Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anesth Analg ; 136(5): 861-876, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-37058723

RESUMO

Training and education for trauma anesthesiology have been predicated on 2 primary pathways: learning through peripheral "complex, massive transfusion cases"-an assumption that is flawed due to the unique demands, skills, and knowledge of trauma anesthesiology-or learning through experiential education, which is also incomplete due to its unpredictable and variable exposure. Residents may receive training from senior physicians who may not maintain a trauma-focused continuing medical education. Further compounding the issue is the lack of fellowship-trained clinicians and standardized curricula. The American Board of Anesthesiology (ABA) provides a section for trauma education in its Initial Certification in Anesthesiology Content Outline. However, many trauma-related topics also fall under other subspecialties, and the outline excludes "nontechnical" skills. This article focuses on the training of anesthesiology residents and proposes a tier-based approach to teaching the ABA outline by including lectures, simulation, problem-based learning discussions, and case-based discussions that are proctored in conducive environments by knowledgeable facilitators.


Assuntos
Anestesiologia , Internato e Residência , Estados Unidos , Anestesiologia/educação , Competência Clínica , Certificação , Educação de Pós-Graduação em Medicina , Currículo
2.
Transfusion ; 61(6): 1721-1728, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33846984

RESUMO

BACKGROUND: Rapid infusion of warmed blood products is the cornerstone of trauma resuscitation and treatment of surgical and obstetric massive hemorrhage. Integral to optimizing this delivery is selection of an intravenous (IV) catheter and use of a rapid infusion device (RID). We investigated which IV catheter and RID system enabled the greatest infusion rate of blood products and the governing catheter characteristics. STUDY DESIGN AND METHODS: The maximum flow rates of nine IV catheters were measured while infusing a mixture of packed red blood cells and fresh frozen plasma at a 1:1 ratio using a RID with and without a patient line extension. To account for IV catheters that achieved the RID's maximum 1000 ml/min, the conductance of each infusion circuit configuration was calculated. RESULTS: IV catheters of 7-Fr caliber or higher reached the maximum pressurized flow rate. The 9-Fr multi-lumen access catheter (MAC) achieved the greatest conductance, over sevenfold greater than the 18 g peripheral catheter (4.6 vs. 0.6 ml/min/mmHg, p < .001). Conductance was positively correlated with internal radius (ß = 1.098, 95% CI 4.286-5.025, p < .001) and negatively correlated with length (ß= - 0.495, 95% CI -0.007 to 0.005, p < .001). Use of an extension line (ß= - 0.094, 95% CI -0.505 to -0.095, p = .005) was independently associated with reduced conductance in large caliber catheters. CONCLUSION: Short, large-diameter catheters provided the greatest infusion rates of massive transfusion blood products for the least pressure. For patients requiring the highest transfusion flow rates, extension tubing should be avoided when possible.


Assuntos
Transfusão de Sangue/instrumentação , Cateterismo/instrumentação , Catéteres , Desenho de Equipamento , Transfusão de Eritrócitos/instrumentação , Humanos , Infusões Intravenosas/instrumentação
3.
Anesthesiology ; 134(1): 61-71, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33125457

RESUMO

BACKGROUND: Disease severity in coronavirus disease 2019 (COVID-19) may be associated with inoculation dose. This has triggered interest in intubation barrier devices to block droplet exposure; however, aerosol protection with these devices is not known. This study hypothesized that barrier devices reduce aerosol outside of the barrier. METHODS: Aerosol containment in closed, semiclosed, semiopen, and open barrier devices was investigated: (1) "glove box" sealed with gloves and caudal drape, (2) "drape tent" with a drape placed over a frame, (3) "slit box" with armholes and caudal end covered by vinyl slit diaphragms, (4) original "aerosol box," (5) collapsible "interlocking box," (6) "simple drape" over the patient, and (7) "no barrier." Containment was investigated by (1) vapor instillation at manikin's right arm with video-assisted visual evaluation and (2) submicrometer ammonium sulfate aerosol particles ejected through the manikin's mouth with ventilation and coughs. Samples were taken from standardized locations inside and around the barriers using a particle counter and a mass spectrometer. Aerosol evacuation from the devices was measured using standard hospital suction, a surgical smoke evacuator, and a Shop-Vac. RESULTS: Vapor experiments demonstrated leakage via arm holes and edges. Only closed and semiclosed devices and the aerosol box reduced aerosol particle counts (median [25th, 75th percentile]) at the operator's mouth compared to no barrier (combined median 29 [-11, 56], n = 5 vs. 157 [151, 166], n = 5). The other barrier devices provided less reduction in particle counts (133 [128, 137], n = 5). Aerosol evacuation to baseline required 15 min with standard suction and the Shop-Vac and 5 min with a smoke evacuator. CONCLUSIONS: Barrier devices may reduce exposure to droplets and aerosol. With meticulous tucking, the glove box and drape tent can retain aerosol during airway management. Devices that are not fully enclosed may direct aerosol toward the laryngoscopist. Aerosol evacuation reduces aerosol content inside fully enclosed devices. Barrier devices must be used in conjunction with body-worn personal protective equipment.


Assuntos
Aerossóis/análise , COVID-19/prevenção & controle , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Equipamento de Proteção Individual , Aerossóis/efeitos adversos , Tosse/prevenção & controle , Tosse/virologia , Pessoal de Saúde , Humanos , Intubação Intratraqueal/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...