 37 patients with DLB, 42 patients with AD, and 10 normal elderly controls. The DLB patients consisted of seven patients without parkinsonism (DLB/P-) and 30 patients with parkinsonism (DLB/P+) at the time of the study. RESULTS: The heart-to-mediastinum uptake ratio (H/M ratio) of myocardial MIBG uptake was decreased in both the DLB groups vs the AD group (p < 0.0001) and control group (p < 0.0001). The washout rate (WR) was higher in the DLB group than in the control group (p < 0.0001) and AD group (p < 0.0001). No differences were found between the AD and control groups or between the DLB/P+ and DLB/P- groups in either the early or delayed H/M ratio or WR. In discriminating between DLB and AD, regardless of parkinsonism, the delayed H/M ratio had a sensitivity of 100%, a specificity of 100%, and a positive predictive value of 100% at a cutoff value of 1.68. CONCLUSIONS: Our results indicate that dementia with Lewy bodies results in cardiac sympathetic denervation and that iodine-123 metaiodobenzylguanidine myocardial scintigraphy is a sensitive tool for discriminating dementia with Lewy bodies from Alzheimer disease even in patients without parkinsonism.


Assuntos
3-Iodobenzilguanidina , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/epidemiologia , Doença por Corpos de Lewy/diagnóstico por imagem , Doença por Corpos de Lewy/epidemiologia , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Fatores de Confusão Epidemiológicos , Diagnóstico Diferencial , Feminino , Humanos , Japão/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Neurology ; 65(11): 1813-6, 2005 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-16148262

RESUMO

The authors evaluated adverse effects of intracarotid propofol injection during a Wada test and their risk factors in 58 patients. Nineteen patients had an adverse effect, mostly in patients receiving more than 10 mg. For patients older than age 55 years or those requiring an injection dose greater than 20 mg to produce hemiplegia, propofol should be injected slowly and patients monitored for excitatory movements.


Assuntos
Córtex Cerebral/efeitos dos fármacos , Complicações Pós-Operatórias/prevenção & controle , Cuidados Pré-Operatórios/efeitos adversos , Propofol/efeitos adversos , Adolescente , Adulto , Fatores Etários , Idoso , Anestésicos Intravenosos/efeitos adversos , Córtex Cerebral/fisiologia , Córtex Cerebral/cirurgia , Criança , Relação Dose-Resposta a Droga , Discinesia Induzida por Medicamentos/prevenção & controle , Feminino , Lateralidade Funcional/efeitos dos fármacos , Lateralidade Funcional/fisiologia , Humanos , Injeções Intra-Arteriais/efeitos adversos , Masculino , Memória/efeitos dos fármacos , Memória/fisiologia , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Fala/efeitos dos fármacos , Fala/fisiologia
7.
Nucl Med Commun ; 24(5): 559-63, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12717074

RESUMO

An analysis program for ECG gated, blood pool, single photon emission tomography (SPET GBP) is available. This program permits the automatic evaluation of left and right ventricular function, but its reliability has not been thoroughly assessed. The objective of this investigation was to examine the reliability of the parameters derived from SPET GBP. Fifty-three patients who had undergone both SPET GBP and planar, ECG gated, blood pool scintigraphy (planar GBP) were enrolled in the study. Planar GBP was performed with a single-headed gamma camera. From a left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG gating during the equilibrium state. SPET GBP was carried out utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees, with 60 s per view, in 16 frames/cardiac cycle. Left ventricular ejection fraction (LVEF) and right ventricular ejection fraction (RVEF) were calculated by using the analysis program. The reproducibility of these values and the correlation between SPET and planar GBP were assessed. To evaluate the effect of cut-off frequencies of a Butterworth filter, six different cut-off frequencies (order=8, 0.3-1.0 Nyquist) were tested with data obtained from 12 patients. The reproducibility of LVEF by SPET GBP was satisfactory (intra-observer, r=0.95; inter-observer, r=0.96), whereas reproducibility of RVEF by SPET GBP was fair (intra-observer, r=0.83; inter-observer, r=0.83). LVEF with SPET GBP was well correlated (y=1.1x+6.62, r=0.85, P<0.01) with LVEF readings of planar GBP. However, LVEF with SPET GBP was overestimated (mean difference of 12) in comparison with that of planar GBP. The RVEF derived from SPET GBP showed poor correlation (y=0.52x+33, r=0.53, P<0.01) with planar GBP. No significant effect of cut-off frequencies of Butterworth filters was evident in the calculation of LVEF and RVEF (P=0.48 and 0.67) with SPET GBP. It is concluded that SPET GBP with QBS is useful for the evaluation of LVEF. However, measurement of the RVEF showed lower reproducibility compared with measurement of the LVEF.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/métodos , Interpretação de Imagem Assistida por Computador/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Direita/diagnóstico
8.
Nucl Med Commun ; 24(3): 327-30, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12612475

RESUMO

Radiological diagnosis of deep soft tissue is often difficult. In the present study, thallium-201 ( Tl) uptake into haemangiomas and deep malignant soft tissue tumours was investigated in order to assess its clinical utility. Tl scintigraphy was reviewed in four patients presenting with soft tissue haemangiomas. Early and delayed planar images, obtained at 15 min and 3 h following the intravenous injection of Tl (111 MBq), were examined. The Tl uptake ratio was calculated by dividing the count density of the tumour region of interest (ROI) by that of the background ROI. Results were compared with those of five cases of rhabdomyosarcoma and a single instance of angiosarcoma. All haemangioma lesions demonstrated increased Tl uptake in early images. However, Tl uptake in delayed images was markedly decreased. No significant differences were observed in the early uptake ratio between haemangiomas (1.60-2.72) and reference malignant tumours (1.48-2.45); however, the difference was significant in delayed images (range, 1.01-1.26 vs. 1.43-2.03, respectively) ( P<0.02). Deep soft tissue haemangiomas revealed Tl accumulation in early images; however, a rapid washout was observed in delayed images. This distinctive feature may facilitate the use of Tl scintigraphy in the diagnosis of haemangiomas.


Assuntos
Hemangioma/diagnóstico por imagem , Rabdomiossarcoma/diagnóstico por imagem , Neoplasias de Tecidos Moles/diagnóstico por imagem , Radioisótopos de Tálio/farmacocinética , Adolescente , Adulto , Idoso , Transporte Biológico , Criança , Diagnóstico Diferencial , Feminino , Hemangioma/metabolismo , Hemangiossarcoma/diagnóstico por imagem , Hemangiossarcoma/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Rabdomiossarcoma/metabolismo , Neoplasias de Tecidos Moles/metabolismo , Distribuição Tecidual
9.
Nucl Med Commun ; 23(11): 1115-21, 2002 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12411841

RESUMO

The clinical applicability of dynamic single photon emission tomograpy (SPET) using a dual-head gamma camera equipped with a slip-ring rotational mechanism, referred to as serial SPET, was examined in the present investigation. Serial SPET enables the production of tomographic images for any arbitrary time frame from an arbitrary range of data to 360 degrees. In a pre-clinical evaluation, a correlation between radioactivity concentration and serial SPET counts was evaluated in a phantom with continuous changes in 99mTc concentration. A differential value was obtained from each pair of SPET images; moreover, moving average approximation processing was investigated with respect to the elimination of noise in the data. In 11 and one patient presenting with cerebrovascular disease and meningioma, respectively, changes in SPET counts were evaluated when 99mTc ethyl cysteinate dimer (99mTc-ECD) was continuously administered at a constant rate in the resting state. Furthermore, in six of 11 subjects with cerebrovascular disease, changes occurring in SPET counts were examined by using acetazolamide loading while continuously administering 99mTc-ECD at a constant rate. Consequently, serial SPET enabled the evaluation of changes in radioactivity concentration over time in both the phantom and preliminary clinical studies. Data analysis by differential processing utilizing moving average approximation processing enabled the detection of minor changes in radioactivity concentration. An increase of 15.1+/-5.4% was observed in SPET counts of the unaffected cerebral hemisphere with acetazolamide loading. The response of the affected hemisphere was less prominent. These findings suggest that serial SPET would be an effective technique for the pharmacokinetic analysis of radiopharmaceuticals.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Transtornos Cerebrovasculares/metabolismo , Cisteína/análogos & derivados , Cisteína/farmacocinética , Meningioma/metabolismo , Compostos de Organotecnécio/farmacocinética , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Acetazolamida , Idoso , Transtornos Cerebrovasculares/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Câmaras gama , Humanos , Masculino , Meningioma/diagnóstico por imagem , Pessoa de Meia-Idade , Imagens de Fantasmas , Controle de Qualidade , Compostos Radiofarmacêuticos/farmacocinética , Rotação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação
10.
Nucl Med Commun ; 23(6): 595-9, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12029217

RESUMO

The aim of this study was to determine the characteristics and clinical usefulness of 201Tl scintigraphy in giant-cell tumour of bone (GCT). Twenty-one patients with histopathologically proven benign GCT (22 lesions; 18 primary and four recurrent) underwent 201Tl scintigraphy. We also studied conventional osteosarcoma (10 lesions), a very common primary malignant bone tumour; and chordoma in the sacrum (four lesions), an entity requiring differential diagnosis from GCT of the sacrum. Early and delayed planar imaging was performed at 15 min (early) and 3 h (delayed) after the intravenous injection of 201Tl chloride (111 MBq). The Tl uptake ratio was calculated by dividing the count density of the tumour region of interest (ROI) by that of the background ROI. All GCT lesions showed increased Tl uptake in both early and delayed images. The mean Tl uptake ratios of primary GCT were 4.7 (range, 2.0-11.1) in the early images and 2.2 (range, 1.4-3.6) in the delayed images, and those of recurrent lesions were 5.8 (range, 2.4-11.5) in the early images and 2.7 (range, 2.0-4.3) in the delayed images. There were no significant differences between the uptake ratios in GCT and osteosarcoma, but the values of GCT tended to be higher than those of osteosarcoma, 3.1 (range, 1.7-4.4) in the early images and 1.8 (range, 1.3-2.3) in the delayed images. Chordoma did not show appreciable Tl uptake: the uptake ratio was 1.19 (range, 0.98-1.5) in the early images and 1.1 (range, 1.0-1.3) in the delayed images. In GCT, a benign lesion, Tl scintigraphy demonstrated marked uptake in both primary and recurrent lesions with no exceptions, precluding the use of Tl scintigraphy for the differential diagnosis of GCT from malignant tumours. However, the Tl scintigraphy can be used for excluding GCT when no lesional Tl uptake is observed, and diagnosing recurrent lesions on post-operative follow-up.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Cordoma/diagnóstico por imagem , Tumor de Células Gigantes do Osso/diagnóstico por imagem , Ossos da Perna/diagnóstico por imagem , Sacro/diagnóstico por imagem , Tálio , Adulto , Neoplasias Ósseas/metabolismo , Cordoma/metabolismo , Diagnóstico Diferencial , Feminino , Tumor de Células Gigantes do Osso/metabolismo , Humanos , Ossos da Perna/metabolismo , Masculino , Osteossarcoma , Valor Preditivo dos Testes , Cintilografia , Compostos Radiofarmacêuticos/farmacocinética , Estudos Retrospectivos , Sacro/metabolismo , Sensibilidade e Especificidade , Tálio/farmacocinética
11.
Ann Nucl Med ; 15(4): 381-5, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11577766

