Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
1.
JTCVS Open ; 16: 450-459, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204642

RESUMO

Objective: To determine the characteristics and outcomes of patients requiring prolonged (>90 days) venovenous extracorporeal membrane oxygenation (VV ECMO) support for refractory Coronavirus disease 2019 (COVID-19)-associated respiratory failure. Methods: A retrospective, observational analysis of consecutive patients requiring VV ECMO for COVID-19-associated respiratory failure was performed at a single institution between March 2020 and January 2022. Data were collected from the medical records. Patients were predominantly cannulated and supported long-term with a single, dual-lumen cannula in the internal jugular vein with the tip positioned in the pulmonary artery. All patients were managed with an awake VV ECMO approach, emphasizing avoidance of sedatives, extubation, ambulation, physical therapy, and nutrition. Patients requiring >90 days of ECMO were identified, analyzed, and compared to those needing a shorter duration of support. Results: A total of 44 patients were supported on VV ECMO during the study period, of whom 36 (82%) survived to discharge. Thirty-one patients were supported for <90 days, of whom 28 (90%) were discharged alive. Thirteen patients required >90 days of ECMO. All patients were extubated. Eight patients (62%) survived to discharge, with 1 patient requiring lung transplantation prior to decannulation. All survivors were free from mechanical ventilation and alive at a 6-month follow-up. Of the 4 patients who died on prolonged ECMO, 2 developed hemothorax necessitating surgery and 2 succumbed to fatal intracranial hemorrhage. Conclusions: Patients treated with VV ECMO for COVID-19-associated respiratory failure may require prolonged support to recover. Extubation, ambulation, aggressive rehabilitation, and nutritional support while on ECMO can yield favorable outcomes.

2.
ASAIO J ; 68(4): 478-485, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-35349522

RESUMO

Cessation of continuous analgesia and sedation in patients with acute respiratory distress syndrome (ARDS) receiving venovenous (VV) extracorporeal membrane oxygenation (ECMO) facilitates early extubation, family, patient and provider engagement, and mobility. Outcomes associated with an awake ECMO strategy have not been well described in the literature. The purpose of this study was to evaluate outcomes in patients receiving this strategy. This was a retrospective review of ARDS patients receiving awake VV ECMO. The primary outcome was survival to hospital discharge. Secondary outcomes included days requiring ECMO, time from cannulation to extubation, complications, patients requiring tracheostomy, hospital and intensive care unit (ICU) length of stay (LOS), and discharge disposition. In a subgroup analysis, outcomes were compared between non-COVID and COVID ECMO patients. Sixty-two patients were included with a survival to hospital discharge of 85.5%. Days requiring ECMO was 33.0 (0.0-75.0) and cannulation to extubation was 6.0 (4.0-11.0). Three patients received a tracheostomy (4.8%). Bleeding and infection were reported in 80.6% and 82.3% of patients, respectively. Intensive care unit length of stay was 46.0 days (29.0-90.0) and hospital LOS was 51.0 days (32.0-91.0). Over half of the patients (51.6%) were discharged to an acute rehabilitation facility and 27.4% were discharged home. There was similar survival to hospital discharge between the COVID and non-COVID awake ECMO patients (85% in both groups, p = 1.000). This study highlights the impact of an awake ECMO approach on survival to hospital discharge. Future studies are needed to evaluate this approach as compared to current practice to determine if this should become the standard.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Extubação/efeitos adversos , COVID-19/terapia , Oxigenação por Membrana Extracorpórea/efeitos adversos , Humanos , Estudos Retrospectivos , Vigília
3.
Artif Organs ; 46(8): 1659-1668, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35191553

RESUMO

In a multicenter, retrospective analysis of 435 patients with refractory COVID-19 placed on V-V ECMO, cannulation by a single, dual-lumen catheter with directed outflow to the pulmonary artery was associated with lower inpatient mortality.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , COVID-19/terapia , Cateterismo/métodos , Catéteres , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/métodos , Humanos , Estudos Retrospectivos
4.
ASAIO J ; 68(1): 14-20, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34524147

RESUMO

The study aim was to examine the impact time in therapeutic range (TTR, International Normalized Ratio [INR] 2.0-3.0) has on survival and adverse events in patients receiving the HeartWare HVAD System in the ENDURANCE and ENDURANCE Supplemental Trials. Evaluable subjects (n = 495) had >1 INR value recorded 1-24 months postimplant and were categorized as: low TTR (10-39%), moderate TTR (40-69%), and high TTR (≥70%). Baseline characteristics, adverse events, and survival were analyzed. Low TTR patients experienced higher rates of major bleeding (1.69 vs. 0.54 events per patient year [EPPY]; p < 0.001), GI bleeding (1.22 vs. 0.38 EPPY; p < 0.001), stroke (0.47 vs. 0.17 EPPY; p < 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.02), infection (1.44 vs. 0.69 EPPY; p < 0.001), and renal dysfunction (0.23 vs. 0.05 EPPY; p < 0.001) compared with high TTR. Moderate TTR had higher rates of major bleeding (0.75 vs. 0.54 EPPY; p < 0.001), thrombus requiring exchange (0.05 vs. 0.01 EPPY; p = 0.007), cardiac arrhythmia (0.32 vs. 0.24 EPPY; p = 0.04), and infection (0.90 vs. 0.69 EPPY; p = 0.001) compared with high TTR. Two year survival was greater among moderate and high versus low cohorts (Log-rank p = 0.001). The significant reduction in morbidity and mortality in destination therapy (DT) HVAD patients with well-controlled TTR (≥70%) emphasizes the importance of vigilant anticoagulation management.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Anticoagulantes , Hemorragia/etiologia , Humanos , Coeficiente Internacional Normatizado , Resultado do Tratamento
5.
J Thorac Cardiovasc Surg ; 163(6): 2107-2116.e6, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34112505

RESUMO

OBJECTIVE: To determine characteristics, outcomes, and clinical factors associated with death in patients with COVID-19 requiring extracorporeal membrane oxygenation (ECMO) support. METHODS: A multicenter, retrospective cohort study was conducted. The cohort consisted of adult patients (18 years of age and older) requiring ECMO in the period from March 1, 2020, to September 30, 2020. The primary outcome was in-hospital mortality after ECMO initiation assessed with a time to event analysis at 90 days. Multivariable Cox proportional regression was used to determine factors associated with in-hospital mortality. RESULTS: Overall, 292 patients from 17 centers comprised the study cohort. Patients were 49 (interquartile range, 39-57) years old and 81 (28%) were female. At the end of the follow-up period, 19 (6%) patients were still receiving ECMO, 25 (9%) were discontinued from ECMO but remained hospitalized, 135 (46%) were discharged or transferred alive, and 113 (39%) died during the hospitalization. The cumulative in-hospital mortality at 90 days was 42% (95% confidence interval [CI], 36%-47%). Factors associated with in-hospital mortality were age (adjusted hazard ratio [aHR], 1.31; 95% CI, 1.06-1.61 per 10 years), renal dysfunction measured according to serum creatinine level (aHR, 1.21; 95% CI, 1.01-1.45), and cardiopulmonary resuscitation before ECMO placement (aHR, 1.87; 95% CI, 1.01-3.46). CONCLUSIONS: In patients with severe COVID-19 necessitating ECMO support, in-hospital mortality occurred in fewer than half of the cases. ECMO might serve as a viable modality for terminally ill patients with refractory COVID-19.


Assuntos
COVID-19 , Oxigenação por Membrana Extracorpórea , Síndrome do Desconforto Respiratório , Adolescente , Adulto , COVID-19/terapia , Criança , Oxigenação por Membrana Extracorpórea/efeitos adversos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
6.
Transplant Proc ; 53(10): 3051-3055, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34772489

RESUMO

Invasive pulmonary mucormycosis is a potentially fatal infection that can occur in immunosuppressed patients such as those who have undergone orthotopic heart transplant (OHT). High-dose intravenous antifungal agents, including amphotericin B, are generally accepted as the first-line medical treatment, with prompt surgical resection of lesions if feasible. The body of evidence guiding treatment decisions, however, is sparse, particularly regarding adjustment of immunosuppression during acute infection and long-term recovery. We present 2 cases of patients with pulmonary mucormycosis occurring within the first 6 months after OHT, both of whom successfully recovered after appropriate medical and surgical treatment, and we highlight differences in immunosuppression management strategies for this life-threatening condition.


Assuntos
Transplante de Coração , Mucormicose , Anfotericina B , Antifúngicos/uso terapêutico , Transplante de Coração/efeitos adversos , Humanos , Hospedeiro Imunocomprometido , Mucormicose/diagnóstico , Mucormicose/tratamento farmacológico , Mucormicose/etiologia
8.
Ann Surg ; 274(5): e388-e394, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-34617934

RESUMO

OBJECTIVE: Does extracorporeal membrane oxygenation (ECMO) improve outcomes in ECMO-eligible patients with COVID-19 respiratory failure compared to maximum ventilation alone (MVA)? SUMMARY BACKGROUND DATA: ECMO is beneficial in severe cases of respiratory failure when mechanical ventilation is inadequate. Outcomes for ECMO-eligible COVID-19 patients on MVA have not been reported. Consequently, a direct comparison between COVID-19 patients on ECMO and those on MVA has not been established. METHODS: A total of 3406 COVID-19 patients treated at two major medical centers in Chicago were studied. One hundred ninety-five required maximum ventilatory support, and met ECMO eligibility criteria. Eighty ECMO patients were propensity matched to an equal number of MVA patients using detailed demographic, physiological, and comorbidity data. Primary outcome was survival and disposition at discharge. RESULTS: Seventy-one percent of patients were decannulated from ECMO. Mechanical ventilation was discontinued in 75% ECMO and 16% MVA patients. Twenty-five percent of patients in the ECMO arm expired, 21% while on ECMO, compared with 74% in the MVA cohort. Mortality was significantly lower across all age and BMI groups in the ECMO arm. Sixty-eight percent ECMO and 26% MVA patients were discharged from the hospital. Fewer ECMO patients required long-term rehabilitation. Major complications such as septic shock, ventilator associated pneumonia, inotropic requirements, acute liver and kidney injuries are less frequent among ECMO patients. CONCLUSIONS: ECMO-eligible patients with severe COVID-19 respiratory failure demonstrate a 3-fold improvement in survival with ECMO. They are also in a better physical state at discharge and have lower overall complication rates. As such, strong consideration should be given for ECMO when mechanical ventilatory support alone becomes insufficient in treating COVID-19 respiratory failure.


Assuntos
COVID-19/terapia , Oxigenação por Membrana Extracorpórea/métodos , Pontuação de Propensão , Respiração Artificial/métodos , Insuficiência Respiratória/terapia , Adulto , Idoso , COVID-19/complicações , COVID-19/epidemiologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Alta do Paciente/tendências , Insuficiência Respiratória/epidemiologia , Insuficiência Respiratória/etiologia , Estudos Retrospectivos , SARS-CoV-2 , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia , Adulto Jovem
11.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-30883052

RESUMO

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia
12.
JACC Heart Fail ; 6(9): 792-802, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30007559

RESUMO

OBJECTIVES: The aim of this study was to prospectively evaluate the impact of blood pressure management on stroke rates in patients receiving the HeartWare HVAD System. BACKGROUND: The ENDURANCE trial demonstrated noninferiority of the HeartWare HVAD System versus control (HeartMate II) in patients with advanced heart failure ineligible for heart transplantation. However, stroke was more common in HVAD subjects. Post hoc analyses demonstrated increased mean arterial blood pressure as a significant independent risk factor for stroke. METHODS: The ENDURANCE Supplemental Trial was a prospective, multicenter evaluation of 465 patients with advanced heart failure ineligible for transplantation, randomized 2:1 to HVAD (n = 308) or control (n = 157). The primary endpoint was the 12-month incidence of transient ischemic attack or stroke with residual deficit 24 weeks post-event. Secondary endpoints included the composite of freedom from death, disabling stroke, and need for device replacement or urgent transplantation, as well as comparisons of stroke or transient ischemic attack rates in HVAD cohorts in ENDURANCE Supplemental and ENDURANCE. RESULTS: The enhanced blood pressure protocol significantly reduced mean arterial blood pressure. The primary endpoint was not achieved (14.7% with HVAD vs. 12.1% with control, noninferiority [margin 6%] p = 0.14). However, the secondary composite endpoint demonstrated superiority of HVAD (76.1%) versus control (66.9%) (p = 0.04). The incidence of stroke in HVAD subjects was reduced 24.2% in ENDURANCE Supplemental compared with ENDURANCE (p = 0.10), and hemorrhagic cerebrovascular accident was reduced by 50.5% (p = 0.02). CONCLUSIONS: The ENDURANCE Supplemental Trial failed to demonstrate noninferiority of HVAD versus control regarding the pre-specified primary endpoint. However, the trial confirmed that BP management is associated with reduced stroke rates in HVAD subjects. HVAD subjects, relative to control subjects, more commonly achieved the composite endpoint (freedom from death, disabling stroke, and device replacement or urgent transplantation). (A Clinical Trial to Evaluate the HeartWare™ Ventricular Assist System [ENDURANCE SUPPLEMENTAL TRIAL] [DT2]; NCT01966458).


Assuntos
Anti-Hipertensivos/uso terapêutico , Insuficiência Cardíaca/terapia , Coração Auxiliar , Hipertensão/tratamento farmacológico , Ataque Isquêmico Transitório/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Idoso , Anticoagulantes/uso terapêutico , Pressão Arterial , Monitorização Ambulatorial da Pressão Arterial , Estudos de Equivalência como Asunto , Feminino , Insuficiência Cardíaca/epidemiologia , Humanos , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos
13.
N Engl J Med ; 378(15): 1386-1395, 2018 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-29526139

RESUMO

BACKGROUND: In an early analysis of this trial, use of a magnetically levitated centrifugal continuous-flow circulatory pump was found to improve clinical outcomes, as compared with a mechanical-bearing axial continuous-flow pump, at 6 months in patients with advanced heart failure. METHODS: In a randomized noninferiority and superiority trial, we compared the centrifugal-flow pump with the axial-flow pump in patients with advanced heart failure, irrespective of the intended goal of support (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke (with disabling stroke indicated by a modified Rankin score of >3; scores range from 0 to 6, with higher scores indicating more severe disability) or survival free of reoperation to replace or remove a malfunctioning device. The noninferiority margin for the risk difference (centrifugal-flow pump group minus axial-flow pump group) was -10 percentage points. RESULTS: Of 366 patients, 190 were assigned to the centrifugal-flow pump group and 176 to the axial-flow pump group. In the intention-to-treat population, the primary end point occurred in 151 patients (79.5%) in the centrifugal-flow pump group, as compared with 106 (60.2%) in the axial-flow pump group (absolute difference, 19.2 percentage points; 95% lower confidence boundary, 9.8 percentage points [P<0.001 for noninferiority]; hazard ratio, 0.46; 95% confidence interval [CI], 0.31 to 0.69 [P<0.001 for superiority]). Reoperation for pump malfunction was less frequent in the centrifugal-flow pump group than in the axial-flow pump group (3 patients [1.6%] vs. 30 patients [17.0%]; hazard ratio, 0.08; 95% CI, 0.03 to 0.27; P<0.001). The rates of death and disabling stroke were similar in the two groups, but the overall rate of stroke was lower in the centrifugal-flow pump group than in the axial-flow pump group (10.1% vs. 19.2%; hazard ratio, 0.47; 95% CI, 0.27 to 0.84, P=0.02). CONCLUSIONS: In patients with advanced heart failure, a fully magnetically levitated centrifugal-flow pump was superior to a mechanical-bearing axial-flow pump with regard to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755 .).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adulto , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Qualidade de Vida , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Trombose/etiologia , Resultado do Tratamento , Teste de Caminhada
14.
Circulation ; 135(21): 2003-2012, 2017 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-28385948

RESUMO

BACKGROUND: The HeartMate 3 (HM3) Left Ventricular Assist System (LVAS) (Abbott) is a centrifugal, fully magnetically levitated, continuous-flow blood pump engineered to enhance hemocompatibility and reduce shear stress on blood components. The MOMENTUM 3 trial (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3) compares the HM3 LVAS with the HeartMate II (HMII) LVAS (Abbott) in advanced heart failure refractory to medical management, irrespective of therapeutic intention (bridge to transplant versus destination therapy). This investigation reported its primary outcome in the short-term cohort (n=294; 6-month follow-up), demonstrating superiority of the HM3 for the trial primary end point (survival free of a disabling stroke or reoperation to replace the pump for malfunction), driven by a reduced need for reoperations. The aim of this analysis was to evaluate the aggregate of hemocompatibility-related clinical adverse events (HRAEs) between the 2 LVAS. METHODS: We conducted a secondary end point evaluation of HRAE (survival free of any nonsurgical bleeding, thromboembolic event, pump thrombosis, or neurological event) in the short-term cohort (as-treated cohort n=289) at 6 months. The net burden of HRAE was also assessed by using a previously described hemocompatibility score, which uses 4 escalating tiers of hierarchal severity to derive a total score for events encountered during the entire follow-up experience for each patient. RESULTS: In 289 patients in the as-treated group (151 the HM3 and 138 the HMII), survival free of any HRAE was achieved in 69% of the HM3 group and in 55% of the HMII group (hazard ratio, 0.62; confidence interval, 0.42-0.91; P=0.012). Using the hemocompatibility score, the HM3 group demonstrated less pump thrombosis requiring reoperation (0 versus 36 points, P<0.001) or medically managed pump thrombosis (0 versus 5 points, P=0.02), and fewer nondisabling strokes (6 versus 24 points, P=0.026) than the control HMII LVAS. The net hemocompatibility score in the HM3 in comparison with the HMII patients was 101 (0.67±1.50 points/patient) versus 137 (0.99±1.79 points/patient) (odds ratio, 0.64; confidence interval, 0.39-1.03; P=0.065). CONCLUSIONS: In this secondary analysis of the MOMENTUM 3 trial, the HM3 LVAS demonstrated greater freedom from HRAEs in comparison with the HMII LVAS at 6 months. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique identifier: NCT02224755.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Imãs , Função Ventricular Esquerda , Idoso , Remoção de Dispositivo , Intervalo Livre de Doença , Desenho de Equipamento , Falha de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Coração Auxiliar/efeitos adversos , Hemólise , Humanos , Estimativa de Kaplan-Meier , Masculino , Teste de Materiais , Pessoa de Meia-Idade , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Prospectivos , Fatores de Risco , Estresse Mecânico , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
15.
N Engl J Med ; 376(5): 451-460, 2017 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-28146651

RESUMO

BACKGROUND: Mechanical circulatory support with a left ventricular assist device (LVAD) is an established treatment for patients with advanced heart failure. We compared a newer LVAD design (a small intrapericardial centrifugal-flow device) against existing technology (a commercially available axial-flow device) in patients with advanced heart failure who were ineligible for heart transplantation. METHODS: We conducted a multicenter randomized trial involving 446 patients who were assigned, in a 2:1 ratio, to the study (centrifugal-flow) device or the control (axial-flow) device. Adults who met contemporary criteria for LVAD implantation for permanent use were eligible to participate in the trial. The primary end point was survival at 2 years free from disabling stroke or device removal for malfunction or failure. The trial was powered to show noninferiority with a margin of 15 percentage points. RESULTS: The intention-to treat-population included 297 participants assigned to the study device and 148 participants assigned to the control device. The primary end point was achieved in 164 patients in the study group and 85 patients in the control group. The analysis of the primary end point showed noninferiority of the study device relative to the control device (estimated success rates, 55.4% and 59.1%, respectively, calculated by the Weibull model; absolute difference, 3.7 percentage points; 95% upper confidence limit, 12.56 percentage points; P=0.01 for noninferiority). More patients in the control group than in the study group had device malfunction or device failure requiring replacement (16.2% vs. 8.8%), and more patients in the study group had strokes (29.7% vs. 12.1%). Quality of life and functional capacity improved to a similar degree in the two groups. CONCLUSIONS: In this trial involving patients with advanced heart failure who were ineligible for heart transplantation, a small, intrapericardial, centrifugal-flow LVAD was found to be noninferior to an axial-flow LVAD with respect to survival free from disabling stroke or device removal for malfunction or failure. (Funded by HeartWare; ENDURANCE ClinicalTrials.gov number, NCT01166347 .).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Idoso , Intervalo Livre de Doença , Insuficiência Cardíaca/mortalidade , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Qualidade de Vida , Acidente Vascular Cerebral/etiologia
16.
J Artif Organs ; 19(1): 21-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26187243

RESUMO

High rates of right ventricular failure continue to affect postoperative outcomes in patients implanted with left ventricular assist devices (LVADs). Development of right ventricular failure and implantation with right ventricular assist devices is known to be associated with significantly increased mortality. The model for end-stage liver disease (MELD) score is an effective means of evaluating liver dysfunction. We investigated the prognostic utility of postoperative MELD on post-LVAD implantation outcomes. MELD scores, demographic data, and outcomes including length of stay, survival, and postoperative right ventricular failure were collected for 256 patients implanted with continuous flow LVADs. Regression and Kaplan-Meier analyses were used to investigate the relationship between MELD and all outcomes. Increased MELD score was found to be an independent predictor of both right heart failure and necessity for RVAD implantation (OR 1.097, CI 1.040-1.158, p = 0.001; OR 1.121, CI 1.015, p = 0.024, respectively). Patients with RV failure and who underwent RVAD implantation had reduced postoperative survival compared to patients with RV dysfunction (no RV failure = 651.4 ± 609.8 days, RV failure = 392.6 ± 444.8 days, RVAD = 89.3 ± 72.8 days; p < 0.001). In conclusion, MELD can be used to reliably predict postoperative right heart failure and the necessity for RVAD implantation. Those patients with RV failure and RVADs experience significantly increased postoperative mortality compared to those without RV dysfunction.


Assuntos
Doença Hepática Terminal/diagnóstico , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Disfunção Ventricular Direita/etiologia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Disfunção Ventricular Direita/cirurgia
17.
ASAIO J ; 62(1): 46-55, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26536535

RESUMO

The use of left ventricular assist devices (LVADs), implantable pumps used to supplement cardiac output, has become an increasingly common and effective treatment for advanced heart failure. Although modern continuous-flow LVADs improve quality of life and survival more than medical management of heart failure, device malfunction remains a common concern. Improved noninvasive methods for assessment of LVAD function are needed to detect device complications. An electronic stethoscope was used to record sounds from the HeartMate II axial flow pump in vitro and in vivo. The data were then uploaded to a computer and analyzed using two types of acoustic analysis software. Left ventricular assist device acoustics were quantified and were related to pump speed, acoustic environment, and inflow and outflow graft patency. Peak frequency values measured in vivo were found to correlate strongly with both predicted values and in vitro measurements (r > 0.999). Plots of the area under the acoustic spectrum curve, obtained by integrating over 50 Hz increments, showed strong correlations between in vivo and in vitro measurements (r > 0.966). Device thrombosis was found to be associated with reduced LVAD acoustic amplitude in two patients who underwent surgical device exchange.


Assuntos
Acústica/instrumentação , Auscultação Cardíaca/instrumentação , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Som , Débito Cardíaco , Eletrônica , Insuficiência Cardíaca/fisiopatologia , Humanos , Modelos Cardiovasculares , Software , Estetoscópios
18.
ASAIO J ; 61(6): 664-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26181711

RESUMO

The neutrophil-to-lymphocyte ratio (NLR) has been used to predict mortality in a wide range of cardiovascular diseases including acute decompensated heart failure and non-ST-elevation myocardial infarction. We investigated the prognostic utility of the NLR in patients with advanced heart failure who received left ventricular assist devices (LVADs). Two hundred seventy-three patients implanted with LVADs at our institution were divided into tertiles based on their NLR and were retrospectively analyzed. Outcomes, including survival and right ventricular (RV) failure, were compared between tertiles. The NLR was found to be an independent predictor of postoperative mortality (odds ratio [OR] = 1.159, confidence interval [CI] = 1.022-1.314, p = 0.021) and of postoperative RV failure (OR = 1.117, CI = 1.039-1.201, p = 0.003). In addition, patients in the highest NLR tertile were found to have significantly increased postoperative length of stay (tertile 1 = 20.6 ± 10.7 days, tertile 2 = 24.2 ± 20.7 days, and tertile 3 = 28.8 ± 18.6 days, p = 0.001). In conclusion, the NLR is a simple and practical method for predicting adverse outcomes including all-cause mortality and RV failure after LVAD implantation.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Contagem de Leucócitos , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Linfócitos , Masculino , Pessoa de Meia-Idade , Neutrófilos , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia
19.
JACC Heart Fail ; 3(4): 303-13, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25770405

RESUMO

OBJECTIVES: This study evaluated gastrointestinal bleeding (GIB) in patients receiving the HeartWare HVAD System (HeartWare Inc., Framingham, Massachusetts) in the pivotal BTT (Bridge to Transplant) trial and under the continued access protocol (CAP). BACKGROUND: GIB has become a significant problem for recipients of continuous flow device left ventricular assist devices (CF-LVAD). The need for anticoagulation and antiplatelet therapies complicates the management of GIB. METHODS: Bleeding events from 382 patients with advanced heart failure (140 patients enrolled in the BTT trial, and an additional 242 CAP patients) were analyzed. Post-implant anticoagulation consisted of heparin followed by warfarin at a target international normalized ratio of 2 to 3. Acetylsalicylic acid was recommended at 81 to 325 mg. RESULTS: Overall, 59 of 382 (15.4%) patients experienced 108 GIB events (0.27 events per patient year). Mean time to first bleed was 273.1 days and 86.1% of events occurred beyond 30 days. Freedom from GIB was 84.1% at 1 year. Median international normalized ratio at the time of first bleed was 2.4 ± 1.4. The most common etiology of bleeding identified was arteriovenous malformation and the most common site was the small intestine. Repeat bleeding was infrequent, though GIB patients required more readmissions and developed nondevice infections more frequently. No patients required surgical intervention and no deaths directly related to GIB occurred. CONCLUSIONS: Recipients of the HeartWare Ventricular Assist Device System had an incidence of 0.27 GIB/patient year with a freedom from GIB of 84.1% at 1 year. All patients with GIB events were managed with medical and endoscopic therapies, although 31% of patients experienced a recurrence of GIB. No surgical intervention was required. GIB did not impact survival. (Evaluation of the HeartWare Left Ventricular Assist Device for the Treatment of Advanced Heart Failure [ADVANCE]; NCT00751972).


Assuntos
Hemorragia Gastrointestinal/etiologia , Insuficiência Cardíaca/terapia , Coração Auxiliar/efeitos adversos , Anticoagulantes/efeitos adversos , Feminino , Hemorragia Gastrointestinal/mortalidade , Insuficiência Cardíaca/mortalidade , Transplante de Coração/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/efeitos adversos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...