Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Port Pneumol (2006) ; 21(4): 185-91, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25926254

RESUMO

INTRODUCTION: Pulmonary tuberculosis (TB) requires an early diagnosis for prompt introduction of treatment and prevention of transmission. Definitive diagnosis is obtained by microbiological culture and identification of Mycobacterium tuberculosis in respiratory specimens, mostly sputum samples. MATERIALS AND METHODS: Retrospective data analysis of all patients suspected of pulmonary TB that submitted three consecutive sputum samples to the Pulmonology Diagnostic Center (PDC) Laboratory between 2004 and 2013. Extrapulmonary TB cases were excluded. Four microbiological analyses were executed on each specimen: two smears with Ziehl-Neelsen staining, direct and concentrate; and two culture examinations, one in liquid and one in solid medium. Statistical analysis was performed by SPSS. RESULTS: A total of 694 patients were enrolled in this study (65% men, mean age 48.5±18.6 years, 97% Portuguese), most of them exhibiting TB-related complaints. Pulmonary TB was diagnosed in 41% of the patients; 54% had non-specific radiological changes and 34% had pulmonary cavitation. The cumulative sensitivity rates of each of the three smears were 24.6%, 27.7% and 28.8% for concentrated samples and 19.3%, 20.4% and 22.5% for direct samples. The cumulative sensitivities of sputum culture were 33.3%, 37.9% and 41.8% for solid medium, and 43.9%, 51.6% and 55.4% for liquid medium. Pondering all forms of microbiological analysis, the cumulative sensitivities of each sample were 51.2%, 59.6% and 63.2%. There was an incremental yield of 8.4% for the second specimen and 3.5% for the third specimen. All sensitivity rates were higher among patients with pulmonary cavitation. CONCLUSIONS: This study showed an incremental yield with more than one sputum sample. However, overall sensitivity remained low, suggesting a need for new diagnostic strategies and novel and better diagnostic tools.


Assuntos
Escarro/microbiologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
2.
Rev Port Pneumol (2006) ; 21(2): 69-75, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25926369

RESUMO

INTRODUCTION: International guidelines define significant bronchodilator response as absolute and percentage change from baseline in forced expiratory volume (FEV1) in the first second and/or forced vital capacity (FVC) ≥12% and 200 mL. However, bronchodilator effects on other lung function parameters have also been correlated to some degree of reversible airflow limitation. OBJECTIVES: To determine whether changes in other lung function parameters apart from FEV1 and FVC detect functional responses to bronchodilator in asthmatic patients. MATERIALS AND METHODS: Spirometry and body plethysmography were performed at baseline conditions and after administration of 400 µg of salbutamol by metered-dose inhaler through a space chamber device in asthmatic patients. Paired t-tests were used to compare lung function parameters between those with and without criteria for reversibility of airway obstruction according to ATS/ERS criteria. Cut-off values were obtained from the corresponding ROC curves. Measurements evaluated were FEV1, FVC, maximum mid-forced expiratory flow (FEF25-75%), residual volume (RV), inspiratory capacity (IC), airway resistance (Raw) and specific airway conductance (sGaw). RESULTS: From a total of 100 consecutive asthmatics patients (46% of them men; average age 58.7±14.1 years; 76% with mild to moderate obstruction), 50 patients had a significant bronchodilator response. All of these had noteworthy variations (p<0.004) in PEF, FEF25-75%, RV, Raw and sGaw. The most accurate in predicting a significant bronchodilator response were the absolute and percentage improvements in PEF (≥0.4 L/s and 8%), FEF25-75% (≥0.087 L/s and 27%) and the percentage of sGaw compared with that at baseline (≥25%). Based on these cut-off values, a sizeable number of the patients defined as non-responders had important changes in airway caliber. 17 patients had significant increments in the percentage of PEF and 10 had changes in absolute volume; 6 patients had increments in percentage and 16 in absolute change of FEF25-75%; 22 patients had increments in the percentage change of sGaw. CONCLUSIONS: Changes of FEV1 and/or FVC may underestimate significant functional response to bronchodilators in asthmatic patients with airway obstruction when considering the change in other lung function parameters.


Assuntos
Asma/tratamento farmacológico , Asma/fisiopatologia , Broncodilatadores/uso terapêutico , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória
3.
Rev Port Pneumol ; 2014 Oct 29.
Artigo em Inglês, Português | MEDLINE | ID: mdl-25445252

RESUMO

This article has been withdrawn for editorial reasons because the journal will be published only in English. In order to avoid duplicated records, this article can be found at http://dx.doi.org/10.1016/j.rppnen.2014.08.002. The Publisher apologizes for any inconvenience this may cause. The full Elsevier Policy on Article Withdrawal can be found at http://www.elsevier.com/locate/withdrawalpolicy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...