Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Prosthet Dent ; 107(2): 80-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22304741

RESUMO

STATEMENT OF PROBLEM: Compromised angulation of implants may result in abutment preparation that is less than ideal. Compromised abutment preparation may affect the retention of implant-retained crowns. PURPOSE: The purpose of this study was to investigate the effect of 5 implant abutment designs on the retention of cement-retained crowns by varying the number and position of the axial walls. MATERIAL AND METHODS: Five prefabricated abutments were attached to an implant analog and embedded in an acrylic resin block. The first abutment was left intact without modification. Axial walls were partially removed from the remaining abutments to produce abutments with 3 walls, 2 adjacent walls, 2 opposing walls, and 1 wall. Five crowns were made for each group. The screw access channel for the first abutment was completely filled with composite resin and the rest were partially filled. The retentive surface area of each abutment was calculated. Crowns were cemented with zinc phosphate cement. Tensile force was applied to separate the castings from the abutments. Peak load to dislodgment was recorded. A 1-way ANOVA was used to test for a significant difference followed by the Tukey Honestly Significant Difference test (α=.05). RESULTS: The abutment with 2 opposing axial walls had significantly higher retention than that of all other groups (F=149.9, df =24, P<.001). The abutment with 3 walls exhibited the second highest retention and was significantly greater than abutments with 2 adjacent walls, 1, and 4 walls. Abutments with 2 adjacent walls and 1 wall were not significantly different from each other. The unmodified abutment with 4 walls exhibited the lowest retention despite having a large retentive surface area. CONCLUSIONS: The retention of cemented crowns on implant abutments is influenced by the number and position of axial walls.


Assuntos
Cimentação/métodos , Coroas , Projeto do Implante Dentário-Pivô , Implantes Dentários , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Óxido de Alumínio/química , Ligas de Cromo/química , Resinas Compostas/química , Corrosão Dentária/métodos , Adaptação Marginal Dentária , Materiais Dentários/química , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Estresse Mecânico , Propriedades de Superfície , Cimento de Fosfato de Zinco/química
2.
J Prosthet Dent ; 101(4): 279-82, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19328281

RESUMO

This article describes a technique for making a definitive impression for highly displaceable residual ridges. The technique is especially applicable for mandibular edentulous ridges. The choice of the impression materials, as well as the design of the impression tray, focuses on preventing distortion of the displaceable residual ridges during impression making. Using an impression tray with an opening, modeling plastic impression compound and impression wax are used to accurately capture the shape of the residual ridge and place pressure onto denture load-bearing areas. Low-viscosity vinyl polysiloxane impression material is then used over the window opening to capture the surface details of the residual ridge without distorting the displaceable tissues. The use of this technique helps in maintaining the contour and capturing the detail of the tissues, as well as in accurately determining the extent of the muccobuccal denture extensions.


Assuntos
Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica/instrumentação , Arcada Edêntula/reabilitação , Mandíbula , Modelos Dentários , Perda do Osso Alveolar/patologia , Planejamento de Dentadura/métodos , Humanos , Mandíbula/patologia , Polivinil/química , Siloxanas/química , Ceras/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA