Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Mil Med ; 180(9): 937-42, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26327544

RESUMO

Dengue fever occurs in localized outbreaks and can significantly erode troop strength and mission readiness. Timely identification of dengue virus (DENV) provides for rapid and appropriate patient management decisions, such as medical evacuation and supportive therapies, as well as help to promote Force Health Protection through vector control and personal protective measures. The "Ruggedized" Advanced Pathogen Identification Device is a field-friendly PCR (Polymerase Chain Reaction) platform that can be used to facilitate early identification of DENV. We developed a dry-format PCR assay on this platform. The assay demonstrated 100% analytical specificity for detecting dengue using a cross-reactivity panel. We used a panel of 102 acute, DENV isolation positive serum samples and 25 DENV negative samples; the assay demonstrated a clinical sensitivity of 97.1% (95% C.I. 91.6-99.4%) and specificity of 96.0% (95% C.I. 79.7-99.9%) in identifying patients with dengue infection. We also used the assay to test mosquito homogenates from 28 adult female Aedes aegypti. A single DENV infected mosquito was identified using the PCR assay and confirmed using immunofluorescence as a reference method. Much of the testing was performed under austere field conditions. Together, our results demonstrate the utility of this assay for detecting DENV in vector and human samples in field environments.


Assuntos
Aedes/virologia , Vírus da Dengue/isolamento & purificação , Dengue/virologia , Medicina Militar/instrumentação , Reação em Cadeia da Polimerase/instrumentação , Animais , Dengue/sangue , Vírus da Dengue/genética , Vetores de Doenças , Feminino , Humanos , Medicina Militar/métodos , Unidades Móveis de Saúde , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Estados Unidos
2.
J AOAC Int ; 95(3): 860-91, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22816278

RESUMO

The RAZOR EX Anthrax Air Detection System, developed by Idaho Technology, Inc. (ITI), is a qualitative method for the detection of Bacillus anthracis spores collected by air collection devices. This system comprises a DNA extraction kit, a freeze-dried PCR reagent pouch, and the RAZOR EX real-time PCR instrument. Each pouch contains three assays, which distinguish potentially virulent B. anthracis from avirulent B. anthracis and other Bacillus species. These assays target the pXO1 and pXO2 plasmids and chromosomal DNA. When all targets are detected, the instrument makes an "anthrax detected" call, meaning that virulence genes of the anthrax bacillus are present. This report describes results from AOAC Method Developer (MD) and Independent Laboratory Validation (ILV) studies, which include matrix, inclusivity/exclusivity, environmental interference, upper and lower LOD of DNA, robustness, product consistency and stability, and instrument variation testing. In the MD studies, the system met the acceptance criteria for sensitivity and specificity, and the performance was consistent, stable, and robust for all components of the system. For the matrix study, the acceptance criteria of 95/96 expected calls was met for three of four matrixes, clean dry filters being the exception. Ninety-four of the 96 clean dry filter samples tested gave the expected calls. The nucleic acid limit of detection was 5-fold lower than AOAC's acceptable minimum detection limit. The system demonstrated no tendency for false positives when tested with Bacillus cereus. Environmental substances did not inhibit accurate detection of B. anthracis. The ILV studies yielded similar results for the matrix and inclusivity/exclusivity studies. The ILV environmental interference study included environmental substances and environmental organisms. Subsoil at a high concentration was found to negatively interfere with the pXO1 reaction. No interference was observed from the environmental organisms. The nucleic acid LOD, however, was 10 times higher (1 pg/reaction, equivalent to about 200 spores) than that found in the MD study. These results indicate that the RAZOR System is a sensitive and specific system that accurately identifies B. anthracis in aerosol matrixes and in the presence of interfering substances, and that the method can be performed by an independent laboratory and achieve similar results.


Assuntos
Microbiologia do Ar , Bacillus anthracis/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Bacillus anthracis/genética , DNA Bacteriano/análise , Limite de Detecção , Reação em Cadeia da Polimerase/instrumentação , Kit de Reagentes para Diagnóstico , Esporos Bacterianos/isolamento & purificação
3.
PLoS One ; 6(10): e26047, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22039434

