Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Innov Card Rhythm Manag ; 8(5): 2717-2723, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-32494449

RESUMO

The leadless cardiac pacemaker was selected to provide empiric pacing support in this patient with a manifest mid-septal accessory pathway who had undergone a previous ablation resulting in injury to the compact atrioventricular node. Although this patient's accessory pathway currently demonstrates stable antegrade conduction properties, diminished and complete resolution of manifest pre-excitation has been well described in patients with Wolff-Parkinson-White syndrome. Because of the patient's young age, an increased risk is present for long-term complications inherent with traditional transvenous pacing. The Nanostim leadless pacemaker (St. Jude Medical, St. Paul, MN, USA) was implanted into the right ventricular myocardium without complication. Pacing performance has remained stable, and the patient has been free of device-related adverse events at 19 months after implant.

3.
J Interv Card Electrophysiol ; 37(2): 163-8, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23585239

RESUMO

BACKGROUND: Vascular complications are a known risk of catheter-based pulmonary vein antral isolation (PVAI). Procedure-related thromboembolic events necessitate full-dose anticoagulation, which worsens outcomes in the event of vascular access injury. OBJECTIVE: Real-time ultrasound allows direct visualization of vascular structures. We hypothesized that ultrasound use with venipuncture reduces vascular complications associated with PVAI. METHODS: Retrospective analysis of all adverse events occurring with PVAI was performed during two periods: 2005-2006 when ultrasound was not used and 2008-2010 when ultrasound was routinely employed. All patients received full-dose IV heparin during PVAI. In the no ultrasound cohort, only 14 % underwent PVAI without stopping warfarin, while 91 % of patients in the ultrasound cohort were on continued warfarin. Only patients deemed at high risk for thromboembolism with a periprocedural international normalized ratio (INR) less than 2 were bridged with subcutaneous low-molecular-weight heparin. RESULTS: Ultrasound reduced total vascular complications (1.7 vs. 0.5 %, p < 0.01) and decreased the incidence of major vascular complications by sevenfold. Warfarin with INR ≥ 1.2 on the day of PVAI was associated with more vascular complications (4.3 vs. 1.2 %, p < 0.01). Ultrasound guidance overcame the risk associated with warfarin therapy. Vascular complications in anticoagulated patients with INR ≥ 1.2 using ultrasound guidance were two- and ninefold lower than those in patients not using ultrasound with an INR < 1.2 (0.5 vs. 1.2 %, p < 0.05) and INR ≥ 1.2 (0.5 vs. 4.3 %, p < 0.01), respectively. CONCLUSION: Ultrasound-guided venipuncture improves the safety profile of PVAI, reducing vascular complications in patients on warfarin to levels below those with no ultrasound and off warfarin.


Assuntos
Ablação por Cateter/estatística & dados numéricos , Flebotomia/estatística & dados numéricos , Complicações Pós-Operatórias/prevenção & controle , Veias Pulmonares/cirurgia , Ultrassonografia/estatística & dados numéricos , Tromboembolia Venosa/prevenção & controle , Varfarina/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Causalidade , Comorbidade , Sistemas Computacionais , Feminino , Humanos , Masculino , Ohio/epidemiologia , Complicações Pós-Operatórias/epidemiologia , Prevalência , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Cirurgia Assistida por Computador/estatística & dados numéricos , Resultado do Tratamento , Tromboembolia Venosa/epidemiologia