Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Kidney Int Rep ; 8(9): 1741-1751, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37705910

RESUMO

Introduction: Vitamin K deficiency among patients on hemodialysis (HD) affects the function of matrix GLA protein (MGP), a potent vitamin K-dependent inhibitor of vascular calcification (VC). Methods: We conducted a single-center randomized controlled trial (RCT) on maintenance HD patients to examine if vitamin K2 supplementation can reduce progression of coronary artery calcification (CAC) over an 18-month study period. Patients were randomized to vitamin K2 group receiving menaquinone-7360 µg 3 times/wk or control group. The primary outcome was CAC scores at the end of the study period. The secondary outcomes were aortic valve calcification (AVC), carotid-femoral pulse wave velocity (cfPWV), aortic augmentation index (AIx), dephosphorylated undercarboxylated MGP (dp-ucMGP) levels, major adverse cardiac events (MACE), and vascular access events. Results: Of the 178 patients randomized, follow-up was completed for 138 patients. The CAC scores between the 2 groups were not statistically different at the end of 18 months (relative mean difference [RMD] 0.85, 95% CI 0.55-1.31). The secondary outcomes did not differ significantly in AVC (RMD 0.82, 95% CI 0.34-1.98), cfPWV (absolute mean difference [AMD] 0.55, 95% CI -0.50 to 1.60), and AIx (AMD 0.13, 95% CI -3.55 to 3.80). Supplementation with vitamin K2 did reduce dp-ucMGP levels (AMD -86, 95% CI -854 to -117). The composite outcome of MACE and mortality was not statistically different between the 2 groups (Hazard ratio = 0.98, 95% CI 0.50-1.94). Conclusion: Our study did not demonstrate a beneficial effect of vitamin K2 in reducing progression of VC in this population at the studied dose and duration.

2.
Drug Saf ; 46(10): 927-949, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37552439

RESUMO

Trastuzumab deruxtecan (T-DXd)-an antibody-drug conjugate targeting the human epidermal growth factor receptor 2 (HER2)-improved outcomes of patients with HER2-positive and HER2-low metastatic breast cancer. Guidance on monitoring and managing T-DXd-related adverse events (AEs) is an emerging unmet need as translating clinical trial experience into real-world practice may be difficult due to practical and cultural considerations and differences in health care infrastructure. Thus, 13 experts including oncologists, pulmonologists and a radiologist from the Asia-Pacific region gathered to provide recommendations for T-DXd-related AE monitoring and management by using the latest evidence from the DESTINY-Breast trials, our own clinical trial experience and loco-regional health care considerations. While subgroup analysis of Asian (excluding Japanese) versus overall population in the DESTINY-Breast03 uncovered no major differences in the AE profile, we concluded that proactive monitoring and management are essential in maximising the benefits with T-DXd. As interstitial lung disease (ILD)/pneumonitis is a serious AE, patients should undergo regular computed tomography scans, but the frequency may have to account for the median time of ILD/pneumonitis onset and access. Trastuzumab deruxtecan appears to be a highly emetic regimen, and prophylaxis with serotonin receptor antagonists and dexamethasone (with or without neurokinin-1 receptor antagonist) should be considered. Health care professionals should be vigilant for treatable causes of fatigue, and patients should be encouraged to use support groups and practice low-intensity exercises. To increase treatment acceptance, patients should be made aware of alopecia risk prior to starting T-DXd. Detailed monitoring and management recommendations for T-DXd-related AEs are discussed further.


Assuntos
Imunoconjugados , Doenças Pulmonares Intersticiais , Pneumonia , Humanos , Ásia
3.
Radiol Cardiothorac Imaging ; 5(6): e230064, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38166346

RESUMO

Purpose To develop a new coronary CT angiography (CCTA)-based index, α×LL/MLD4, that considers lesion entrance angle (α) in addition to lesion length (LL) and minimal lumen diameter (MLD) and to evaluate its efficacy in predicting hemodynamically significant coronary stenosis compared with invasive coronary angiography (ICA)-derived fractional flow reserve (FFR). Materials and Methods This prospective study enrolled participants (September 2016-March 2020) from two centers who underwent CCTA followed by ICA (ClinicalTrials.gov identifier: NCT03054324). CCTA images were processed semiautomatically to measure LL, MLD, and α for calculating α×LL/MLD4. Diagnostic performance and accuracy of α×LL/MLD4 and LL/MLD4 in detecting hemodynamically significant coronary stenosis were compared against the reference standard (invasive FFR ≤ 0.80). Results In total, 133 participants (mean age, 63 years ± 9 [SD]; 99 [74%] men) with 210 stenosed coronary arteries were analyzed. Median α×LL/MLD4 was 54.0 degree/mm3 (IQR, 25.3-128.7) in participants with invasive FFR of 0.80 or less and 6.7 degree/mm3 (IQR, 3.3-12.8) in participants with invasive FFR of more than 0.80 (P < .001). The per-vessel accuracy, sensitivity, specificity, positive predictive value, and negative predictive value for discriminating ischemic lesions were 86.2%, 83.1%, 88.4%, 84.1%, and 87.7% for α×LL/MLD4 and 80.5%, 66.3%, 90.9%, 84.3%, and 78.6% for LL/MLD4, respectively. Area under the receiver operating characteristic curve for discriminating hemodynamically significant stenosis was 0.93 for α×LL/MLD4, which was significantly greater than the values of 0.84 for LL/MLD4 and 0.63 for diameter stenosis (both P < .001). Conclusion The new morphologic index, α×LL/MLD4, incorporating lesion entrance angle achieved higher diagnostic performance in detecting hemodynamically significant lesions compared with diameter stenosis and LL/MLD4. Keywords: CT Angiography, Cardiac, Coronary Arteries, Ischemia, Infarction, Technology Assessment Clinical trial registration no. NCT03054324 Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Fairbairn and Nørgaard in this issue.


Assuntos
Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Constrição Patológica , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico , Estudos Prospectivos , Estudos Retrospectivos , Idoso
4.
Singapore Med J ; 2021 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-34688230

RESUMO

INTRODUCTION: Computed tomography angiography of the aorta (CTAA) is the modality of choice for investigating aortic disease. Our aim was to evaluate image quality, contrast enhancement and radiation dose of electrocardiograph (ECG)-triggered and non-ECG-triggered CTAA on a 256-slice single source CT scanner. Knowledge of these will allow requesting clinician and radiologist to balance radiation risk and image quality. METHODS: We retrospectively assessed data from 126 patients who had undergone CTAA on a single-source CT scanner using ECG-triggered (group 1, n = 77) or non-ECG-triggered (group 2, n =49) protocols. Radiation doses were compared. Qualitative (4-point scale) and quantitative image quality assessments were performed. RESULTS: The mean volume CT dose index, dose length product and effective dose in group 1 were 12.4 ± 1.9 mGy, 765.8 ± 112.4 mGy x cm and 13.0 ± 1.9 mSv, respectively. These were significantly higher compared with group 2 (9.1 ± 2.6 mGy, 624.1 ± 174.8 mGy x cm and 10.6 ± 3.0 mSv, respectively) ( p < 0.001). Qualitative assessment showed image quality at the aortic root-proximal ascending aorta was significantly higher in group 1 (median = 3) than in group 2 (median = 2, p < 0.001). Quantitative assessment showed significantly better mean arterial attenuation, signal-to-noise ratio and contrast-to-noise ratio in ECG-triggered CTAA compared with non-ECG-triggered CTAA. CONCLUSION: ECG-triggered CTAA in a single-source scanner has superior image quality and vessel attenuation of aortic root/ascending aorta but a higher radiation dose of approximately 23%. Its use should be considered specifically when assessing aortic root/ascending aorta pathology.

5.
Singapore Med J ; 61(3): 109-115, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32488269

RESUMO

Computed tomography coronary angiography (CTCA) is a robust and reliable non-invasive alternative imaging modality to invasive coronary angiography, which is the reference standard in evaluating the degree of coronary artery stenosis. CTCA has high negative predictive value and can confidently exclude significant coronary artery disease (CAD) in low to intermediate risk patients. Over the years, substantial effort has been made to reduce the radiation dose and increase the cost efficiency of CTCA. In this review, we present the evolution of computed tomography scanners in the context of coronary artery imaging as well as its clinical applications and limitations. We also highlight the future directions of CTCA as a one-stop non-invasive imaging modality for anatomic and functional assessment of CAD.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Angiografia Coronária/tendências , Doença da Artéria Coronariana/cirurgia , Humanos , Stents , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/tendências
7.
Singapore Med J ; 60(11): 554-559, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31781779

RESUMO

Lung cancer is the leading cause of cancer-related death around the world, being the top cause of cancer-related deaths among men and the second most common cause of cancer-related deaths among women in Singapore. Currently, no screening programme for lung cancer exists in Singapore. Since there is mounting evidence indicating a different epidemiology of lung cancer in Asian countries, including Singapore, compared to the rest of the world, a unique and adaptive approach must be taken for a screening programme to be successful at reducing mortality while maintaining cost-effectiveness and a favourable risk-benefit ratio. This review article promotes the use of low-dose computed tomography of the chest and explores the radiological challenges and future directions.


Assuntos
Detecção Precoce de Câncer/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Programas de Rastreamento/métodos , Radiologia/organização & administração , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Ensaios Clínicos como Assunto , Análise Custo-Benefício , Aprendizado Profundo , Diagnóstico por Computador , Europa (Continente) , Reações Falso-Positivas , Humanos , Comunicação Interdisciplinar , Guias de Prática Clínica como Assunto , Saúde Pública , Doses de Radiação , Sistema de Registros , Medição de Risco , Singapura/epidemiologia , Abandono do Hábito de Fumar , Estados Unidos
11.
Pediatr Cardiol ; 37(8): 1397-1403, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27377528

RESUMO

The aim of this study was to investigate whether there is a reduction in radiation dose and improvement in image quality of pediatric cardiac computed tomography scans performed using the high-pitch spiral technique on a new third-generation dual-source 2 × 192-slice scanner (group B) compared with scans performed using the sequential technique on a single-source 256-slice scanner (group A). We performed a retrospective observational study on 40 patients aged ≤18 years who underwent prospectively electrocardiogram-triggered cardiac computed tomography. Image quality was assessed by pre-defined objective indices and a four-point subjective score. Apart from a higher mean heart rate in group A (P = 0.016), there were otherwise no significant inter-group differences in patient characteristics. The median effective dose was 4.41 mSv (interquartile range 2.58-5.90 mSv) in group A and 0.52 mSv (interquartile range 0.39-0.59 mSv) in group B (P < 0.001), representing a 88 % reduction. Subjective image quality score was significantly better in group B (4 = excellent with no artifact, mode 57.1 %) than in group A (3 = good with mild artifact, mode 57.9 %) (P < 0.001). Noise index, signal-to-noise ratio and contrast-to-noise ratio between both groups were not statistically significant. New third-generation dual-source high-pitch spiral scan technique can deliver excellent image quality with low radiation dose. Our results suggest that it should be considered as a first-choice technique for performing cardiac computed tomography in the pediatric population.


Assuntos
Cardiopatias/diagnóstico por imagem , Criança , Angiografia Coronária , Eletrocardiografia , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada Espiral , Tomografia Computadorizada por Raios X
13.
Eur Radiol ; 26(2): 398-406, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26032879

RESUMO

OBJECTIVES: Comparison of magnetic resonance elastography (MRE) and diffusion-weighted imaging (DWI) for differentiating malignant and benign focal liver lesions (FLLs). METHODS: Seventy-nine subjects with 124 FLLs (44 benign and 80 malignant) underwent both MRE and DWI. MRE was performed with a modified gradient-echo sequence and DWI with a free breathing technique (b = 0.500). Apparent diffusion coefficient (ADC) maps and stiffness maps were generated. FLL mean stiffness and ADC values were obtained by placing regions of interest over the FLLs on stiffness and ADC maps. The accuracy of MRE and DWI for differentiation of benign and malignant FLL was compared using receiver operating curve (ROC) analysis. RESULTS: There was a significant negative correlation between stiffness and ADC (r = -0.54, p < 0.0001) of FLLs. Malignant FLLs had significantly higher mean stiffness (7.9kPa vs. 3.1kPa, p < 0.001) and lower mean ADC (129 vs. 200 × 10(-3)mm(2)/s, p < 0.001) than benign FLLs. The sensitivity/specificity/positive predictive value/negative predictive value for differentiating malignant from benign FLLs with MRE (cut-off, >4.54kPa) and DWI (cut-off, <151 × 10(-3)mm(2)/s) were 96.3/95.5/97.5/93.3% (p < 0.001) and 85/81.8/88.3/75% (p < 0.001), respectively. ROC analysis showed significantly higher accuracy for MRE than DWI (0.986 vs. 0.82, p = 0.0016). CONCLUSION: MRE is significantly more accurate than DWI for differentiating benign and malignant FLLs. KEY POINTS: • MRE is superior to DWI for differentiating benign and malignant focal liver lesions. • Benign lesions with large fibrous components may have higher stiffness with MRE. • Cholangiocarcinomas tend to have higher stiffness than hepatocellular carcinomas. • Hepatocellular adenomas tend to have lower stiffness than focal nodular hyperplasia. • MRE is superior to conventional MRI in differentiating benign and malignant liver lesions.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Adulto , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Fígado/patologia , Masculino , Curva ROC , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
14.
Singapore Med J ; 56(4): 198-201; quiz 202, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25917470

RESUMO

Levocardia (left-sided cardiac apex) with abdominal situs inversus is extremely rare. This is also known as isolated levocardia and is almost always associated with severe forms of congenital heart defects with poor prognosis. We report isolated levocardia in a 13-year-old symptomatic male patient. The purpose of this paper is to outline the imaging features of isolated levocardia and to highlight the role of cardiovascular magnetic resonance imaging (CMR) in the diagnosis and management of such cases. Other forms of cardiac malposition, including dextrocardia, mesocardia and criss-cross heart, with chest radiograph and CMR correlation, are also discussed.


Assuntos
Anormalidades Múltiplas/diagnóstico , Diagnóstico por Imagem , Levocardia/diagnóstico , Situs Inversus/diagnóstico , Adolescente , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Radiografia Torácica , Tomografia Computadorizada por Raios X
15.
Singapore Med J ; 55(9): 462-6; quiz 467, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273929

RESUMO

We report the case of a 70-year-old man with an asymptomatic large patent ductus arteriosus (PDA) incidentally detected on triple-rule-out computed tomography (CT). CT clearly demonstrated a vascular structure connecting the descending thoracic aorta to the roof of the proximal left pulmonary artery, consistent with a PDA. Secondary pulmonary arterial hypertension was also evident on CT. The patient was eventually diagnosed with acute coronary syndrome and was successfully treated with coronary artery bypass graft surgery and concomitant patch closure of the PDA. This article aims to outline the imaging features of PDA and highlight the information provided by CT, which is crucial to treatment planning. The pathophysiology, clinical manifestations and closure options of PDA are also briefly discussed.


Assuntos
Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Aorta Torácica/diagnóstico por imagem , Ecocardiografia , Cardiopatias/congênito , Cardiopatias/diagnóstico por imagem , Humanos , Lactente , Masculino , Obesidade/complicações , Artéria Pulmonar/patologia , Radiografia Torácica , Resultado do Tratamento , Adulto Jovem
16.
Singapore Med J ; 53(8): e176-8, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22941148

RESUMO

Double outlet right ventricle (DORV) is an uncommon congenital heart disease with a poor prognosis. We report a rare case of a girl with untreated DORV who survived until adolescence, but then developed infective endocarditis with florid complications and succumbed to it. Although infective endocarditis is seldom encountered in children in developed countries, a high index of suspicion is required for those with congenital heart disease. The roles of cross-sectional imaging are demonstrated, including the usefulness of magnetic resonance imaging not only in evaluating congenital heart disease, but also in detecting incidental lesions in the extracardiac structures.


Assuntos
Dupla Via de Saída do Ventrículo Direito/complicações , Endocardite/etiologia , Adolescente , Endocardite/diagnóstico , Evolução Fatal , Feminino , Humanos
17.
J Digit Imaging ; 24(4): 598-608, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20623156

RESUMO

Segmentation of the left ventricle is important in the assessment of cardiac functional parameters. Manual segmentation of cardiac cine MR images for acquiring these parameters is time-consuming. Accuracy and automation are the two important criteria in improving cardiac image segmentation methods. In this paper, we present a comprehensive approach to segment the left ventricle from short axis cine cardiac MR images automatically. Our method incorporates a number of image processing and analysis techniques including thresholding, edge detection, mathematical morphology, and image filtering to build an efficient process flow. This process flow makes use of various features in cardiac MR images to achieve high accurate segmentation results. Our method was tested on 45 clinical short axis cine cardiac images and the results are compared with manual delineated ground truth (average perpendicular distance of contours near 2 mm and mean myocardium mass overlapping over 90%). This approach provides cardiac radiologists a practical method for an accurate segmentation of the left ventricle.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Disfunção Ventricular Esquerda/diagnóstico , Algoritmos , Humanos , Aumento da Imagem/métodos , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...