Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 24(Pt 6): 1137-1145, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091056

RESUMO

In this work a double-crystal setup is employed to study compound refractive lenses made of single-crystal diamond. The point spread function of the lens is calculated taking into account the lens transmission, the wavefront aberrations, and the ultra-small-angle broadening of the X-ray beam. It is shown that, similarly to the wavefront aberrations, the ultra-small-angle scattering effects can significantly reduce the intensity gain and increase the focal spot size. The suggested approach can be particularly useful for the characterization of refractive X-ray lenses composed of many tens of unit lenses.

2.
J Synchrotron Radiat ; 22(3): 626-33, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931078

RESUMO

Multiplexing of the Linac Coherent Light Source beam was demonstrated for hard X-rays by spectral division using a near-perfect diamond thin-crystal monochromator operating in the Bragg geometry. The wavefront and coherence properties of both the reflected and transmitted beams were well preserved, thus allowing simultaneous measurements at two separate instruments. In this report, the structure determination of a prototypical protein was performed using serial femtosecond crystallography simultaneously with a femtosecond time-resolved XANES studies of photoexcited spin transition dynamics in an iron spin-crossover system. The results of both experiments using the multiplexed beams are similar to those obtained separately, using a dedicated beam, with no significant differences in quality.

3.
J Appl Crystallogr ; 47(Pt 4): 1329-1336, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25242912

RESUMO

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ∼100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

4.
Opt Express ; 21(25): 30932-46, 2013 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-24514666

RESUMO

We report on the design, implementation, and performance of an x-ray monochromator with ultra-high energy resolution (ΔE/E ≃ 2.7 × 10(-8)) and high spectral efficiency using x rays with photon energies E ≃ 9.13 keV. The operating principle of the monochromator is based on the phenomenon of angular dispersion in Bragg back-diffraction. The optical scheme of the monochromator is a modification of a scheme reported earlier [Shvyd'ko et al., Phys. Rev. A 84, 053823 (2011)], where a collimator/wavelength selector Si crystal was replaced with a 100-µm-thick type IIa diamond crystal. This modification provides a very-small-energy bandwidth ΔE ≃ 0.25 meV, a 3-fold increase in the aperture of the accepted beam, a reduction in the cumulative angular dispersion rate of x rays emanating from the monochromator for better focusing on a sample, a sufficient angular acceptance matching the angular divergence of an undulator source (≈ 10 µrad), and an improved throughput due to low x-ray absorption in the thin diamond crystal. The measured spectral efficiency of the monochromator was ≈ 65% with an aperture of 0.3 × 1 mm(2). The performance parameters of the monochromator are suitable for inelastic x-ray spectroscopy with an absolute energy resolution ΔE < 1 meV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...