Arch. Soc. Esp. Oftalmol ; 98(9): 533-539, sept. 2023. ilus, tab
Artigo em Espanhol | IBECS | ID: ibc-224815

RESUMO

I ntroducción Este estudio analiza la comparabilidad de las medidas tomadas por un autorefractómetro portátil Retinomax K-plus 3 en modo Quick (rápido) y un autorrefractómetro de sobremesa Topcon KR-800 en modo estándar sobre la población pediátrica, y establece su correlación. Método Es un estudio comparativo retrospectivo. Se midieron las variables potencia dióptrica esférica (SPH), potencia dióptrica cilíndrica (CYL), ángulo del eje cilíndrico (AX) y equivalente esférico (SE) con el Retinomax en modo Quick y con el Topcon en modo estándar. Cada paciente fue evaluado en condiciones ciclopléjicas y no ciclopléjicas por ambos autorefractómetros. Se realizó la prueba t de Student entre ambos instrumentos para SPH, CYL y SE. Se calculó el coeficiente de correlación de Pearson y se representó la dispersión mediante gráficas de Bland-Altman, evaluándose también el subgrupo de pacientes menores de 4 años. Se realizó un análisis descriptivo de los porcentajes de medidas que diferían. Resultados Incluyó 98 ojos de 49 sujetos (rango de edad: 3-16 años). Los datos de SPH sin cicloplejia son prácticamente idénticos, mientras que con cicloplejia hay un sesgo hipermetrópico de +0,5 dioptrías medidas con Retinomax. Los resultados de CYL son muy similares con y sin cicloplejia. Existe una gran correlación de Pearson para ambos instrumentos (>0,91) y un bajo grado de dispersión en los gráficos de Bland-Altman bajo cicloplejia. Conclusión Los datos del Retinomax fueron consistentes con los obtenidos por el Topcon. El Retinomax es un instrumento útil para detectar errores de refracción en niños de entre 3 y 16 años (AU)


Introduction This study analyzes the comparability of measurements taken by a Retinomax K-plus 3 handheld autorefractometer in quick mode and a Topcon KR-800 on-table autorefractometer in standard mode on the pediatric population, and establishes their correlation. Methods It is a retrospective comparative study. Spherical diopter power (SPH), cylindrical diopter power (CYL), angle of cylindrical axis (AX), and spherical equivalent (SE) were measured with the Retinomax in quick mode and with the Topcon in standard mode. Each patient was evaluated in cycloplegic and non-cycloplegic conditions by both autorefractometers. Student's t-test was performed between the two instruments for SPH, CYL, and SE. The Pearson correlation coefficient was calculated and the dispersion was represented using Bland-Altman graphs, also evaluating the subgroup of patients under 4 years of age. A descriptive analysis of the percentages of measures that differed was performed. Results It included 98 eyes of 49 subjects (age range: 3-16 years). The data for HPS without cycloplegia are virtually identical, whereas with cycloplegia there is a hyperopic bias of +0.5 diopters measured with Retinomax. CYL results are very similar with and without cycloplegia. There is a high Pearson correlation for both instruments (>0.91) and a low degree of dispersion in the Bland-Altman plots under cycloplegia. Conclusion The Retinomax data were consistent with those obtained by Topcon. The Retinomax is a useful instrument for detecting refractive errors in children between 3 and 16 years of age (AU)


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Criança , Adolescente , Técnicas de Diagnóstico Oftalmológico/instrumentação , Erros de Refração/diagnóstico , Estudos Retrospectivos , Correlação de Dados
3.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(9): 533-539, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37595789

RESUMO

INTRODUCTION: This study analyzes the comparability of measurements taken by a Retinomax K-plus 3 handheld autorefractometer in Quick mode and a Topcon KR-800 on-table autorefractometer in standard mode on the pediatric population, and establishes their correlation. METHODS: It is a retrospective comparative study. Spherical diopter power (SPH), cylindrical diopter power (CYL), angle of cylindrical axis (AX), and spherical equivalent (SE) were measured with the Retinomax in Quick mode and with the Topcon in standard mode. Each patient was evaluated in cycloplegic and non-cycloplegic conditions by both autorefractometers. Student's t-test was performed between the two instruments for SPH, CYL, and SE. The Pearson correlation coefficient was calculated and the dispersion was represented using Bland-Altman graphs, also evaluating the subgroup of patients under 4 years of age. A descriptive analysis of the percentages of measures that differed was performed. RESULTS: It included 98 eyes of 49 subjects (age range: 3-16 years). The data for HPS without cycloplegia are virtually identical, whereas with cycloplegia there is a hyperopic bias of +0.5 diopters measured with Retinomax. CYL results are very similar with and without cycloplegia. There is a high Pearson correlation for both instruments (>0.91) and a low degree of dispersion in the Bland-Altman plots under cycloplegia. CONCLUSION: The Retinomax data were consistent with those obtained by Topcon. The Retinomax is a useful instrument for detecting refractive errors in children between 3 and 16 years of age.


Assuntos
Hiperopia , Presbiopia , Distúrbios Pupilares , Criança , Humanos , Pré-Escolar , Adolescente , Estudos Retrospectivos , Correlação de Dados , Olho , Midriáticos
4.
Arch. Soc. Esp. Oftalmol ; 98(4): 238-242, abr. 2023. ilus
Artigo em Espanhol | IBECS | ID: ibc-218548

RESUMO

El edema corneal y la disminución del recuento de células endoteliales son complicaciones relacionadas con la hipoxia crónica de bajo grado, que experimentan los usuarios de lentes de contacto, principalmente debido al uso prolongado y nocturno. Este caso muestra el ejemplo de un paciente que presenta problemas de visión borrosa en ambos ojos, y a quien se le realizó un examen oftalmológico completo que incluyó fotografías, topografía corneal y conteo de células endoteliales. Posteriormente se revisa el metabolismo corneal, la etiopatogenia y las complicaciones derivadas del uso de lentes de contacto (AU)


Corneal edema and decreased endothelial cell count are complications related to chronic low-grade hypoxia experienced by contact lens wearers, primarily due to prolonged and overnight wear. This case shows the example of a patient who has blurred vision problems in both eyes and who underwent a complete ophthalmologic examination that included photographs, corneal topography and endothelial cell count. Subsequently, the corneal metabolism, the etiopathogenesis and the complications derived from the use of contact lenses are reviewed (AU)


Assuntos
Humanos , Feminino , Idoso , Lentes de Contato de Uso Prolongado/efeitos adversos , Edema da Córnea/diagnóstico por imagem , Edema da Córnea/etiologia , Paquimetria Corneana
5.
Arch Soc Esp Oftalmol (Engl Ed) ; 98(4): 238-242, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36878285

RESUMO

Corneal edema and decreased endothelial cell count are complications related to chronic low-grade hypoxia experienced by contact lens wearers, primarily due to prolonged and overnight wear. This case shows the example of a patient who has blurred vision problems in both eyes and who underwent a complete ophthalmologic examination that included photographs, corneal topography and endothelial cell count. Subsequently, the corneal metabolism, the etiopathogenesis and the complications derived from the use of contact lenses are reviewed.


Assuntos
Lentes de Contato de Uso Prolongado , Lentes de Contato , Doenças da Córnea , Edema da Córnea , Humanos , Lentes de Contato de Uso Prolongado/efeitos adversos , Córnea , Doenças da Córnea/etiologia , Doenças da Córnea/terapia , Lentes de Contato/efeitos adversos , Edema da Córnea/etiologia