Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 9(3): e90545, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24625894

RESUMO

Timely pond-side detection of white spot syndrome virus (WSSV) plays a critical role in the implementation of bio-security measures to help minimize economic losses caused by white spot syndrome disease, an important threat to shrimp aquaculture industry worldwide. A portable device, namely POCKIT™, became available recently to complete fluorescent probe-based insulated isothermal PCR (iiPCR), and automatic data detection and interpretation within one hour. Taking advantage of this platform, the IQ Plus™ WSSV Kit with POCKIT system was established to allow simple and easy WSSV detection for on-site users. The assay was first evaluated for its analytical sensitivity and specificity performance. The 95% limit of detection (LOD) of the assay was 17 copies of WSSV genomic DNA per reaction (95% confidence interval [CI], 13 to 24 copies per reaction). The established assay has detection sensitivity similar to that of OIE-registered IQ2000™ WSSV Detection and Protection System with serial dilutions of WSSV-positive Litopenaeus vannamei DNA. No cross-reaction signals were generated from infectious hypodermal and haematopoietic necrosis virus (IHHNV), monodon baculovirus (MBV), and hepatopancreatic parvovirus (HPV) positive samples. Accuracy analysis using 700 L. vannamei of known WSSV infection status shows that the established assayhassensitivity93.5% (95% CI: 90.61-95.56%) and specificity 97% (95% CI: 94.31-98.50%). Furthermore, no discrepancy was found between the two assays when 100 random L. vannamei samples were tested in parallel. Finally, excellent correlation was observed among test results of three batches of reagents with 64 samples analyzed in three different laboratories. Working in a portable device, IQ Plus™ WSSV Kit with POCKIT system allows reliable, sensitive and specific on-site detection of WSSV in L. vannamei.


Assuntos
Penaeidae/virologia , Reação em Cadeia da Polimerase/instrumentação , Viroses/diagnóstico , Viroses/veterinária , Animais , Aquicultura , DNA Viral/isolamento & purificação , Processamento Eletrônico de Dados , Limite de Detecção , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Vírus da Síndrome da Mancha Branca 1/genética
2.
J Food Prot ; 76(8): 1322-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23905786

RESUMO

Consumption of Salmonella-contaminated foods, such as poultry and fresh eggs, is known to be one of the main causes of salmonellosis. Conventional PCR methods, including real-time PCR for rapid detection of Salmonella, in general require skilled technicians and costly instruments. A recently developed novel convective PCR, insulated isothermal PCR (iiPCR), is carried out in polycarbonate capillary tubes. In this study, we designed TaqMan probes and PCR primers based on the yrfH gene encoding a heat shock protein for the iiPCR detection of Salmonella in chicken meat samples. The TaqMan probe was labeled with 6-carboxyfluorescein and 6-carboxytetramethylrhodamine at the 5' and 3' ends, respectively. The PCR amplicon was 133 bp. A typical run of this iiPCR assay was completed within 1 h. Specific PCR products were obtained for 148 strains representing 49 serotypes of Salmonella tested. Under the same conditions, false-positive results were not obtained for 98 non-Salmonella strains tested, including strains of Enterobacteriaceae closely related to Salmonella. For chicken meat samples, with a 5-h enrichment step Salmonella at as low as 10° CFU/g of poultry meat could be detected. Because the amplification signals from the probes are detectable at 520 nm, identification of the PCR products by gel electrophoresis is not required. Compared with conventional PCR, the iiPCR system requires less expertise and provides an economical, reliable, and rapid tool for result interpretation. Detection results can be obtained within 8 h, including the enrichment and DNA extraction steps.


Assuntos
Galinhas/microbiologia , DNA Bacteriano/análise , Contaminação de Alimentos/análise , Carne/microbiologia , Reação em Cadeia da Polimerase/métodos , Salmonella/isolamento & purificação , Animais , Primers do DNA , DNA Bacteriano/genética , DNA Bacteriano/metabolismo , Fluoresceínas , Reação em Cadeia da Polimerase/normas , Reprodutibilidade dos Testes , Rodaminas , Salmonella/genética , Salmonella/metabolismo , Intoxicação Alimentar por Salmonella/prevenção & controle , Sensibilidade e Especificidade , Fatores de Tempo
3.
PLoS One ; 7(9): e45278, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23049781

RESUMO

Insulated isothermal PCR (iiPCR), established on the basis of Ralyeigh-Bénard convection, is a rapid and low-cost platform for nucleic acid amplification. However, the method used for signal detection, namely gel electrophoresis, has limited the application of iiPCR. In this study, TaqMan probe-based iiPCR system was developed to obviate the need of post-amplification processing. This system includes an optical detection module, which was designed and integrated into the iiPCR device to detect fluorescent signals generated by the probe. TaqMan probe-iiPCR assays targeting white spot syndrome virus (WSSV) and infectious myonecrosis virus were developed for preliminary evaluation of this system. Significant elevation of fluorescent signals was detected consistently among positive iiPCR reactions in both assays, correlating with amplicon detection by gel electrophoresis analysis. After condition optimization, a threshold value of S/N (fluorescent intensity(after)/fluorescent intensity(before)) for positive reactions was defined for WSSV TaqMan probe-iiPCR on the basis of 20 blank reactions. WSSV TaqMan probe-iiPCR generated positive S/Ns from as low as 10(1) copies of standard DNA and lightly infected Litopenaeus vannamei. Compared with an OIE-certified nested PCR, WSSV TaqMan probe-iiPCR showed a sensitivity of 100% and a specificity of 96.67% in 120 WSSV-free or lightly infected shrimp samples. Generating positive signals specifically and sensitively, TaqMan probe-iiPCR system has a potential as a low-cost and rapid on-site diagnostics method.


Assuntos
Penaeidae/virologia , Reação em Cadeia da Polimerase/métodos , Totiviridae/genética , Totiviridae/isolamento & purificação , Vírus da Síndrome da Mancha Branca 1/genética , Vírus da Síndrome da Mancha Branca 1/isolamento & purificação , Animais , Primers do DNA/genética , Desnaturação de Ácido Nucleico , Reação em Cadeia da Polimerase/instrumentação , Sensibilidade e Especificidade , Temperatura
4.
J Virol Methods ; 181(1): 134-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22326658

RESUMO

Aiming to develop a rapid, low-cost, and user-friendly system for the diagnosis of white spot syndrome virus (WSSV), a PCR assay performed in capillary tubes under insulated isothermal conditions (iiPCR assay) was established on the basis of Rayleigh-Benard convection. WSSV amplicons were generated reproducibly within 30 min from a target sequence-containing plasmid in an iiPCR device, in which a special polycarbonate capillary tube (R-tube™) was heated isothermally by a copper ring attached to its bottom and shielded by a thermal baffle around its upper half. Furthermore, WSSV-specific amplicons were produced from nucleic acid extracts of WSSV-infected Penaeus vannamei in the WSSV iiPCR assay, with sensitivity comparable to that of an OIE-certified commercial nested PCR kit (IQ2000™ WSSV Detection and Prevention System). Specificity of the WSSV iiPCR assay was demonstrated as no amplicons were generated from shrimp genomic DNA, and IHHNV, MBV, and HPV DNA. iiPCR has a potential as a low-cost method for sensitive, specific and rapid detection of pathogens.


Assuntos
Penaeidae/virologia , Reação em Cadeia da Polimerase/métodos , Virologia/métodos , Vírus da Síndrome da Mancha Branca 1/isolamento & purificação , Animais , Tubo Capilar , Custos e Análise de Custo , Papillomaviridae , Reação em Cadeia da Polimerase/economia , Sensibilidade e Especificidade , Temperatura , Fatores de Tempo , Virologia/economia
5.
Biotechnol J ; 7(5): 662-6, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22241586

RESUMO

Rayleigh-Bénard convective PCR is a simple and effective design for amplification of DNA. Convective PCR is, however, extremely sensitive to environmental temperature fluctuations, especially when using small- diameter test tubes. Therefore, this method is inherently unstable with limited applications. Here, we present a convective PCR device that has been modified by adding thermal baffles. With this thermally baffled device the influence from fluctuations in environmental temperature were significantly reduced, even in a wind tunnel (1 m/s). The thermally baffled PCR instrument described here has the potential to be used as a low-cost, point-of-care device for PCR-based molecular diagnostics in the field.


Assuntos
Reação em Cadeia da Polimerase/instrumentação , Reação em Cadeia da Polimerase/métodos , Convecção , DNA Complementar/genética , Eletroforese em Gel de Ágar , Desenho de Equipamento , Plasmídeos/genética , Roniviridae/genética , Temperatura , Fatores de Tempo
6.
J Virol Methods ; 173(1): 67-74, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21256868

RESUMO

Aiming to establish a target amplicon-specific detection system for loop-mediated isothermal amplification (LAMP), the fluorescent resonance energy transfer (FRET) probe technology was applied to develop the FRET LAMP platform. This report describes the development of the first FRET LAMP assay targeting white spot syndrome virus (WSSV) of penaeid shrimp. A successful accelerated WSSV LAMP was assembled first in a conventional oven and confirmed by gel electrophoresis and dot-blot hybridization. Subsequently, two additional FRET probes designed to target one loop region within WSSV LAMP amplicons were added to the same LAMP reaction. The reactions were carried out in a LightCycler (Roche) and significant FRET signals were detected in real time. Optimization of the reaction using plasmid DNA shortened the time for the detection of 10(2) copies of the target DNA to less than 70min. Cross reactivity was absent with WSSV-free or infectious hypodermal and hematopoietic necrosis virus-infected Penaeus vannamei samples. The performance of this system was comparable with that of a nested PCR assay from 21 WSSV-infected shrimp. Specifically detecting target amplicons and requiring no post-amplification manipulation, the novel FRET LAMP assay should allow indisputable detection of pathogens with minimized risks of amplicon contamination.


Assuntos
Transferência Ressonante de Energia de Fluorescência , Técnicas de Amplificação de Ácido Nucleico/métodos , Sondas de Oligonucleotídeos/genética , Penaeidae/virologia , Virologia/métodos , Vírus da Síndrome da Mancha Branca 1/isolamento & purificação , Animais , Reações Cruzadas , Densovirinae/isolamento & purificação , Sondas de Oligonucleotídeos/química , Sensibilidade e Especificidade
7.
Dis Aquat Organ ; 90(1): 69-76, 2010 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-20597432

RESUMO

Abalone aquaculture is a small but growing industry in Thailand and is based on both the exotic Haliotis diversicolor supertexta and the native H. asinina. Withering syndrome (WS) in abalone is caused by an infection with the Rickettsia-like organism (RLO) 'Candidatus Xenohaliotis californiensis' and has been spread to many countries globally. The present study reports the first observation of the WS-RLO agent in the small abalone, H. diversicolor supertexta in Thailand, Taiwan (ROC) and the People's Republic of China (PRC). Under light microscopy, the RLO was observed as intracytoplasmic inclusions within epithelial cells lining the post-esophagus and, to a minor extent, the intestine of H. diversicolor. Under transmission electron microscopy, inclusions were characterized as colonies of rod-shaped bacteria, 200 x 1800 nm in size, within a vesicle in the cytoplasm of the infected cell. The RLO from the small abalone bound with WS-RLO-specific in situ hybridization probes and was amplified by polymerase chain reaction (PCR), using primers designed from the 16S rDNA sequence of the original WS-RLO from California, USA. The PCR product of RLO samples from both the PRC and Thailand showed extremely high identity with the California WS-RLO (100 and 99%, respectively). These data combined with the history of abalone movements for aquaculture purposes indicate that RLOs observed in Thailand, Taiwan and the PRC are the WS-RLO that originated from California.


Assuntos
Gastrópodes/microbiologia , Rickettsia/isolamento & purificação , Animais , Aquicultura , Sequência de Bases , DNA Bacteriano/genética , Gastrópodes/ultraestrutura , Dados de Sequência Molecular , Rickettsia/genética
8.
J Virol Methods ; 146(1-2): 317-26, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17868915

RESUMO

The goal of this study was to develop a field diagnosis system based on isothermal reverse transcription-loop-mediated amplification (RT-LAMP) for shrimp Taura syndrome virus (TSV), placing emphasis on specific and simple detection of the LAMP amplicons. After a single-tube RT-LAMP reaction for TSV was established, colorimetric dot-blot hybridization (DBH) was adopted to detect signals only from the target-derived amplicons. The results showed that the modified DBH offered unambiguous and sensitive detection of the TSV RT-LAMP amplicons without the UV cross-linking and denaturation steps. Together, TSV RT-LAMP-DBH assay reached the same dilution point as reverse transcription-nested polymerase chain reaction-agarose gel electrophoresis (RT-nPCR-AGE) for TSV detection. Specificity of the assay was demonstrated by the absence of DBH signal from yeast tRNA and various shrimp viruses. TSV RT-LAMP-DBH was applied to 125 Penaeus vannamei and demonstrated a very good concordance (kappa value, 0.823) with RT-nPCR-AGE assay in detection efficiency. Furthermore, a one-step guanidinium thiocyanate (GuSCN) homogenization method was established to provide RNA extraction efficiency comparable to that of the TRIzol Reagent for RT-LAMP. Requiring simply a heating apparatus, the GuSCN RNA extraction-isothermal RT-LAMP-DBH protocol has the potential for further development for diagnosis of diseases in the field.


