Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Interv Card Electrophysiol ; 60(1): 135-146, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32144678

RESUMO

PURPOSE: Identification of a conduction gap between the left atrium and pulmonary vein (LA-PV gap) and the circuit of atrial tachycardia after pulmonary vein isolation (PVI) is an important process during the second ablation for atrial fibrillation (AF). The high-density mapping system RHYTHMIA® is useful for identification of an LA-PV gap and the circuit of atrial tachycardia. Therefore, this study was performed to investigate the effect of RHYTHMIA® in terms of the outcome of the second ablation for AF. METHODS: One hundred patients underwent a second ablation for AF in our institute from April 2015 to December 2018. We retrospectively evaluated 49 patients using RHYTHMIA® (group 1) and 51 patients using the conventional method with additional anatomical guide by CARTO® system. RESULTS: In group 1, we performed redo PVI for 41 patients with 49 LA-PV countable gaps and ablation for other atrial arrhythmias in 7 patients. In group 2, we performed redo PVI in 40 patients with 33 LA-PV countable gaps and ablation for other atrial arrhythmias in 9 patients. Three and two unstable arrhythmias in each group were not ablated. The final recurrence of atrial arrhythmia was significantly lower in group 1 than 2 (8/49 (16%) vs. 17/51 (33%), respectively; P = 0.017). Atrial arrhythmias other than AF after the second ablation occurred in only one patient in group 1 but seven patients in group 2. CONCLUSION: Using high-density mapping for the second ablation of AF was found to be superior to the conventional ablation method in terms of the suppression of atrial events in this study. This technique warrants further investigation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
2.
Int Heart J ; 61(5): 913-921, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32921668

RESUMO

Previous study has identified marked differences in patient characteristics and causes of inappropriate shock (IAS) between Japan and the Western societies in terms of subcutaneous implantable cardioverter-defibrillator (S-ICD). However, evidence of IAS in Asian populations including Japan has been limited to one observational study.Thus, we conducted a single-center registry study that tracks the postoperative course of 61 consecutive patients who received S-ICD from February 2016 to January 2020. Our findings showed that IAS occurred in 9.8% of the study population (6/61), which is comparable to the previously reported incidence. Remarkably, T-wave oversensing did not result in an IAS (0/6). Instead, myopotential oversensing was determined to have caused the most IAS events (4/6), while atrial fibrillation ranked second (2/6). A provocation maneuver (e.g., abdominal clench, push-ups, lifting a heavy item) reproduced myopotential noise disguised as R-waves, which should potentially trigger an IAS if uninterrupted. R-wave amplitude of the IAS group appeared relatively low compared to that of the non-IAS group although this finding was not tested significant. Furthermore, no temporal changes were noted in R-wave amplitude between the time of implantation and IAS events, suggesting that it is neither constantly low nor acutely dropped R-wave amplitude but a relatively high noise level that drives IAS. All the myopotential-IAS patients were found to be male. Right-sided lead implantation was associated with a higher incidence of IAS.This study highlights the fact that IAS continues to occur due to myopotential noise oversensing instead of T-wave oversensing. To minimize the risk of IAS, it is desirable to search and secure high R-wave voltage.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Músculo Esquelético/fisiologia , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Adolescente , Adulto , Idoso , Criança , Erros de Diagnóstico , Falha de Equipamento , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...