RESUMO

We report a rare case of double cancers with myocardial metastasis presenting acute myocardial infarction (AMI)-like findings both on an electrocardiogram (ECG) and on Tc-99m-MIBI myocardial SPECT. The ECG showed abnormal Q-waves and ST-segment elevation in leads V1-V4, and Tc-99m-MIBI SPECT showed a photon deficient area in the anteroseptum. These findings were suggestive of AMI, but the patient had been simultaneously suffering from two adenocarcinomas, which were lung cancer and gastric cancer, and consecutive ultrasonic cardiography (UCG) demonstrated a growing mass lesion in the septal aspect of the left ventricle. After a month he died of severe heart failure. The histological diagnosis of a specimen of the cardiac mass lesion was invasive adenocarcinoma infiltrating to the heart, which revealed that the myocardial metastasis had mimicked AMI. This case shows that it is difficult to distinguish between myocardial infarction and myocardial metastasis with myocardial perfusion SPECT. It is necessary to consider the possibility of myocardial metastasis when a patient with malignancy presents AMI-like findings.


Assuntos
Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/secundário , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico , Neoplasias Primárias Múltiplas/diagnóstico por imagem , Neoplasias Primárias Múltiplas/diagnóstico , Adenocarcinoma/diagnóstico , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/secundário , Idoso , Diagnóstico Diferencial , Eletrocardiografia , Neoplasias Cardíacas/diagnóstico , Humanos , Neoplasias Pulmonares/diagnóstico , Masculino , Compostos Radiofarmacêuticos , Neoplasias Gástricas/diagnóstico , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único
12.
Eur J Nucl Med ; 28(10): 1512-6, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11685494

RESUMO

The aim of this study was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling by the edge detection method with ECG-gated single-photon emission tomography (G-SPET) data. Fifty-two patients who had undergone both G-SPET and gated equilibrium blood pool scintigraphy (GBP) within an interval of 2 weeks were enrolled. For G-SPET, 740 MBq of technetium-99m methoxyisobutylisonitrile (MIBI) was injected at rest, and myocardial SPET was performed 60 min later using 360 degrees acquisition and 12 frames per cardiac cycle. In each frame, left ventricular volume was determined with automatic edge detection using a quantitative gated SPET program, and the time-volume curve was fitted by Fourier transform of the first to fourth harmonics. Ejection fraction (EF, %), peak ejection rate (PER, /s), peak filling rate (PFR, /s) and mean filling rate during the first third of diastolic time (1/3FRm, /s) were calculated from the fitted curve. These parameters were also calculated by means of GBP performed with 24 frames per cardiac cycle. Correlation coefficients in respect of EF, PER, PFR and 1/3FRm between G-SPET and GBP were 0.90 (P<0.001), 0.88 (P<0.001), 0.80 (P<0.001) and 0.82 (P<0.001), respectively. The correlations were good for EF, PER and 1/3FRm. Gated SPET dV/dt parameters were slightly lower compared with GBP values owing to the limited number of frames per cardiac cycle. It is concluded that left ventricular ejection and filling rates can be calculated using G-SPET with edge detection software, and in this study these parameters were significantly correlated with those derived using GBP. Diastolic abnormality on gated SPET study should be recognised as a positive finding, and appropriate gated SPET parameters should be further investigated.


Assuntos
Eletrocardiografia , Imagem do Acúmulo Cardíaco de Comporta , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Humanos , Pessoa de Meia-Idade , Contração Miocárdica , Estudos Retrospectivos
13.
J Nucl Med ; 42(10): 1457-63, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11585857

