1.
J Appl Crystallogr ; 47(Pt 4): 1329-1336, 2014 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-25242912

RESUMO

A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal, with a thickness of ∼100 µm, provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. This article reports the design, fabrication and X-ray characterization of the first and second (300 µm-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 × 2 mm with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 × 2 mm working regions of the crystals.

2.
Opt Express ; 21(25): 30932-46, 2013 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-24514666

RESUMO

We report on the design, implementation, and performance of an x-ray monochromator with ultra-high energy resolution (ΔE/E ≃ 2.7 × 10(-8)) and high spectral efficiency using x rays with photon energies E ≃ 9.13 keV. The operating principle of the monochromator is based on the phenomenon of angular dispersion in Bragg back-diffraction. The optical scheme of the monochromator is a modification of a scheme reported earlier [Shvyd'ko et al., Phys. Rev. A 84, 053823 (2011)], where a collimator/wavelength selector Si crystal was replaced with a 100-µm-thick type IIa diamond crystal. This modification provides a very-small-energy bandwidth ΔE ≃ 0.25 meV, a 3-fold increase in the aperture of the accepted beam, a reduction in the cumulative angular dispersion rate of x rays emanating from the monochromator for better focusing on a sample, a sufficient angular acceptance matching the angular divergence of an undulator source (≈ 10 µrad), and an improved throughput due to low x-ray absorption in the thin diamond crystal. The measured spectral efficiency of the monochromator was ≈ 65% with an aperture of 0.3 × 1 mm(2). The performance parameters of the monochromator are suitable for inelastic x-ray spectroscopy with an absolute energy resolution ΔE < 1 meV.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...