Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-32563957

RESUMO

A new size-exclusion high-performance liquid chromatographic (SE-HPLC) method for the simultaneous analysis of filgrastim and pegfilgrastim aggregates was developed and validated. A cross-linked agarose and dextran column was used at ambient temperature and an alkaline sodium phosphate buffer as mobile phase eliminated non-ideal interactions with the stationary phase. The robustness of the method was assessed by varying injection volumes, flow rates and sample vehicles. Other reliability assessments include calibration curve, intra and inter-day precision and accuracy, repeatability of retention times, application to real in-process production samples and column lifetime. The method exhibited linearity over the concentration of 0.02-4 mg/ml range for filgrastim and pegfilgrastim monomer with a correlation coefficient of greater than 0.999. The lower limit of quantification was 0.02 mg/ml and the limit of detection was 0.005 mg/ml. This SE-HPLC technique has been successfully used for several years and more than 10,000 samples.


Assuntos
Cromatografia em Gel/métodos , Filgrastim/análise , Polietilenoglicóis/análise , Cromatografia Líquida de Alta Pressão , Filgrastim/química , Filgrastim/isolamento & purificação , Concentração de Íons de Hidrogênio , Limite de Detecção , Modelos Lineares , Concentração Osmolar , Polietilenoglicóis/química , Polietilenoglicóis/isolamento & purificação , Reprodutibilidade dos Testes
2.
Biologicals ; 46: 153-158, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28237422

RESUMO

A size-exclusion high-performance liquid chromatographic method using a methacrylate-based column was developed, validated and implemented for the determination of pegfilgrastim aggregates. The samples were directly injected into a TSKgel G4000PWXL column (7.5 mm × 300 mm, 10 µm, <500 A°) with a mobile phase of 100 mM phosphate, pH 2.5. Detection was made at 215 nm and analyses were run at a flow-rate of 0.6 ml/min at 10 °C. Vortex-mixing of samples produced oligomers, however, very high molecular weight aggregates were formed at high temperatures. The method exhibited linearity over the concentration range of 0.1-14 mg/ml for pegfilgrastim monomer and high molecular weight aggregates with a correlation coefficient of greater than 0.99. The method was specific and sensitive, with a lower quantification limit of 0.1 mg/ml and a detection limit of 0.02 mg/ml. Over 1200 samples were analyzed by the present method without significant change in the column performance.


Assuntos
Cromatografia em Gel/métodos , Cromatografia Líquida de Alta Pressão/métodos , Fator Estimulador de Colônias de Granulócitos/análise , Metacrilatos/química , Cromatografia em Gel/instrumentação , Cromatografia Líquida de Alta Pressão/instrumentação , Filgrastim , Fator Estimulador de Colônias de Granulócitos/química , Peso Molecular , Polietilenoglicóis , Proteínas Recombinantes/análise , Proteínas Recombinantes/química , Reprodutibilidade dos Testes , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA