Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 91
Filtrar
1.
J Clin Med ; 13(5)2024 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-38592229

RESUMO

Background: Digital technologies enable the accurate replication of occlusion, which is pivotal for stability in maximum intercuspation and dynamic occlusion. CAD softwares generates standardized occlusal morphologies requiring significant adjustments. The consideration of individual mandibular movements during restoration leads to better functional integration. This pilot study evaluates the efficacy of a novel, fully digital protocol for occlusal analysis recording in prosthodontics. Methods: Patients needing single or multiple metal-free restorations were included. Teeth underwent horizontal finish line preparation, while restorations on implants were either directly screwed or used multi-unit abutments. A digital impression (Trios 3 Intraoral Scanner) captured the mouth's elements. Dynamic occlusion was recorded via Patient Specific Motion (PSM). After the placement and functionalization of temporary restorations, subsequent scans included various elements, and CAD software (Dental system) was used for the restoration design. Restorations were milled in monolithic zirconia, pressed from CAD/CAM-milled wax, and sintered. Results: An evaluation of 52 restorations in 37 patients indicated high accuracy in restorations manufactured via the fully digital workflow. Monolithic zirconia was predominantly used. Subtractive (17.3%) and additive (7.7%) occlusal adjustments were mainly chairside. Conclusion: This study underscores the efficacy of meticulous verification measures and a centric contact system in reducing the need for clinical occlusal refinements in prosthetic restorations.

2.
Int J Implant Dent ; 10(1): 17, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551730

RESUMO

This case report provides a detailed description of a simple and fast bone regeneration procedure using a semi-customized three-dimensional ultra-fine titanium mesh. A 50-year-old male with a severe vertical and horizontal bone defect in the anterior mandible underwent implant treatment in a staged approach. The autologous bone was combined with a xenograft, and the mixture was grafted to augment the bone defect and covered with semi-customized ultra-fine titanium meshes, which were selected among its various types according to size and configuration of the bone defect, directly connected and immobilized on the tenting screws with minimal shaping. In a postoperative 6 months re-entry surgery, the performed titanium meshes were removed, implants were placed, and a bone core biopsy was obtained that demonstrated satisfactory new bone formation. Finally, two months later, the definitive prosthesis was installed. This semi-customized ultra-fine titanium mesh could help an implant clinician obtain more predictable results in the guided bone regeneration (GBR).


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Masculino , Humanos , Pessoa de Meia-Idade , Implantação Dentária Endóssea/métodos , Titânio , Aumento do Rebordo Alveolar/métodos , Regeneração Óssea
3.
Biomimetics (Basel) ; 8(6)2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37887592

RESUMO

This study evaluated the prophylactic effect of localized biomimetic minocycline and systemic amoxicillin on immediate implant placement at infected extraction sites. Twelve mongrels with six implants each were randomly assigned to five groups: uninfected negative control (Group N); infected with oral complex bacteria (Group P); infected and treated with amoxicillin one hour before implant placement (Group A); infected and treated with minocycline during implant placement (Group B); and infected and treated with amoxicillin one hour before implant placement and with minocycline during implant placement (Group C). Radiographic bone level, gingival index (GI), probing depth (PD), papillary bleeding index (PBI), and removal torque (RT) were recorded. There was no significant difference between Groups A, B, and C for bone loss. Group A showed the highest RT, the lowest PBI, and significantly lower GI and PD values than Group P. Group B exhibited significantly higher RT value than Group N and significantly smaller PD value than Group P at 6 w postoperatively. Localized minocycline could improve implant success by reducing bone loss and increasing RT and systemic amoxicillin could maintain the stability of the peri-implant soft tissue. However, combined use of these two antibiotics did not augment the prophylactic effect.

4.
J Korean Assoc Oral Maxillofac Surg ; 49(5): 297-303, 2023 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-37907346

RESUMO

A resorbable barrier membrane is commonly used for the repair of perforated sinus membranes during sinus lifting surgeries. However, repairing largescale perforations poses challenges for clinicians as the protection and isolation of graft material remain uncertain. With this technique, we aimed to prevent graft material loss and subsequent sinus-related complications using intra-sinus rigid fixation of the resorbable barrier membrane in cases with a large perforation of the sinus membrane.

5.
Int J Biomater ; 2023: 2745262, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37457392

RESUMO

This investigation aimed to compare the effectiveness of the OT Equator® (Rhein, Bologna, Italy) and the Locator attachment systems used to retain early loaded implant-retained overdentures. This study was designed as a multicenter randomised controlled trial of parallel groups. After implant placement, the patients were randomised to receive OT Equator® attachments in the test group or Locator attachments in the control group. The outcome measures were implant and prosthetic success and survival rates, any biological and technical complication, marginal bone loss, patients' satisfaction, and periodontal parameters. Overall, 42 patients were consecutively enrolled and treated. One implant was lost in the control group, while no implants were lost in the test group. No prostheses failed in both groups. Only a few complications were experienced in both groups. The main was represented by loss of retention of the attachments (retentive caps). The OT Equator® attachment showed statistically lower periodontal parameters. In conclusion, both attachment systems were suitable for overdenture implant retention.

6.
J Clin Med ; 12(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37297907

RESUMO

Restoring teeth with dental implants has become the gold standard in recent years, especially in the esthetic zone. However, limited amount of available bone as well as limited interdental space in the anterior zone may create problems for implant treatment. Narrow diameter implants (NDI) may be a treatment option to resolve the above-mentioned limitations and providing minimally invasive implant therapy without additional regenerative procedures. In this retrospective study, a comparison of clinical and radiographic outcomes between one-piece and two-piece titanium-made NDIs was done with the follow-up of two years after loading. Twenty-three NDI cases were analyzed, 11 in the one-piece implant group (group one) and 12 in the two-piece implant group (group two). The outcomes were implant and prosthetic failures, any complications occurred, peri-implant bone level changes, and as well as the Pink Esthetic score. No implant or prosthetic failures, as well as, no complications were reported at the two-year follow-up examination. At the same time the marginal bone loss was 0.23 ± 0.11 in the group one and 0.18 ± 0.12 in the group two. Difference was not statistically significant (p = 0.3339). The Pink Esthetic Score, recorded two years after definitive loading, was 12.6 ± 0.97 in the group one and 12.2 ± 0.92 in the group two, with no statistically significant difference between groups (p = 0.3554). With the limitations of the present study, including the small sample size and short follow-up, it is possible to conclude that either one and two-piece NDI can be successfully used to restore lateral incisors with comparable results within the two years of follow-up.

7.
Quintessence Int ; 54(5): 408-417, 2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-36917462

RESUMO

OBJECTIVE: The aim of this study was to evaluate the patient's morbidity and postsurgical complications after treatment of palatal donor sites after free gingival graft harvesting using leucocyte- and platelet-rich fibrin (L-PRF) membranes or a hemostatic agent with oxidized and regenerated cellulose. METHOD AND MATERIALS: Forty-two palatal donor sites after free gingival graft harvesting in 42 patients were randomly assigned to experimental (L-PRF membrane) or control procedure (hemostatic agent). The primary outcome was postoperative pain related to the wound located at the palatal area, and the secondary outcomes were postoperative discomfort, inability to chew, postoperative stress, surgical chair time, thickness of the palatal fibromucosa, and thickness of the free gingival graft. The patient-reported outcome measures were recorded after 1 week. RESULTS: After 1 week, a statistically significant difference was found between groups in terms of postoperative stress (P = .008). No statistically significant differences in terms of postoperative pain (P = .326), patient discomfort (P = .509), inability to chew (P = .936), or surgical chair time (P = .932) were recorded between the test and the control group. No statistically significant differences were recorded in terms of thickness of the palatal fibromucosa (P = .647) and thickness of the free gingival graft (P = .756) between groups. Postsurgical wound healing complications (ie, necrosis or infections) were not observed in both groups. CONCLUSION: Within their limitations, the present outcomes indicated that the application of L-PRF membrane at palatal donor sites after FGG harvesting did not produce significant advantages for the patients.


Assuntos
Hemostáticos , Fibrina Rica em Plaquetas , Humanos , Cicatrização , Dor Pós-Operatória/prevenção & controle , Medidas de Resultados Relatados pelo Paciente , Gengiva/transplante
8.
Materials (Basel) ; 15(17)2022 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-36079220

RESUMO

Aim: The aim of the present study was to investigate quantitative histological examination of bone reconstructed with non-resorbable high-density polytetrafluoroethylene membrane (d-PTFE), left intentionally exposed in post extraction sockets grafted with anorganic bone material, and removed after four weeks, versus extraction and guided bone regeneration (GBR), performed two months later. Materials and Methods: This study was designed as a multicenter randomized controlled trial of parallel-group design. Patients were selected and consecutively treated in three centers in Italy. Patients randomly received intentionally exposed non-resorbable d-PTFE membrane (group A), or guided bone regeneration (group B), to treat post-extractive alveolar bone defects with implant-supported restorations. Outcomes were: the implant failure, any mechanical and biological complications, patient satisfaction, and qualitative and histomorphometric evaluation of the collected bone samples. Results: Eighteen patients were consecutively enrolled in the trial. Of these, six out of 18 patients were male. All the included patients were treated according to the allocated interventions, and no drop out occurred. No implant failure and no complications were experienced, and all the patients were fully satisfied with the function and aesthetic of their implant-supported restoration, without difference between groups. Morphological analysis revealed no sign of tissue reaction, such as fibrosis or necrosis. Regenerated bone was well mineralized in both groups, but it seemed more mature in group B than in group A. Three samples showed a minimal number of lymphocytes. Several blood vessels of small size occupied the medullary spaces, where the tissue resulted in more maturity, indicating the activity of the tissue in progress. The histomorphometric evaluation showed no statistically significant differences in the tissue volume fractions between the two groups of patients. Conclusions: With the limitation of the present study, buccal plate reconstruction with an intentionally exposed non-resorbable membrane is an effective and easy procedure for regenerating a resorbed buccal bone plate, reducing the need for guided bone regeneration.

9.
Materials (Basel) ; 15(15)2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35955229

RESUMO

The aim of this study is to compare two low-temperature sintered anorganic bovine bone materials (ABBMs), Bio-Oss (Geistlich, Wolhusen, Switzerland) and A-Oss (Osstem, Seoul, Korea), for GBR in dehiscence defects. A single implant was placed simultaneously with GBR in the buccal or bucco-proximal osseous defect by double-layering of inner allograft and outer ABBM, covered by a preformed ultrafine titanium mesh and an absorbable collagen membrane. Grafted volume changes were evaluated by cone-beam computed tomography, taken preoperatively (T0), immediately after implant surgery (T1), after re-entry surgery (T2), and after delivery of the final restoration (T3). The density of the regenerated bone was assessed by measuring the probing depth on the buccal mid-center of the mesh after removing the mesh at T2. Postoperative sequelae were also recorded. Grafted volume shrinkage of 46.0% (0.78 ± 0.37 cc) and 40.8% (0.79 ± 0.33 cc) in the Bio-Oss group (8 patients) and A-Oss group (8 patients), respectively, was observed at T3 (p < 0.001). There were no significant differences in grafted volume changes according to time periods or bone density between the two groups. Despite postoperative mesh exposure (3 patients), premature removal of these exposed meshes and additional grafting was not necessary, and all implants were functional over the 1-year follow-up period. Both ABBMs with titanium meshes showed no significant difference in the quantity and density of the regenerated bone after GBR for peri-implant defects.

10.
J Craniofac Surg ; 33(7): 2228-2230, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-35184113

RESUMO

PURPOSE: Cysts and other intrabony lesions can grow asymptomatic until being diagnosed by occasionally done radiologic examination. Missing tooth and malposition of adjacent teeth should induce clinicians to perform X-Ray diagnostic. METHODS: A 37-year-old, male patient was admitted with a hopeless tooth 36, to be extracted and replaced with an implant. Clinical examination revealed also missing one of lower incisors and malposition of remaining lower incisors. Cone-beam computed tomography revealed horizontally impacted lower incisor surrounded by bone defect -15 × 20 × 8 mm with the bone thickness remaining only 3.5 mm in the narrowest area. The basis on strong masticatory muscles and low thickness of bone after surgical removal of tooth and lesion, prophylactic osteosynthesis was planned. To explain the surgery to the patient model of the mandible was 3D printed. RESULTS: Two treatment plans were presented to the patient: 1. custom plate production according to the bone defect and the shape of remaining bone and 2. choosing a standard plate and adjusting it on the 3D printed model. Costs of the material were 10 times higher in a custom solution. Plan 2 was then accepted. 1.2 mm straight plate was prebend on the model and sterilized. Lesion and impacted tooth were removed in local anesthesia. Prepared plates were fixed. CONCLUSIONS: In the presented case custom 3D printed osteosynthesis plate was about 10 times more expensive compared to the standard osteosynthesis plate used. 3D printing of bone model may be helpful for prebending chosen standard plate and planning the surgery.


Assuntos
Cistos Odontogênicos , Dente Impactado , Adulto , Tomografia Computadorizada de Feixe Cônico , Humanos , Incisivo , Masculino , Mandíbula/cirurgia , Dente Impactado/diagnóstico por imagem , Dente Impactado/cirurgia
11.
Materials (Basel) ; 15(2)2022 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-35057240

RESUMO

To evaluate the implant and prosthetic of two implants with different surfaces and neck design. Enrolled patients received bone level, 12° conical connection implants (Nobel Parallel, Nobel Biocare; NOBEL group) with anodized surface (TiUnite) and roughness of 1.35 µm, or transmucosal implant system (Prama, Sweden and Martina; PRAMA group) with convergent collar, ZIrTi surface, and roughness 1.4-1.7 µm. Both implants were made of pure grade IV titanium, with similar diameter and length, chosen according to the dentistry department availability and patient's request. After early prosthesis delivery, patients were filled for at least one year. Outcome measures were: implant and prosthetic survival and success rates, physiological marginal bone remodeling, periodontal parameters and pink esthetic score (PES). Results: Fifteen patients were allocated and treated in each group. At the one-year follow-up, three patients dropped out, one in the NOBEL group and two in the PRAMA group. During the entire time of investigation, all implants survived and the prostheses were successful. No statistically significant differences were found in term of marginal bone loss, periodontal parameters, and aesthetics (p > 0.05). Conclusion: With the limitations of the present study, both implant systems showed successful clinical results. Finally, many other clinical and surgical variables may influenced marginal bone levels, implant survival, and periodontal parameters. More homogenous clinical trials with larger samples are needed to confirm these preliminary conclusions.

12.
Eur J Dent ; 16(4): 787-795, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34991163

RESUMO

OBJECTIVE: The purpose of the present prospective, case-series study was to report implant survival rate and marginal bone remodeling expected 5 years after loading using dental implants placed in daily practice. MATERIALS AND METHODS: This research was designed as an open-cohort, prospective, case-series evaluation. Any partially or completely edentulous patient, scheduled to receive at least one bone level implant, was considered eligible for this study. Primary outcome measurements were: implant and prosthetic cumulative survival rate and any complications experienced up to the 5-year follow-up. Secondary outcome measures were: thickness of gingival biotype, implant insertion torque, implant stability quotient, and marginal bone loss (MBL). RESULTS: Ninety consecutive patients (34 males and 56 females, aged between 24 and 81 years old [mean: 53.2 ± 15.4]) with 243 inserted implants were followed for at least 5 years after loading (mean: 65.4 ± 3.1 months; range from 60 to 72). At the 1-year follow-up, no drop-outs were recorded, but 17 patients (18.9%) with 18 restorations (12.6%) delivered on 34 implants (14%) were lost at the 5-year examination. At the 5-year follow-up examination, six implants lost osseointegration (97.5%). In the same period, four prostheses failed (97.2%). Five complications were reported in five different patients (prosthetic success rate was 96.5%, at patient level). Five years after loading, the mean MBL was 0.41 ± 0.30 mm. The difference from the 1-year data was 0.04 ± 0.19 mm. A statistically significant higher MBL was found for smokers, and patients with thin gingival biotype. The mean implant insertion torque was 42.9 ± 4.8 Ncm (range from 15 to 45 Ncm). Two-hundred and three implants (83.5%) were inserted with an insertion torque ≥35 and ≤45 Ncm. CONCLUSIONS: High implant survival and success rate could be expected with stable marginal bone remodeling up to 5 years after loading. Smoking and thin tissue biotype were the most important variabilities associated with higher MBL. Further research studies are needed to confirm these results.

13.
J Dent ; 115: 103852, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34656660

RESUMO

INTRODUCTION: The aim of the present systematic review was to evaluate whether there were any differences in the three-dimensional accuracy and the implant survival rate of implants placed using computer-assisted planning and surgical templates with or without metallic sleeves. SOURCES: This systematic review was written according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and registered to the PROSPERO (International prospective register of systematic reviews) database. STUDY SELECTION: PICOS (population, intervention, control, outcomes, and studies) question was assessed, too. Search strategy encompassed the online (MedLine) literature from 1990 up to December 2020 published in English, and evaluating the accuracy of surgical templates with and without metallic sleeves in partial or complete patients. Only in vivo, randomized controlled trial and observational studies were included. Quality assessment of selected full text articles was performed according to the CONSORT (CONsolidated Standards of Reporting Trials) and STROBE (Strengthening the Reporting of Observational studies in Epidemiology) statement guidelines, respectively. For data analysis, the three-dimensional accuracy and the overall implant survival rate was calculated and compared between implants placed using surgical templates with or without metallic sleeves. DATA: A total of 12 articles fulfilled the inclusion/exclusion criteria. Data from 264 patients with 614 implants were subjected to quality assessment (templates with metallic sleeves: 279 implants and 136 patients; templates without metallic sleeves: 335 implants and 128 patients). In all the three deviation parameters (angular, vertical, and horizontal), the differences in average accuracy were noticed (angular 2.33° ± 2.01° versus 3.09° ± 1.65°, vertical: 0.62 ± 0.36 [mm] versus 0.95 ± 0.42 [mm]; and horizontal: 0.62 ± 0.41 [mm] and 1.11 ± 0.57 [mm]. No differences was found regarding overall implant survival rate (0.4891). CONCLUSIONS: With the limitations of the present study, the surgical templates without metallic sleeves demonstrated high level of accuracy in all the three-dimensional measurements, when used to rehabilitate partially edentulous patients. Further randomized controlled trials, reporting according to the CONSORT guidelines are needed to confirm that the differences in accuracy depended on the type of used templates.


Assuntos
Implantes Dentários , Boca Edêntula , Implantação Dentária Endóssea/métodos , Humanos
14.
Eur J Dent ; 15(2): 290-294, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33622005

RESUMO

OBJECTIVE: Preliminary data on survival and success rates of immediately loaded, maxillary, screw-retained, implant-supported, fixed restorations delivered on narrow and low-profile OT Equator abutments (OT Bridge, Rhein'83) were evaluated. MATERIALS AND METHODS: This retrospective study evaluated data collected from patients rehabilitated with OT Bridge prosthetic concept between November 2017 and February 2019 in six different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. RESULTS: A total of 76 implants were inserted in 14 patients. Patients were followed for a mean period of 15.8 months (range = 12-24). All the patients receive OT Equator (Rhein'83) as intermediate abutments. One year after loading, one implant failed (1.3%). None of the prosthesis failed. One prosthetic complication was experienced in one patient. Three out of 76 implants were connected to the prosthetic framework using only the Seeger system, without screw. Difference in OHIP values was statistically significant (71.9 ± 8.5; p = 0.000). One year after loading, MBL was 0.21 ± 0.11 mm and p-value was 0.000. One year after loading, 8.7% of the examined implant sites present positive bleeding on probing, while 6.4% of the implant sites presented plaque. CONCLUSION: The OT Equator abutments (Rhein'83) showed successful results when used to support maxillary fixed dental prosthesis delivered on four to six implants. High implant and prosthetic survival rates, very low complications, high patient satisfaction, and good biological parameters, including only 0.2 mm of bone remodeling were experienced one year after function. Further studies are needed to confirm these preliminary results.

15.
Clin Implant Dent Relat Res ; 23(3): 380-387, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33611832

RESUMO

BACKGROUND: Surgical templates are classified as noncritical devices, and they do not need to be sterile. AIM: Primary aim of this study was to assess the microbiological burden present on the surgical templates without metallic sleeves after disinfection. Furthermore, to evaluate trueness after disinfection and steam sterilization at 121°C/15 min, and over a 8-week storage period. Finally, to assess their accuracy after in vitro implant placement simulation. MATERIALS AND METHODS: Forty surgical templates were printed and divided in five groups of eight templates each. Groups A to C were disinfected with 0.5% Chlorhexidine Gluconate and 70% ethyl alcohol base solution for 15 min. Templates in the group D were steam sterilized at 121°C for 15 min, while, the templates in the group E were used as control. Implant simulation was performed in the group A. Outcome measures were determination of bioburden, trueness assessment using GOM Inspect Professional software, and accuracy evaluated thought the mean angular deviation of simulated implants. RESULTS: Total microbic charge measured as colony forming units (CFU) for sample, was 24.40 in the control group (group E; n = 8), and <4.40 in the test group (group C; n = 8), with a reduction of 84%. Colored representation from GOM inspection showed no differences after disinfection and implant simulation, disinfection alone, and steam sterilization, compared to the control group. A very small difference in the surface and volume dimensions was reported 1 month after templates fabrication. The mean roundness tolerances of the tested templates improved of 0.96 ± 0.56° (95% CI 0.57-1.35). CONCLUSION: Surgical templates without metallic sleeves can be safely used after disinfection, demonstrating high level of accuracy, even when the surgical procedures should be postponed within a couple of weeks. Further in vivo study are needed to confirm these preliminary results.


Assuntos
Desenho Assistido por Computador , Cirurgia Assistida por Computador , Desinfecção , Software
16.
J Funct Biomater ; 12(1)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557297

RESUMO

The aim of this retrospective study was to clinically evaluate the five-year outcomes of implants placed following a combined approach to the sinus, consisting of sequential drills and osteotomes. Medical records of patients with implants placed in combination with crestal sinus lift using sequential drills and osteotomes, with a residual alveolar bone crest between 4 to 8 mm, and a follow-up of at least five years after final loading, were evaluated. Outcomes were implant and prosthetic survival and success rates, any complication, and marginal bone loss. Data from 96 patients (53 women and 43 men; mean age 54.7 years; range 23-79 years) were collected. A total of 105 single implants were analyzed. After five years of function, two implants were lost and two prostheses failed. No major biological or prosthetic complications occurred. At the five-year examination, the marginal bone loss was 1.24 ± 0.28 mm. Within the limitations of this retrospective study it can be concluded that implants placed following a combined approach to the sinus consisting of sequential drills and osteotomes seem to be a viable option for the treatment of posterior atrophic edentulous maxilla.

17.
Materials (Basel) ; 14(2)2021 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-33466584

RESUMO

A dental implant is a medical device used to functionally and aesthetically rehabilitate the lack of one or more teeth, allowing the support of a prosthetic substitute through direct bone support [...].

18.
Materials (Basel) ; 15(1)2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-35009400

RESUMO

The purpose of the present study was to evaluate the histological and histomorphometric characteristics of post-extraction sites grafted with decellularized bovine compact bone from bovine femur, mixed and unmixed with leukocyte- and platelet-rich fibrin after four months of healing. This study was designed as a randomized controlled trial of parallel groups. Patients in need of a single, implant-supported restoration to replace a hopeless tooth were recruited for tooth extraction and implant placement four months after socket preservation procedure. After tooth extraction, patients were randomly allocated to receive decellularized bovine compact bone from bovine femur, mixed and unmixed with leukocyte- and platelet-rich fibrin. After four months of healing, tapered implants were inserted with an insertion torque between 35 and 45 Ncm. Two months later, implants were loaded with screw-retained definitive crowns. Outcome measures were implant (ISR) and prosthesis (PSR) survival rates, complications, histological and histomorphometric analyses, radiographic marginal bone-level changes, and patients' satisfaction. Clinical data were collected up to one year after tooth extraction and socket preservation procedures. Thirty patients were consecutively enrolled in the trial (15 in each group). Unfortunately, due to the COVID-19 pandemic, bone samples were collected only in 19 patients. Two implants failed before definitive prosthesis delivery (ISR 93.3%). No prosthesis failed (PSR 100%). Three complications were experienced in the control group. The mean bone percentage was 40.64 ± 18.76 in the test group and 33.40 ± 22.38 in the control group. The difference was not statistically significant (p = 0.4846). The mean soft tissue percentage was 32.55 ± 19.45 in the test group and 55.23 ± 17.64 in the control group. The difference was statistically significant (p = 0.0235). The mean residual graft was 24.59 ± 18.39 in the test group and 11.37 ± 12.12 in the control group. The difference was not statistically significant (p = 0.0992). Mean marginal bone loss, as well as patient satisfaction, showed no differences between groups. With the limitations of the present study, socket preservation with L-PRF mixed with decellularized bovine compact bone demonstrated favorable results, comparing with decellularized bovine compact bone from bovine femur alone. Further studies with larger sample size and longer follow-up are needed to confirm these preliminary results.

19.
Eur J Dent ; 15(1): 1-7, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33242915

RESUMO

OBJECTIVE: To compare early implant failure and implant stability of one-stage Hiossen ET III implants with its new hydrophilic (NH) surface, compared with Hiossen ET III implants with the sandblasted and acid-etched (SA) surface at 1-year follow-up. MATERIALS AND METHODS: This study was designed as a split-mouth, multicenter randomized controlled trial aimed to compare SA surface implants (SA group) and NH surface, (NH group). Outcomes were implant and prosthetic survival rates, complications, the insertion torque at implant placement, and implant stability quotient (ISQ) values. RESULTS: Twenty-nine patients (mean age 59.9 ± 11.3 years) were treated and followed up to 1 year after loading. No patient dropped out. Fifty-eight implants (29 SA group and 29 NH group) were placed. No implants or prostheses failed and no complications were experienced during follow-up. The mean insertion torque was 40.5 ± 3.23 (38.17-41.83) Ncm in the SA group and 40.48 ± 3.49 (38.02-41.98) Ncm in the NH group (p = 0.981). There was a statistically significant difference at the second week (T2) with higher values in the NH group (p = 0.041). Similar results were found in the maxilla (p = 0.045), but not in the mandible (p = 0.362). A positive correlation was found between initial insertion torque and ISQ with higher value in the NH group (0.73 vs. 0.66). CONCLUSIONS: NH implants are a viable alternative to SA surface, as they seem to avoid the ISQ drop during the bone remodeling phase.

20.
Eur J Dent ; 14(S 01): S171-S176, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33321548

RESUMO

The purpose of the present narrative review was to evaluate and discuss the actual available information regarding coronavirus disease 2019 and dental practice, and to share recommendations with the intent to help dentists in providing a safe and healthful workplace during pandemic. A step-by-step workflow is presented including prevention and measures to reduce risk for cross infections before, during, and after the dental treatments. Individualization of different risk-level zones and the establishment of a team-based chain control is also presented. The present manuscript may offer deeper knowledge and discussion regarding recommended procedures aimed to reduce risk for dental health care workers contamination and cross infections. Within these, infection prevention in dental settings, respect of general rules, containment measures, proper use of the personal protective equipments (PPE), and well-organized chain control of all the staff, with definition of risk zones and specific responsibility could be an adjunctive but important step to control the spread of the disease.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...