Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 179
Filtrar
1.
Clin Rheumatol ; 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684600

RESUMO

OBJECTIVE: To assess whether using ultrasound (US) in addition to clinical information versus only clinical information in a treat-to-target (T2T) strategy leads to more clinical remission and to less radiographic progression in RA. METHODS: Patients with RA from the 2-year prospective BIODAM cohort were included. Clinical and US data (US7-score) were collected every 3 months and hands and feet radiographs every 6 months. At each visit, it was decided whether patients were treated according to the clinical definition of T2T with DAS44 remission as benchmark (T2T-DAS44). T2T-DAS44 was correctly applied if: (i) DAS44 remission had been achieved or (ii) if not, treatment was intensified. A T2T strategy also considering US data (T2T-DAS44-US) was correctly applied if: (i) both DAS44 and US remission (synovitis-score < 2, Doppler-score = 0) were present; or (ii) if not, treatment was intensified. The effect of T2T-DAS44-US on attaining clinical remission and on change in Sharp-van der Heijde score compared to T2T-DAS44 was analysed. RESULTS: A total of 1016 visits of 128 patients were included. T2T-DAS44 was correctly followed in 24% of visits and T2T-DAS44-US in 41%. DAS44 < 1.6 was achieved in 39% of visits. Compared to T2T-DAS44, using the T2T-DAS44-US strategy resulted in a 41% lower likelihood of DAS44 remission [OR (95% CI): 0.59 (0.40;0.87)] and had no effect on radiographic progression [ß(95% CI): 0.11 (- 0.16;0.39)] assessed at various intervals up to 12 months later. CONCLUSION: Our results do not suggest a benefit of using the US7-score in addition to clinical information as a T2T benchmark compared to clinical information alone. Key Points • Ultrasound has a valuable role in diagnostic evaluation of rheumatoid arthritis, but it is unclear whether adding ultrasound to the clinical assessment in a treat-to-target (T2T) strategy leads to more patients achieving remission and reduction in radiographic progression. • Our data from a real-world study demonstrated that adding information from ultrasound to the clinical assessment in a T2T strategy led to a lower rather than a higher likelihood of obtaining clinical remission as compared to using only clinical assessment. • Our data demonstrated that adding ultrasound data to a T2T strategy based only on clinical assessment did not offer additional protection against radiographic progression in patients with RA. • Adding US to a T2T strategy based on clinical assessment led to far more treatment intensifications (with consequences for costs and exposure to adverse events) without yielding a meaningful clinical benefit.

2.
Front Med (Lausanne) ; 11: 1297088, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38500949

RESUMO

Objective: To develop an artificial intelligence (AI) model able to perform both segmentation of hand joint ultrasound images for osteophytes, bone, and synovium and perform osteophyte severity scoring following the EULAR-OMERACT grading system (EOGS) for hand osteoarthritis (OA). Methods: One hundred sixty patients with pain or reduced function of the hands were included. Ultrasound images of the metacarpophalangeal (MCP), proximal interphalangeal (PIP), distal interphalangeal (DIP), and first carpometacarpal (CMC1) joints were then manually segmented for bone, synovium and osteophytes and scored from 0 to 3 according to the EOGS for OA. Data was divided into a training, validation, and test set. The AI model was trained on the training data to perform bone, synovium, and osteophyte identification on the images. Based on the manually performed image segmentation, an AI was trained to classify the severity of osteophytes according to EOGS from 0 to 3. Percent Exact Agreement (PEA) and Percent Close Agreement (PCA) were assessed on individual joints and overall. PCA allows a difference of one EOGS grade between doctor assessment and AI. Results: A total of 4615 ultrasound images were used for AI development and testing. The developed AI model scored on the test set for the MCP joints a PEA of 76% and PCA of 97%; for PIP, a PEA of 70% and PCA of 97%; for DIP, a PEA of 59% and PCA of 94%, and CMC a PEA of 50% and PCA of 82%. Combining all joints, we found a PEA between AI and doctor assessments of 68% and a PCA of 95%. Conclusion: The developed AI model can perform joint ultrasound image segmentation and severity scoring of osteophytes, according to the EOGS. As proof of concept, this first version of the AI model is successful, as the agreement performance is slightly higher than previously found agreements between experts when assessing osteophytes on hand OA ultrasound images. The segmentation of the image makes the AI explainable to the doctor, who can immediately see why the AI applies a given score. Future validation in hand OA cohorts is necessary though.

3.
Ann Rheum Dis ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38531611

RESUMO

OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.

4.
Front Med (Lausanne) ; 11: 1309905, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38449885

RESUMO

Introduction: The need to systematically examine patients suspected of polymyalgia rheumatica (PMR) and giant cell arteritis (GCA) for malignancy is controversial. The aim of this study was to assess the frequency of malignancy in patients with suspected PMR and/or GCA who have been referred to a 2-deoxy-2-[18F]fluoro-D-glucose positron emission tomography with computed tomography (FDG-PET/CT) as part of the diagnostic investigation. Method: The records of all patients referred to FDG-PET/CT from Center for Rheumatology and Spine Diseases, Rigshospitalet, Glostrup with the suspicion of PMR and/or GCA during a two-year period, were retrospectively reviewed. Data was analyzed with descriptive statistics, and a standard incidence ratio was calculated based on background cancer incidences extracted from the NORDCAN database. Results: 220 patients were included in the study. Findings suspicious of malignancy were found in 19 of the examinations, and in seven cases (3.2%), malignancy was confirmed. In three out of the seven cases the patients were diagnosed with PMR concomitantly with malignancy. The estimated standardized incidence ratio (SIR) for cancer compared to the background incidence of cancer in Denmark was 1.58 (95% CI 0.63-2.97), i.e., not statistically significant. There were no statistically significant differences in characteristics of the patients that were diagnosed with malignancy compared with those that were not. Conclusion: The frequency of malignancy in this cohort of patients with suspected PMR/GCA who underwent PET/CT was low. Our results, though based on a small cohort, do not suggest that all patients with suspected PMR/GCA should systematically be examined with FDG-PET/CT for excluding malignancy.

5.
Semin Arthritis Rheum ; 65: 152378, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310657

RESUMO

Sjögren's disease (SjD) is a systemic autoimmune exocrinopathy with key features of dryness, pain, and fatigue. SjD can affect any organ system with a variety of presentations across individuals. This heterogeneity is one of the major barriers for developing effective disease modifying treatments. Defining core disease domains comprising both specific clinical features and incorporating the patient experience is a critical first step to define this complex disease. The OMERACT SjD Working Group held its first international collaborative hybrid meeting in 2023, applying the OMERACT 2.2 filter toward identification of core domains. We accomplished our first goal, a scoping literature review that was presented at the Special Interest Group held in May 2023. Building on the domains identified in the scoping review, we uniquely deployed multidisciplinary experts as part of our collaborative team to generate a provisional domain list that captures SjD heterogeneity.


Assuntos
Síndrome de Sjogren , Humanos , Resultado do Tratamento , Síndrome de Sjogren/terapia , Dor , Fadiga
6.
Nat Struct Mol Biol ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321148

RESUMO

Despite the importance of citrullination in physiology and disease, global identification of citrullinated proteins, and the precise targeted sites, has remained challenging. Here we employed quantitative-mass-spectrometry-based proteomics to generate a comprehensive atlas of citrullination sites within the HL60 leukemia cell line following differentiation into neutrophil-like cells. We identified 14,056 citrullination sites within 4,008 proteins and quantified their regulation upon inhibition of the citrullinating enzyme PADI4. With this resource, we provide quantitative and site-specific information on thousands of PADI4 substrates, including signature histone marks and transcriptional regulators. Additionally, using peptide microarrays, we demonstrate the potential clinical relevance of certain identified sites, through distinct reactivities of antibodies contained in synovial fluid from anti-CCP-positive and anti-CCP-negative people with rheumatoid arthritis. Collectively, we describe the human citrullinome at a systems-wide level, provide a resource for understanding citrullination at the mechanistic level and link the identified targeted sites to rheumatoid arthritis.

7.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401294

RESUMO

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Assuntos
Gota , Doenças Pulmonares Intersticiais , Doenças Musculares , Humanos , Reprodutibilidade dos Testes , Ultrassonografia/métodos , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Padrões de Referência
8.
Ann Rheum Dis ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38320811

RESUMO

OBJECTIVE: To formulate evidence-based recommendations and overarching principles on the use of imaging in the clinical management of crystal-induced arthropathies (CiAs). METHODS: An international task force of 25 rheumatologists, radiologists, methodologists, healthcare professionals and patient research partners from 11 countries was formed according to the EULAR standard operating procedures. Fourteen key questions on the role of imaging in the most common forms of CiA were generated. The CiA assessed included gout, calcium pyrophosphate deposition disease and basic calcium phosphate deposition disease. Imaging modalities included conventional radiography, ultrasound, CT and MRI. Experts applied research evidence obtained from four systematic literature reviews using MEDLINE, EMBASE and CENTRAL. Task force members provided level of agreement (LoA) anonymously by using a Numerical Rating Scale from 0 to 10. RESULTS: Five overarching principles and 10 recommendations were developed encompassing the role of imaging in various aspects of patient management: making a diagnosis of CiA, monitoring inflammation and damage, predicting outcome, response to treatment, guided interventions and patient education. Overall, the LoA for the recommendations was high (8.46-9.92). CONCLUSIONS: These are the first recommendations that encompass the major forms of CiA and guide the use of common imaging modalities in this disease group in clinical practice.

