Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
Prev Med Rep ; 33: 102217, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37223561

RESUMO

Background: Binge drinking and binge eating are prevalent, frequently co-occurring, high-risk behaviors among emerging adult women, each with physical and psychological consequences. The mechanisms driving their co-occurrence are not well understood, though a history of adverse childhood experiences (ACEs) may increase the risk for both binge behaviors. Objective: To assess the association between ACE subtypes and individual and co-occurring binge drinking and eating in emerging adult women. Participants and Setting: A diverse sample of women participating in the population-based study EAT 2018: Eating and Activity over Time (N = 788; aged 18-30; 19% Asian, 22% Black, 19% Latino, and 36% White). Methods: Multinomial logistic regression estimated associations among ACE subtypes (i.e., sexual abuse, physical abuse, emotional abuse, household dysfunction), and binge drinking, binge eating, and their co-occurrence. Results are reported as predicted probabilities (PP) of each outcome. Results: Over half of the sample (62%) reported at least one ACE. In models mutually adjusted for other ACEs, physical and emotional abuse showed the strongest associations with binge behaviors. Experiences of physical abuse had the strongest association with a ten-percentage point higher predicted probability of binge drinking (PP = 37%, 95% [CI 27-47%]) and seven-percentage point higher PP of co-occurring binge eating and drinking (PP = 12%, 95% CI [5-19%]). Emotional abuse had the strongest association with an 11-percentage point higher PP binge eating only (PP = 20%, 95% CI [11-29%]). Conclusions: This study found childhood physical and emotional abuse to be particularly relevant risk factors for binge drinking, binge eating, and their co-occurrence among emerging adult women.

2.
Europace ; 22(8): 1189-1196, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32601674

RESUMO

AIMS: The relation between atrial tachyarrhythmia (ATA) burden in paroxysmal atrial fibrillation (AF), atrial remodelling, and efficacy of catheter ablation (CA) is unknown. We investigated whether high vs. low-burden paroxysmal AF patients have distinct clinical characteristics or electro-mechanical properties of the left atrium (LA) and whether burden impacts outcome of CA. METHODS AND RESULTS: Atrial tachyarrhythmia burden, defined as the percentage of time spent in ATA, was assessed by insertable cardiac monitors in 105 patients before and after CA. Clinical characteristics and electro-mechanical properties of LA were compared between patients with high vs. low ATA burden. Catheter ablation efficacy was assessed by reduction in ATA burden and 1-year freedom from any ATA. Median ATA burden was 2.7% (highest tertile 9.3%). Clinical characteristics and electrical properties of LA (refractoriness, conduction velocity, low voltage) did not differ between high (≥9.3%) vs. low ATA burden (<9.3%) patients. High ATA burden patients had larger LA diameter (46.5 ± 6 vs. 42.5 ± 6mm, P < 0.01), volume (93.8 ± 22 vs. 80.4 ± 21mL, P = 0.01), and lower LA reservoir and contractile strain (19.7 ± 6 vs. 24.7 ± 6%, P < 0.01; 10.3 ± 3 vs. 12.8 ± 4%, P = 0.01). Catheter ablation reduced ATA burden by 100% (100-100) in both groups (P = 1.0). Freedom from ATA after CA was equally high (83% vs. 89%, P = 0.38). CONCLUSION: Paroxysmal AF patients with high ATA burden have altered LA mechanical properties, reflected by larger size and impaired function. Despite mechanical remodelling of the atria, they are excellent responders to CA. Most likely the lack of fibrosis and/or advanced electrical remodelling explain why pulmonary veins remain the dominant trigger for AF in this patient cohort.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento
3.
J Interv Card Electrophysiol ; 51(3): 271-277, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29478174

RESUMO

PURPOSE: Catheter ablation is an effective treatment for premature ventricular complexes (PVCs). Activation mapping is accurate but requires PVCs at the time of the ablation. Pace-mapping correlation (PMC) is a supplemental tool recently developed as an integrated module for an electro-anatomical mapping platform. Our study sought to investigate whether pace-mapping technology provides similar ablation results in patients with low versus high idiopathic PVC burden at the time of ablation and the relationship between sites with the highest PMC and the earliest local activation time (LAT). METHODS: A total of 59 consecutive patients undergoing catheter ablation for idiopathic PVCs were enrolled. Twelve out of 59 patients (20%) were classified in the low PVC burden group (defined as < 2 PVCs/min) and 47/59 (80%) in the high PVC burden group. RESULTS: The most common origin of PVCs was the right ventricular outflow tract (RVOT) followed by aortic cusps, coronary sinus, parahisian region, and aorto-mitral continuity. Procedural and 1-month success rate were 95 and 87% respectively. PVC burden at the time of ablation did not influence the success rate. The median distance between the earliest LAT points and the highest PMC points was 6.4 (4.9-10.6) mm. CONCLUSIONS: Pace-mapping correlation is useful and accurate in localizing the origin of idiopathic PVCs irrespective of the initial PVC burden. It provides optimal ablation results when combined with LAT. Success rate at mid-term follow-up is higher when the origin of PVCs is located in the RVOT as compared to other locations.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Complexos Ventriculares Prematuros/diagnóstico por imagem , Complexos Ventriculares Prematuros/cirurgia , Fatores Etários , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 27(1): 80-7, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26471955

RESUMO

AIM: To determine whether ventricular tachycardia (VT) recurrences in arrhythmogenic RV cardiomyopathy (ARVC) and nonischemic cardiomyopathy (NICM) are related to incomplete ablation or disease progression. METHODS: ARVC and NICM patients with two substrate maps of the same diseased ventricle with an interprocedural delay of ≥12 months were included. Disease progression was defined as ≥1 factor: scar area progression (PROG, +5%), ventricular remodeling (dilatation [+25 mL] or decreased ejection fraction [-5%EF]). Incomplete ablation was defined as index VT recurrence or ablation in previously unablated regions inside index scar without PROG. RESULTS: Twenty patients from nine centers were included (80% male 55 ± 16 years, 7 ARVC and 13 NICM, LVEF 43 ± 14%). Mean delay was 28 ± 18 months. Disease progression occurred in 75% with ventricular remodeling in 70%: ventricular dilation in 45% (ARVC [71%]; NICM [38%]), decreased EF in 60% [RVEF in ARVC (71%); LVEF in NICM (54%)], and scar progression in 50% (in ARVC [57%] and NICM [46%]). Index VT recurrence was observed in 40%. Redo ablation sites were located in previously unablated regions inside the index scar in 70% of patients. VT recurrence following the second procedure was seen in 25%. Fifteen percent died during a follow-up of 17 ± 17 months. CONCLUSION: Disease progression is the rule in ARVC and NICM while scar progression occurs in half. However, even if disease progression is frequently observed, incomplete index ablation is the most common finding, strongly suggesting the need for more extensive ablation.


Assuntos
Ablação por Cateter/efeitos adversos , Sistema de Condução Cardíaco/cirurgia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Displasia Arritmogênica Ventricular Direita/complicações , Cicatriz/etiologia , Cicatriz/fisiopatologia , Progressão da Doença , Técnicas Eletrofisiológicas Cardíacas , Europa (Continente) , Feminino , Sistema de Condução Cardíaco/patologia , Sistema de Condução Cardíaco/fisiopatologia , Ventrículos do Coração/patologia , Ventrículos do Coração/fisiopatologia , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Hipertrofia Ventricular Direita/etiologia , Hipertrofia Ventricular Direita/fisiopatologia , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Volume Sistólico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular
5.
Europace ; 16(6): 820-5, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24443035

RESUMO

AIMS: Pulmonary vein isolation (PVI) is an accepted treatment to relieve symptoms in patients with atrial fibrillation (AF). We studied 3 year outcome after PVI guided by duty-cycled multi-electrode radiofrequency (RF) ablation (pulmonary vein ablation catheter, PVAC) and provided comparative data to outcome after conventional PVI (CPVI) using mapping with irrigated, point-per-point RF ablation. METHODS AND RESULTS: One hundred and sixty-one consecutive patients with symptomatic paroxysmal or persistent AF and minimal heart disease underwent PVI (PVAC, n = 79 vs. CPVI, n = 82). Follow-up (with symptom-guided rhythm monitoring) was truncated at 3 years in all patients. Success was defined as freedom of documented arrhythmia after a single procedure and without antiarrhythmic drug treatment (ADT). Baseline characteristics did not differ between both groups. At 3 years follow-up, single-procedure success without ADT was comparable between PVAC and CPVI (65% vs. 55%, P = NS). The majority of recurrences occurred during the first year (PVAC 79% vs. CPVI 70%, P = NS). The annual rate of very late recurrence (i.e. beyond 1 year) was similar in both groups (10.5% vs. 15%, P = NS). CONCLUSION: At 3 years follow-up, outcome after PVAC-guided PVI is comparable to conventional isolation by irrigated point-by-point RF ablation. In both strategies, the majority of recurrences occurred in the first year of ablation.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Mapeamento Potencial de Superfície Corporal/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/métodos , Terapia Combinada/instrumentação , Terapia Combinada/métodos , Eletrodos , Feminino , Seguimentos , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Recidiva , Cirurgia Assistida por Computador/instrumentação , Irrigação Terapêutica/instrumentação , Irrigação Terapêutica/métodos , Resultado do Tratamento
6.
Indian Pacing Electrophysiol J ; 12(4): 171-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22912537

RESUMO

Although nowadays performed on a routine basis, catheter ablation of atrial fibrillation is associated with the potential for major complications. Improving the safety remains therefore an important challenge. This article summarizes the different types of complications associated with AF ablation grouping them into clinically overt major complications, subclinical injury and permanent injury. Furthermore, it describes the potential predictors for complications and highlights the dynamic interplay between efficacy and safety.

7.
J Atr Fibrillation ; 1(6): 161, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-28496618

RESUMO

Background: To identify and characterise pre-procedural and procedural parameters which predict maintenance of sinus rhythm after a first circumferential pulmonary vein isolation (CPVI) for recurrent atrial fibrillation (AF). Methods: 100 patients (54±10 yrs) undergoing CARTO-guided CPVI for symptomatic drug refractory, paroxysmal or shortstanding persistent AF were studied. The endpoint was complete electrical isolation within the encircled regions. 3D left atrial (LA) volume was measured by CARTO geometry. Follow-up examinations (symptoms, ECG, 24-hour ECG recording) were performed at 1 and 3 months and every 3 months thereafter. Results: After the first CPVI, 71 patients (71%) were free of AF without antiarrhythmic drug therapy (follow up:28±11 months). The only independent and significant predictors for freedom of AF after the first CPVI were duration of AF history and 3D LA volume (p<0.05). However, a significant overlap in durations of AF history and 3D LA volumes between failures and successes was observed. Conclusions: (1) Using the "circumferential pulmonary vein isolation" approach, the first catheter ablation leads to resolution of arrhythmia in ≈ 70% of symptomatic AF patients. (2) Independent predictors for freedom of AF after initial CPVI are duration of AF history and 3D LA volume. (3) Due to considerable overlap between failures and successes, these parameters can not be used to identify patients who should not undergo CPVI or in whom an additional ablation beyond CPVI is required. On the other hand, our results do suggest that an ablation strategy early in the course of AF disease can influence successful outcome.

8.
J Vet Intern Med ; 22(6): 1353-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19000247

RESUMO

BACKGROUND: In humans, atrial fibrillation (AF) induces electrical, contractile, and structural remodeling leading to AF stabilization. Little is known about AF-induced atrial remodeling in horses. HYPOTHESIS: Induced AF produces rapid atrial electrical and contractile remodeling in horses. ANIMALS: Six horses, 5 animals completed the study. METHODS: Each horse was instrumented with a pulse generator and pacemaker to maintain AF by burst pacing and to study atrial and ventricular electrophysiology (AF cycle length [AFCL], AF duration, and atrial/ventricular effective refractory period [AERP/VERP] at different pacing cycle lengths [PCL]). Left atrial and ventricular contractile remodeling were assessed echocardiographically by calculation of fractional changes in atrial and ventricular dimensions, respectively, during the cardiac cycle. Measurements were performed at baseline, a 7-day AF period and a 2-day recovery period. RESULTS: Atrial electrical and contractile remodeling could be demonstrated after 4 and 12 hours of AF, respectively. A progressive shortening of the AERP (261 +/- 39-171 +/- 18 ms at a PCL of 1,000 ms, P < .0001), an attenuation of the AERP rate adaptation, a decrease in AFCL (239 +/- 39-194 +/- 7 ms, P < .0001), and a decrease in atrial FS (12 +/- 3% to 0 +/- 2%, P < .05) occurred. AF duration increased progressively and became persistent in 2 animals. VERP did not change significantly. Upon restoration of sinus rhythm, values returned to baseline within 48 hours. CONCLUSIONS AND CLINICAL IMPORTANCE: Atrial electrical and contractile remodeling appears rapidly. After 7 days of AF, reverse remodeling occurred within 2 days. These observations suggest that early conversion of AF might be beneficial for success rate and early return to training.


Assuntos
Fibrilação Atrial/veterinária , Estimulação Cardíaca Artificial/veterinária , Doenças dos Cavalos , Contração Miocárdica/fisiologia , Remodelação Ventricular/fisiologia , Animais , Fibrilação Atrial/patologia , Estimulação Cardíaca Artificial/efeitos adversos , Cavalos , Fatores de Tempo
9.
Equine Vet J ; 39(4): 344-9, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17722727

RESUMO

REASON FOR PERFORMING STUDY: Good results have been obtained with a human amiodarone (AD) i.v. protocol in horses with chronic atrial fibrillation (AF) and a pharmacokinetic study is required for a specific i.v. amiodarone treatment protocol for horses. OBJECTIVES: To study the efficacy of this pharmacokinetic based i.v. AD protocol in horses with chronic AF. METHODS: Six horses with chronic AF were treated with an adapted AD infusion protocol. The protocol consisted of 2 phases with a loading dose followed by a maintenance infusion. In the first phase, horses received an infusion of 6.52 mg AD/kg bwt/h for 1 h followed by 1.1 mg/kg bwt/h for 47 h. In the second phase, horses received a second loading dose of 3.74 mg AD/kg bwt/h for 1 h followed by 1.31 mg/kg bwt/h for 47 h. Clinical signs were monitored, a surface ECG and an intra-atrial electrogram were recorded. AD treatment was discontinued when conversion or any side effects were observed. RESULTS: Three of the 6 horses cardioverted successfully without side effects. The other 3 horses did not convert and showed adverse effects, including diarrhoea. In the latter, there were no important circulatory problems, but the diarrhoea continued for 10-14 days. The third horse had to be subjected to euthanasia because a concomitant Salmonella infection worsened the clinical signs. CONCLUSION: The applied treatment protocol based upon pharmacokinetic data achieved clinically relevant concentrations of AD and desethylamiodarone. POTENTIAL RELEVANCE: Intravenous AD has the potential to be an alternative pharmacological treatment for AF in horses, although AD may lead to adverse drug effects, particularly with cumulative dosing.


Assuntos
Amiodarona/farmacocinética , Antiarrítmicos/farmacocinética , Fibrilação Atrial/veterinária , Doenças dos Cavalos/tratamento farmacológico , Amiodarona/administração & dosagem , Amiodarona/efeitos adversos , Animais , Antiarrítmicos/administração & dosagem , Antiarrítmicos/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Diarreia/induzido quimicamente , Diarreia/veterinária , Relação Dose-Resposta a Droga , Ecocardiografia/veterinária , Ecocardiografia Doppler em Cores/veterinária , Cavalos , Infusões Intravenosas/veterinária , Resultado do Tratamento
10.
Europace ; 9(8): 651-6, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17597078

RESUMO

AIMS: The aim of this study is to investigate the safety and effectiveness of Excimer laser-assisted lead extraction in Europe. The final European multi-centre study experience is presented. METHOD AND RESULTS: The Excimer is a cool cutting laser (50 degrees C) with a wavelength of 308 nm. The energy is emitted from the tip of a flexible sheath and is absorbed by proteins and lipids, 64% of the energy is absorbed at a tissue depth of 0.06 mm. The sheath is positioned over the lead, and the fibrosis surrounding the lead is vaporized while advancing the sheath without damaging other leads. From August 1996 to March 2001, 383 leads (170 atrial, 213 ventricular) in 292 patients (mean age 61.6 years, range 13-96) were extracted at 14 European centres. Mean implantation time was 74 months (3-358). Most frequent indications were pocket infection (26%), non-functional leads (21%), patient morbidity (21%), septicaemia or endocarditis (14%), erosion (5%), and lead interference (8%). Median extraction time was 15 min (1-300). Complete extraction was achieved in 90.9% of the leads and partial extraction in 3.4%. Extraction failed in 5.7% of the leads. Major complications = perforations caused 10/22 (3.4/5.7%) of the failures. Most partially extracted patients were considered clinically successful, as only minor lead parts without clinical significance were left. Femoral non-laser technique was used to remove 8/12 of the non-complication failures. The total complication rate, including five minor complications (1.7%), was 5.1%. No in-hospital mortality occurred. CONCLUSION: Pacing and implantable cardioverter-defibrillator leads can safely, effectively, and predictably be extracted. Open-heart extractions can be limited to special cases. The results indicate that the traditional policy of abandoning redundant leads, instead of removing them, may be obsolete in many patients.


Assuntos
Remoção de Dispositivo/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Terapia a Laser/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Medição de Risco/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Europa (Continente)/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco
11.
Vet J ; 172(1): 129-34, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15908245

RESUMO

Six horses without underlying cardiac disease were presented because of atrial fibrillation of between 5 and 12 months duration. These horses received an intravenous amiodarone treatment of 5mg/kg/h for 1 h followed by 0.83mg/kg/h for 23h and subsequently 1.9mg/kg/h for 30h. During treatment, clinical signs were monitored and a surface ECG and an intra-atrial electrogram were recorded. Infusion was discontinued when sinus rhythm or side effects occurred. Four horses successfully cardioverted, of which one showed symptoms of hind limb weakness and weight shifting. Two horses did not cardiovert and showed similar side effects. In all horses, side effects disappeared within 6h after termination of treatment. Cardiac side effects, such as pro-arrhythmia, were not seen in any of the horses. Total bilirubin slightly increased in three horses and normalised within four days. It was concluded that amiodarone has the potential to treat naturally occurring chronic atrial fibrillation in horses, although further research is needed to refine the infusion protocol.


Assuntos
Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/veterinária , Doenças dos Cavalos/tratamento farmacológico , Amiodarona/administração & dosagem , Animais , Fibrilação Atrial/tratamento farmacológico , Doença Crônica , Cavalos , Segurança , Resultado do Tratamento
12.
Int J Cardiol ; 112(1): 72-9, 2006 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-16316699

RESUMO

BACKGROUND: The internal cardioverter defibrillator (ICD) is increasingly used to treat ventricular tachyarrhythmias in patients with coronary artery disease (CAD). The burden of coronary risk factors and inflammation is however not well studied in these high risk patients. STUDY AIMS: The aim of the present study was to describe the prevalence of coronary risk factors (including lipid values) and inflammation (including high sensitive-C-reactive protein, hs-CRP) in patients with CAD and ICD implants. METHODS: Baseline clinical characteristics and laboratory results of all eligible patients for the Cholesterol Lowering and Arrhythmias Recurrences after Internal Defibrillator Implantation trial (CLARIDI trial) were used. All patients had documented CAD, an ICD implant and were not yet treated with statins. Coronary risk factors, lipid values, glycated haemoglobin (HbA(1c)) and hs-CRP levels were determined. RESULTS: In the 110 included patients (mean age 68+/-9 years, LVEF 40+/-17%, NYHA class II-III in 47%), a high prevalence of coronary risk factors was documented: current smoking in 18%, body mass index > or =30 kg/m(2) in 16%, blood pressure > or =140/90 mm Hg in 40%, history of diabetes in 12%, and HbA(1c) > or =6% in 16% of patients not known with diabetes. A total cholesterol >175 mg/dl was found in 76% of patients and an LDL cholesterol >100 mg/dl in 83%. Finally, median hs-CRP was 4.8 mg/l (interquartile range 2.5-13.9 mg/l). Hs-CRP values > or =2 mg/l were noted in 83% of all patients and in 68% of patients who had an ICD implant more than 6 months before inclusion. CONCLUSION: In CAD patients with ICD implants, the burden of coronary risk factors is high, often unrecognized and/or under-treated. Persistent inflammation is found in the majority of these patients.


Assuntos
Doença da Artéria Coronariana/sangue , Desfibriladores Implantáveis , Mediadores da Inflamação/sangue , Inflamação/sangue , Adulto , Idoso , Anticolesterolemiantes/uso terapêutico , Atorvastatina , Bélgica/epidemiologia , Biomarcadores/sangue , Proteína C-Reativa/metabolismo , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/epidemiologia , Método Duplo-Cego , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Grécia/epidemiologia , Ácidos Heptanoicos/uso terapêutico , Humanos , Lipídeos/sangue , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Prevalência , Pirróis/uso terapêutico , Projetos de Pesquisa , Fatores de Risco , Taquicardia Ventricular/sangue , Taquicardia Ventricular/terapia , Resultado do Tratamento , Fibrilação Ventricular/sangue , Fibrilação Ventricular/terapia
13.
Physiol Behav ; 86(4): 538-45, 2005 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-16181649

RESUMO

The circadian rhythm of core body temperature (Tb) was examined in two mouse lines bidirectionally selected for nest-building behavior (small (SNB) and big nest-builders (BNB)). This selection also resulted in more robust circadian organization of wheel-running activity in the SNB compared to the BNB mice. Tb was measured by an e-mitter implanted in the abdominal cavity. The circadian Tb rhythm of the SNB was more robust compared to the BNB regardless of whether the animals had access to a running wheel or not and regardless of the lighting conditions, i.e., 12 h:12 h light:dark (LD) cycle or constant dark (DD). Wheel-running activity rhythms of SNB were more robust in LD and DD compared to BNB. The amplitude of the circadian Tb rhythm increased significantly in response to wheel access in both mouse lines, but was not significantly different between the BNB and SNB. However, BNB tended to have lower amplitudes of circadian Tb rhythm in the absence of running wheels and a larger increase in the amplitude upon access to a running wheel compared to SNB. No differences were found in LD and DD between the lines in mean Tb and wheel-running activity levels. In addition, no differences between the two mouse lines were found in the free-running period of the Tb or wheel-running activity rhythms in DD. Overall, our findings reveal a more robust circadian phenotype of the SNB compared to the BNB.


Assuntos
Temperatura Corporal/fisiologia , Ritmo Circadiano/fisiologia , Comportamento de Nidação/fisiologia , Animais , Temperatura Corporal/genética , Peso Corporal , Cruzamento , Ritmo Circadiano/genética , Masculino , Camundongos , Atividade Motora/fisiologia , Fenótipo , Fotoperíodo , Especificidade da Espécie
14.
Vet J ; 170(1): 124-7, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15993796

RESUMO

Transvenous electrical cardioversion was attempted in a horse with drug refractory atrial fibrillation. A temporary pacing catheter and two defibrillation catheters were inserted transvenously into the right ventricular apex, the right atrium and the pulmonary artery, respectively. Under general anaesthesia 100, 200, 300 and 360 J monophasic shocks were delivered between both defibrillation catheters but sinus rhythm could not be restored. Immediately after the 200, 300 and 360 J shock, transient third-degree atrioventricular block occurred for a period of, respectively, 15, 40 and 55 s. These periods of profound bradycardia were corrected by temporary right ventricular pacing until spontaneous conduction resumed. It is concluded that temporary right ventricular pacing should be available during electrical cardioversion of atrial fibrillation in horses.


Assuntos
Fibrilação Atrial/veterinária , Cardioversão Elétrica/veterinária , Bloqueio Cardíaco/veterinária , Doenças dos Cavalos/terapia , Animais , Fibrilação Atrial/terapia , Diagnóstico Diferencial , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia/veterinária , Feminino , Bloqueio Cardíaco/diagnóstico , Bloqueio Cardíaco/etiologia , Cavalos
15.
Europace ; 5(1): 1-9, 2003 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12504634

RESUMO

BACKGROUND: The understanding of the onset mechanisms of paroxysmal atrial fibrillation (AF) may help to develop preventive therapy. Specific heart rate (HR) patterns and autonomic changes immediately before the onset of paroxysmal AF are not fully investigated. We undertook the present study to assess HR and heart rate variability (HRV) changes before the onset of AF using 24-h Holter electrocardiographic analysis in patients without antiarrhythmic medication. METHODS AND RESULTS: In 27 patients, 48 episodes of AF, lasting more than 30s and preceded by sinus rhythm for more than 1h were analysed. The hour preceding AF was divided in 5- and 30 min blocks. HR was also analysed in the last 15 beats. In 21% of the episodes, HR decreased >or=5% in the last 5 min (defined as deceleration); it increased >or=5% in 37% (defined as acceleration). HR, standard deviation (SD) and SD corrected for RR interval changed significantly in the last 5 min in the total group. Acceleration and deceleration were already visible over 30-min blocks in both these subgroups; changes in SD were only seen in the accelerators. The number of atrial premature beats (PACs) increased before AF, most clearly in the accelerators. Spectral HRV analysis revealed no additional information. CONCLUSIONS: Changes in HR, SD, and an increased number of PACs herald AF from at least 30 min before onset, more pronounced in accelerators. Spectral HRV parameters are not useful to foresee AF onset. This has possible implications for device therapy.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia Ambulatorial , Frequência Cardíaca/fisiologia , Complexos Atriais Prematuros/fisiopatologia , Sistema Nervoso Autônomo/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo
16.
Vet Rec ; 151(18): 541-5, 2002 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-12448492

RESUMO

A five-year-old gelding suffered syncope at the end of a period of exercise. A 24-hour electrocardiogram recording revealed intermittent pauses in the sinus rhythm of up to 10 seconds, indicating sinus node disease; the pauses occurred repeatedly, particularly after exercise. A dual-chamber, rate-adaptive pacemaker was successfully implanted, which prevented excessive postexercise bradycardia and syncope, and allowed the horse to return to work.


Assuntos
Doenças dos Cavalos/terapia , Marca-Passo Artificial/veterinária , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/veterinária , Animais , Bradicardia/etiologia , Bradicardia/prevenção & controle , Bradicardia/veterinária , Cavalos , Masculino , Condicionamento Físico Animal , Síncope/etiologia , Síncope/prevenção & controle , Síncope/veterinária
17.
Vet J ; 164(2): 142-50, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12359469

RESUMO

We describe the development and the different features of an experimental model of chronic atrial fibrillation (AF) in equines. In four healthy ponies a dual-chamber pacemaker, with an adapted pacemaker program, was implanted transvenously in the standing animal. This adapted pacemaker induced episodes of AF by delivering a 2s burst of electrical stimuli (42 Hz) as soon as sinus rhythm was detected. Simultaneous with a surface electrocardiogram, the intra-atrial electrogram could be recorded to determine the atrial electrogram morphology. Programmed electrical stimulation (PES) was used to determine the atrial effective refractory period (AERP) and the rate adaptation of the AERP, the sinus node recovery time (SNRT) and the corrected SNRT, AF vulnerability, AF cycle length and AF duration. This experimental AF model can be used to study the pathophysiology of chronic AF in equines.


Assuntos
Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/veterinária , Modelos Animais de Doenças , Cavalos , Animais , Estimulação Cardíaca Artificial , Doença Crônica , Estimulação Elétrica , Eletrocardiografia , Frequência Cardíaca , Doenças dos Cavalos/fisiopatologia , Marca-Passo Artificial/veterinária
18.
Eur Heart J ; 22(14): 1214-25, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11440494

RESUMO

AIMS: The purpose of this study was to assess risk factors for sudden death after discharge from hospital for myocardial infarction in an era in which 50% of patients receive thrombolytic drugs. METHODS AND RESULTS: We prospectively studied 708 consecutive survivors of myocardial infarction admitted to hospitals, which had registered their clinical, functional, and electrical parameters. A total of 83 patients died in the first 2 years (12%) after discharge. Sudden death was only observed in 12 patients. In multivariate analysis only NYHA class >I, and a filtered QRS duration > or =110 ms were important predictive variables for sudden death. A pre-defined high-risk group of 25 patients had no sudden death. When the strongest predictive variables in univariate analysis were combined to increase the positive predictive value for sudden death, we only achieved a maximal value of 27%. CONCLUSIONS: In an unselected infarction population, the risk for sudden death is low in the first 2 years. Therefore, prediction and prophylactic intervention, such as defibrillator therapy become difficult. The event is related to cardiac dysfunction on admission, and with abnormalities in the filtered electrocardiogram.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Eletrocardiografia , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/mortalidade , Alta do Paciente/estatística & dados numéricos , Terapia Trombolítica , Adulto , Idoso , Idoso de 80 Anos ou mais , Bélgica/epidemiologia , Morte Súbita Cardíaca/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Valor Preditivo dos Testes , Prevalência , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Análise de Sobrevida
19.
Heart ; 85(1): 53-6, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11119463

