Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 91(3): 1225-1238, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38013214

RESUMO

PURPOSE: This paper presents a novel computational approach to optimize gradient array performance for a given pulse sequence. Specifically, we propose an electromagnetic (EM) approach that minimizes eddy losses within the cryostat while maintaining key performance parameters such as field linearity, gradient strength, and imaging region's dimension and position. METHODS: High-resolution EM simulations on the cryostat's surface are deployed to compute the net EM fields generated by each element of a gradient array coil at different frequencies. The computed fields are stored and combined for each frequency to form a quadratic vector-matrix-vector computation. The overall time-average eddy power loss within the cryostat assembly for arbitrary pulse sequences is computed using frequency domain superposition. RESULTS: The proposed approach estimates and regulates eddy power losses within the cryostat assembly. When compared to the stray field minimization approach, it can achieve over twice the reduction in eddy power loss. The proposed approach eliminates the need to sample the stray fields on the cryostat surface, which the number and position of the samples would be challenging when designing tunable array coils with capabilities that disrupt field symmetries. Additionally, the loss calculation considers the entire cryostat assembly rather than just the inner cylindrical surface of the warm shield. CONCLUSION: Our findings highlight the efficacy of an on-the-fly tuning method for the development of high-performance whole-body gradient array coils, effectively mitigating eddy losses within the cryostat and minimizing stray fields outside the coil assembly. This approach proves particularly advantageous for array coils with variable feeding currents.


Assuntos
Campos Eletromagnéticos , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento
2.
Magn Reson Med ; 88(6): 2718-2731, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35916334

RESUMO

PURPOSE: An array-based z-gradient coil with a set of programmable power amplifiers can outperform a conventional z-gradient coil and make it highly customizable with a broader range of tunable features. METHODS: A dynamically adjustable imaging volume can be achieved using a pair of independent arrays and a modified optimization procedure based on analytic equations. Two modes of operation are provided: (a) standard mode that resembles a conventional coil; (b) advanced mode, where all performance parameters can be adjusted employing a controllable feeding mechanism. Commercial software is used to demonstrate the validity and feasibility of the proposed coil. RESULTS: Primary and shield array diameters are 24 and 30 cm, both of which comprise 12 bundles of 10 turns copper wires. Maximum feeding voltage/current is 250 V/100 A for all array elements. Four distinct magnetic profiles are provided: (a) conventional profile with 140 mm diameter spherical region of interest, 120 mT/m gradient, and up to 4500 T/m/s slew rate; (b) profile of 200 mT/m, 70 mm region of interest, and up to 6900 T/m/s slew rate; (c) 60 mm axially shifted 70 mm region of interest with 120 mT/m strength and 3600 T/m/s slew rate; and (d) profile of 370 mT/m, 120 mm region of interest, and 3700 T/m/s slew rate when the active shield is reverse fed. CONCLUSION: By using an active-shielded gradient array coil, the magnetic field profile of the imaging volume can be adjusted dynamically, and it can provide new features and a wide range of field profiles for diverse applications in MRI.


Assuntos
Cobre , Imageamento por Ressonância Magnética , Desenho de Equipamento , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA