Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Contraception ; 99(4): 244-250, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30685285

RESUMO

OBJECTIVE: With the widespread use of sex-steroid hormones in contraceptives and hormone replacement therapy, there is an increasing need for reliable analytical methods. We report the development of a sensitive and robust UPLC-MS/MS method for quantitation of both endogenous and synthetic sex-steroid hormones in human serum. STUDY DESIGN: We developed and validated a UPLC-MS/MS method to quantify progestogens (etonogestrel, levonorgestrel, medroxyprogesterone acetate, norethindrone, progesterone) and estrogens (estradiol and ethinyl estradiol) with good accuracy, high sensitivity, and excellent robustness. We then applied the method to the analysis of sex-steroid hormones in serum from 451 clinical research participants. RESULTS: Each UPLC-MS/MS analysis was 6.5 min. The lower limits of quantitation (LLOQs) were 25 pg/ml for the progestogens, and 2.5 and 5.0 pg/ml for estradiol and ethinyl estradiol, respectively. When estradiol was analyzed without assessment of progestogens, the LLOQ was reduced to 1 pg/ml. The calibration curves were linear from 25-50,000, 2.5-2000 (1-2000 for estrogens-only analysis) and 5-2000 pg/ml, respectively. Both the accuracy and precision were below±15% not only for routine validation (intraday and interday), but for long-term (>2 years) assay robustness with external controls, thereby, demonstrating the utility of this method for multi-year clinical trial assessments of progestogens and estrogens. We applied the method to quantify sex-steroid levels in 1804 clinical samples. CONCLUSIONS: We successfully developed a UPLC-MS/MS method, and overcame the matrix suppression to allow sensitive quantitation of both synthetic and endogenous sex-steroid hormones in human serum. IMPLICATIONS: We developed a sensitive and robust UPLC-MS/MS method to accurately measure the levels of sex-steroid hormones in serum. The method overcame matrix interference barriers and achieved excellent long-term stability and reproducibility (≥96.9% accuracy; ≤13.0% relative variability measured with external controls over 2 years), demonstrating its utility in clinical sample analysis.


Assuntos
Cromatografia Líquida/métodos , Estrogênios/sangue , Espectrometria de Massas/métodos , Progestinas/sangue , Humanos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA