Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 11(3): e0150676, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27002333

RESUMO

Mobile technology is increasingly used to measure visual acuity. Standards for chart-based acuity tests specify photometric requirements for luminance, optotype contrast and luminance uniformity. Manufacturers provide some photometric data but little is known about tablet performance for visual acuity testing. This study photometrically characterised seven tablet computers (iPad, Apple inc.) and three ETDRS (Early Treatment Diabetic Retinopathy Study) visual acuity charts with room lights on and off, and compared findings with visual acuity measurement standards. Tablet screen luminance and contrast were measured using nine points across a black and white checkerboard test screen at five arbitrary brightness levels. ETDRS optotypes and adjacent white background luminance and contrast were measured. All seven tablets (room lights off) exceeded the most stringent requirement for mean luminance (≥ 120 cd/m2) providing the nominal brightness setting was above 50%. All exceeded contrast requirement (Weber ≥ 90%) regardless of brightness setting, and five were marginally below the required luminance uniformity threshold (Lmin/Lmax ≥ 80%). Re-assessing three tablets with room lights on made little difference to mean luminance or contrast, and improved luminance uniformity to exceed the threshold. The three EDTRS charts (room lights off) had adequate mean luminance (≥ 120 cd/m2) and Weber contrast (≥ 90%), but all three charts failed to meet the luminance uniformity standard (Lmin/Lmax ≥ 80%). Two charts were operating beyond manufacturer's recommended lamp replacement schedule. With room lights on, chart mean luminance and Weber contrast increased, but two charts still had inadequate luminance uniformity. Tablet computers showed less inter-device variability, higher contrast, and better luminance uniformity than charts in both lights-on and lights-off environments, providing brightness setting was >50%. Overall, iPad tablets matched or marginally out-performed ETDRS charts in terms of photometric compliance with high contrast acuity standards.


Assuntos
Telecomunicações/instrumentação , Acuidade Visual/fisiologia , Computadores de Mão , Humanos , Luz , Iluminação/instrumentação , Iluminação/métodos , Fotometria/instrumentação , Fotometria/métodos , Testes Visuais/métodos
2.
Phys Rev Lett ; 112(24): 242502, 2014 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-24996085

RESUMO

Information on the size and shape of the neutron skin on (208)Pb is extracted from coherent pion photoproduction cross sections measured using the Crystal Ball detector together with the Glasgow tagger at the MAMI electron beam facility. On exploitation of an interpolated fit of a theoretical model to the measured cross sections, the half-height radius and diffuseness of the neutron distribution are found to be c(n)=6.70±0.03(stat.) fm and a(n)=0.55±0.01(stat.)(-0.03)(+0.02)(sys.) fm, respectively, corresponding to a neutron skin thickness Δr(np)=0.15±0.03(stat.)(-0.03)(+0.01)(sys.) fm. The results give the first successful extraction of a neutron skin thickness with an electromagnetic probe and indicate that the skin of (208)Pb has a halo character. The measurement provides valuable new constraints on both the structure of nuclei and the equation of state for neutron-rich matter.

3.
Artigo em Inglês | MEDLINE | ID: mdl-25570419

RESUMO

A novel, tablet-based application (app) has been developed to act as a screening tool for visual impairment in stroke survivors; The Stroke Vision app. The app includes assessments for visual acuity, visual fields and visuospatial neglect, as well as novel tools for the education of patients, carers and staff. The app has been devised by experts in the field to address two important deficiencies; firstly a set of visual assessment tools to support and improve evaluation and rehabilitation of visual impairments in stroke survivors, and secondly to provide education for staff and information to carers about their relatives visual disabilities.


Assuntos
Reabilitação do Acidente Vascular Cerebral , Transtornos da Visão/diagnóstico , Cuidadores , Computadores , Humanos , Destreza Motora , Reabilitação , Acidente Vascular Cerebral/fisiopatologia , Sobreviventes , Testes Visuais , Visão Ocular , Acuidade Visual , Campos Visuais
4.
Phys Rev Lett ; 100(13): 132301, 2008 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-18517938

RESUMO

We present the first detailed measurement of incoherent photoproduction of neutral pions to a discrete state of a residual nucleus. The 12C(gamma,pi(0))(12)C*(4.4 MeV) reaction has been studied with the Glasgow photon tagger at MAMI employing a new technique which uses the large solid angle Crystal Ball detector both as a pi(0) spectrometer and to detect decay photons from the excited residual nucleus. The technique has potential applications to a broad range of future nuclear measurements with the Crystal Ball and similar detector systems elsewhere. Such data are sensitive to the propagation of the Delta in the nuclear medium and will give the first information on matter transition form factors from measurements with an electromagnetic probe. The incoherent cross sections are compared to two theoretical predictions including a Delta-hole model.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA