Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Kaku Igaku ; 39(1): 13-20, 2002 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-11915308

RESUMO

UNLABELLED: Use of a standard arterial input function and calibrating it by a single blood sample or a continuous arterial blood sample has been researched for a repeat CBF assessment with split-dose administration of N-isopropyl-p[123I]iodoamphetamine (IMP). METHODS: The study population consisted of 5 normal volunteers and 5 patients with cerebrovascular disease. IMP was injected twice (111 MBq/2 ml each) into the anti-cubital vein at a constant infusion speed for 1 min. The arterial input function was monitored during the study including a continuous measurement of radioactivity concentration of both the whole-blood and the octanol-soluble component (Real-Input Function, RIF). Standard input function was determined, and was calibrated either by a single blood sample or a continuous blood sample to estimate the Estimated-Input Function (EIF). Area-Under-the Curve (AUC) was then compared between RIF and EIF. RESULTS: In case EIF was estimated with a single blood sample, the minimum error of estimated AUC was obtained when calibrated at 7 minutes after either the 1st or 2nd injections. Deviation of AUC for [0, 30] was +/- 6.6%, and +/- 5.0%, respectively. If calibrated with a continuous blood sample, the minimum error of AUC with the continuous blood sampling period of 10 min for [0, 30] and [30, 60] was +/- 5.3% and +/- 4.0%, respectively. CONCLUSIONS: AUC of EIF with either a single or continuous blood sampling appeared to have reasonably small errors, suggesting the validity of the use of standardized input function in the split-dose IMP SPECT.


Assuntos
Radioisótopos do Iodo/administração & dosagem , Iofetamina/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia Computadorizada de Emissão de Fóton Único/normas , Adulto , Idoso , Coleta de Amostras Sanguíneas/métodos , Calibragem/normas , Circulação Cerebrovascular , Transtornos Cerebrovasculares/diagnóstico por imagem , Transtornos Cerebrovasculares/fisiopatologia , Feminino , Humanos , Radioisótopos do Iodo/normas , Iofetamina/normas , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/normas , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...