RESUMO

UNLABELLED: The aim of the study was to investigate the increase in myocardial (99m)Tc-methoxyisobutylisonitrile (sestamibi) retention in humans during pharmacologic vasodilation. METHODS: For calculation of the increase in (99m)Tc-sestamibi retention during hyperemia, baseline and adenosine triphosphate (ATP)-induced hyperemic stress sestamibi studies were performed using a same-day rest-stress protocol. On the injection of sestamibi, left ventricular dynamic data were obtained for 90 s. The increase in sestamibi retention from baseline to hyperemia was calculated by the formula [abstract: see text] where Cm(h)(t) and Cm(b)(t) are myocardial counts on the tomographic image, and Cb(b)(tau) and Cb(h)(tau) are the left ventricular blood-pool counts during the first transit of sestamibi at baseline and during hyperemia, respectively. Coronary flow increase during intravenous ATP stress was measured using intracoronary Doppler flow guide wire and compared with the scintigraphic results of 28 measurements in 22 patients. RESULTS: Sestamibi retention increased as coronary flow velocity increased but plateaued at >2.5-3 times baseline flow velocity. The relationship between the increase in sestamibi retention (Y) and the increase in flow (X) is expressed as follows: Y = 0.44 + 0.60X - 0.068X(2) (r = 0.82). CONCLUSION: In humans, the increase in (99m)Tc-sestamibi myocardial retention underestimates coronary flow reserve, particularly at high flow rates. Knowledge of these tracer retention characteristics will contribute to a more comprehensive understanding of the manner and interpretation of stress sestamibi imaging.


Assuntos
Velocidade do Fluxo Sanguíneo , Circulação Coronária/efeitos dos fármacos , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Ultrassonografia Doppler , Trifosfato de Adenosina/farmacologia , Idoso , Feminino , Humanos , Hiperemia/induzido quimicamente , Masculino , Vasodilatação/efeitos dos fármacos
14.
J Nucl Med ; 42(10): 1571-8, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11585875

RESUMO

UNLABELLED: Gated myocardial perfusion SPECT has been used to calculate ejection fraction (EF) and end-diastolic volume (EDV) and has correlated well with conventional methods. However, the comparative accuracy of and correlations across various types of gated SPECT software are not well understood. METHODS: Mathematic phantoms of cylindric-hemispheric hybrid models, ranging in volume from 34 to 266 mL, were generated. The clinical cases consisted of 30 patients who participated in a radionuclide angiography and gated blood-pool (GBP) study in addition to undergoing (99m)Tc-sestamibi gated SPECT. Four kinds of software, Quantitative Gated SPECT (QGS), the Emory Cardiac Toolbox (ECT), 4D-MSPECT, and Perfusion and Functional Analysis for Gated SPECT (pFAST) were used to compute EF and EDV, and the results were analyzed by multiple comparisons tests. Patients were classified into 4 groups (i.e., no defect, small defect, large defect, and small heart) so that factors affecting variation could be analyzed. RESULTS: In mathematic models > or = 74 mL, volume error was within +/-15%, whereas for a small volume (34 mL), QGS and 4D-MSPECT underestimated the volume and pFAST overestimated it. The respective intra- and interobserver reproducibility of the results was good for QGS (r = 0.99 and 1.00), ECT (r = 0.98 and 0.98), and 4D-MSPECT (r = 0.98 and 0.98) and fair for pFAST (r = 0.88 and 0.85). The correlation coefficient for EF between gated SPECT and the GBP study was 0.82, 0.78, 0.69, and 0.84 for QGS, ECT, 4D-MSPECT, and pFAST, respectively. The correlation coefficient for EDV between gated SPECT and the GBP study was 0.88, 0.89, 0.85, and 0.90, respectively. Although good correlation was observed among the 4 software packages, QGS, ECT, and 4D-MSPECT overestimated EF in patients with small hearts, and pFAST overestimated the true volume in patients with large perfusion defects. Correlation coefficients among the 4 kinds of software were 0.80-0.95 for EF and 0.89-0.98 for EDV. CONCLUSION: All 4 software programs showed good correlation between EF or EDV and the GBP study. Good correlation was observed also between each pair of quantification methods. However, because each method has unique characteristics that depend on its specific algorithm and thus behaves differently in the various patient subgroups, the methods should not be used interchangeably.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta , Software , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único , Circulação Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Variações Dependentes do Observador , Imagens de Fantasmas , Angiografia Cintilográfica , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tecnécio Tc 99m Sestamibi
15.
J Nucl Med ; 42(10): 1579-85, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11585876

RESUMO

UNLABELLED: SPECT with (18)F-FDG has emerged as an alternative to dedicated PET for the assessment of myocardial viability. However, whether FDG SPECT can reliably quantify the extent of viable and scarred myocardium is uncertain. The aim of this study was to investigate whether SPECT with an (18)F-labeled agent would provide information on defect size similar to that provided by dedicated PET. METHODS: Imaging was performed using an elliptic cylinder chest phantom with simulated bone, lung, mediastinum, liver, and heart. (18)F was administered into the myocardium, mediastinum, right and left ventricular cavities, and liver. Plastic inserts (n = 11) ranging in size from 2% to 60% of the myocardium were used to simulate transmural myocardial infarctions. The chest phantom was imaged with a dedicated PET camera and with a double-head SPECT camera equipped with ultra-high-energy collimators. Both SPECT and PET data were analyzed using a semiquantitative polar map approach. Defects were quantified using various cutoff thresholds ranging from 30% to 80% of peak activity and were expressed as a percentage of the left ventricular myocardium. Defect size as measured by SPECT or PET was compared with true defect size. RESULTS: The measured SPECT defect size was highly variable depending on the cutoff used, whereas PET defect size was relatively constant over the range of cutoffs tested. The mean absolute difference between measured and true defect sizes was minimal at a cutoff of 50% of peak activity for both SPECT (3.3% +/- 3.3%) and PET (2.7% +/- 2.5%). For this threshold, both SPECT and PET measurements showed an excellent correlation with true defect size (r = 0.98 for SPECT and 0.99 for PET). The correlation between SPECT and PET measurements was also excellent (r = 0.99; P < 0.01). CONCLUSION: If an appropriate threshold is used to define a defect, SPECT with an (18)F-labeled agent can accurately measure defect size similarly to the manner of PET.


Assuntos
Fluordesoxiglucose F18 , Coração/diagnóstico por imagem , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada de Emissão , Humanos , Miocárdio/patologia , Imagens de Fantasmas , Análise de Regressão
16.
J Neurol Neurosurg Psychiatry ; 71(5): 583-8, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11606666

RESUMO

OBJECTIVE: Scintigraphy with [(123)I]metaiodobenzyl guanidine ([(123)I]MIBG) enables the quantification of postganglionic sympathetic cardiac innervation. Recently, myocardial [(123)I]MIBG scintigraphy has been found to be useful in distinguishing Parkinson's disease, a Lewy body disease, from other akinetic rigid syndromes. Some patients initially diagnosed with dementia of the Alzheimer's type (DAT) are discovered to have an alternative disease such as dementia with Lewy bodies (DLB), despite the application of stringent diagnostic criteria. In the present study, examinations were performed to clarify the usefulness of myocardial [(123)I]MIBG scintigraphy in improving the differential diagnosis between patients with DLB and DAT. METHODS: Fourteen patients with DLB and 14 patients with DAT underwent scintigraphy with [(123)I]MIBG, combined with orthostatic tests and cardiac examinations. RESULTS: In all patients with DLB, the heart to mediastinum (H/M) ratio of MIBG uptake was pathologically impaired in both early and delayed images, independently of the duration of disease and autonomic failure. All patients with DAT had successful MIBG uptake in the heart regardless of duration of disease and autonomic failure. Orthostatic hypotension was seen in four patients with DAT and 13 patients with DLB. CONCLUSIONS: [(123)I]MIBG myocardial scintigraphy might detect early disturbances of the sympathetic nervous system in DLB and might provide useful diagnostic information to discriminate DLB from DAT. The distinction between DLB and DAT may be improved by greater emphasis on cardiac sympathetic disturbances.


Assuntos
3-Iodobenzilguanidina , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/fisiopatologia , Coração/diagnóstico por imagem , Coração/fisiopatologia , Doença por Corpos de Lewy/diagnóstico , Doença por Corpos de Lewy/fisiopatologia , Compostos Radiofarmacêuticos , Sistema Nervoso Simpático/fisiopatologia , 3-Iodobenzilguanidina/farmacocinética , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Hipotensão Ortostática/diagnóstico , Masculino , Pessoa de Meia-Idade , Miocárdio , Testes Neuropsicológicos , Cintilografia/métodos , Compostos Radiofarmacêuticos/farmacocinética , Fatores de Tempo
17.
Radiology ; 221(1): 201-6, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11568341

RESUMO

PURPOSE: To assess thallium 201 ((201)Tl) single photon emission computed tomography (SPECT) for evaluation of thymic lesions associated with myasthenia gravis (MG), including lymphoid follicular hyperplasia (LFH) and thymoma. MATERIALS AND METHODS: (201)Tl SPECT and computed tomography (CT) were performed preoperatively in 46 patients with MG who had undergone thymectomy. SPECT was conducted 15 (early image) and 180 (delayed image) minutes after (201)Tl injection. Results were visually assessed, and (201)Tl uptake ratios (thymic lesion count density/lung count density) were measured for quantitative analysis. Uptake was analyzed among the normal thymus, LFH, and thymoma patient groups. RESULTS: Histopathologic results indicated a normal thymus, LFH, and thymoma in 19, 16, and 11 patients, respectively. Mean uptake ratios in the normal thymus, LFH, and thymoma were 0.96 (95% CI: 0.90, 1.03), 1.14 (95% CI: 1.04, 1.25), and 1.87 (95% CI: 1.56, 2.25), respectively, on early images and 1.09 (95% CI: 1.00, 1.18), 1.65 (95% CI: 1.48, 1.85), and 2.03 (95% CI: 1.65, 2.50), respectively, on delayed images. Thymoma showed more intense (201)Tl accumulation than did the normal thymus (P <.001) and LFH (P <.001) on early images. Both thymoma (P <.001) and LFH (P <.001) displayed more intense uptake than did the normal thymus on delayed images. CONCLUSION: (201)Tl SPECT can enable differentiation between normal thymus, LFH, and thymoma in patients with MG.


Assuntos
Miastenia Gravis/complicações , Radioisótopos de Tálio , Hiperplasia do Timo/diagnóstico por imagem , Neoplasias do Timo/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Cuidados Pré-Operatórios , Timoma/diagnóstico por imagem , Tomografia Computadorizada por Raios X
18.
Semin Musculoskelet Radiol ; 5(2): 177-82, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11500163

RESUMO

(201)Tl scintigraphy provides important information for the management of patients with bone tumors. Although the role for staging the disease of bone tumors and for differentiation of benign from malignant lesions is limited, (201)Tl scintigraphy reflects the disease activity after treatment and it should be used to determine the treatment response and for early diagnosis of recurrence. Baseline study is essential for future reference to evaluate the response to preoperative chemotherapy and to detect recurrence after surgery. Sequential (201)Tl scintigraphy before and after treatment is useful in assessing the grade of response of the tumor to chemotherapy. The early prediction of chemotherapeutic effect by (201)Tl scintigraphy during treatment will affect the management of patients who do not respond to the therapy. This is of special importance to determine whether the patient needs an amputation or a limb-salvage surgery.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Radioisótopos de Tálio , Antineoplásicos/uso terapêutico , Neoplasias Ósseas/tratamento farmacológico , Humanos , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único
19.
Am Heart J ; 142(2): 358-62, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11479478

RESUMO

BACKGROUND: QT dispersion (QTD) reflects regional variation of ventricular repolarization. However, the relationship between QTD and the regional variation of cardiac sympathetic nerve activity in hypertrophic cardiomyopathy (HCM) is not yet elucidated. METHODS: Cardiac sympathetic nerve activity was evaluated in 25 patients with HCM by iodine 123 metaiodobenzylguanidine (MIBG) myocardial scintigraphy. With planar MIBG imaging, heart and mediastinum ratios (H/M) at early (20 minutes) and delayed (3 hours) acquisition and the washout rate (WR) were calculated. Polar maps of left ventricular myocardium were divided into 20 segments. The SD of early uptake (EU-SD), delayed uptake (DU-SD), and WR (WR-SD) in 20 segments as indices of regional variation were calculated. QT intervals were corrected by use of the Bazett formula. RESULTS: Maximum QTc correlated positively with H/M early, WR, and left ventricular wall thickness (LVWT). Minimum QTc correlated positively with WR and LVWT. Corrected QTD (QTDc) correlated negatively with EU-SD, DU-SD, and WR-SD and positively with the interventricular septal thickness/posterior wall thickness ratio. Stepwise regression analysis revealed that the most powerful determinants for maximum QTc, minimum QTc, and QTDc were WR, LVWT, and EU-SD, respectively. CONCLUSIONS: QTD correlated negatively rather than positively with the regional variability index of cardiac sympathetic nerve activity. These results suggest that increased QTD in patients with HCM may not reflect increased heterogeneity of cardiac sympathetic nerve activity.


Assuntos
Arritmias Cardíacas/fisiopatologia , Cardiomiopatia Hipertrófica/fisiopatologia , Ventrículos do Coração/inervação , Sistema Nervoso Simpático/fisiologia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Ecocardiografia Transesofagiana , Feminino , Humanos , Radioisótopos do Iodo , Masculino , Pessoa de Meia-Idade , Cintilografia , Sistema Nervoso Simpático/diagnóstico por imagem
20.
Cancer ; 91(12): 2447-53, 2001 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-11413537

RESUMO

BACKGROUND: This study examined the effect of myocutaneous inflammatory changes caused by intra-arterial chemotherapy on the outcome of patients who undergo limb-saving surgery. METHODS: One hundred seven patients with malignant bone and soft tissue tumors were administered intra-arterial cisplatin and caffeine preoperatively with or without doxorubicin. Nine patients (8.4%) who had had myocutaneous inflammatory reactions were reviewed to determine the effects of this complication on limb-saving surgery. RESULTS: The patients complained of unbearable and continuous pain while undergoing intra-arterial infusion. Gait disturbances and muscle weakness were caused by their severe regional pain, resulting in the use of crutches even before surgery. Extended areas of necrotic skin and muscle were resected simultaneously with limb-saving surgery on four patients. Myocutaneous necrosis in one patient, indurations in two patients, and flares in two patients were not treated surgically. Pain relief was provided to eight patients at some point. Four patients with extensive myocutaneous necrosis around the knee joint had restricted range of motion and poor functional results. Radionuclide angiography using 99m-Technetium-macroaggregated albumins was performed to evaluate the blood flow to the affected muscle and tumor. It showed marked increase of the radioisotope perfusion in the affected muscles but little uptake in the tumor. These results may suggest that the affected muscles diminish the effects of anticancer drugs on the tumors. CONCLUSIONS: Myocutaneous inflammatory reactions should be prevented if possible to obtain good limb function and chemotherapeutic effects in patients who undergo intra-arterial chemotherapy. Resection of necrotic tissue is mandatory to relieve pain.


Assuntos
Antineoplásicos/administração & dosagem , Neoplasias Ósseas/terapia , Dermatite/etiologia , Infusões Intra-Arteriais/efeitos adversos , Miosite/etiologia , Terapia de Salvação , Neoplasias de Tecidos Moles/terapia , Adolescente , Adulto , Neoplasias Ósseas/diagnóstico por imagem , Cafeína/administração & dosagem , Criança , Terapia Combinada , Dermatite/diagnóstico por imagem , Doxorrubicina/administração & dosagem , Feminino , Humanos , Masculino , Miosite/diagnóstico por imagem , Necrose , Osteossarcoma/terapia , Cintilografia , Sarcoma Sinovial/terapia , Neoplasias de Tecidos Moles/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA