Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Zhonghua Wai Ke Za Zhi ; 61(12): 1080-1085, 2023 Dec 01.
Artigo em Chinês | MEDLINE | ID: mdl-37932144

RESUMO

Objectives: To verify the reliability and validity of the frailty assessment scale for elderly patients with inguinal hernia and to evaluate the value of its clinical application. Methods: A convenience sampling method was used to collect 129 geriatric patients who underwent inguinal hernia surgery from January 2018 to January 2023 in nine hospitals in Liaoning Province. There were 120 males and 9 females, of whom 89 patients were 60 to <75 years old, 33 patients were 75 to <85 years old and 7 patients were ≥85 years old. The 129 patients included 11 elderly patients with inguinal hernia who had recovered from preoperative infection with COVID-19. Statistical methods such as Cronbach's coefficient, Kaiser-Meyer-Olkin test, Bartlett's test, Pearson's correlation analysis, etc. were calculated to verify the reliability indexes such as feasibility, content validity, structural validity, criterion-related validity, internal consistency reliability, and re-test reliability. Taking the 5-item modified frailty index (5-mFI) as the gold standard, the area under the curve was used to analyze the ability of the two scales to predict the occurrence of postoperative acute urinary retention, postoperative delirium, poor incision healing, operative hematoma seroma, and postoperative complications. Results: The frailty assessment scale for elderly patients with inguinal hernia showed good reliability and validity (valid completion rate of 99.2%; item content validity index of 1.000, and the scale content validity index of 1.000; exploratory factor analysis extracted a total of 1 principal component, and factor loadings of each item of 0.565 to 0.873; the AUC for frailty diagnosis using 5-mFI as the gold standard of 0.795 (P<0.01) Cronbach's coefficient of 0.916, retest reliability coefficient of 0.926), it could effectively predict postoperative acute urinary retention, delirium, hematoma seroma in the operative area and total complications (AUC of 0.746, 0.870, 0.806, and 0.738, respectively; all P<0.05), and prediction efficiency was higher than that of 5-mFI (AUC of 0.694, 0.838, 0.626 and 0.641, P<0.05 for delirium only), but both scales were inaccurate in predicting poor incision healing (AUC of 0.519, P=0.913 for the frailty assessment scale and 0.455, P=0.791 for the 5-mFI). Conclusions: The frailty assessment scale for elderly patients with inguinal hernia is reliable and significantly predicts the occurrence of postoperative adverse events in elderly inguinal hernia patients. The scale can also be used for preoperative frailty assessment in elderly patients with inguinal hernia after rehabilitation from COVID-19 infection.


Assuntos
COVID-19 , Delírio , Fragilidade , Hérnia Inguinal , Retenção Urinária , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , COVID-19/complicações , Fragilidade/diagnóstico , Fragilidade/complicações , Hematoma/complicações , Hérnia Inguinal/diagnóstico , Hérnia Inguinal/cirurgia , Complicações Pós-Operatórias/etiologia , Reprodutibilidade dos Testes , Seroma/complicações , Inquéritos e Questionários , Retenção Urinária/complicações , Pessoa de Meia-Idade
2.
Zhonghua Yi Xue Za Zhi ; 103(7): 506-512, 2023 Feb 21.
Artigo em Chinês | MEDLINE | ID: mdl-36800774

RESUMO

Objective: To investigate the features of morphological and functional parameters of cardiac magnetic resonance (CMR) in patients with systemic light chain (AL) amyloidosis, and the prognostic values of these related parameters. Methods: The data of 97 patients (including 56 males and 41 females, aged 36 to 71 years) with AL amyloidosis from April 2016 to August 2019 in the General Hospital of Eastern Theater Command were retrospectively analyzed. All patients underwent CMR examination. Those patients were divided into survival (n=76) and death groups (n=21) according to the clinical outcomes, and the differences in clinical baseline and CMR parameters between the two groups were analyzed and compared. A smooth curve fitting was used to analyze the association between morphological and functional parameters and extracellular volume (ECV), and Cox regression models were conducted to explore the association between related parameters and mortality. Results: The left ventricular global function index (LVGFI), myocardial contraction fraction (MCF) and stroke volume index (SVI) decreased with increasing ECV [ß (95%CI) was -0.566 (-0.685--0.446), -1.201 (-1.424--0.977), -0.149 (-0.293--0.004), respectively;all P<0.05]. Left ventricular mass index (LVMI), and diastolic left ventricular global peak wall thickness (LVGPWT) increased with increasing ECV [ß(95%CI) was 1.440 (1.142-1.739), 0.190 (0.147-0.233), respectively;both P<0.001]. While left ventricular ejection fraction (LVEF) began to decrease only at higher amyloid burden (ß=-0.460, 95%CI:-0.639--0.280, P<0.001). The median follow-up time was 39 months (range 2-64 months), and 21 patients died during the follow-up period. The estimated survival rates according to Kaplan-Meier curves at 1, 3, and 5 years were 92.8%, 78.7%, and 77.1%, respectively. MCF<39% (HR=10.266, 95%CI: 4.093-25.747) and LVGFI<26% (HR=9.267, 95%CI: 3.705-23.178) were independent risk factors for death in patients with AL amyloidosis after adjusting for other CMR parameters (P<0.001). Conclusion: Multiple morphologic and functional parameters of CMR vary with the increase of ECV. MCF<39% and LVGFI<26% were independent risk factors for death.


Assuntos
Amiloidose , Amiloidose de Cadeia Leve de Imunoglobulina , Feminino , Masculino , Humanos , Prognóstico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Espectroscopia de Ressonância Magnética
3.
J Synchrotron Radiat ; 30(Pt 1): 35-50, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36601924

RESUMO

A promising accelerator light source mechanism called steady-state microbunching (SSMB) is being actively studied. With the combination of strong coherent radiation from microbunching and high repetition rate of a storage ring, high-average-power narrow-band radiation can be anticipated from an SSMB storage ring, with wavelengths ranging from THz to soft X-ray. Such a novel light source could provide new opportunities for accelerator photon science like high-resolution angle-resolved photoemission spectroscopy and industrial applications like extreme ultraviolet (EUV) lithography. In this paper, a theoretical and numerical study of the average and statistical properties of coherent radiation from SSMB are presented. The results show that 1 kW average-power quasi-continuous-wave EUV radiation can be obtained from an SSMB ring provided that an average current of 1 A and a microbunch train with bunch length of 3 nm can be formed at the radiator which is assumed to be an undulator. Together with the narrow-band feature, the EUV photon flux can reach 6 × 1015 photons s-1 within a 0.1 meV energy bandwidth, which is three orders of magnitude higher than that in a conventional synchrotron source and is appealing for fundamental condensed matter physics and other research. In this theoretical investigation, we have generalized the definition and derivation of the transverse form factor of an electron beam which can quantify the impact of its transverse size on coherent radiation. In particular, it has been shown that the narrow-band feature of SSMB radiation is strongly correlated with the finite transverse electron beam size. Considering the pointlike nature of electrons and quantum nature of radiation, the coherent radiation fluctuates from microbunch to microbunch, or for a single microbunch from turn to turn. Some important results concerning the statistical properties of SSMB radiation are presented, with a brief discussion on its potential applications, for example the beam diagnostics. The presented work is of value for the development of SSMB to better serve potential synchrotron radiation users. In addition, this also sheds light on understanding the radiation characteristics of free-electron lasers, coherent harmonic generation, etc.

4.
Zhonghua Yi Xue Za Zhi ; 102(33): 2563-2566, 2022 Sep 06.
Artigo em Chinês | MEDLINE | ID: mdl-36058677

RESUMO

CT angiography derived fractional flow reserve (CT-FFR) has been an important tool for evaluating functional significance of coronary stenosis since 2011, promoting coronary CT angiography (CCTA) from the era of traditional anatomical evaluation to a new era of functional evaluation,playing a key role in guiding clinical decisions and prognostic evaluation of coronary artery disease. This review focuses on the innovative research and contributions of Chinese scholars' in CT-FFR filed, including homemade techniques, extending clinical applications and generalization of CT-FFR.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Humanos , Curva ROC
5.
Zhonghua Yu Fang Yi Xue Za Zhi ; 56(6): 843-846, 2022 Jun 06.
Artigo em Chinês | MEDLINE | ID: mdl-35785867

RESUMO

To investigate the temporal trend of antibiotic use among children in Shanghai from 2017 to 2020. The stratified cluster sampling method was used to establish a dynamic cohort of healthy children based on primary schools in Changning District, Shanghai. In the cohort, there were 282 children from 2017, 287 children from 2018, 294 from 2019 and 301 from 2020. A total of 700 children aged 7-11 years were included in the study. The basic information and antibiotic use of children were investigated by questionnaire every year, and their height and weight were measured at the same time. Chi-square test was used to analyze the difference of antibiotic use rate in each year and generalized estimation equation was used to analyze the temporal trend of antibiotic use. The results showed that the use rates of all antibiotics, cephalosporins, azithromycin and other antibiotics (including penicillin, lincomycin, quinolones, etc.) of children between 2017 and 2020 were 15.6%, 10.5%, 2.7%, and 2.4%, respectively. In 2017, 2018, 2019, and 2020, there were significant differences for the use rates of total antibiotics and other antibiotics in children (P=0.033, P=0.040), and there were no significant differences for the use rates of cephalosporins and azithromycin (P=0.274, P=0.455). After adjusting for children's basic characteristics, the generalized estimation equation showed that the annual use rate of all antibiotics, cephalosporins, and other antibiotics decreased over time.


Assuntos
Antibacterianos , Azitromicina , Antibacterianos/uso terapêutico , Azitromicina/uso terapêutico , Cefalosporinas/uso terapêutico , Criança , China , Humanos , Instituições Acadêmicas
6.
Zhonghua Yi Xue Za Zhi ; 101(39): 3187-3189, 2021 Oct 26.
Artigo em Chinês | MEDLINE | ID: mdl-34689528

RESUMO

In recent years, cardiovascular imaging has become an important tool to evaluate cardiovascular diseases, which can provide anatomical and function information in multidimensional ways, and is expected to have a positive impact on the diagnosis and treatment of cardiovascular diseases. This editorial briefly describes the current status of advanced cardiovascular CT imaging in cardiovascular diseases on diagnosis, treatment, decision-making and prognostic evaluation, including CT-derived flow fractional reserve, CT perfusion, pericoronary adipose tissue and application of artificial intelligence, in order to promote the clinical transformation of these technologies.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Inteligência Artificial , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Humanos , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X
7.
Zhonghua Yi Xue Za Zhi ; 101(39): 3208-3213, 2021 Oct 26.
Artigo em Chinês | MEDLINE | ID: mdl-34689532

RESUMO

Objective: To explore the influence of measurement sites on the diagnostic performance of coronary computed tomography angiography (CCTA) -derived instantaneous wave-free ratio (iFRCT) for coronary stenosis ischemia. Methods: A total of 44 patients, including 27 males and 17 females aged from 44 to 83 (59±90) years, who underwent coronary computed tomography angiography (CCTA) and invasive fractional flow reserve (FFR) in the Department of Radiology, Eastern Theater Command General Hospital from February 2009 to May 2018 were retrospectively collected. Based on CCTA images, iFRCT values at different locations (stenosis, proximal downstream of stenosis, 2 cm downstream of stenosis, 3 cm downstream of stenosis, and 4 cm downstream of stenosis) were calculated through fluid mechanics simulation. With invasive FFR≤0.80 as the reference standard, receiver operating characteristic (ROC) was used to analyze and evaluate the diagnostic performance of iFRCT in different sites. Bland-Altman and spearman correlation coefficient were used to analyze the consistency between iFRCT and invasive FFR. Intraclass correlation coefficient (ICC) and spearman correlation coefficient were used to test the repeatability of iFRCT. Results: iFRCT values at the proximal downstream of the stenosis (approximately 1 cm downstream of the stenosis) was superior to other measurement sites in the diagnosis of coronary ischemic specific stenosis. The threshold, area under the curve, sensitivity, specificity and accuracy of iFRCT at the stenosis were 0.91, 0.87 (95%CI:0.76~0.96), 82% (95%CI:48%~97%), 76% (95%CI:57%~88%) and 77% (95%CI: 63%~87%), respectively. Bland-Altman analysis showed that the mean differences between iFRCT and FFR at the proximal downstream of the stenosis was 0.07 (95%LoA: 0.06~0.09) and Spearman correlation coefficient was 0.53 (P<0.001). At the proximal downstream of the stenosis, the intraobserver ICC of iFRCT was 0.92 (95%CI: 0.85 ~0.95), the correlation coefficient was 0.85 (P<0.001); the interobserver ICC was 0.84 (95%CI: 0.60~0.94), correlation coefficient was 0.75 (P<0.001), demonstrating good repeatability between iFRCT and FFR. Conclusion: With the invasive FFR value as reference standard, iFRCT had a high diagnostic performance in detecting myocardial ischemia and the best measurement site was the proximal downstream of the stenosis.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Isquemia Miocárdica , Angiografia por Tomografia Computadorizada , Constrição Patológica , Angiografia Coronária , Estenose Coronária/diagnóstico por imagem , Feminino , Humanos , Isquemia , Masculino , Isquemia Miocárdica/diagnóstico por imagem , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X
8.
Zhonghua Yi Xue Za Zhi ; 101(39): 3214-3220, 2021 Oct 26.
Artigo em Chinês | MEDLINE | ID: mdl-34689533

RESUMO

Objective: To explore the association of coronary perivascular fat attenuation index (FAI), the parameters of plaque and fractional flow reserve (FFR). Methods: A total of 113 patients (with 141 plaques) (78 males and 35 females, age from 40 to 83 years) with stable coronary artery disease were retrospectively collected from Jingling Hospital and Shanghai Sixth People's Hospital. All the patients underwent coronary CT angiography and invasive FFR examinations. The quantitative and qualitative parameters of plaque and vessel (such as the length and volume of plaque, the characteristics of plaque and high-risk plaque) and the FAI around the plaque were measured. The patients were divided into positive FAI group (n=46) and negative FAI group (n=66) according to the standard of whether the threshold of FAI≥ -70 HU. The quantitative indexes, including age, the length and volume of plaque, minimal lumen area (MLA) and FAI, as well as the qualitative indexed, including the characteristics of plaque, the number and characteristic of high-risk plaque and the number of patients and plaque with positive FFR were compared between the two groups. Further, logistic regression analysis was performed to analyze the correlation among myocardial ischemia, age, the length of plaque, minimal lumen area (MLA), FAI and so on. ROC curve was used for evaluating the performance of each parameter. Results: Compared to the negative FAI group, positive FAI group had lower MLA (2.00±1.33 mm2 vs 4.13±2.41 mm2, P<0.001). The proportion of patients and vessels with FFR<0.75 in positive FAI group were significantly higher than that in negative FAI group (21.3% vs 4.5%, P=0.006; 23.2% vs 8.2%, P=0.016). The FAI between high-risk plaque and non-high-risk plaque had no significant difference (21.2% vs 16.1%, P=0.451). FAI predicted myocardial ischemia (AUC=0.666, P=0.021) and significantly improved the prediction efficiency of complex model(0.915 vs 0.951,P=0.033). Conclusion: Lower MLA and higher incidence of myocardial ischemia were associated with patients with higher FAI. In addition, FAI has a certain prediction efficiency and can provide incremental value for the determination of myocardial ischemia.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Tecido Adiposo , Adulto , Idoso , Idoso de 80 Anos ou mais , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
9.
Zhonghua Yi Xue Za Zhi ; 100(15): 1148-1153, 2020 Apr 21.
Artigo em Chinês | MEDLINE | ID: mdl-32311878

RESUMO

Objective: To compare the radiation dose and image quality of noncontrast chest CT and detection of ground-glass opacity pulmonary nodules (GGN) in domestic 128-slice spiral CT with the other CT scanners from three main stream manufacturers. Methods: From May 8, 2018 to October 31, 2018, noncontrast chest CT images from Neusoft 128-slice CT (75 males, 25 females, (42±16) years), dual-source 64-slice CT (53 males, 47 females, (50±16) years) and dual-source 128-slice CT scanners(69 males, 31 females, (62±17) years), Toshiba 128-slice CT (51 males, 49 females, (58±13) years) and GE 128-slice CT scanner (55 males, 45 females, (60±10) years) were collected in Eastern Theater Command and Tianjin People's Hospital. Radiation dose and image quality were evaluated.GGN detected both in Neusoft CT and dual-source CT scanners were used to analyze the displaying ability of lesions. Results: The noise in lung window of Neusoft CT ((37.8±4.9) HU) was higher than that of other mainstream CT scanners, and the noise in mediastinal window ((8.4±1.9) HU) was lower than that of GE 128-slice CT ((9.8±3.2) HU), but higher than that of dual-source CT and Toshiba 128-slice CT ((6.9±3.5)HU) (P<0.05). The absolute value of lung SNR in Neusoft CT was lower than that of other mainstream CT scanners, and the SNR in aorta (4.6±1.3) was lower than those of dual-source CT and Toshiba 128-slice CT(6.8±2.2) (P<0.05), but was not statistically significant compared with GE 128-slice CT (5.0±1.7). The mean CT value of upper lung ((-863±31) HU) at Neusoft CT was higher than 128-row dual-source CT ((-869±35) HU), and the mean CT value of aorta ((37±7) HU) was lower than that of Toshiba 128-slice CT((42±7) HU) and GE 128-slice CT ((45±9) HU) (P<0.05), while the mean CT values of the remaining lung and aorta were not statistically significant (P>0.05). The two readers had good to excellent consistency for image quality in five scanners (the highest kappa value=0.984). The delineation ability of Neusoft CT for GGN boundary was lower than that of dual-source CT (P<0.05), but had similar abilities to display the solid components, lobulation, burring, vacuoles, vascular bundle sign and pleural depression sign of GGN (all P>0.05). Radiation dose of Neusoft CT was lower than Toshiba 128-slice CT, but higher than dual-source 64-sliceCT and GE 128-slice CT scanners (P<0.05). Conclusions: With lower radiation dose than Toshiba 128-slice CT, Neusoft CT chest examination can meet the requirements of clinical diagnosis, but higher radiation dose and the lower image quality than dual-source CT and GE 128-slice CT shown in this study indicate further improvement is needed in terms of software and hardware.


Assuntos
Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X , Idoso , Feminino , Humanos , Pulmão , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Software
10.
J Integr Neurosci ; 16(1): 33-55, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28891498

RESUMO

In this study, we provide a foundational model of ion transport processes in the intracellular and extracellular compartments of neurons at the nanoscale. There are two different kinds of ionic transport processes: (i) ionic transport across the neuronal membrane (trans-membrane), and (ii) ionic transport along both the intracellular and extracellular surfaces of the membrane. Brownian dynamics simulations are used to give a description of ionic trans-membrane transport. Electro-diffusion is used to model ion transport along the membrane surface, and the two transport processes can be linked analytically. In our model, we found that the interactions between ions and ion channels result in high-frequency ionic oscillations during trans-membrane transport. In ion transport along the membrane, high-frequency ionic oscillations may be evoked on both the intracellular and extracellular surfaces of the plasma membrane. The electric field caused by Coulomb interactions between the ions is found to be the most likely origin of those ionic oscillations.


Assuntos
Transporte de Íons/fisiologia , Potenciais da Membrana/fisiologia , Modelos Neurológicos , Neurônios/metabolismo , Animais , Difusão , Eletricidade , Canais Iônicos/metabolismo , Íons/metabolismo
11.
J Opt Soc Am A Opt Image Sci Vis ; 34(4): 576-582, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28375327

RESUMO

Non-paraxial perturbation wave equations are solved for general astigmatic Gaussian beams for the first time, to the best of our knowledge, in the angular spectrum representation by taking into account generic boundary conditions. Expressions for second-order corrections are derived and exemplified with an optical cavity made of two cylindrical mirrors. Non-paraxial corrections can lead, depending on the choice of boundary conditions, to a transverse S-shaped beam mode, which has been qualitatively been observed in a highly divergent non-planar four-mirror cavity.

12.
Rev Sci Instrum ; 85(3): 033102, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689559

RESUMO

We report the Tilt-Locking (TL) technique applied to lock a laser in pulsed regime to a 28,000 high finesse Fabry-Perot cavity. Preliminary experimental results show that TL technique is comparable with the well-known Pound-Drever-Hall technique. This study is the first to implement the TL technique to lock a pulsed laser to a high-finesse optical cavity. Very high and stable coupling is obtained. The coupling rate is ~80%, and locking can last for more than 1 h. Furthermore, while previously published papers have focused on near field case, in this study we will give the error signal shape simulation for the far field case. We will show that for different types of error sources, the split photodiode transverse position can be carefully adjusted to obtain a symmetrical error signal. Our experimental results are consistent with the simulations.

13.
Rev Sci Instrum ; 85(3): 033305, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689573

RESUMO

There has been great interest in building compact synchrotrons for various applications, for example, inverse Compton scattering X-ray sources. However, the beam injection and extraction in compact rings require careful design for the lack of space. In this paper, we propose a simple combined injection-extraction scheme exploiting the fringe field of existing dipole magnets instead of additional septum magnets. This scheme is illustrated by using the 4.8 m ring proposed for Tsinghua Thomson scattering X-ray source as an example. Particle tracking is applied to demonstrate the validity of this scheme.

14.
Phys Rev Lett ; 112(3): 035003, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24484147

RESUMO

The evolution of beam phase space in ionization injection into plasma wakefields is studied using theory and particle-in-cell simulations. The injection process involves both longitudinal and transverse phase mixing, leading initially to a rapid emittance growth followed by oscillation, decay, and a slow growth to saturation. An analytic theory for this evolution is presented and verified through particle-in-cell simulations. This theory includes the effects of injection distance (time), acceleration distance, wakefield structure, and nonlinear space charge forces, and it also shows how ultralow emittance beams can be produced using ionization injection methods.

15.
Phys Rev Lett ; 111(1): 015003, 2013 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-23863007

RESUMO

The production of ultrabright electron bunches using ionization injection triggered by two transversely colliding laser pulses inside a beam-driven plasma wake is examined via three-dimensional particle-in-cell simulations. The relatively low intensity lasers are polarized along the wake axis and overlap with the wake for a very short time. The result is that the residual momentum of the ionized electrons in the transverse plane of the wake is reduced, and the injection is localized along the propagation axis of the wake. This minimizes both the initial thermal emittance and the emittance growth due to transverse phase mixing. Simulations show that ultrashort (~8 fs) high-current (0.4 kA) electron bunches with a normalized emittance of 8.5 and 6 nm in the two planes, respectively, and a brightness of 1.7×10(19) A rad(-2) m(-2) can be obtained for realistic parameters.

16.
Rev Sci Instrum ; 84(2): 022704, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23464186

RESUMO

We propose and analyze a scheme to generate enhanced ultrabroadband terahertz (THz) radiation through coherent transition radiation emitted by ultrashort electron beams based on a 10.5 m beamline at Tsinghua University. The proposed scheme involves the initial compression of the electron beam with a few hundred pC charges using a velocity bunching scheme (i.e., RF compression) in an under-compression mode instead of the usual critical-compression mode in order to maintain a positive energy chirp at the exit of the traveling wave accelerator. After a long drift segment, the particles in the tail catch up with the bunch head. More than 80% of the particles are distributed in a spike with an rms length less than 20 fs. Such beams correspond to an ultrabroadband coherent transition radiation (CTR) spectrum of 0.1 THz to 25 THz, with the single-pulse THz radiation energy of up to 50 µJ. The principle of CTR and under-compression mode of velocity bunching are introduced in this paper. And the ASTRA simulation parameters and the stability of the system are also discussed.

17.
Inj Prev ; 15(4): 248-51, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19651998

RESUMO

OBJECTIVE: To evaluate the effectiveness of an 18-month multifaceted intervention designed to reduce the incidence of falls in community-living older adults in China. METHODS: A population-based community trial evaluated by before-and-after cross-sectional surveys. Four residential communities were randomised to either a multifaceted intervention or a control condition. Baseline information was collected from a sample of older adults in each community. A 1-year annual fall rate was calculated after an 18-month comprehensive intervention. RESULTS: After intervention, 7.19% of the intervention community sample reported falls, compared with 17.86% of the control community sample (p<0.000). The annual fall rate decreased by 10.52% in the intervention communities, whereas the difference in control communities was not statistically significant. CONCLUSIONS: Multifaceted interventions in community settings may be useful in preventing falls among older people, and can be applied in similar settings in China.


Assuntos
Acidentes por Quedas/prevenção & controle , Serviços de Saúde Comunitária/métodos , Acidentes por Quedas/estatística & dados numéricos , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , China , Estudos de Viabilidade , Feminino , Conhecimentos, Atitudes e Prática em Saúde , Serviços de Saúde para Idosos/organização & administração , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...