Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J AAPOS ; 28(1): 103802, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38219921

RESUMO

BACKGROUND: Virtual reality field testing may provide an alternative to standard automated perimetry. This study evaluates a virtual reality game-based automated perimetry in a healthy pediatric population. METHODS: A prospective series of pediatric patients at one institution who performed VisuALL perimetry (Olleyes Inc, Summit, NJ) using a game-based algorithm. Participants were examined by an experienced pediatric optometrist or ophthalmologist, who confirmed that there was no evidence of ocular disease expected to affect visual fields. Testing was performed binocularly, with the child wearing their spectacle correction in place. Age, refractive error, test duration, false positives, and stereoacuity were evaluated for associations with performance on VisuALL, as defined by mean deviation (MD) and pattern standard deviation (PSD). RESULTS: A total of 191 eyes of 97 patients (54% female) were included, with a mean age of 11.9 ± 3.1 years. The average MD was -1.82 ± 3.5 dB, with a mean foveal sensitivity of 32.0 ± 4.7 dB. Fifty-nine eyes (30.9%) had MD < -2 dB. Better performance, as assessed by MD and PSD, was associated with shorter test duration (P < 0.001) and older age (P < 0.001). False positives (P = 0.442), wearing spectacles (P = 0.092), Titmus stereoacuity (P = 0.197), and refractive error (P = 0.120) did not appear to be associated with improved performance, adjusting for age as a covariate. CONCLUSIONS: VisuALL virtual reality field testing was well tolerated in this pediatric study cohort. Older age and shorter test duration were associated with better performance on field testing.


Assuntos
Erros de Refração , Testes de Campo Visual , Humanos , Criança , Feminino , Adolescente , Masculino , Campos Visuais , Transtornos da Visão , Olho , Erros de Refração/diagnóstico , Erros de Refração/terapia
2.
J AAPOS ; 27(5): 265.e1-265.e5, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37633411

RESUMO

BACKGROUND: Handheld optical coherence tomography (HH-OCT) lacks integrated segmentation/analysis software. Optic neuropathies cause ganglion cell layer (GCL) thinning, with normal to thickened inner nuclear layer (INL), suggesting the potential value of estimating the GCL/INL ratio on single-line foveal HH-OCT scans. This study determines this ratio in macular scans from healthy eyes of young children using HH-OCT and overhead-mounted OCT. METHODS: Macular OCT scans were obtained using either HH-OCT or overhead-mounted Spectralis FLEX-OCT in children ages 0-5 years undergoing clinically indicated anesthesia/sedation. Exclusion criteria included gestational age <37 weeks, neurologic disease, amblyopia, ocular disease, or large refractive error (spherical equivalent beyond -3.00 D to +8.00 D). For HH-OCT, the GCL and INL were manually measured in pixels from single-line macular scans at the thickest point nasal and temporal to the fovea. For FLEX-OCT images, measurements were aided by automated software. RESULTS: HH-OCT was obtained on 38 eyes (38 children, mean age 2.4 ± 1.8 years) and FLEX-OCT on 56 eyes (56 children, mean age 2.3 ± 1.5 years). Mean nasal GCL/INL was 1.24 ± 0.18 (min/max = 0.92/1.75) for HH-OCT and 1.29 ± 0.18 (min/max = 0.96/1.66) for FLEX-OCT (P = 0.11). Mean temporal GCL/INL was 1.22 ± 0.24 (min/max = 0.66/1.70) for HH-OCT and 1.19 ± 0.16 (min/max = 0.86/1.47) for FLEX-OCT (P = 0.47). CONCLUSIONS: Mean normative GCL/INL ratios were approximately 1.2 at the thickest macular areas both nasal and temporal to the fovea, with either HH-OCT or FLEX-OCT in young children's eyes. These values may prove useful when HH-OCT is used to assess optic neuropathies, in which the GCL/INL ratio is expected to be decreased.


Assuntos
Doenças do Nervo Óptico , Tomografia de Coerência Óptica , Humanos , Criança , Pré-Escolar , Lactente , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina , Retina , Fóvea Central
3.
J Invasive Cardiol ; 34(6): E428-E432, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35551106

RESUMO

BACKGROUND: The Auryon 355-nm laser atherectomy system (AngioDynamics, Inc) showed a low rate of target-lesion revascularization (TLR) at 6-month follow-up in the investigational device exemption study. At present, real-world data are not available. In this study, we analyze major adverse events and 6-month outcomes with the Auryon laser system in treating infrainguinal arterial disease in all comers at a single center. METHODS: Consecutive patients treated with the Auryon laser between September 2017 and March 2021 were retrospectively reviewed from a single operator at a single center. Demographic, procedural, angiographic, and outcome data were extracted from patients' medical records. Descriptive and survival analyses were performed. The study's primary endpoint was the assessment of freedom from TLR at 6-month follow-up. Secondary endpoints included acute procedural results, distal embolization, bailout stenting (dissection type D or higher by National Heart, Lung, and Blood Institute [NHLBI] classification, and/or residual narrowing >30%), unplanned major amputation, death, or vascular complications. RESULTS: A total of 56 patients (65 procedures, 70 lesions) were enrolled. The mean age was 70.9 ± 10 years, 66.1% were males, 48.2% were diabetics, and 25% had limb ischemia. Of the 70 lesions, 31.4% had severe calcification, 38.6% were chronic total occlusions, and 48.6% were de novo disease (in-stent restenosis in 28.6%). The majority of treated vessels were femoropopliteal (88.6%) and 29.2% had 2 or more prior interventions. Mean stenosis was 91.3 ± 9.7% at baseline, 56.0 ± 17.3% post laser, and 11.4 ± 11.2% post final treatment. Lesion length was 117.1 ± 101.2 mm and treated length was 174.0 ± 116.0 mm. Bailout stenting occurred in 11/70 lesions (15.7%). There were no NHLBI type D dissections post laser and 1 type D dissection post laser + percutaneous transluminal angioplasty. A total of 47.1% received Lutonix drug-coated balloons (BD/Bard), 27.1% received In.Pact drug-coated balloons (Boston Scientific), and 1.4% received both. The probability of freedom from TLR per procedure was 95.6% at 6 months. CONCLUSION: In a real-world cohort of patients with complex disease, the Auryon laser had excellent freedom from TLR at 6 months, although these findings need to be replicated in a randomized trial.


Assuntos
Angioplastia com Balão , Doença Arterial Periférica , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Constrição Patológica/etiologia , Feminino , Artéria Femoral/cirurgia , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico , Doença Arterial Periférica/cirurgia , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Grau de Desobstrução Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA