Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 972-981, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38606477

RESUMO

BACKGROUND: Ethylene diamine tetra-acetic acid (EDTA) is a chelating agent used to dissolve calcium deposits but evidence in decalcifying atherosclerotic lesions is limited. AIMS: We assessed the feasibility and efficacy of EDTA delivered via porous balloon to target calcified lesions in cadaveric below-the-knee (BTK) arteries. METHODS: Using porcine carotid arteries, EDTA concentration was measured in the arterial wall and outside the artery at the 0-, 0.5-, 4-, and 24-h circulation after the injection through a porous balloon. In cadaver BTK samples, the proximal and distal anterior tibial artery (ATA) and distal posterior tibial artery (PTA) were studied. EDTA-2Na/H2O or EDTA-3Na/H2O were administrated using a porous balloon, then circulated for 6 h for EDTA-3Na/H2O and 24 h for EDTA-2Na/H2O and EDTA-3Na/H2O. Micro-CT imaging of the artery segments before and after the circulation and cross-sectional analyses were performed to evaluate calcium burden. RESULTS: In the porcine carotid study, EDTA was delivered through a porous balloon present in the arterial wall and was retained there for 24 h. In BTK arteries, cross-sectional analyses of micro-CT revealed a significant decrease in the calcium area in the distal ATA segment under 24-h circulation with EDTA-2Na/H2O and in the distal ATA segment under 24-h circulation with EDTA-3Na/H2O. The proximal ATA segment under 6-h circulation with EDTA-3Na/H2O showed no significant change in any parameters of calcium CONCLUSION: EDTA-3Na/H2O or EDTA-2Na/H2O with longer circulation times resulted in greater calcium reduction in atherosclerotic lesion. EDTA may have a potential therapeutic option for the treatment of atherosclerotic calcified lesions.


Assuntos
Angioplastia com Balão , Ácido Edético , Estudos de Viabilidade , Calcificação Vascular , Animais , Ácido Edético/farmacologia , Angioplastia com Balão/instrumentação , Porosidade , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia , Cadáver , Artérias da Tíbia/diagnóstico por imagem , Quelantes de Cálcio/farmacologia , Fatores de Tempo , Microtomografia por Raio-X , Humanos , Dispositivos de Acesso Vascular , Desenho de Equipamento , Sus scrofa , Doença Arterial Periférica/terapia , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/metabolismo , Placa Aterosclerótica , Suínos
2.
JACC Case Rep ; 29(3): 102196, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38361566

RESUMO

Spontaneous coronary artery dissection occurs predominantly in women and is associated with fibromuscular dysplasia. We illustrate a rare case of sudden coronary death as a result of cardiac rupture from spontaneous coronary artery dissection in a 54-year-old man without fibromuscular dysplasia. Cardiac rupture has been previously reported in 6 cases, mostly in women.

3.
Arterioscler Thromb Vasc Biol ; 43(12): 2333-2347, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37881937

RESUMO

BACKGROUND: Studies in humans and mice using the expression of an X-linked gene or lineage tracing, respectively, have suggested that clones of smooth muscle cells (SMCs) exist in human atherosclerotic lesions but are limited by either spatial resolution or translatability of the model. METHODS: Phenotypic clonality can be detected by X-chromosome inactivation patterns. We investigated whether clones of SMCs exist in unstable human atheroma using RNA in situ hybridization (BaseScope) to identify a naturally occurring 24-nucleotide deletion in the 3'UTR of the X-linked BGN (biglycan) gene, a proteoglycan highly expressed by SMCs. BGN-specific BaseScope probes were designed to target the wild-type or deletion mRNA. Three different coronary artery plaque types (erosion, rupture, and adaptive intimal thickening) were selected from heterozygous females for the deletion BGN. Hybridization of target RNA-specific probes was used to visualize the spatial distribution of mutants. A clonality index was calculated from the percentage of each probe in each region of interest. Spatial transcriptomics were used to identify differentially expressed transcripts within clonal and nonclonal regions. RESULTS: Less than one-half of regions of interest in the intimal plaque were considered clonal with the mean percent regions of interest with clonality higher in the intimal plaque than in the media. This was consistent for all plaque types. The relationship of the dominant clone in the intimal plaque and media showed significant concordance. In comparison with the nonclonal lesions, the regions with SMC clonality had lower expression of genes encoding cell growth suppressors such as CD74, SERF-2 (small EDRK-rich factor 2), CTSB (cathepsin B), and HLA-DPA1 (major histocompatibility complex, class II, DP alpha 1), among others. CONCLUSIONS: Our novel approach to examine clonality suggests atherosclerosis is primarily a disease of polyclonally and to a lesser extent clonally expanded SMCs and may have implications for the development of antiatherosclerotic therapies.


Assuntos
Aterosclerose , Placa Aterosclerótica , Feminino , Humanos , Camundongos , Animais , Músculo Liso Vascular/metabolismo , Aterosclerose/patologia , Placa Aterosclerótica/patologia , Células Clonais/patologia , Proliferação de Células , Miócitos de Músculo Liso/metabolismo , RNA
5.
Cardiovasc Interv Ther ; 38(4): 395-405, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37184629

RESUMO

We developed the smallest diameter guide-extension catheter (GUIDE PLUS® 5Fr) to enable a new technique, the guide-extension proximal locking method (GP-Lock), and assessed its efficacy in the present experimental and clinical study. Sufficient guide catheter backup is sometimes crucial for PCI. We developed the KIWAMI-Lock direct anchoring method to obtain the strongest backup force by locking a Kiwami® 4Fr child catheter (Terumo Corp. Tokyo, Japan) directly to the coronary artery by ballooning from outside the child catheter. However, this method is complicated due to the requirement for a child catheter. We compared the backup power of the GP-Lock method and other conventional methods in an experimental study and compared the procedural outcomes of 17 cases treated using the initial GP-Lock method with 17 cases using the recent KIWAMI-Lock method before GP-Lock. The GP-Lock method had the highest backup force among the methods examined (GP-Lock: 293.7 ± 10.2 g force (gf), KIWAMI-Lock: 270.4 ± 12.9 gf, side branch balloon anchoring technique: 182.7 ± 8.1 gf, respectively, P < 0.0001). The preparation time was significantly shorter for the GP-Lock group than the KIWAMI-Lock group (5.0 [4.0, 5.0] min vs. 11.0 [8.0, 13.0] min, respectively, P < 0.001). The GP-Lock method makes it possible to easily obtain the strongest backup force, which can overcome situations where devices cannot pass through, especially in complex PCI procedures.


Assuntos
Intervenção Coronária Percutânea , Criança , Humanos , Intervenção Coronária Percutânea/métodos , Desenho de Equipamento , Catéteres , Cateterismo , Padrões de Referência , Resultado do Tratamento , Angiografia Coronária
6.
Heart Vessels ; 38(2): 171-176, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35904577

RESUMO

Lipoprotein(a) [Lp(a)] is a risk factor for peripheral artery disease (PAD). However, the relationship between Lp(a) levels and clinical events after endovascular therapy (EVT) for the femoropopliteal artery in PAD patients remains unclear. Thus, this study aimed to assess the impact of Lp(a) levels on primary patency after EVT for de novo femoropopliteal lesions in PAD patients. A retrospective analysis was conducted on 109 patients who underwent EVT for de novo femoropopliteal lesions, and Lp(a) levels were measured before EVT between June 2016 and December 2019. Patients were divided into low Lp(a) [Lp(a) < 30 mg/dL; 78 patients] and high Lp(a) [Lp(a) ≥ 30 mg/dL; 31 patients] groups. The main outcome was primary patency following EVT. Loss of primary patency was defined as a peak systolic velocity ratio > 2.4 on a duplex scan or > 50% stenosis on angiography. Cox proportional hazards analysis was performed to determine whether high Lp(a) levels were independently associated with loss of primary patency. The mean follow-up duration was 28 months. The rates of primary patency were 83 and 76% at 1 year and 75 and 58% at 2 years in the low and high Lp(a) groups, respectively (P = 0.02). After multivariate analysis, High Lp(a)[Lp(a) ≥ 30 mg/dL] (hazard ratio 2.44; 95% CI 1.10-5.44; P = 0.03) and female sex (hazard ratio 2.65; 95% CI 1.27-5.51; P < 0.01) were independent predictors of loss of primary patency. Lp(a) levels might be associated with primary patency after EVT for de novo femoropopliteal lesions.


Assuntos
Procedimentos Endovasculares , Artéria Femoral , Lipoproteína(a) , Doença Arterial Periférica , Artéria Poplítea , Grau de Desobstrução Vascular , Feminino , Humanos , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/patologia , Artéria Femoral/cirurgia , Lipoproteína(a)/sangue , Doença Arterial Periférica/sangue , Doença Arterial Periférica/patologia , Doença Arterial Periférica/cirurgia , Artéria Poplítea/patologia , Artéria Poplítea/cirurgia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
7.
Int J Cardiovasc Imaging ; 38(12): 2791-2799, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36445670

RESUMO

PURPOSE: This study evaluated whether optical frequency domain imaging (OFDI) accurately distinguish between fibroatheroma (FA) and pathological intimal thickening (PIT) compared with histopathology. METHODS: A total of 631 histological cross-sections from 14 autopsy hearts were analyzed for the comparison between OFDI and histological images. Of those, 190 (30%) sections were diagnosed with PIT and 120 (19%) with FA. The OFDI signal attenuation rate was calculated from an exponential. The lipid length was measured longitudinally by detection of sequential OFDI frames within a plaque segment containing lipids. The lipid arc was measured with a protractor centered in the center of the lumen. The fibrous cap thickness was defined as the minimum thickness of the signal rich band overlying PIT and FA. RESULTS: There was no significant difference in the OFDI signal attenuation rate between FA and PIT (3.09 ± 1.04 versus 2.79 ± 1.20, p = 0.13). However, the lipid length was significantly longer, the maximum lipid arc was significantly larger, and the fibrous cap thickness was significantly thinner in FA than in PIT (7.5 [4.3-10.3] mm versus 4.3 [2.7-5.8] mm, p < 0.0001, 125 [101-174]° versus 96 [74-131]°, p < 0.0001, and 220 [167-280] µm versus 260 [190-332] µm, p = 0.019). CONCLUSIONS: This study revealed OFDI may have the potential capability for discriminating FA from PIT based on the longitudinal and circumferential extent of lipid plaque, although the OFDI signal attenuation rate was similar between FA and PIT.


Assuntos
Doença da Artéria Coronariana , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Valor Preditivo dos Testes , Tomografia de Coerência Óptica , Coração , Lipídeos
8.
J Cardiol ; 80(2): 179-183, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35361523

RESUMO

BACKGROUND: High lipoprotein (a) [Lp (a)] levels are associated with worse long-term outcomes in patients undergoing percutaneous coronary intervention (PCI). However, there are limited studies investigating association between Lp (a) levels and long-term outcomes in the era of new generation drug-eluting stents (DES). METHODS: A total of 495 patients with available data on Lp (a) who underwent PCI for de novo lesions with new generation DES were enrolled between 2013 and 2017. The primary endpoint was the major adverse cardiovascular event (MACE), which was defined as a composite of cardiac death, myocardial infarction, stent thrombosis, clinically driven target lesion revascularization, and revascularization for new lesions during 3 years. Patients were divided into 2 groups according to the Lp (a) level: high Lp (a) group (≥30 mg/dL: n = 109) and low Lp (a) group (30 mg/dL>: n = 386). Multivariate Cox regression analysis was performed to identify the predictors for 3-year MACE. RESULTS: The incidence of 3-year MACE was significantly higher in high Lp (a) group than low Lp (a) group (33.0% vs. 15.9%, p < 0.001). Multivariable analysis showed that Lp (a) level of ≥30 mg/dL was an independent predictor for 3-year MACE (HR 2.01, 95%CI 1.30-3.11, p = 0.002). CONCLUSION: High Lp (a) level was associated with worse long-term outcome even in the era of new generation DES.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/etiologia , Humanos , Lipoproteína(a) , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
9.
JACC Case Rep ; 3(3): 380-384, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34317541

RESUMO

Creation of a distal re-entry site is widely performed to treat subintimal hematoma. However, this method has a risk of further vessel damage. The present aspiration technique after sealing the entry site by stenting is more promising because the hematoma can be reduced without additional vessel damage. (Level of Difficulty: Advanced.).

11.
J Atheroscler Thromb ; 28(5): 555-561, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-32863296

RESUMO

AIM: High levels of lipoprotein(a) [Lp(a)] are a risk factor for peripheral artery disease (PAD). However, the relationship between Lp(a) levels and the severity of femoropopliteal lesions in patients with PAD has not been systematically studied. This study aimed to assess the impact of Lp(a) levels on angiographic severity of femoropopliteal lesions in patients with PAD. METHODS: We retrospectively analyzed a single-center database including 108 patients who underwent endovascular therapy for de novo femoropopliteal lesions and measured the Lp(a) levels before therapy between June 2016 and September 2019. Patients were divided into low Lp(a) [Lp(a) <30 mg/dL; 77 patients] and high Lp(a) [Lp(a) ≥ 30 mg/dL; 31 patients] groups. Trans-Atlantic Inter-Society Consensus (TASC) II classification, calcification [referring to the peripheral arterial calcium scoring system (PACSS) classification], and lesion length were compared between the groups. RESULTS: The prevalence of TASC II class D (13% vs 38%, P<0.01) and severe calcification (PACSS 4) (6% vs 23%, P=0.02) was significantly higher and the lesion length longer (123±88 mm vs 175±102 mm, P<0.01) in the high Lp(a) group than in the low Lp(a) group. In multivariate analysis, Lp(a) ≥ 30 was an independent predictor for the prevalence of TASC II class D (HR=3.67, 95% CI 1.27-10.6, P=0.02) and PACSS 4 (HR=4.97, 95% CI 1.27-19.4, P=0.02). CONCLUSION: The prevalence of TASC II class D and severe calcification of femoropopliteal lesions was higher in patients with high Lp(a) than those with low Lp(a).


Assuntos
Artéria Femoral , Lipoproteína(a)/sangue , Doença Arterial Periférica/sangue , Doença Arterial Periférica/diagnóstico , Artéria Poplítea , Idoso , Idoso de 80 Anos ou mais , Angiografia , Procedimentos Endovasculares , Feminino , Humanos , Masculino , Doença Arterial Periférica/cirurgia , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença
12.
Clin Cardiol ; 44(2): 238-243, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33368316

RESUMO

BACKGROUND: Patients with non-ST-elevation myocardial infarction (NSTEMI) have worse long-term prognoses than those with ST-elevation myocardial infarction (STEMI). HYPOTHESIS: It may be attributable to more extended coronary atherosclerotic disease burden in patients with NSTEMI. METHODS: This study consisted of consecutive 231 patients who underwent coronary intervention for myocardial infarction (MI). To assess the extent and severity of atherosclerotic disease burden of non-culprit coronary arteries, two scoring systems (Gensini score and synergy between percutaneous coronary intervention with Taxus and cardiac surgery [SYNTAX] score) were modified by subtracting the score of the culprit lesion: the non-culprit Gensini score and the non-culprit SYNTAX score. RESULTS: Patients with NSTEMI had more multi-vessel disease, initial thrombolysis in myocardial infarction (TIMI) flow grade 2/3, and final TIMI flow grade 3 than those with STEMI. As compared to STEMI, patients with NSTEMI had significantly higher non-culprit Gensini score (16.3 ± 19.8 vs. 31.2 ± 25.4, p < 0.001) and non-culprit SYNTAX score (5.8 ± 7.0 vs. 11.1 ± 9.7, p < 0.001). CONCLUSIONS: Patients with NSTEMI had more advanced coronary atherosclerotic disease burden including non-obstruction lesions, which may at least in part explain higher incidence of cardiovascular events in these patients.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Efeitos Psicossociais da Doença , Humanos , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/cirurgia , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia
13.
Circ J ; 84(10): 1854-1861, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32779610

RESUMO

BACKGROUND: Although self-expanding drug-eluting stents (DES) have recently shown superior outcomes for superficial femoral artery (SFA) lesions, optimal sizing of DES diameter in SFA intervention is unclear.Methods and Results:A total of 40 de novo SFA lesions were randomized 1:1 to receive self-expanding DES with either a 1-mm or 2-mm larger diameter than the reference vessel diameter. Follow-up optical coherence tomography (OCT) was scheduled 6 months after DES implantation to evaluate the vascular response to the stents. Volume index (VI) was defined as volume divided by stent length. The primary endpoint was neointimal VI at 6 months. Baseline reference vessel diameter was similar between the 1-mm larger diameter group and the 2-mm larger diameter group (5.0±0.8 mm vs. 4.7±0.9 mm, P=0.35). Stent diameter was 6.3±0.6 mm in the 1-mm larger group and 7.1±0.6 mm in the 2-mm larger group (P<0.0001), and stent to reference vessel diameter ratio (SV ratio) was 1.3±0.2 and 1.5±0.2 (P<0.0001), respectively. At 6-month, neointimal VI was greater in the 2-mm larger diameter group (5.5±1.5 mm2vs. 9.6±3.4 mm2, P<0.001). The correlation analysis revealed that degree of neointimal VI was positively correlated with SV ratio (r=0.43, P<0.01). CONCLUSIONS: Implantation of self-expanding DES with a considerably high SV ratio resulted in neointimal hyperplasia in SFA lesions.


Assuntos
Stents Farmacológicos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Artéria Femoral/patologia , Neointima/etiologia , Paclitaxel/administração & dosagem , Doença Arterial Periférica/cirurgia , Stents Metálicos Autoexpansíveis/efeitos adversos , Idoso , Feminino , Artéria Femoral/diagnóstico por imagem , Seguimentos , Humanos , Hiperplasia/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Neointima/diagnóstico por imagem , Estudos Prospectivos , Desenho de Prótese , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento
14.
J Cardiol ; 75(6): 659-664, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31964546

RESUMO

BACKGROUND: The relationship between long-term outcome in patients with lower extremity artery disease (LEAD) and left ventricular (LV) diastolic dysfunction has not been systematically studied. The aim of this study was to assess the impact of LV diastolic dysfunction on the long-term outcome in patients with LEAD. METHODS: Two hundred LEAD patients (male 66 %, mean age 76±9 years) with preserved LV systolic function assessed by echocardiography (ejection fraction ≥50 %) were enrolled from a single center database between January 2013 and May 2015. We divided the patients into two groups on the basis of LV diastolic dysfunction, which was diagnosed based on the American Society of Echocardiography/European Association of Cardiovascular Imaging guidelines. The 3-year cumulative incidence of the primary endpoint was compared between LEAD patients with LV diastolic dysfunction and those without. The primary endpoint was a composite of major adverse cardiac and cerebrovascular events (MACCE: death, hospitalization for heart failure, myocardial infarction, and stroke). Multivariate analysis was performed to determine whether LV diastolic dysfunction was independently associated with the MACCE. RESULTS: LV diastolic dysfunction was identified in 31 % of LEAD patients. The mean observation period was 32±21 months. The 3-year cumulative incidence of MACCE occurred more frequently in patients with LV diastolic dysfunction than those without (35 % vs 23 %, p=0.01). In multivariate analysis, LV diastolic dysfunction (HR=1.96, 95 % CI 1.09-3.55, p=0.03) and critical limb ischemia (HR=2.52, 95 % CI 1.24-5.10, p=0.01) were an independent predictor for MACCE. CONCLUSION: LV diastolic dysfunction increased the risk for MACCE in patients with LEAD.


Assuntos
Artérias/fisiopatologia , Extremidade Inferior/fisiopatologia , Doenças Vasculares/fisiopatologia , Disfunção Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
15.
J Endovasc Ther ; 27(1): 77-85, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31948376

RESUMO

Purpose: To identify intravascular ultrasound (IVUS) findings that predict midterm stent patency in femoropopliteal (FP) lesions. Materials and Methods: A retrospective analysis was undertaken of 335 de novo FP lesions in 274 consecutive patients (mean age 72.4±8.2 years; 210 men) who had IVUS assessment before and after successful stent implantation. The mean lesion length was 13.2±9.8 cm. The primary outcome was primary patency at 24 months, defined as freedom from major adverse limb event (MALE) and in-stent restenosis (ISR). MALE was defined as major amputation or any target lesion revascularization (TLR). ISR was defined by a peak systolic velocity ratio >2.4 by duplex ultrasonography. Logistic regression analyses were performed to identify independent predictors of stent patency at 24 months; the results are presented as the odds ratio (OR) and 95% confidence interval (CI). Receiver operator characteristic (ROC) curve analysis was performed to determine the optimal threshold for prediction of stent patency at 24 months. Results: Over the 24-month follow-up, 18 (7%) patients died and 43 (15%) of 286 lesions were responsible for MALE (42 TLRs and 1 major amputation). Primary patency was estimated at 82.5% (95% CI 78.1% to 86.9%) at 12 months and 73.2% (95% CI 67.9% to 78.5%) at 24 months. Multivariable analysis revealed that longer lesion length (OR 0.89, 95% CI 0.82 to 0.97, p<0.01) was an independent predictor of declining patency, while cilostazol use (OR 3.45, 95% CI 1.10 to 10.78, p=0.03) and increasing distal reference external elastic membrane (EEM) area (OR 1.18, 95% CI 1.02 to 1.37, p=0.03) were associated with midterm stent patency. ROC curve analysis identified a distal reference EEM area of 29.0 mm2 as the optimal cut-point for prediction of 24-month stent patency (area under the ROC curve 0.764). Kaplan-Meier estimates of 24-month primary patency were 83.7% (95% CI 78.3% to 89.2%) in lesions with a distal EEM area >29.0 mm2 vs 53.1% (95% CI 42.9% to 63.3%) in those with a distal EEM area ≤29.0 mm2 (p<0.001). Conclusion: In FP lesions with a larger distal vessel area estimated with IVUS, stent implantation can be considered as a reasonable treatment option, with the likelihood of acceptable midterm results.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Femoral/diagnóstico por imagem , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Stents , Ultrassonografia de Intervenção , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Velocidade do Fluxo Sanguíneo , Feminino , Artéria Femoral/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/fisiopatologia , Artéria Poplítea/fisiopatologia , Valor Preditivo dos Testes , Recidiva , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Grau de Desobstrução Vascular
16.
JACC Cardiovasc Interv ; 13(1): 74-82, 2020 01 13.
Artigo em Inglês | MEDLINE | ID: mdl-31838108

RESUMO

OBJECTIVES: This study assessed the efficacy of the tip detection method during intravascular ultrasound (IVUS)-based 3-dimensional (3D) wiring with a new chronic total occlusion (CTO)-specific IVUS system (AnteOwl IVUS [AO-IVUS]) for CTO percutaneous coronary intervention (PCI). BACKGROUND: The study developed angiography-based 3D wiring for CTO-PCI. Previously, the authors produced a short-tip CTO-specific IVUS system (Navifocus WR IVUS [Navi-IVUS]), which has been upgraded into the AO-IVUS system by adding a pullback transducer system for IVUS-based 3D wiring. METHODS: A CTO lesion 20 mm in length composed of 2.5% agar was experimentally inserted into the coronary artery of a beating heart model. The target (a microcatheter with a 0.6-mm lumen) was placed in the distal part of the CTO lesion. IVUS-guided wiring was performed to insert the guidewire into the target using the Navi-IVUS and then using the AO-IVUS 8 times each. In wiring with AO-IVUS, the IVUS-based 3D wiring using the tip detection method was performed. The crossing time and the number of punctures to the target were calculated. RESULTS: The crossing time was significantly shortened and the number of punctures was significantly reduced in AO-IVUS-based wiring compared with Navi-IVUS-based wiring (median crossing time 80.5 s [interquartile range: 44.0 to 112.3 s] vs. 333.0 s [interquartile range: 88.8 to 790.0 s]; p = 0.036; median 1.0 puncture [interquartile range: 1.0 to 2.0 punctures] vs. 24.0 punctures [interquartile range: 5.8 to 52.5 punctures]; p = 0.001). CONCLUSIONS: The tip detection method enables the authors to easily perform the IVUS-based 3D wiring, and the new CTO IVUS system will facilitate this method in clinical practice.


Assuntos
Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Intervenção Coronária Percutânea/instrumentação , Ultrassonografia de Intervenção , Idoso , Cateterismo Cardíaco/efeitos adversos , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Feminino , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Fatores de Tempo
17.
JACC Cardiovasc Interv ; 12(6): 545-555, 2019 03 25.
Artigo em Inglês | MEDLINE | ID: mdl-30898251

RESUMO

OBJECTIVES: This study sought to compare the procedural outcomes of percutaneous coronary intervention for chronic total occlusion between the periods before and after introduction of 3-dimensional (3D) wiring. BACKGROUND: Previously, we reported a 3D wiring method by which the operator can construct real-time mental 3D images from 2 perpendicular angles of X-ray system monitor during percutaneous coronary intervention for chronic total occlusion. METHODS: A total of 137 chronic total occlusion lesions that could not be passed by tapered soft wires in our hospital between 2012 and 2017 were retrospectively enrolled in the study. RESULTS: Overall success rate was significantly higher in the 3D wiring group (n = 69) than the non-3D wiring group (n = 68) (98% vs. 90%, respectively; p = 0.027). In the primary antegrade cases, the first antegrade approach time was significantly shorter in the 3D wiring group than the non-3D wiring group (42 ± 29 vs. 30 ± 16 min, respectively; p = 0.01). In cases where the antegrade approach was continued throughout the procedure, the success rate was significantly higher in the 3D wiring group than the non-3D wiring group (100% vs. 89.2%, respectively; p = 0.033). Vessel perforation by the antegrade wire tended to be lower in the 3D wiring group than the non-3D wiring group (1% vs. 11%, respectively; p = 0.055). CONCLUSIONS: 3D wiring enables accurate guidewire control, which improves the success rate of antegrade wiring and reduces the antegrade procedure time, resulting in improvement of the overall success rate.


Assuntos
Cateterismo Cardíaco/métodos , Oclusão Coronária/terapia , Intervenção Coronária Percutânea/métodos , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
18.
J Cardiol ; 73(6): 453-458, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30792034

RESUMO

BACKGROUND: Peripheral artery disease (PAD) is often accompanied by heart failure with preserved ejection fraction (HFpEF). Left ventricular (LV) diastolic dysfunction is related to HFpEF. The aim of this study was to compare LV diastolic function between patients with or without PAD. METHODS: One thousand one hundred twenty-one patients (male 56%, mean age 68±13 years) with available preserved LV systolic function assessed by echocardiography (ejection fraction ≥50%) were enrolled from a single-center database between January 2013 and May 2015. PAD was defined as ankle brachial index <0.9 or previous history of lower extremity bypass and/or endovascular therapy. Diagnosis of LV diastolic dysfunction was based on the American Society of Echocardiography and European Association of Cardiovascular Imaging guidelines. The prevalence of LV diastolic dysfunction was compared between patients with PAD and those without PAD. Multivariate analysis was performed by logistic regression analyses to assess predictors of LV diastolic dysfunction. RESULTS: Two hundred patients (18%) had PAD. Patients with PAD had higher E/e' (15.3±7.4 vs 11.8±5.5, p<0.01), tricuspid regurgitation velocity (2.37±0.33 vs 2.19±0.28m/s, p<0.01), left atrial volume index (40.6±20.2 vs 32.1±13.6mL/m2, p<0.01), and lower e' (5.68±1.70 vs 6.38±2.07cm/s, p<0.01) than patients without PAD. The prevalence of LV diastolic dysfunction was higher (31% vs 12%, p<0.01) in patients with PAD compared to patients without PAD. Multivariate analysis showed that PAD was an independent predictor of LV diastolic dysfunction (adjusted odds ratio: 1.77, 95% confidence interval: 1.13-2.65, p=0.01). CONCLUSION: The prevalence of LV diastolic dysfunction was higher in patients with PAD than patients without PAD.


Assuntos
Diástole/fisiologia , Doença Arterial Periférica/fisiopatologia , Função Ventricular Esquerda/fisiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ecocardiografia , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
19.
Ann Vasc Surg ; 58: 380.e13-380.e16, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30802577

RESUMO

Pseudoaneurysm of below-the-knee arteries after a high tibial osteotomy (HTO) is rare. A 69-year-old woman with history of right HTO a half year ago had performed a left HTO for osteoarthritis. Postoperatively, she had swelling and pain of the left lower leg. Computed tomography and echocardiography revealed the pseudoaneurysm of peroneal artery (PA). After the release of the covered stent graft, the pseudoaneurysm of the PA did not disappear, it was completely excluded in the completion angiogram.


Assuntos
Falso Aneurisma/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Perna (Membro)/irrigação sanguínea , Osteotomia/efeitos adversos , Stents , Tíbia/cirurgia , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Angiografia Digital , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Desenho de Prótese , Resultado do Tratamento , Ultrassonografia de Intervenção
20.
Nurs Health Sci ; 20(3): 323-330, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30215884

RESUMO

There has been little research exploring Japanese nursing students' experiences of having Western instructors in their nursing programs. The purpose of the present study was to describe Japanese nursing students' lived experiences of being taught by foreign faculty. A qualitative design using an interpretive phenomenology approach was used with purposeful sampling. Graduate and undergraduate nursing students (n = 13), who had the experience of being taught by a foreign faculty member for at least one semester, were recruited. Six themes emerged that suggested the participants went through an evolutionary process as they worked to understand and make meaning of these intercultural experiences: struggling with uncertainty, working to understand, discovering differences in teaching styles, opening my eyes to the world, thinking differently now, and wanting to know more. The work students must do to understand foreign teachers influences what they are able to learn, and must be taken into consideration by both faculty and students. To fully realize meaningful teaching outcomes within this intercultural context, it is essential that students have sustained exposure to foreign faculty.


Assuntos
Relações Interpessoais , Estudantes de Enfermagem/psicologia , Bacharelado em Enfermagem/métodos , Educação de Pós-Graduação em Enfermagem/métodos , Humanos , Pesquisa Qualitativa , Ensino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...