Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
1.
Nat Med ; 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760584

RESUMO

Clinical outcomes of catheter ablation for atrial fibrillation (AF) are suboptimal due, in part, to challenges in achieving durable lesions. Although focal point-by-point ablation allows for the creation of any required lesion set, this strategy necessitates the generation of contiguous lesions without gaps. A large-tip catheter, capable of creating wide-footprint ablation lesions, may increase ablation effectiveness and efficiency. In a randomized, single-blind, non-inferiority trial, 420 patients with persistent AF underwent ablation using a large-tip catheter with dual pulsed field and radiofrequency energies versus ablation using a conventional radiofrequency ablation system. The primary composite effectiveness endpoint was evaluated through 1 year and included freedom from acute procedural failure and repeat ablation at any time, plus arrhythmia recurrence, drug initiation or escalation or cardioversion after a 3-month blanking period. The primary safety endpoint was freedom from a composite of serious procedure-related or device-related adverse events. The primary effectiveness endpoint was observed for 73.8% and 65.8% of patients in the investigational and control arms, respectively (P < 0.0001 for non-inferiority). Major procedural or device-related complications occurred in three patients in the investigational arm and in two patients in the control arm (P < 0.0001 for non-inferiority). In a secondary analysis, procedural times were shorter in the investigational arm as compared to the control arm (P < 0.0001). These results demonstrate non-inferior safety and effectiveness of the dual-energy catheter for the treatment of persistent AF. Future large-scale studies are needed to gather real-world evidence on the impact of the focal dual-energy lattice catheter on the broader population of patients with AF. ClinicalTrials.gov identifier: NCT05120193 .

2.
J Cardiovasc Electrophysiol ; 34(3): 693-699, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640426

RESUMO

INTRODUCTION: Contact force has been used to titrate lesion formation for radiofrequency ablation. Pulsed field ablation (PFA) is a field-based ablation technology for which limited evidence on the impact of contact force on lesion size is available. METHODS: Porcine hearts (n = 6) were perfused using a modified Langendorff set-up. A prototype focal PFA catheter attached to a force gauge was held perpendicular to the epicardium and lowered until contact was made. Contact force was recorded during each PFA delivery. Matured lesions were cross-sectioned, stained, and the lesion dimensions measured. RESULTS: A total of 82 lesions were evaluated with contact forces between 1.3 and 48.6 g. Mean lesion depth was 4.8 ± 0.9 mm (standard deviation), mean lesion width was 9.1 ± 1.3 mm, and mean lesion volume was 217.0 ± 96.6 mm3 . Linear regression curves showed an increase of only 0.01 mm in depth (depth = 0.01 × contact force + 4.41, R2 = 0.05), 0.03 mm in width (width = 0.03 × contact force + 8.26, R2 = 0.13) for each additional gram of contact force, and 2.20 mm3 in volume (volume = 2.20 × contact force + 162, R2 = 0.10). CONCLUSION: Increasing contact force using a bipolar, biphasic focal PFA system has minimal effects on acute lesion dimensions in an isolated porcine heart model and achieving tissue contact is more important than the force with which that contact is made.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Suínos , Animais , Ablação por Cateter/métodos , Ablação por Radiofrequência/métodos , Pericárdio , Catéteres , Irrigação Terapêutica
3.
Am Heart J ; 259: 30-41, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36642226

RESUMO

BACKGROUND: The impact of using direct-to-consumer wearable devices as a means to timely detect atrial fibrillation (AF) and to improve clinical outcomes is unknown. METHODS: Heartline is a pragmatic, randomized, and decentralized application-based trial of US participants aged ≥65 years. Two randomized cohorts include adults with possession of an iPhone and without a history of AF and those with a diagnosis of AF taking a direct oral anticoagulant (DOAC) for ≥30 days. Participants within each cohort are randomized (3:1) to either a core digital engagement program (CDEP) via iPhone application (Heartline application) and an Apple Watch (Apple Watch Group) or CDEP alone (iPhone-only Group). The Apple Watch Group has the watch irregular rhythm notification (IRN) feature enabled and access to the ECG application on the Apple Watch. If an IRN notification is issued for suspected AF then the study application instructs participants in the Apple Watch Group to seek medical care. All participants were "watch-naïve" at time of enrollment and have an option to either buy or loan an Apple Watch as part of this study. The primary end point is time from randomization to clinical diagnosis of AF, with confirmation by health care claims. Key secondary endpoint are claims-based incidence of a 6-component composite cardiovascular/systemic embolism/mortality event, DOAC medication use and adherence, costs/health resource utilization, and frequency of hospitalizations for bleeding. All study assessments, including patient-reported outcomes, are conducted through the study application. The target study enrollment is approximately 28,000 participants in total; at time of manuscript submission, a total of 26,485 participants have been enrolled into the study. CONCLUSION: The Heartline Study will assess if an Apple Watch with the IRN and ECG application, along with application-facilitated digital health engagement modules, improves time to AF diagnosis and cardiovascular outcomes in a real-world environment. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04276441.


Assuntos
Fibrilação Atrial , Embolia , Tromboembolia , Adulto , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Hemorragia
4.
J Cardiovasc Electrophysiol ; 34(2): 257-267, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36378803

RESUMO

BACKGROUND: Implantable cardioverter defibrillators (ICD) are indicated for primary and secondary prevention of sudden cardiac arrest. Despite enhancements in design and technologies, the ICD lead is the most vulnerable component of the ICD system and failure of ICD leads remains a significant clinical problem. A novel, small-diameter, lumenless, catheter-delivered, defibrillator lead was developed with the aim to improve long-term reliability. METHODS AND RESULTS: The Lead Evaluation for Defibrillation and Reliability (LEADR) study is a multi-center, single-arm, Bayesian, adaptive design, pre-market interventional pivotal clinical study. Up to 60 study sites from around the world will participate in the study. Patients indicated for a de novo ICD will undergo defibrillation testing at implantation and clinical assessments at baseline, implant, pre-hospital discharge, 3 months, 6 months, and every 6 months thereafter until official study closure. Patients may be participating for a minimum of 18 months to approximately 3 years. Fracture-free survival will be evaluated using a Bayesian statistical method that incorporates both virtual patient data (combination of bench testing to failure with in-vivo use condition data) with clinical patients. The clinical subject sample size will be determined using decision rules for number of subject enrollments and follow-up time based upon the observed number of fractures at certain time points in the study. The adaptive study design will therefore result in a minimum of 500 and a maximum of 900 patients enrolled. CONCLUSION: The LEADR Clinical Study was designed to efficiently provide evidence for short- and long-term safety and efficacy of a novel lead design using Bayesian methods including a novel virtual patient approach.


Assuntos
Desfibriladores Implantáveis , Parada Cardíaca , Humanos , Teorema de Bayes , Reprodutibilidade dos Testes , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 34(1): 54-61, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36259719

RESUMO

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) is frequently used for the purpose of rhythm control and improved quality of life (QoL). Although success rates are high, a significant proportion of patients require redo ablation. Data are scarce on patient-centered outcomes and QoL in patients undergoing redo AF ablation. We aimed to assess QoL and clinical outcomes using a large prospectively maintained patient-reported outcomes (PRO) registry. METHODS: All patients undergoing redo AF ablation (2013-2016) at our center were enrolled in a prospective registry for outcomes and assessed for QoL using automated PRO surveys (baseline, 3 and 6 months after ablation, every 6 months thereafter). Data were collected over 3 years of follow-up. The atrial fibrillation symptom severity scale (AFSSS) was used as the main measure for QoL. Additional variables included patient-reported improvement, AF burden, and AF-related healthcare utilization including emergency room (ER) visits and hospitalizations. RESULTS: A total of 848 patients were included (28% females, mean age 63.8, 51% persistent AF). By automated PRO, significant improvement in QoL was noted (baseline median AFSSS of 12 [5-18] and ranged between 2 and 4 on subsequent assessments; p < .0001), with ≥70%of patients reported remarkable improvement in their AF-related symptoms. The proportion of patients in AF at the time of baseline survey was 36%, and this decreased to <8% across all time points during follow-up (p < .0001). AF burden was significantly reduced (including frequency and duration of episodes; p < .0001), with an associated decrease in healthcare utilization after 6 months from the time of ablation (including ER visits and hospitalizations; p < .0001). The proportion of patients on anticoagulants or antiarrhythmics decreased on follow-up across all time points (p < .0001 for all variables). CONCLUSION: Most patients derive significant QoL benefit from redo AF ablation; with reduction of both AF burden and healthcare utilization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Feminino , Humanos , Pessoa de Meia-Idade , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Qualidade de Vida , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Ablação por Cateter/efeitos adversos , Medidas de Resultados Relatados pelo Paciente
6.
Heart Rhythm O2 ; 3(5): 466-473, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36340491

RESUMO

Background: Implant site hematoma is a known complication of cardiac device procedures and can lead to major consequences. Objectives: To evaluate risk factors for hematoma and further understand the relationship between anticoagulant (AC), antiplatelet (AP) use, and hematoma development. Methods: We included 6800 patients from the WRAP-IT trial. To assess baseline and procedural characteristics associated with hematoma within the first 30 days postprocedure, a stepwise Cox regression model was implemented with minimal Akaike information criterion. Cox regressions were also used to evaluate AC/AP use and hematoma risk. Results: The overall rate of hematoma was 2.2%. The model identified 11 baseline and procedural characteristics associated with hematoma risk. AC use (hazard ratio [HR]: 2.44, P < .001), lower body mass index (HR: 1.06, P < .001), and history of valve surgery (HR: 2.11, P < .001) were associated with the highest risk. AP use, male sex, history of coronary artery disease, existing pocket, history of nonischemic cardiomyopathy, number of previous cardiac implantable electronic device (CIED) procedures, procedure time, and lead revision were associated with moderate risk. Antithrombotic use was high overall (86%) and AC+AP use was highly predictive of hematoma risk. Regardless of AC status, AP use was associated with an almost doubling of risk vs no AP (HR = 1.85, P = .0006) in the general cohort. Interruption of AC was associated with the lowest hematoma risk (HR = 2.35) while heparin bridging (HR = 4.98) and AP use vs no AP use (HR = 1.85) was associated with the highest hematoma risk. Conclusion: The results of this analysis highlight risk factors associated with the development of hematoma in patients undergoing CIED procedures and can inform antithrombotic management.

7.
Circ Arrhythm Electrophysiol ; 15(11): e010779, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36306341

RESUMO

BACKGROUND: Difficulty of lead extraction does not track well with procedural complications, but several small retrospective studies have lead fibrosis on computed tomography as an important indicator of difficult lead extraction. The purpose of the present study was to apply a standardized gated cardiac computed tomography (CT) protocol to assess fibrosis and study it prospectively to examine the need for powered sheaths and risk outcomes. METHODS: We performed a prospective, blinded, multicenter, international study at high-volume lead extraction centers and included patients referred for transvenous lead extraction with at least one lead with a dwell time >1 year and ability to receive a cardiac CT. The degree of fibrosis (as measured by amount of lead adherence to vessel wall) was graded on a scale of 1 to 4 by dedicated CT readers in 3 zones (vein entry to superior vena cava, superior vena cava, and right atrium to lead tip). The primary outcome of the study was number of extractions requiring powered sheaths at zone 2 for each fibrosis group. RESULTS: A total of 200 patients were enrolled in the trial with 196 completing full gated CT and lead extraction analysis. The primary endpoint of powered sheath (laser and mechanical) sheath use was significantly higher in patients with higher fibrosis seen on CT (scores 3+4; 67.8%) at the zone 2 compared to patients with lower fibrosis (scores 1+2; 38.6%; P<0.001). There were 5 major complications with 3 vascular lacerations all occurring in zone 2 in the study. CONCLUSIONS: Gated, contrasted CT can predict the need for powered sheaths by identification of fibrosis but did not identify an absolute low-risk cohort who would not need powered sheaths. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03772704.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Veia Cava Superior , Estudos Retrospectivos , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Fibrose
8.
Eur Heart J Open ; 2(2): oeac014, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35919121

RESUMO

Aims: The 2021 European Society of Cardiology guidelines recommend early pacemaker implantation in pre-existing right bundle branch block (RBBB) patients who develop PR prolongation or QRS axis change after transcatheter aortic valve implantation (TAVI). We aimed to evaluate this recommendation in TAVI recipients with a balloon-expandable valve (BEV). Methods and results: We retrospectively reviewed 188 pre-existing RBBB patients without pre-existing permanent pacemaker (PPM) who underwent TAVI with a BEV at our institution in 2015-19. Patients who developed high-degree atrioventricular block (HAVB) during TAVI or within 24 h post-TAVI were excluded. Eligible patients were divided according to the guideline-directed criteria (ΔPR interval ≥20 ms and/or QRS axis change). Patients who met the criteria (n = 102, 54.3%), compared with those who did not (n = 86), had a higher prevalence of baseline right axis deviation and were more likely to have received a larger valve with greater oversizing. The 30-day delayed HAVB rate did not differ significantly between the groups (3.9% vs. 4.7%, P = 1.00; odds ratio = 0.84, 95% confidence interval = 0.20-3.45). There was also no significant difference in terms of death (5.0% vs. 8.4% at 1 year; overall log-rank P = 0.94) or a composite of death or PPM implantation (14.8% vs. 16.6% at 1 year; overall log-rank P = 0.94) during follow-up post-TAVI. The majority of PR prolongations (79.4%) and QRS axis changes (52.0%) regressed within the following 24 h. Conclusion: The present data did not demonstrate an association of significant changes in PR interval or QRS axis with heightened delayed HAVB risk in BEV recipients with pre-existing RBBB. Prospective studies are warranted to confirm these findings.

9.
J Cardiovasc Electrophysiol ; 33(9): 1994-2000, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35689504

RESUMO

INTRODUCTION: Pulmonary venous (PV) electrical recovery underlies most arrhythmia recurrences after atrial fibrillation (AF) ablation. Little is known about procedural profiles and outcomes of patients with electrically silent PVs upon redo ablation for AF. METHODS: In a prospectively maintained registry, we enrolled 838 consecutive patients (2013-2016) undergoing redo ablation procedures. Ablation procedures targeted the PVs, the PV antra, and non-PV sites at operators' discretion. Procedural profiles and clinical outcomes were assessed. The primary outcome was freedom from AF after a 3-month blanking period. The secondary outcome was improvement in quality of life. RESULTS: Most patients undergoing redo AF ablation (n = 684, 82%) had PV reconnection while the remaining 154 (18%) had electrically silent PVs. Patients with recurrent AF and electrically silent PVs were older (66 vs. 64 years, p = .02), had more prior ablation procedures (median 2 IQR 1-3 vs 1 IQR 1-2 p = .001), were more likely to have non-paroxysmal AF (62% vs. 49%, p = .004) and atrial flutter (48% vs. 29%, p = .001) and had significantly larger left atrial volumes (89 vs. 81 ml, p = .003). Patients with silent PVs underwent a more extensive non-PV ablation strategies with antral extension of prior ablation sets in addition to ablation of the roof, appendage, inferior to the right PVs, peri-mitral flutter lines, cavotricuspid isthmus lines and ablation in the coronary sinus. Upon one year of follow-up, patients with electrically silent PVs were less likely to remain free from recurrent atrial arrhythmias (64% vs. 76%, p = .008). Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. CONCLUSION: Rhythm control with extensive ablation allowed maintenance of sinus rhythm in about two thirds of patients with silent PVs during redo AF ablation procedures. Regardless of PV reconnection status, redo ablation resulted in improvement in quality of life. This remains a challenging group of patients, highlighting the need to better understand non-PV mediated AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Veias Pulmonares/cirurgia , Qualidade de Vida , Recidiva , Resultado do Tratamento
10.
JACC Clin Electrophysiol ; 8(4): 498-510, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35450605

RESUMO

OBJECTIVES: This study sought to examine the effect of the return electrode's surface area on bipolar RFA lesion size. BACKGROUND: Bipolar radiofrequency ablation (RFA) is typically performed between 2 3.5-mm tip catheters serving as active and return electrodes. We hypothesized that increasing the surface area of the return electrode would increase lesion dimensions by reducing the circuit impedance, thus increasing the current into a larger tissue volume enclosed between the electrodes. METHODS: In step 1, ex vivo bipolar RFA was performed between 3.5-mm and custom-made return electrodes with increasing surface areas (20, 80, 180 mm2). In step 2, ex vivo bipolar RFA was performed between 3.5-mm and 3.5-mm or 8-mm electrode catheters positioned perpendicular or parallel to the tissue. In step 3, in vivo bipolar RFA was performed between 3.5-mm and either 3.5-mm or 8-mm parallel electrode at the: 1) left ventricular summit; 2) interventricular septum; and 3) healed anterior infarction. RESULTS: In step 1, increasing the surface area of the return electrode resulted in lower circuit impedance (R = -0.65; P < 0.001), higher current (R = +0.80; P < 0.001), and larger lesion volume (R = +0.88; P < 0.001). In step 2, an 8-mm return electrode parallel to tissue produced larger and deeper lesions compared with a 3.5-mm return electrode (P = 0.014 and P = 0.02). Similarly, in step 3, compared with a 3.5-mm, bipolar RFA with an 8-mm return electrode produced larger (volume: 1,525 ± 871 mm3 vs 306 ± 310 mm3, respectively; P < 0.001) and more transmural lesions (88% vs 0%; P < 0.001). CONCLUSIONS: Bipolar RFA using an 8-mm return electrode positioned parallel to the tissue produces larger lesions in comparison with a 3.5-mm return electrode.


Assuntos
Ablação por Cateter , Ablação por Cateter/métodos , Eletrodos , Desenho de Equipamento , Ventrículos do Coração/cirurgia , Humanos
11.
Am J Cardiol ; 168: 117-127, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35045936

RESUMO

New-onset left bundle branch block (LBBB) is common after transcatheter aortic valve implantation (TAVI) but can resolve in the post-TAVI period. We sought to examine the incidence, predictors, and outcomes of early resolution of new-onset LBBB among TAVI recipients with a SAPIEN 3 (S3) valve. Among 1,203 S3-TAVI recipients without a pre-existing pacemaker or wide QRS complex at our institution between 2016 and 2019, we identified 143 patients who developed new-onset LBBB during TAVI and divided them according to the resolution or persistence of LBBB by the next day post-TAVI to compare high-degree atrioventricular block (HAVB) and permanent pacemaker (PPM) rates. Patients with resolved LBBB (n = 74, 52%), compared with those with persistent LBBB, were more often women and had a shorter QRS duration at baseline and post-TAVI, with a smaller S3 size and a shallower implantation depth. A multivariable logistic regression model demonstrated significant associations of post-TAVI QRS duration (per 10 ms increase, odds ratio = 0.60 [95% confidence interval = 0.44 to 0.82]) and implantation depth (per 1-mm-depth-increase, 0.77 [0.61 to 0.97]) with a lower likelihood of LBBB resolution. No patient with resolved LBBB developed HAVB within 30 days post-TAVI. Meanwhile, 8 patients (11.6%) with persistent LBBB developed HAVB. The 2-year PPM rate was significantly higher after persistent LBBB than after resolved LBBB (30.3% vs 4.5%, log-rank p <0.001), mainly driven by higher 30-day PPM rate (18.8% vs 0.0%). In conclusion, about half of new-onset LBBBs that occurred during S3-TAVI resolved by the next day post-TAVI without HAVB. In contrast, new-onset persistent LBBB may need follow-up with ambulatory monitoring within 30 days because of the HAVB risk.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Arritmias Cardíacas/complicações , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/terapia , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
JACC Clin Electrophysiol ; 8(1): 101-111, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34600848

RESUMO

OBJECTIVES: This study aimed to identify risk factors for infection after secondary cardiac implantable electronic device (CIED) procedures. BACKGROUND: Risk factors for CIED infection are not well defined and techniques to minimize infection lack supportive evidence. WRAP-IT (World-wide Randomized Antibiotic Envelope Infection Prevention trial), a large study that assessed the safety and efficacy of an antibacterial envelope for CIED infection reduction, offers insight into procedural details and infection prevention strategies. METHODS: This analysis included 2,803 control patients from the WRAP-IT trial who received standard preoperative antibiotics but not the envelope (44 patients with major infections through all follow-up). A multivariate least absolute shrinkage and selection operator machine learning model, controlling for patient characteristics and procedural variables, was used for risk factor selection and identification. Risk factors consistently retaining predictive value in the model (appeared >10 times) across 100 iterations of imputed data were deemed significant. RESULTS: Of the 81 variables screened, 17 were identified as risk factors with 6 being patient/device-related (nonmodifiable) and 11 begin procedure-related (potentially modifiable). Patient/device-related factors included higher number of previous CIED procedures, history of atrial arrhythmia, geography (outside North America and Europe), device type, and lower body mass index. Procedural factors associated with increased risk included longer procedure time, implant location (non-left pectoral subcutaneous), perioperative glycopeptide antibiotic versus nonglycopeptide, anticoagulant, and/or antiplatelet use, and capsulectomy. Factors associated with decreased risk of infection included chlorhexidine skin preparation and antibiotic pocket wash. CONCLUSIONS: In WRAP-IT patients, we observed that several procedural risk factors correlated with infection risk. These results can help guide infection prevention strategies to minimize infections associated with secondary CIED procedures.


Assuntos
Desfibriladores Implantáveis , Infecções Relacionadas à Prótese , Antibioticoprofilaxia , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Humanos , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/prevenção & controle , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco
13.
Heart Rhythm ; 19(3): 363-371, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34767985

RESUMO

BACKGROUND: Implantable cardioverter-defibrillator (ICD) lead monitoring diagnostic alerts facilitate the diagnosis of structural lead failure. OBJECTIVE: The purpose of this study was to prospectively study the performance of Medtronic ICD lead monitoring alerts. METHODS: A prespecified ancillary substudy, World-Wide Randomized Antibiotic Envelope Infection Prevention Trial, was conducted in patients with an ICD with all available alerts enabled. The investigators reported possible lead system events (LSEs), with or without an alert. An independent committee reviewed all data and classified events as lead failure, other LSE, or nonlead system events (NLEs). RESULTS: In 4942 patients who were followed for 19.4 ± 8.7 months, there were 124 alerts (65 LSEs, 59 NLEs) and 19 LSEs without an alert. Lead monitoring alerts had 100% sensitivity for the 48 adjudicated lead failures (95% confidence interval 92.6%-100%) and for 10 events adjudicated as either lead failure or connection issue. The positive predictive value of alerts for lead failure was 38.7% (48 of 124). For 34 pace-sense lead failures, an alert that incorporated oversensing was more sensitive than the pacing impedance threshold alert (33 patients [97.1%] vs 9 patients [26.5%]; P < .0001). However, the sensitivity was only 13.6% for lead dislodgments or perforations. Inappropriate shocks occurred in 2 patients with pace-sense lead failure (5.9%). No patient had unnecessary lead replacement for any of the NLEs. CONCLUSION: In this first real-world prospective study, lead monitoring alerts had 100% sensitivity for identifying lead failures. Although their positive predictive value was modest, no false-positive alerts resulted in an unnecessary lead replacement. For the diagnosis of pace-sense lead failure, an alert for oversensing was more sensitive than a pacing impedance threshold alert. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT02277990.


Assuntos
Desfibriladores Implantáveis , Desfibriladores Implantáveis/efeitos adversos , Impedância Elétrica , Falha de Equipamento , Humanos , Valor Preditivo dos Testes , Estudos Prospectivos
14.
Heart Rhythm ; 19(3): 381-388, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34801735

RESUMO

BACKGROUND: Bradyarrhythmias leading to permanent pacemaker (PPM) implantation continue to be a complication after transcatheter aortic valve replacement (TAVR). OBJECTIVE: The purpose of this study was to assess the prevalence of bradyarrhythmias using an electrocardiographic (ECG) extended rhythm recording in patients pre- and post-TAVR and whether they can predict the need for PPM. METHODS: This was a prospective single-center study in patients undergoing TAVR. Patients received an ECG patch for 2 weeks pre-, immediately post-, and 2-3 months post-TAVR. Caring physicians were blinded to the results of the patch except when predefined urgent arrhythmias were detected. The main outcome was the need for PPM implantation after TAVR. RESULTS: We enrolled 110 patients, of whom 96 underwent TAVR and were included in the final analysis. Bradyarrhythmias, defined as a pause of 3 seconds or more, occurred in 5.2%, 12.7%, and 7% of patients pre-, immediately post-, and 2-3 months post-TAVR, respectively. PPM implantation occurred in 12 patients (12.5%), of whom 9 (9.4%) underwent implantation during their index hospitalization while 3 (3.1%) required implantation postdischarge for indications other than heart block. No patients required PPM after receiving an ECG patch 2-3 months post-TAVR. Significant baseline predictors for the need for PPM included the presence of right bundle branch block and increased QRS duration. Bradyarrhythmias detected by the ECG patch did not predict the need for PPM at either the index hospitalization or the follow-up period. CONCLUSION: Bradyarrhythmias are common and can be detected with extended ECG monitoring before and after TAVR; however, in our study they did not predict the need for PPM after TAVR (ClinicalTrials.gov identifier: NCT03180073).


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Bradicardia/diagnóstico , Bradicardia/epidemiologia , Bradicardia/etiologia , Eletrocardiografia , Humanos , Marca-Passo Artificial/efeitos adversos , Alta do Paciente , Estudos Prospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
Heart ; 108(4): 274-278, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34489312

RESUMO

INTRODUCTION: Chemotherapy-induced cardiomyopathy has been increasingly recognised as patients are living longer with more effective treatments for their malignancies. Anthracyclines are known to cause left ventricular (LV) dysfunction. While heart failure medications are frequently used, some patients may need consideration for device-based therapies such as cardiac resynchronisation therapy (CRT). However, the role of CRT in anthracycline-induced cardiomyopathy (AIC) is not well understood. METHODS: We performed a retrospective review of all patients undergoing CRT implantation at our centre from 2003 to 2019 with a diagnosis of AIC. The LV remodelling and survival outcomes of this population were obtained and then compared with consecutive patients with other aetiologies of non-ischaemic cardiomyopathy (NICM). RESULTS: A total of 34 patients underwent CRT implantation with a diagnosis of AIC with a mean age of 60.5±12.7 years, left ventricular ejection fraction (LVEF) of 21.7%±7.4%, and 11.3±7.5 years and 10.2±7.4 years from cancer diagnosis and last anthracycline exposure, respectively. At 9.6±8.1 months after CRT implantation, there was an increase of LVEF from 21.8%±7.6% to 30.4%±13.0% (p<0.001). Patients whose LVEF increased by at least 10% post-CRT implant (42.5% of cohort) survived significantly longer than patients who failed to improve their LVEF by that amount (p=0.01). A propensity matched analysis between patients with AIC and 369 consecutive patients with other aetiologies of NICM who underwent CRT implantation during the same period revealed no significant differences in improvement in LVEF or long-term survival. CONCLUSIONS: Patients with AIC undergo LV remodelling with CRT at rates similar to other aetiologies of NICM. Furthermore, AIC post-CRT responders have a favourable long-term mortality compared with non-responders.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias , Desfibriladores Implantáveis , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Idoso , Antraciclinas/efeitos adversos , Terapia de Ressincronização Cardíaca/efeitos adversos , Cardiomiopatias/induzido quimicamente , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/induzido quimicamente , Insuficiência Cardíaca/terapia , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/induzido quimicamente , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/terapia , Função Ventricular Esquerda , Remodelação Ventricular
16.
Struct Heart ; 6(3): 100019, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37274547

RESUMO

Background: In the absence of randomized data, an expert panel recently proposed an algorithm for conduction disturbance management in transcatheter aortic valve implantation (TAVI) recipients. However, external validations of its recommendations are limited. Methods: We retrospectively identified 808 patients without a pre-existing pacing device who underwent transfemoral TAVI with the Sapien 3 valve at our institution in 2018-2019. Patients were grouped based on pre-existing conduction disturbance and immediate post-TAVI electrocardiogram. Timing of temporary pacemaker (TPM) removal and hospital discharge were compared with those of the expert panel recommendations to evaluate the associated risk of TPM reinsertion and permanent pacemaker (PPM) implantation. Results: In most group 1 patients (no electrocardiogram changes without pre-existing right bundle branch block), the timing of TPM removal and discharge were concordant with those of the expert panel recommendations, with low TPM reinsertion (0.8%) and postdischarge PPM (0.8%) rates. In the majority of group 5 patients (procedural high-degree/complete atrioventricular block), TPM was maintained, followed by PPM implantation, compatible with the expert panel recommendations. In contrast, in groups 2-4 (pre-existing/new conduction disturbances), earlier TPM removal than recommended by the expert panel (mostly, immediately after procedure) was feasible in 97.5%-100% of patients, with a low TPM reinsertion rate (0.0%-1.8%); earlier discharge was also feasible in 50.0%-65.5%, with a low 30-day postdischarge PPM rate (0.0%-2.8%) and no 30-day death. Conclusions: Early TPM removal and discharge after TAVI appear safe and feasible in the majority of cases. These data may provide a framework for an early, streamlined hospital discharge plan for TAVI recipients, optimizing both cost savings and patient safety.

17.
Heart Rhythm O2 ; 2(5): 463-471, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34667961

RESUMO

BACKGROUND: High adherence to remote monitoring (RM) in pacemaker (PM) patients improves outcomes; however, adherence remains suboptimal. Bluetooth low-energy (BLE) technology in newer-generation PMs enables communication directly with patient-owned smart devices using an app without a bedside console. OBJECTIVE: To evaluate the success rate of scheduled RM transmissions using the app compared to other RM methods. METHODS: The BlueSync Field Evaluation was a prospective, international cohort evaluation, measuring the success rate of scheduled RM transmissions using a BLE PM or cardiac resynchronization therapy PM coupled with the MyCareLink Heart app. App transmission success was compared to 3 historical "control" groups from the Medtronic de-identified CareLink database: (1) PM patients with manual communication using a wand with a bedside console (PM manual transmission), (2) PM patients with wireless automatic communication with the bedside console (PM wireless); (3) defibrillator patients with similar automatic communication (defibrillator wireless). RESULTS: Among 245 patients enrolled (age 64.8±15.6 years, 58.4% men), 953 transmissions were scheduled through 12 months, of which 902 (94.6%) were successfully completed. In comparison, transmission success rates were 56.3% for PM manual transmission patients, 77.0% for PM wireless patients, and 87.1% for defibrillator wireless patients. Transmission success with the app was superior across matched cohorts based on age, sex, and device type (single vs dual vs triple chamber). CONCLUSION: The success rate of scheduled RM transmissions was higher among patients using the smart device app compared to patients using traditional RM using bedside consoles. This novel technology may improve patient engagement and adherence to RM.

18.
Circ Arrhythm Electrophysiol ; 14(11): e010205, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34706551

RESUMO

BACKGROUND: High-power short-duration (HP-SD) radiofrequency ablation (RFA) has been proposed as a method for producing rapid and effective lesions for pulmonary vein isolation. The underlying hypothesis assumes an increased resistive heating phase and decreased conductive heating phase, potentially reducing the risk for esophageal thermal injury. The objective of this study was to compare the esophageal temperature dynamic profile between HP-SD and moderate-power moderate-duration (MP-MD) RFA ablation strategies. METHODS: In patients undergoing pulmonary vein isolation, RFA juxtaposed to the esophagus was delivered in an alternate sequence of HP-SD (50 W, 8-10 s) and MP-MD (25 W, 15-20 s) between adjacent applications (distance, ≤4 mm). Esophageal temperature was recorded using a multisensor probe (CIRCA S-CATH). Temperature data included magnitude of temperature rise, maximal temperature, time to maximal temperature, and time return to baseline. In swine, a similar experimental design compared the effect of HP-SD and MP-MD on patterns of esophageal injury. RESULTS: In 20 patients (68.9±5.8 years old; 60% persistent atrial fibrillation), 55 paired HP-SD and MP-MD applications were analyzed. The esophageal temperature dynamic profile was similar between HP-SD and MP-MD ablation strategies. Specifically, the magnitude of temperature rise (2.1 °C [1.4-3] versus 2.0 °C [1.5-3]; P=0.22), maximal temperature (38.4 °C [37.8-39.3] versus 38.5 °C [37.9-39.4]; P=0.17), time to maximal temperature (24.9±7.5 versus 26.3±6.8 s; P=0.1), and time of temperature to return to baseline (110±23.2 versus 111±25.1 s; P=0.86) were similar between HP-SD and MP-MD ablation strategies. In 6 swine, esophageal injury was qualitatively similar between HP-SD and MP-MD strategies. CONCLUSIONS: Esophageal temperature dynamics are similar between HP-SD and MP-MD RFA strategies and result in comparable esophageal tissue injury. Therefore, when using a HP-SD RFA strategy, the shorter application duration should not prompt shorter intervals between applications.


Assuntos
Fibrilação Atrial/cirurgia , Temperatura Corporal/fisiologia , Ablação por Cateter/métodos , Esôfago/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Veias Pulmonares/cirurgia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Value Health ; 24(7): 930-938, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34243836

RESUMO

OBJECTIVES: To model the cost-effectiveness of the TYRX Absorbable Antibacterial Envelope when used in patients at increased risk of cardiac implantable electronic device (CIED) infection in the context of 3 European healthcare systems: Germany, Italy, and England. METHODS: A decision tree model with a lifetime horizon was populated using data from the Worldwide Randomized Antibiotic Envelope Infection Prevention Trial, a large multicenter randomized controlled trial. Use of the antibacterial envelope adjunctive to standard of care was compared to standard of care infection prevention alone. Patients in the model were divided into subgroups based on presence of factors known to increase infection risk. RESULTS: The antibacterial envelope had the most favorable cost-effectiveness profile when patients had previously experienced CIED infection, had a history of immunosuppressive therapy, or had a Prevention of Arrhythmia Device Infection Trial (PADIT) score indicating high risk of infection (scores ≥6) at cost-effectiveness thresholds of €50 000 in Germany (assumed in the absence of an official threshold), €40 000 in Italy, and £30 000 in England. Probabilistic sensitivity analysis indicated that the antibacterial envelope was likely to be cost-effective in patients with other risk factors (including replacement of high power CIEDs, generator replacement with lead modification, and PADIT scores indicating intermediate risk of infection) when used with some device types and in some countries. CONCLUSIONS: The absorbable antibacterial envelope was associated with cost-effectiveness ratios below European benchmarks in selected patients at increased risk of infection, suggesting the envelope provides value for European healthcare systems by reducing CIED infections.


Assuntos
Antibioticoprofilaxia/economia , Análise Custo-Benefício , Controle de Infecções , Marca-Passo Artificial/microbiologia , Árvores de Decisões , Europa (Continente) , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...