Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Radiol ; 75(10): 798.e13-798.e22, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32723501

RESUMO

AIM: The aim of this study was to evaluate the robustness of radiomics features of a MRI (magnetic resonance imaging) phantom in quantitative diffusion-weighted imaging (DWI) and depending on the image resolution. MATERIALS AND METHODS: Scanning of an in-house developed DWI phantom was performed at a 1.5 T MRI scanner (Magnetom AERA, Siemens, Erlangen, Germany) using an echo planar imaging (EPI) DWI sequence (b=0,500,1,000 s/mm2) with low (3×3 mm2) and high (2×2 mm2) image resolutions. Scans were repeated after phantom repositioning to evaluate retest reliability. Radiomics features were extracted after semi-automatic segmentation and standardised pre-processing. Intra-/interobserver reproducibility and test-retest robustness were assessed using intraclass correlation coefficients (ICC). Differences were tested with non-parametric Wilcoxon's signed-rank and Friedman's test (p < 0.05) with Dunn's post-hoc analysis. RESULTS: Test-retest ICC was overall high with >0.90 for 39/46 radiomics features in all sequences/resolutions. Decreased test-retest ICCs were pronounced for conventional Min-value (overall ICC=0.817), and grey-level zone length matrix (GLZLM) features Short-Zone Emphasis (SZE) and Short-Zone Low Grey-level Emphasis (SZLGE) (for both overall ICC=0.927). Test-retest reproducibility was significantly different between b=500, 1,000 and apparent diffusion coefficient (ADC) (mean 0.975±0.050, 0.974±0.051 and 0.966±0.063), which remained significant after post-hoc analysis between b=1,000 and ADC (p = 0.022). ICCs were not significantly different between resolutions of 2×2 and 3×3 mm2 regarding b=500 (mean: 0.977±0.052 and 0.974±0.049, p = 0.612), b=1,000 (mean: 0.973±0.059 and 0.974±0.054, p = 0.516), and ADC (mean: 0.972±0.049 and 0.955±0.101, p = 0.851). Inter- and intra-observer reliability was consistently high for all sequences (overall mean 0.992±0.021 and 0.990±0.028). CONCLUSION: Under ex-vivo conditions, DWI provided robust radiomics features with those from ADC being slightly less robust than from raw DWI (b=500, 1,000 s/mm2). No significant difference was detected for different resolutions. Although, ex-vivo reliability of DWI radiomics features was high, no implications can be made regarding in-vivo analyses.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador , Imagem Ecoplanar , Humanos , Aumento da Imagem , Imagens de Fantasmas , Reprodutibilidade dos Testes
2.
Phys Med ; 41: 5-12, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28499627

RESUMO

PURPOSE: Three MOSkins dosimeters were assembled over a rectal probe and used to perform in vivo dosimetry during HDR brachytherapy treatments of vaginal cancer. The purpose of this study was to verify the applicability of the developed tool to evaluate discrepancies between planned and measured doses to the rectal wall. MATERIALS AND METHODS: MOSkin dosimeters from the Centre for Medical Radiation Physics are particularly suitable for brachytherapy procedures for their ability to be easily incorporated into treatment instrumentation. In this study, 26 treatment sessions of HDR vaginal brachytherapy were monitored using three MOSkin mounted on a rectal probe. A total of 78 measurements were collected and compared to doses determined by the treatment planning system. RESULTS: Mean dose discrepancy was determined as 2.2±6.9%, with 44.6% of the measurements within ±5%, 89.2% within ±10% and 10.8% higher than ±10%. When dose discrepancies were grouped according to the time elapsed between imaging and treatment (i.e., group 1: ≤90min; group 2: >90min), mean discrepancies resulted in 4.7±3.6% and 7.1±5.0% for groups 1 and 2, respectively. Furthermore, the position of the dosimeter on the rectal catheter was found to affect uncertainty, where highest uncertainties were observed for the dosimeter furthest inside the rectum. CONCLUSIONS: This study has verified MOSkin applicability to in-patient dose monitoring in gynecological brachytherapy procedures, demonstrating the dosimetric rectal probe setup as an accurate and convenient IVD instrument for rectal wall dose verification. Furthermore, the study demonstrates that the delivered dose discrepancy may be affected by the duration of treatment planning.


Assuntos
Braquiterapia , Dosimetria in Vivo , Dosímetros de Radiação , Reto/efeitos da radiação , Neoplasias Vaginais/radioterapia , Feminino , Humanos , Radiometria , Dosagem Radioterapêutica
3.
Appl Radiat Isot ; 83 Pt C: 222-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23810727

RESUMO

MOSkin detectors were studied to perform real-time in vivo dose measurements in high dose rate prostate brachytherapy. Measurements were performed inside an urethral catheter in a gel phantom simulating a real prostate implant. Measured and expected doses were compared and the discrepancy was found to be within 8.9% and 3.8% for single MOSkin and dual-MOSkin configurations, respectively. Results show that dual-MOSkin detectors can be profitably adopted in prostate brachytherapy treatments to perform real-time in vivo dosimetry inside the urethra.


Assuntos
Braquiterapia , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Estudos de Viabilidade , Humanos , Masculino
4.
J Gravit Physiol ; 9(1): P351-2, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15002610

RESUMO

The experiment proposed by Prof. Ricci University of Milan is funded by ASI with Laben as industrial Prime Contractor. ACS-EH (Automated Culture System-Experiment Hardware) will support the multigenerational experiment on weightlessness with rotifers and nematodes within four Experiment Containers (ECs) located inside the European Modular Cultivation System (EMCS) facility..Actually the Phase B is in progress and a concept design solution has been defined. The most challenging aspects for the design of such hardware are, from biological point of view the provision of an environment which permits animal's survival and to maintain desiccated generations separated and from the technical point of view, the miniaturisation of the hardware itself due to the reduce EC provided volume (160mmx60mmx60mm). The miniaturisation will allow a better use of the available EMCS Facility resources (e.g. volume. power etc.) and to fulfil the experiment requirements. ACS-EH, will be ready to fly in the year 2005 on boar the ISS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA