Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biosensors (Basel) ; 14(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38667189

RESUMO

L-Lactate is an important bioanalyte in the food industry, biotechnology, and human healthcare. In this work, we report the development of a new L-lactate electrochemical biosensor based on the use of multiwalled carbon nanotubes non-covalently functionalized with avidin (MWCNT-Av) deposited at glassy carbon electrodes (GCEs) as anchoring sites for the bioaffinity-based immobilization of a new recombinant biotinylated lactate oxidase (bLOx) produced in Escherichia coli through in vivo biotinylation. The specific binding of MWCNT-Av to bLOx was characterized by amperometry, surface plasmon resonance (SPR), and electrochemical impedance spectroscopy (EIS). The amperometric detection of L-lactate was performed at -0.100 V, with a linear range between 100 and 700 µM, a detection limit of 33 µM, and a quantification limit of 100 µM. The proposed biosensor (GCE/MWCNT-Av/bLOx) showed a reproducibility of 6.0% and it was successfully used for determining L-lactate in food and enriched serum samples.


Assuntos
Avidina , Técnicas Biossensoriais , Ácido Láctico , Oxigenases de Função Mista , Nanotubos de Carbono , Nanotubos de Carbono/química , Oxigenases de Função Mista/química , Avidina/química , Técnicas Eletroquímicas , Ressonância de Plasmônio de Superfície , Enzimas Imobilizadas/química , Escherichia coli , Biotinilação , Eletrodos , Espectroscopia Dielétrica , Limite de Detecção
2.
Talanta ; 270: 125520, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38147722

RESUMO

We report a nanohybrid material obtained by non-covalent functionalization of multi-walled carbon nanotubes (MWCNTs) with the new ligand (((1E,1'E)-(naphthalene-2,3-diylbis(azaneylylidene))bis(methaneylylidenedene)) bis(4-hydroxy-3,1-phenylene))diboronic acid (SB-dBA), rationally designed to mimic some recognition properties of biomolecules like concanavalin A, for the development of electrochemical biosensors based on the use of glycobiomolecules as biorecognition element. We present, as a proof-of-concept, a hydrogen peroxide biosensor obtained by anchoring horseradish peroxidase (HRP) at a glassy carbon electrode (GCE) modified with the nanohybrid prepared by sonication of 2.0 mg mL-1 MWCNTs and 0.50 mg mL-1 SB-dBA in N,N-dimethyl formamide (DMF) for 30 min. The hydrogen peroxide biosensing was performed at -0.050 V in the presence of 5.0 × 10-4 M hydroquinone. The analytical characteristics of the resulting biosensor are the following: linear range between 0.175 µM and 6.12 µM, detection limit of 58 nM, and reproducibility of 2.0 % using the same nanohybrid (6 biosensors), and 9.0 % using three different nanohybrids. The sensor was successfully used to quantify hydrogen peroxide in enriched milk and human blood serum samples and in a commercial disinfector.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Humanos , Nanotubos de Carbono/química , Ácidos Borônicos , Peróxido de Hidrogênio/química , Bases de Schiff , Reprodutibilidade dos Testes , Técnicas Biossensoriais/métodos , Peroxidase do Rábano Silvestre/química , Eletrodos , Técnicas Eletroquímicas
3.
J Pharm Biomed Anal ; 232: 115370, 2023 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-37163830

RESUMO

The COVID-19 pandemic had devastating effects throughout the world, producing a severe crisis in the health systems and in the economy of a long list of countries, even developed ones. Therefore, highly sensitive and selective analytical bioplatforms that allow the descentralized and fast detection of the severe acute respiratory síndrome coronavirus 2 (SARS-CoV-2), are extremely necessary. Since 2020, several reviews have been published, most of them focused on the different strategies to detect the SARS-CoV-2, either from RNA, viral proteins or host antibodies produced due to the presence of the virus. In this review, the most relevant biosensors for the detection of SARS-CoV-2 RNA are particularly addressed, with special emphasis on the discussion of the biorecognition layers and the different schemes for transducing the hybridization event.


Assuntos
Técnicas Biossensoriais , COVID-19 , Ácidos Nucleicos , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , RNA Viral/genética , Pandemias
4.
Mikrochim Acta ; 190(2): 73, 2023 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-36695940

RESUMO

An innovative strategy is proposed to simultaneously exfoliate multi-walled carbon nanotubes (MWCNTs) and generate MWCNTs with immunoaffinity properties. This strategy was based on the non-covalent functionalization of MWCNTs with human immunoglobulin G (IgG) by sonicating 2.5 mg mL-1 MWCNTs in 2.0 mg mL-1 IgG for 15 min with sonicator bath. Impedimetric experiments performed at glassy carbon electrodes (GCE) modified with the resulting MWCNT-IgG nanohybrid in the presence of anti-human immunoglobulin G antibody (Anti-IgG) demonstrated that the immunoglobulin retains their biorecognition properties even after the treatment during the MWCNT functionalization. We proposed, as proof-of-concept, two model electrochemical sensors, a voltammetric one for uric acid quantification by taking advantages of the exfoliated MWCNTs electroactivity (linear range, 5.0 × 10-7 M - 5.0 × 10-6 M; detection limit, 165 nM) and an impedimetric immunosensor for the detection of Anti-IgG through the use of the bioaffinity properties of the IgG present in the nanohybrid (linear range, 5-50 µg mL-1; detection limit, 2 µg mL-1).


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Humanos , Técnicas Biossensoriais/métodos , Nanotubos de Carbono/química , Imunoensaio , Imunoglobulina G , Eletrodos
5.
Biosens Bioelectron X ; 12: 100222, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36118917

RESUMO

We report two novel genosensors for the quantification of SARS-CoV-2 nucleic acid using glassy carbon electrodes modified with a biocapture nanoplatform made of multi-walled carbon nanotubes (MWCNTs) non-covalently functionalized with avidin (Av) as a support of the biotinylated-DNA probes. One of the genosensors was based on impedimetric transduction offering a non-labelled and non-amplified detection of SARS-CoV-2 nucleic acid through the increment of [Fe(CN)6]3-/4- charge transfer resistance. This biosensor presented an excellent analytical performance, with a linear range of 1.0 × 10-18 M - 1.0 × 10-11 M, a sensitivity of (5.8 ± 0.6) x 102 Ω M-1 (r2 = 0.994), detection and quantification limits of 0.33 aM and 1.0 aM, respectively; and reproducibilities of 5.4% for 1.0 × 10-15 M target using the same MWCNTs-Av-bDNAp nanoplatform, and 6.9% for 1.0 × 10-15 M target using 3 different nanoplatforms. The other genosensor was based on a sandwich hybridization scheme and amperometric transduction using the streptavidin(Strep)-biotinylated horseradish peroxidase (bHRP)/hydrogen peroxide/hydroquinone (HQ) system. This genosensor allowed an extremely sensitive quantification of the SARS-CoV-2 nucleic acid, with a linear range of 1.0 × 10-20 M - 1.0 × 10-17 M, detection limit at zM level, and a reproducibility of 11% for genosensors prepared with the same MWCNTs-Av-bDNAp1 nanoplatform. As a proof-of-concept, and considering the extremely high sensitivity, the genosensor was challenged with highly diluted samples obtained from SARS-CoV-2 RNA PCR amplification.

6.
Analyst ; 147(10): 2130-2140, 2022 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-35421882

RESUMO

This work presents for the first time the systematic preparation of a novel carbon nanotube-MCM-41 hybrid employing the mesoporous material MCM-41 as a successful dispersant for multiwall carbon nanotubes (MWCNTs). Relevant dispersion variables such as the amount of MWCNTs, MCM-41 concentration, and sonication time were optimized through a central composite design (CDD)/response surface methodology (RSM). Several solvents were evaluated and N,N-dimethylformamide (DMF) was selected because it allowed reaching stable dispersions with very good electrochemical response. The electrochemical performance of glassy carbon electrodes (GCE) modified with different hybrids was evaluated by cyclic voltammetry (CV) using ascorbic acid (AA) as redox marker, while their surface morphology was characterized by SEM microscopy. The optimal MWCNT-MCM-41 dispersion condition was 0.75 mg mL-1 MWCNTs, 0.25 mg mL-1 MCM-41, and 30 min sonication. Both, electrochemical results and SEM images correlate with a percolation behavior from MWCNT-MCM-41 hybrid. Electrooxidation of AA at GCE modified with the optimal hybrid occurred under diffusion control and exhibited an enhanced current response (65 µA) and a lower overvoltage (-0.005 V) compared to bare GCE (ip = 22 µA, Ep = 0.255 V). The amperometric response of AA at GCE/MWCNT-MCM-41 exhibited remarkable figures of merit, including an ultralow detection limit (1.5 nM), high sensitivity (45.4 × 103 µA M-1), excellent short- and long-term stability, and very good anti-interference ability for AA detection. The analytical applicability of the developed electrochemical sensor was evaluated by sensing AA in several real samples, showing excellent correlation with the values reported by manufacturers in both pharmaceutical and food samples.


Assuntos
Nanotubos de Carbono , Ácido Ascórbico/química , Técnicas Eletroquímicas/métodos , Eletrodos , Nanotubos de Carbono/química , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...