Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 41(6): 1037-1042, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32467183

RESUMO

BACKGROUND AND PURPOSE: The Neuroform Atlas is a new microstent to assist coil embolization of intracranial aneurysms that recently gained FDA approval. We present a postmarket multicenter analysis of the Neuroform Atlas stent. MATERIALS AND METHODS: On the basis of retrospective chart review from 11 academic centers, we analyzed patients treated with the Neuroform Atlas after FDA exemption from January 2018 to June 2019. Clinical and radiologic parameters included patient demographics, aneurysm characteristics, stent parameters, complications, and outcomes at discharge and last follow-up. RESULTS: Overall, 128 aneurysms in 128 patients (median age, 62 years) were treated with 138 stents. Risk factors included smoking (59.4%), multiple aneurysms (27.3%), and family history of aneurysms (16.4%). Most patients were treated electively (93.7%), and 8 (6.3%) underwent treatment within 2 weeks of subarachnoid hemorrhage. Previous aneurysm treatment failure was present in 21% of cases. Wide-neck aneurysms (80.5%), small aneurysm size (<7 mm, 76.6%), and bifurcation aneurysm location (basilar apex, 28.9%; anterior communicating artery, 27.3%; and middle cerebral artery bifurcation, 12.5%) were common. A single stent was used in 92.2% of cases, and a single catheter for both stent placement and coiling was used in 59.4% of cases. Technical complications during stent deployment occurred in 4.7% of cases; symptomatic thromboembolic stroke, in 2.3%; and symptomatic hemorrhage, in 0.8%. Favorable Raymond grades (Raymond-Roy occlusion classification) I and II were achieved in 82.9% at discharge and 89.5% at last follow-up. mRS ≤2 was determined in 96.9% of patients at last follow-up. The immediate Raymond-Roy occlusion classification grade correlated with aneurysm location (P < .0001) and rupture status during treatment (P = .03). CONCLUSIONS: This multicenter analysis provides a real-world safety and efficacy profile for the treatment of intracranial aneurysms with the Neuroform Atlas stent.


Assuntos
Prótese Vascular , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Vigilância de Produtos Comercializados , Stents , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
2.
Acta Neurochir (Wien) ; 157(7): 1125-9; discussion 1130, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25981434

RESUMO

BACKGROUND: The use of minimally porous endoluminal devices (MPEDs) such as the Pipeline Embolization Device (PED) has been described for the treatment of brain aneurysms. The benefit of using MPEDs to assist embolization of a direct high-flow carotid cavernous fistula resulting from a ruptured cavernous carotid artery aneurysm is not well documented. METHODS: We describe our experience with deploying a tailored multidevice PED construct across the cavernous internal carotid artery (ICA) wall defect in combination with transarterial coil embolization using the "jailed microcatheter" technique. RESULTS: A 59-year-old woman presented with acute left-sided ophthalmoplegia. Diagnostic cerebral angiography demonstrated a ruptured giant cavernous carotid aneurysm with fistulous outflow via the ipsilateral left superior ophthalmic vein and into the pterygoid venous plexi bilaterally. Via the Marksman microcatheter, a total of three PEDs measuring 4.5 mm × 18 mm, 4.5 mm × 20 mm, and 4.75 mm × 16 mm were telescoped within the ICA across the aneurysm neck. Coiling of the aneurysm fundus and cavernous sinus via the "jailed" Rapidtransit microcatheter was subsequently achieved. A 2-year follow-up digital subtraction angiography (DSA) demonstrated stable obliteration of the aneurysm and the fistula, coincident with complete resolution of the patient's symptoms. CONCLUSIONS: Based on our long-term clinical and angiographic results, we advocate that the presented method be a valid treatment option for selected cases.


Assuntos
Prótese Vascular , Fístula Carótido-Cavernosa/cirurgia , Embolização Terapêutica/métodos , Dispositivos de Acesso Vascular , Aneurisma Roto/complicações , Aneurisma Roto/cirurgia , Fístula Carótido-Cavernosa/etiologia , Embolização Terapêutica/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade
3.
AJNR Am J Neuroradiol ; 36(5): 937-42, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25572948

RESUMO

BACKGROUND AND PURPOSE: Endoluminal reconstruction with the Pipeline Embolization Device is an effective treatment option for select intracranial aneurysms. However, concerns for the patency of eloquent branch arteries covered by the Pipeline Embolization Device have been raised. We aimed to examine the patency of the anterior choroidal artery and clinical sequelae after ICA aneurysm treatment. MATERIALS AND METHODS: We prospectively analyzed all patients among our first 157 patients with ICA aneurysms treated by the Pipeline Embolization Device who required placement of at least 1 device across the ostium of the anterior choroidal artery. The primary outcome measure was angiographic patency of the anterior choroidal artery at last follow-up. Age, sex, type of aneurysm, neurologic examination data, number of Pipeline Embolization Devices used, relationship of the anterior choroidal artery to the aneurysm, and completeness of aneurysm occlusion on follow-up angiograms were also analyzed. RESULTS: Twenty-nine aneurysms requiring placement of at least 1 Pipeline Embolization Device (median = 1, range = 1-3) across the anterior choroidal artery ostium were identified. At angiographic follow-up (mean = 15.1 months; range = 12-39 months), the anterior choroidal artery remained patent, with antegrade flow in 28/29 aneurysms (96.5%), while 24/29 (82.7%) of the target aneurysms were angiographically occluded by 1-year follow-up angiography. Anterior choroidal artery occlusion, with retrograde reconstitution of the vessel, was noted in a single case. A significant correlation between the origin of the anterior choroidal artery from the aneurysm dome and failure of the aneurysms to occlude following treatment was found. CONCLUSIONS: After placement of 36 Pipeline Embolization Devices across 29 anterior choroidal arteries (median = 1 device, range = 1-3 devices), 1 of 29 anterior choroidal arteries was found occluded on angiographic follow-up. The vessel occlusion did not result in persistent clinical sequelae. Coverage of the anterior choroidal artery origin with the Pipeline Embolization Device, hence, may be considered reasonably safe when deemed necessary for aneurysm treatment.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Grau de Desobstrução Vascular , Adulto , Idoso , Angiografia Cerebral , Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/cirurgia , Embolização Terapêutica/instrumentação , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
4.
AJNR Am J Neuroradiol ; 35(12): 2334-40, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25147199

RESUMO

BACKGROUND AND PURPOSE: Recent techniques of endoluminal reconstruction with flow-diverting stents have not been incorporated into treatment algorithms for cavernous carotid aneurysms. This study examines the authors' institutional experience and a systematic review of the literature for outcomes and complications using the Pipeline Embolization Device in unruptured cavernous carotid aneurysms. MATERIALS AND METHODS: A retrospective search for cavernous carotid aneurysms from a prospectively collected data base of aneurysms treated with the Pipeline Embolization Device at our institution was performed. Baseline demographic, clinical, and laboratory values; intrainterventional data; and data at all follow-up visits were collected. A systematic review of the literature for complication data was performed with inquiries sent when clarification of data was needed. RESULTS: Forty-three cavernous carotid aneurysms were included in the study. Our mean radiographic follow-up was 2.05 years. On last follow-up, 88.4% of the aneurysms treated had complete or near-complete occlusion. Aneurysm complete or near-complete occlusion rates at 6 months, 12 months, and 36 months were 81.4%, 89.7%, and 100%, respectively. Of patients with neuro-ophthalmologic deficits on presentation, 84.2% had improvement in their visual symptoms. Overall, we had a 0% mortality rate and a 2.3% major neurologic complication rate. Our systematic review of the literature yielded 227 cavernous carotid aneurysms treated with the Pipeline Embolization Device with mortality and morbidity rates of 0.4% and 3.1%, respectively. CONCLUSIONS: Endoluminal reconstruction with flow diversion for large unruptured cavernous carotid aneurysms can yield high efficacy with low complications. Further long-term data will be helpful in assessing the durability of the cure; however, we advocate a revisiting of current management paradigms for cavernous carotid aneurysms.


Assuntos
Doenças das Artérias Carótidas/terapia , Embolização Terapêutica/métodos , Aneurisma Intracraniano/terapia , Adulto , Idoso , Angiografia , Artéria Carótida Interna/diagnóstico por imagem , Embolização Terapêutica/instrumentação , Feminino , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...