RESUMO

The ideal clinical diagnostic system should deliver rapid, sensitive, specific and reproducible results while minimizing the requirements for specialized laboratory facilities and skilled technicians. We describe an integrated diagnostic platform, the "FilmArray", which fully automates the detection and identification of multiple organisms from a single sample in about one hour. An unprocessed biologic/clinical sample is subjected to nucleic acid purification, reverse transcription, a high-order nested multiplex polymerase chain reaction and amplicon melt curve analysis. Biochemical reactions are enclosed in a disposable pouch, minimizing the PCR contamination risk. FilmArray has the potential to detect greater than 100 different nucleic acid targets at one time. These features make the system well-suited for molecular detection of infectious agents. Validation of the FilmArray technology was achieved through development of a panel of assays capable of identifying 21 common viral and bacterial respiratory pathogens. Initial testing of the system using both cultured organisms and clinical nasal aspirates obtained from children demonstrated an analytical and clinical sensitivity and specificity comparable to existing diagnostic platforms. We demonstrate that automated identification of pathogens from their corresponding target amplicon(s) can be accomplished by analysis of the DNA melting curve of the amplicon.


Assuntos
Infecções Respiratórias/microbiologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Humanos
4.
Nucleic Acids Res ; 36(10): 3401-8, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18448472

RESUMO

Genotyping by high-resolution melting analysis of small amplicons is homogeneous and simple. However, this approach can be limited by physical and chemical components of the system that contribute to intersample melting variation. It is challenging for this method to distinguish homozygous G::C from C::G or A::T from T::A base-pair neutral variants, which comprise approximately 16% of all human single nucleotide polymorphisms (SNPs). We used internal oligonucleotide calibrators and custom analysis software to improve small amplicon (42-86 bp) genotyping on the LightScanner. Three G/C (PAH c.1155C>G, CHK2 c.1-3850G>C and candidate gene BX647987 c.261+22,290C>G) and three T/A (CPS1 c.3405-29A>T, OTC c.299-8T>A and MSH2 c.1511-9A>T) human single nucleotide variants were analyzed. Calibration improved homozygote genotyping accuracy from 91.7 to 99.7% across 1105 amplicons from 141 samples for five of the six targets. The average T(m) standard deviations of these targets decreased from 0.067 degrees C before calibration to 0.022 degrees C after calibration. We were unable to generate a small amplicon that could discriminate the BX647987 c.261+22,290C>G (rs1869458) SNP, despite reducing standard deviations from 0.086 degrees C to 0.032 degrees C. Two of the sites contained symmetric nearest neighbors adjacent to the SNPs. Unexpectedly, we were able to distinguish these homozygotes by T(m) even though current nearest neighbor models predict that the two homozygous alleles would be identical.


Assuntos
Homozigoto , Polimorfismo de Nucleotídeo Único , Análise de Sequência de DNA/métodos , Pareamento de Bases , Calibragem , Genótipo , Humanos , Desnaturação de Ácido Nucleico , Oligonucleotídeos/química , Reação em Cadeia da Polimerase , Análise de Sequência de DNA/normas
5.
Virology ; 313(1): 170-83, 2003 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-12951031

RESUMO

Cell culture-based transdominant genetic techniques provide new methods for discovering peptide/RNA modulators of cellular pathways. We applied this technology to isolate a peptide inhibitor of human rhinovirus. A green fluorescent protein (GFP)-scaffolded library of cDNA fragments was expressed in HeLa cells from a retroviral vector and screened for inhibitors of rhinovirus-mediated cell killing. A DNA clone, I421, increased cell survival in an HRV14 challenge assay from less than 0.5% to greater than 60%. It encodes a 53-amino-acid C-terminal extension of the GFP scaffold. Particular subclones of Hela cells expressing I421 (exemplified by I421dp3) show a delay in virus production and a 50-fold decrease in viral RNA levels at 6-8 h postinfection. HRV2, HRV14, and HRV16 show a dramatic decrease in plaque-forming ability on I421dp3 while Coxsackievirus B3 showed a small reduction. Levels of ICAM-1, the receptor for the main rhinovirus serotype, are not altered in I421dp3.


Assuntos
Antivirais/genética , Peptídeos/genética , Rhinovirus/efeitos dos fármacos , Sequência de Aminoácidos , Antivirais/isolamento & purificação , Antivirais/farmacologia , Sequência de Bases , Clonagem Molecular/métodos , Efeito Citopatogênico Viral/efeitos dos fármacos , DNA Complementar/biossíntese , DNA Complementar/genética , Desenho de Fármacos , Avaliação Pré-Clínica de Medicamentos/métodos , Biblioteca Gênica , Vetores Genéticos , Células HeLa , Humanos , Dados de Sequência Molecular , Peptídeos/isolamento & purificação , Peptídeos/farmacologia , Placenta/química , Retroviridae/genética , Rhinovirus/fisiologia , Transfecção , Replicação Viral/efeitos dos fármacos
6.
Genetics ; 163(3): 1047-60, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12663543

RESUMO

We used a genetic screening methodology, a human cell line bearing a retinoic-acid-responsive enhanced GFP reporter, and a flow sorter to recover dominant modulators of reporter expression. Four inducers and three suppressors that were fused to the C terminus of a protein scaffold for stability were isolated and their mechanisms of action studied. Mutagenesis experiments indicated that six of these dominant agents exerted their effects at the protein level. The single cDNA coding fragment that was isolated comprised the central 64-amino-acid section of human cyclophilin B, which contained its peptidyl-prolyl isomerase domain; this cyclophilin fragment repressed expression of the retinoic-acid-responsive reporter. The remaining clones encoded peptides shorter than 30 amino acids unrelated to known gene open reading frames. Genetic epistasis studies between the strongest inducer, R3, and a dominant-negative mutant of RARalpha suggest that the two factors function in the same pathway. Transcript microarray analyses suggest that R3 induced a subset of the retinoid-responsive genes in melanoma cells. Finally, yeast two-hybrid assays and co-immunoprecipitation studies of human cell extracts identified PAT1 as a protein that interacts with R3.


Assuntos
Testes Genéticos/métodos , Receptores do Ácido Retinoico/genética , Seleção Genética , Regiões 5' não Traduzidas/genética , Sequência de Aminoácidos , Sequência de Bases , Linhagem Celular , Ciclofilinas/química , Ciclofilinas/genética , DNA Complementar/genética , DNA Mitocondrial/genética , Biblioteca Gênica , Genes Reporter , Humanos , Dados de Sequência Molecular , Peptidilprolil Isomerase , Mapeamento por Restrição , Transfecção
7.
Cytometry ; 48(2): 106-12, 2002 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-12116372

RESUMO

BACKGROUND: Fluorescent proteins have become invaluable reporters in many areas of cellular and developmental biology. An enhanced version of the Aequorea victoria green fluorescent protein (AvEGFP) is the most widely used fluorescent protein. For a variety of reasons, it is useful to have alternative fluorescent proteins to AvEGFP. METHODS: The cDNA sequences for enhanced variants of the Anemonia cyan fluorescent protein (AmCyan1), as well as the Zoanthus green (ZsGreen1) and yellow (ZsYellow1) fluorescent proteins, were cloned downstream of a constitutive cytomegalovirus (CMV) promoter within a retroviral expression vector. NIH3T3, HEK293, SW620, and WM35 cells were transduced with recombinant retroviruses at a low multiplicity of infection (MOI) to bias for single-copy integration. Both unselected and stably selected cells transduced with the retroviral expression constructs were characterized. Expression of each fluorescent protein in cells was detected using flow cytometry and fluorescence microscopy with filter sets typically used for AvEGFP/fluorescein isothiocyanate (FITC) detection and was compared with the expression of AvEGFP. In addition, a fluorescence plate reader with several excitation and emission filter sets was used for detection. RESULTS: Expression of each protein was observable by fluorescence microscopy. Under given conditions of flow cytometry, the ZsGreen1 mean fluorescence was approximately 3-fold, 10-fold, and 50-fold greater than that of AvEGFP, ZsYellow1, and AmCyan1, respectively. AmCyan1, ZsGreen1, and AvEGFP were detected by a fluorescence plate reader. CONCLUSION: We determined that fluorescent proteins from Anthozoa species are detectable using a standard flow cytometer and fluorescence microscope. All of the mammalian cell lines tested expressed detectable levels of fluorescent proteins from stable integrated provirus. In cell lines where the AvEGFP protein is toxic or poorly expressed, these Anthozoa fluorescent proteins may serve as alternative fluorescent reporters.


Assuntos
Antozoários/fisiologia , Expressão Gênica , Indicadores e Reagentes , Proteínas Luminescentes/genética , Células 3T3 , Animais , Citometria de Fluxo/métodos , Imunofluorescência , Corantes Fluorescentes/análise , Corantes Fluorescentes/metabolismo , Vetores Genéticos , Proteínas de Fluorescência Verde , Humanos , Proteínas Luminescentes/análise , Proteínas Luminescentes/metabolismo , Melanoma , Camundongos , Microscopia de Fluorescência , Retroviridae/genética , Células Tumorais Cultivadas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...