RESUMO

OBJECTIVE: To study the outcome of patients with arrhythmogenic right ventricular dysplasia treated with an implantable cardioverter-defibrillator (ICD) for ventricular tachyarrhythmias complicated by haemodynamic collapse. DESIGN: Observational study. SETTING: University hospital. PATIENTS: Nine consecutive patients (eight male, one female; mean (SD) age, 36 (18) years) with arrhythmogenic right ventricular dysplasia presenting with ventricular tachycardia and haemodynamic collapse (n = 6) or ventricular fibrillation (n = 3), treated with an ICD. MAIN OUTCOME MEASURES: Survival; numbers of and reasons for appropriate and inappropriate ICD interventions. RESULTS: After a mean (SD) follow up of 32 (24) months, all patients were alive. Six patients received a median of 19 (range 2-306) appropriate ICD interventions for events detected in the ventricular tachycardia window; four received a median of 2 (range 1-19) appropriate ICD interventions for events detected in the ventricular fibrillation window. Inappropriate interventions were seen for sinus tachycardia (18 episodes in three patients), atrial fibrillation (three episodes in one patient), and for non-sustained polymorphic ventricular tachycardia (one episode in one patient). CONCLUSIONS: Patients with arrhythmogenic right ventricular dysplasia and malignant ventricular arrhythmias have a high recurrence rate requiring appropriate ICD interventions, but they also often have inappropriate interventions. Programming the device is difficult because this population develops supraventricular and ventricular tachyarrhythmias with similar rates.


Assuntos
Displasia Arritmogênica Ventricular Direita/terapia , Desfibriladores Implantáveis , Adulto , Arritmias Cardíacas/complicações , Arritmias Cardíacas/terapia , Displasia Arritmogênica Ventricular Direita/complicações , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva
20.
J Vet Intern Med ; 15(6): 564-71, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11817062

RESUMO

The purpose of the present study was to develop a feasible and safe technique for dual-chamber pacemaker implantation in healthy horses. Implantation was performed in a standing, tranquilized horse and in ponies. Atrial and ventricular leads were transvenously inserted through the cephalic vein, and a subcutaneous pacemaker pocket was created between the lateral pectoral groove and the manubrium sterni in 6 equids. Positioning of each lead was guided by echocardiography and by measuring the electrical characteristics of the lead. The implantation procedure lasted about 4 hours in each animal and was well tolerated. In all animals, dual-chamber pacemaker function was obtained, and these results remained good throughout the follow-up period. At the time of implantation, atrial and ventricular sensing were between 2.1 and 7.2 mV and 7.8 and 16.8 mV, respectively, and atrial and ventricular pacing thresholds at 0.5 millisecond varied from 0.5 to 0.7 V and from 0.3 to 1.0 V, respectively. Six months after the implantation, sensing values varied from 2 to 10 mV for the atrial lead and from 2 to 16 mV for the ventricular lead, while pacing thresholds at 0.5 millisecond varied from less than 0.5 to 2.5 V for the right atrium and from less than 0.5 to 5.0 V for the right ventricle. Atrial lead dislodgment occurred in 2 animals, requiring insertion of a new lead. Ventricular lead dislodgment was not observed.


Assuntos
Arritmias Cardíacas/veterinária , Doenças dos Cavalos/terapia , Cavalos/fisiologia , Marca-Passo Artificial/veterinária , Animais , Arritmias Cardíacas/terapia , Ecocardiografia/veterinária , Estudos de Viabilidade , Átrios do Coração , Ventrículos do Coração , Masculino , Pescoço/irrigação sanguínea , Implantação de Prótese , Veias/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...