Assuntos
Hibridização de Ácido Nucleico/métodos , Penaeidae/virologia , Vírus de RNA/isolamento & purificação , Reação em Cadeia da Polimerase Via Transcriptase Reversa/métodos , Animais , DNA Complementar , Técnicas de Amplificação de Ácido Nucleico , RNA Viral/isolamento & purificação , Sensibilidade e Especificidade
9.
Dis Aquat Organ ; 73(2): 103-11, 2006 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-17260829

RESUMO

Infectious hypodermal and hematopoietic necrosis virus (IHHNV) is a single-stranded DNA virus that causes developmental and growth abnormalities in Pacific white shrimp Litopenaeus vannamei (also known as Penaeus vannamei). Nucleic acid based methods such as in situ hybridization (ISH) and PCR have been commonly used for IHHNV detection. Ramification amplification (RAM), an isothermal nucleic acid amplification approach, was used in this study to detect IHHNV in L. vannamei. RAM offers many advantages over PCR, including simple procedures and short detection time, and is labor-saving and cost-effective. RAM exponentially amplifies a circular oligonucleotide amplicon (C probe) after a target-specific ligation step through sequential primer extension and strand displacement processes. The conditions of an IHHNV RAM assay were optimized using artificial templates and targets prior to application. Using DNA of IHHNV-infected L. vannamei as targets, results revealed that RAM amplified target DNA with similar sensitivity as PCR. RAM offers competitive levels of speed, simplicity and sensitivity among various pathogen diagnostic methods.


Assuntos
DNA Viral/isolamento & purificação , Densovirinae/isolamento & purificação , Técnicas de Amplificação de Ácido Nucleico/métodos , Penaeidae/virologia , Animais , DNA Viral/química , Densovirinae/genética , Oligonucleotídeos/química , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade
10.
Dis Aquat Organ ; 73(1): 13-22, 2006 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-17240748

RESUMO

Requiring only simple heating devices, isothermal nucleic acid-based amplification (NASBA) is a potential detection platform to be developed for on-site diagnosis of aquaculture pathogens. In this report, an NASBA assay has been developed for the Taura syndrome virus (TSV), one of the most devastating RNA virus pathogens for several penaeid shrimp species. The NASBA amplicons were detected by agarose gel electrophoresis and confirmed by Northern-blotting and dot-blotting analysis, using a biotinylated TSV-specific primer. The sensitivity of the TSV NASBA coupled with dot-blotting detection was approximately 5-fold less sensitive than that of the commercially available RT-nested, PCR-based IQ2000 TSV Detection and Prevention System that was also confirmed to be more sensitive than the RT-PCR-based TSV detection protocol recommended by the OIE (Office International des Epizooties). The specificity of the TSV NASBA reaction was substantiated by the results that RNA of non-target viruses did not generate any signals. Furthermore, a simple colorimetric microtiter plate assay employing TSV-specific capture and detection primers was developed as a simple alternative approach for the detection of NASBA amplicons. Taken together, the combination of the isothermal NASBA and colorimetric solid phase-based assays should allow sensitive, straightforward, and speedy on-site detection of TSV.


Assuntos
Aquicultura/métodos , Técnicas de Amplificação de Ácido Nucleico/veterinária , Penaeidae/virologia , Vírus de RNA/isolamento & purificação , Animais , Northern Blotting/veterinária , Colorimetria/veterinária , Sondas de DNA/química , Eletroforese em Gel de Ágar/veterinária , Immunoblotting/veterinária , Vírus de RNA/genética , Reação em Cadeia da Polimerase Via Transcriptase Reversa/veterinária , Sensibilidade e Especificidade , Taiwan , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA