Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Breast Imaging ; 6(2): 149-156, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38423093

RESUMO

OBJECTIVE: Complex cystic and solid breast mass (CCSBM) is a radiological diagnosis based on grayscale B-mode sonographic features. Because of potential for malignancy, biopsy is typically recommended. We examined the feasibility of contrast-enhanced US (CEUS) as a tool to identify benign CCSBMs. METHODS: This Institutional Review Board-approved prospective observational study performed targeted CEUS of 14 CCSBMs that were subsequently biopsied. CEUS images were independently reviewed by two readers blinded to other sonographic features, noting presence or absence of enhancement and time to perceived optimal enhancement. Interobserver agreement for presence or absence of enhancement was analyzed using Cohen's kappa coefficient. From retrospective review of initial diagnostic US examinations, descriptive CCSBM sizes, subtypes, and Doppler information were recorded. Histopathologies were categorized as benign, benign with upgrade potential (BWUP), and malignant. Measures of diagnostic accuracy and 95% CIs were calculated for CEUS enhancement. RESULTS: Of 14 CCSBMs, 12 were nonmalignant (9 benign, 3 BWUP) and 2 were malignant. There was perfect interobserver agreement (Cohen's kappa 1.00) between the 2 readers for CEUS enhancement. CEUS was 100% sensitive, 25% specific, with an area under the receiver operating characteristic curve (AUROC) of 0.625 (95% CI, 0.50-0.75) in differentiating nonmalignant from malignant lesions. It was 100% sensitive, 33.3% specific, with an AUROC of 0.667 (95% CI, 0.50-0.85) in differentiating benign from surgically significant (BWUP and malignant) CCSBMs. CONCLUSION: This small feasibility study highlighted the potential of CEUS as a safe noninvasive tool to identify the proportion of CCSBMs that are benign and can avoid tissue biopsy.


Assuntos
Meios de Contraste , Neoplasias Renais , Feminino , Humanos , Estudos de Viabilidade , Mama/patologia , Ultrassonografia/métodos , Neoplasias Renais/patologia
3.
Thromb J ; 21(1): 110, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37885036

RESUMO

Current clinical practice guidelines lack explicit guidance on the indications and appropriate timing of venous ultrasound (US) in lower extremity deep vein thrombosis (DVT) follow-up. Moreover, abnormal findings reported on venous US in DVT follow-up or suspected recurrent DVT may be difficult for clinicians to interpret, which carries risk of harm from inappropriate use of anti- coagulation and increased healthcare resource utilization. Due to the above factors, over-use of ultrasound in diagnosis and follow-up of lower extremity DVT has been reported in western health systems. We have undertaken a case-based discussion and a scoping review of existing guidelines on the use of venousUS following prior diagnosis of DVT, to guide appropriate interpretation of commonly reported US abnormalities and provide our suggestions in the light of best available evidence on appropriate timing to perform follow-up US in management of lower extremity DVT.

5.
Pharmaceutics ; 15(1)2022 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-36678734

RESUMO

Promising results in clinical studies have been demonstrated by the utilization of electrothermal agents (ETAs) in cancer therapy. However, a difficulty arises from the balance between facilitating the degradation of ETAs, and at the same time, increasing the electrothermal performance/stability required for highly efficient treatment. In this study, we controlled the thermal signature of the MoS2 by harnessing MoS2 nanostructures with M13 phage (MNM) via the structural assembling (hydrophobic interaction) phenomena and developed a combined PANC-1 cancer cell-MNM alternating current (AC)-stimulus framework for cancer cell ablation and electrothermal therapy. A percentage decrease in the cell viability of ~23% was achieved, as well as a degradation time of 2 weeks; a stimulus length of 100 µs was also achieved. Molecular dynamics (MD) simulations revealed the assembling kinetics in integrated M13 phage-cancer cell protein systems and the structural origin of the hydrophobic interaction-enabled increase in thermal conduction. This study not only introduced an 'ideal' agent that avoided the limitations of ETAs but also provided a proof-of-concept application of MoS2-based materials in efficacious cancer therapy.

6.
Clin Imaging ; 62: 63-68, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32070868

RESUMO

PURPOSE: To study the comparative performance of contrast-enhanced ultrasound (CEUS) and contrast-enhanced CT or MRI (CECT/MR) in evaluating liver lesions using the LI-RADS guidelines. METHODS: Retrospective analysis of radiology database from July 2010 to April 2017 revealed 228 patients who had CECT/MR and CEUS. Patients at risk of hepatocellular carcinoma (HCC), had contemporaneous CEUS and CECT/CEMR studies within 3 months and adequate follow up were included; reviewed (2 reviewers) and graded according to the 2017 CEUS and 2018 CECT/MR LI-RADS guidelines. Reference standard was multidisciplinary clinical decisions, histology or follow-up imaging. RESULTS: The study cohort consisted of 45 patients with 46 lesions. HCC were significantly larger than non-malignant (mean sizes of 2.5 and 1.4 cm, respectively, p<0.001). Intraclass correlation coefficient for CEUS review (0.941) was higher than of CECT/MR review (0.643). Mean area-under-ROC curve (AUC) for CEUS (0.994) was significantly higher than of CECT/MR (0.760) for all lesions (p=0.01). For lesions scored LR-3 by CECT/MR, the AUC was significantly higher for CEUS (0.978) than CECT/MR (0.500) (p<0.001). Twenty-one (of 27) lesions, classified LR-3 or LR-4 by CECT/MR were upgraded by CEUS and 20 were found to be HCC. Six lesions that were LR-3 on both CECT/MR and CEUS were found to be non-malignant. There was good concordance for LR-5 lesions between both techniques. CONCLUSION: CEUS is useful for reassessment of lesions with intermediate probability (LR-3) or probable for HCC (LR-4) on CECT/MR. Lesions upgraded by CEUS tend to be HCC. Lesions that remain LR-3 on CEUS tend to be non-malignant.


Assuntos
Ultrassonografia/métodos , Adulto , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Estudos de Coortes , Meios de Contraste , Feminino , Humanos , Neoplasias Hepáticas/induzido quimicamente , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
7.
Ann Acad Med Singap ; 47(8): 278-284, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30242297

RESUMO

INTRODUCTION: In this study, we aimed to compare the split-bolus and single-bolus computerised tomography (CT) urography and determine if this offers a reduction in radiation dose without compromising image quality. MATERIALS AND METHODS: A retrospective evaluation was performed on 88 patients undergoing split-bolus CT urography and this was compared to a control group of 101 consecutive patients undergoing single-bolus CT urography. A radiation dose analysis was performed on each subject. Subjects with urinary bladder lesions, hydronephrosis, renal masses or cysts >3 cm in diameter were excluded. All images were classified according to image quality by 2 consultant radiologists. RESULTS: Opacification of  the renal parenchyma, pelvicalyceal system, proximal ureters and urinary bladder were comparable between the 2 techniques, whilst image quality of the middle and distal third of the ureters was better using the split-bolus technique. The mean dose length product (DLP) for the single-bolus technique was 1324.1 mGy-cm, whilst that of  the split-bolus technique was 885.7 mGy-cm. The mean effective dose reduction was calculated to be 31.1% between the 2 groups. CONCLUSION: The split-bolus technique gives a reduced radiation dose without compromising image quality. The associated reduction in images is beneficial for data storage and reporting efficiency. As such, our department will adopt the split-bolus technique for young, low-risk patients.


Assuntos
Aumento da Imagem , Tomografia Computadorizada por Raios X/métodos , Urografia , Administração Intravenosa , Humanos , Interpretação de Imagem Assistida por Computador , Estudos Retrospectivos
8.
J Clin Ultrasound ; 46(6): 424-429, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29105814

RESUMO

We report in the case of a patient with an intra-abdominal aortic aneurysm treated with endovascular aneurysm repair (EVAR) who developed renal impairment during the period of follow up. The repair was complicated with an early-onset type II endoleak which later evolved into a late-onset type I endoleak. It was treated with proximal extension of stent graft, with treatment success and follow-up documented on contrast enhanced ultrasound (CEUS). This case illustrates the usefulness of CEUS in post-EVAR surveillance and emphasizes the need for life-long monitoring as late-onset complications are not uncommon.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Meios de Contraste , Endoleak/diagnóstico por imagem , Procedimentos Endovasculares/métodos , Aumento da Imagem/métodos , Ultrassonografia/métodos , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Endoleak/cirurgia , Humanos , Masculino , Fosfolipídeos , Reoperação , Hexafluoreto de Enxofre
9.
Adv Exp Med Biol ; 818: 231-54, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25001540

RESUMO

Gene therapy delivery using viral vectors has demonstrated efficient transfection but has safety issues. The need for safer yet effective delivery systems has led to the active development of non-viral techniques. In this chapter, we will discuss two evolving techniques - sonoporation with microbubble contrast agents and electroporation with focus on their basic principle, parameters affecting delivery efficiency, current evolving techniques and future prospects.


Assuntos
Eletroquimioterapia/métodos , Vetores Genéticos , Transfecção/métodos , Ultrassonografia/métodos , Animais , Eletroquimioterapia/instrumentação , Humanos , Transfecção/instrumentação , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...