Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Appl Biochem Biotechnol ; 186(4): 1034-1046, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29808455

RESUMO

Cystic fibrosis (CF) is a severe autosomal recessive disorder. It is caused by mutations in the CF transmembrane conductance regulator gene. Early diagnosis of CF can be carried out by determining high immunoreactive trypsinogen (IRT) blood values in newborns. A simple sandwich-type ultramicroELISA assay (UMELISA®) has been developed for the measurement of IRT in dried blood spots on filter paper. Strips coated with a high affinity monoclonal antibody directed against IRT are used as solid phase, to ensure the specificity of the assay. The assay is carried out within 20 h. The useful rank of the curve is 0-500 ng/mL, and the lowest detectable concentration is 4.8 ng/mL. Intra- and inter-assay coefficients of variation were lower than 10%. The recovery mean value was 100.3 ± 11.2%. Cross-reactivity with proteins structurally related to IRT (α2-macroglobulin, α1-antitrypsin, and human chymotrypsin) was lower than the detection limit of the assay. Four thousand four hundred six newborn samples from the Cuban Newborn Screening Program were analyzed, and the mean IRT concentration was 12.8 ng/mL. Higher IRT values were obtained when samples were eluted overnight. Regression analysis showed a good correlation with the commercially available AutoDELFIA® Neonatal IRT kit (n = 3948, r = 0.885, ƙ = 0.976, p < 0.01). The analytical performance characteristics of our UMELISA® TIR Neonatal suggest that it can be used for the neonatal screening of CF.


Assuntos
Fibrose Cística/sangue , Teste em Amostras de Sangue Seco/métodos , Papel , Tripsinogênio/sangue , Reações Cruzadas , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Sensibilidade e Especificidade , Tripsinogênio/análise
2.
J Immunoassay Immunochem ; 39(1): 30-42, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29144197

RESUMO

Congenital hypothyroidism is one of the most common preventable causes of mental retardation. The Center of Immunoassay has developed the UMELISA® T4 NEONATAL and UMELISA® T4 to determine neonatal T4 levels in dried blood and serum samples. Both reagent kits use the same polystyrene plates coated with anti-thyroxine (T4) polyclonal antibodies as solid phase. This work shows the re-standardization of the UMELISA® T4 NEONATAL and UMELISA® T4 using plates coated with anti-T4 monoclonal antibodies (T4Mabs). Polystyrene plates of the modified assays were firstly coated with polyclonal IgG sheep-anti-mouse IgG for 18 hours. T4Mabs were added to the plates and incubated for 2 hours at room temperature. Different performance parameters were evaluated and correlation studies with the commercial kits done. Using polystyrene plates coated with T4Mabs increases the slope of the calibration curve in the clinical interest zone. The assay conjugates work twice diluted in respect to the ones of the commercial kits. Recovery percentages (90.8-110.7 for UMELISA® T4 NEONATAL and 92.1-109.3 for UMELISA® T4) and intra (7.2-7.6 for UMELISA® T4 NEONATAL and 6.9-7.2 for UMELISA® T4) and inter (7.4-8.5 for UMELISA® T4 NEONATAL and 7.1-8.5 for UMELISA® T4) coefficients of variation were similar to the ones described for the commercial kits. Limits of detection and quantification were 9.0 and 21.1 nmol/L for UMELISA® T4 NEONATAL, and 8.9 and 20.5 nmol/L for UMELISA® T4, respectively. The results also showed high overall concordance between assays (n = 244, r = 0.92, ρc = 0.91 for UMELISA® T4 NEONATAL and n = 492, r = 0.92, ρc = 0.9 for UMELISA® T4). The analytical sensibility of UMELISA® T4 NEONATAL and UMELISA® T4 is improved by using polystyrene plates coated with T4Mabs, without affecting the precision and accuracy of the results. ABBREVIATIONS: T4: L-Thyroxine; ELISA: Enzyme-linked immunosorbent assay; SUMA: Ultra Micro Analytic System; UMELISA: Ultramicro enzyme-linked immunosorbent assay; TSH: Thyroid-stimulating hormone.


Assuntos
Anticorpos Monoclonais/química , Anticorpos Monoclonais/imunologia , Ensaio de Imunoadsorção Enzimática/instrumentação , Ensaio de Imunoadsorção Enzimática/normas , Poliestirenos/química , Tiroxina/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos
3.
J. inborn errors metab. screen ; 4: e160014, 2016. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1090887

RESUMO

Abstract The ultramicroanalytic system (SUMA), created in the 1980s, is a complete system of reagents and instrumentation to perform ultramicroassays combining the sensitivity of the micro-enzyme-linked immunosorbent assay (ELISA) tests with the use of ultramicrovolumes. This technology permitted establishing large-scale newborn screening programs (NSPs) for metabolic and endocrine disorders in Cuba. This article summarizes the main results of the implementation during the 30 years of SUMA technology in NSP for 5 inherited metabolic diseases, using ultramicroassays developed at the Department of Newborn Screening at the Immunoassay Center. Since 1986, SUMA technology has been used in the Cuban NSP for congenital hypothyroidism, initially studying thyroid hormone in cord serum samples. In 2000, a decentralized program for the detection of hyperphenylalaninemias using heel dried blood samples was initiated. These successful experiences permitted including protocols for screening congenital adrenal hyperplasia, galactosemia, and biotinidase deficiency in 2005. A program for the newborn screening of CH using the thyroid-stimulating hormone Neonatal ultramicro-ELISA was fully implemented in 2010. Nowadays, the NSP is supported by a network of 175 SUMA laboratories. After 30 years, more than 3.8 million Cuban newborns have been screened, and 1002 affected children have been detected. Moreover, SUMA technology has been presented in Latin America for over 2 decades and has contributed to screen around 17 million newborns. These results prove that developing countries can develop appropriate diagnostic technologies for making health care accessible to all.

4.
Clin Chim Acta ; 421: 73-8, 2013 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-23481450

RESUMO

BACKGROUND: Since 2005, a newborn screening program for congenital adrenal hyperplasia (CAH) by measuring 17-alpha-hydroxyprogesterone (17OHP) in dried blood spots was introduced in Cuba. METHODS: The hormone was measured by the 17OHP Neonatal UMELISA method, in samples collected on the 5th day as average. Confirmatory test was performed to those neonates with 17OHP values above 55 nmol/l. Some perinatal factors that can influence on 17OHP levels were studied. RESULTS: From January 2005 to December 2010, 621,303 newborns were screened and 39 CAH cases were detected. Coverage of the program reached 98%. The incidence of CAH in Cuba was 1:15,931, similar to that reported by other programs. A recall for suspected CAH was performed in 10,799 cases (1.74%). Therapy in classical CAH patients was started at the mean age of 22 days. 17OHP levels were significantly higher in newborns with lower birth-weight (BW) and/or gestational age (GA). In addition, 17OHP values were affected by the gender, twin status or mode of delivery. CONCLUSIONS: In Cuba, the nationwide newborn screening program has allowed the early detection of CAH. The use of an optimized cut-off level for BW or GA could lead to a reduction in the percentage of recalled babies.


Assuntos
17-alfa-Hidroxiprogesterona/sangue , Hiperplasia Suprarrenal Congênita/sangue , Hiperplasia Suprarrenal Congênita/diagnóstico , Triagem Neonatal , Hiperplasia Suprarrenal Congênita/epidemiologia , Peso ao Nascer , Cuba/epidemiologia , Teste em Amostras de Sangue Seco , Diagnóstico Precoce , Feminino , Idade Gestacional , Humanos , Incidência , Lactente , Recém-Nascido , Masculino
5.
J Perinat Med ; 39(1): 77-81, 2011 01.
Artigo em Inglês | MEDLINE | ID: mdl-21171942

RESUMO

BACKGROUND: To describe a simple, rapid, quantitative ultramicrotest (UMTEST) based on the fluorometric method introduced by Fujimura et al. adapted to an Ultra Micro Analytic System (SUMA) for the detection of total galactose (GAL) in dried blood specimens. METHODS: The assay uses 3 mm discs of dried blood on Whatman 903 filter paper and small volumes of each reagent. A methanol/acetone/water solution is used for deproteination, and a specially designed 96-well polystyrene opaque ultramicroplates, with a maximum capacity of 30 µL per well, are used for the reading. RESULTS: The UMTEST GAL is completed in 2 h, with measuring range of 0.28-3.92 mmol/L. The intra- and inter-assay coefficients of variation were 2.3%-8.9% and 6.8%-11.1%, respectively, depending on the total GAL concentrations. Percentage recovery ranged from 97.7% to 103%. Limit of detection and limit of quantitation were 0.06 and 0.16 mmol/L, respectively. The mean GAL concentration, in 2510 dried blood samples from the National Neonatal Screening Program was 0.23 mmol/L. Our assay showed high concordance correlations with the commercially available ICN Immuno-Chem™ GAL-MW EA kit. CONCLUSIONS: The analytical performance characteristics of this assay is suitable for mass newborn screening of galactosemia in Cuba.


Assuntos
Galactosemias/diagnóstico , Recém-Nascido/sangue , Triagem Neonatal/métodos , Cuba , Fluorometria/métodos , Galactosemias/sangue , Humanos , Microquímica , Padrões de Referência , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...