9.
J Crohns Colitis ; 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38366120

RESUMO

OBJECTIVES: Musculoskeletal manifestations in patients with inflammatory bowel disease (IBD) are common and associated with poorer outcomes. Hence, early detection is important to optimally tailor treatment. We aimed to determine the prevalence and distribution of inflammatory lesions in peripheral joints and entheses in newly diagnosed IBD patients. DESIGN: Patients with newly diagnosed IBD from a prospective population-based inception cohort were consecutively included. Data on musculoskeletal symptoms were collected by questionnaires and by structured rheumatological interview. Peripheral joints and entheses were assessed clinically and by ultrasound (US), using standardized definitions. RESULTS: Of 110 included patients (mean age: 42 years, 40% male, 70 with ulcerative colitis (UC), 40 with Crohn's disease (CD)), history of ≥1 musculoskeletal symptoms was reported by 49%. Clinical examination revealed peripheral musculoskeletal manifestations in 56 (52.3%) patients; 29 (27.1%) had ≥1 tender and/or swollen joints and 49 (45.8%) ≥1 tender entheses. Small peripheral joints were predominantly affected. US found inflammation in ≥1 joint or enthesis in 52 (49.5 %) patients; 29 (27.4 %) had US synovitis in ≥1 joint, while 36 (34%) US enthesitis. Fibromyalgia classification criteria were fulfilled in seven (7.9%) patients. There was no difference in clinical or US findings between patients with UC and CD, nor between patients with active and inactive IBD. CONCLUSION: Half of patients with newly diagnosed IBD had inflammation in their peripheral joints and/or entheses, documented by rheumatological clinical and ultrasound evaluations. This indicates a need for multidisciplinary collaboration to ensure an optimal therapeutic strategy for suppressing inflammation in all disease domains.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38273715

RESUMO

OBJECTIVES: Interventional musculoskeletal ultrasound (MSUS) procedures are routinely performed in rheumatology practice. However, the efficacy and safety of the procedures rely on the competence of the physician, and assessment of skills is crucial. Thus, this study aimed to develop and establish validity evidence for a tool assessing trainees' interventional MSUS skills. METHODS: An expert panel of rheumatologists modified an existing tool for assessing competences in invasive abdominal and thoracic ultrasound procedures. The new tool (the Assessment of Interventional Musculoskeletal Ultrasound Skills (AIMUS) tool) reflects the essential steps in interventional MSUS. To establish validity evidence, physicians with different levels of interventional MSUS experience were enrolled and performed two procedures on a rubber fantom, simulating real patient cases. All performances were video recorded, anonymized, and assessed in random order by two blinded raters using the AIMUS tool. RESULTS: Sixty-five physicians from 21 different countries were included and categorized into groups based on their experience, resulting in 130 videos for analysis. The internal consistency of the tool was excellent, with a Cronbach's alpha of 0.96. The inter-case reliability was good with a Pearson's correlation coefficient (PCC) of 0.74 and the inter-rater reliability was moderate to good (PCC 0.58). The ability to discriminate between different levels of experience was highly significant (p< 0.001). CONCLUSIONS: We have developed and established validity evidence for a new interventional MSUS assessment tool. The tool can be applied in future competency-based educational programs, provide structured feedback to trainees in daily clinical practice, and ensure end-of-training competence.

11.
Rheumatology (Oxford) ; 63(3): 765-771, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37307078

RESUMO

OBJECTIVES: Musculoskeletal ultrasound (MSUS) is increasingly used by rheumatologists in daily clinical practice. However, MSUS is only valuable in trained hands, and assessment of trainee competences is therefore essential before independent practice. Thus, this study aimed to establish validity evidence for the EULAR and the Objective Structured Assessment of Ultrasound Skills (OSAUS) tools used for assessing MSUS competences. METHODS: Thirty physicians with different levels of MSUS experience (novices, intermediates, and experienced) performed four MSUS examinations of different joint areas on the same rheumatoid arthritis patient. All examinations were video recorded (n = 120), anonymized, and subsequently assessed in random order by two blinded raters using first the OSAUS assessment tool followed by the EULAR tool 1 month after. RESULTS: The inter-rater reliability between the two raters was high for both the OSAUS and EULAR tools, with a Pearson correlation coefficient (PCC) of 0.807 and 0.848, respectively. Both tools demonstrated excellent inter-case reliability, with a Cronbach's alpha of 0.970 for OSAUS and 0.964 for EULAR. Furthermore, there was a strong linear correlation between the OSAUS and the EULAR performance scores and the participants' experience levels (R2 = 0.897 and R2 = 0.868, respectively) and a significant discrimination between different MSUS experience levels (P < 0.001 for both). CONCLUSIONS: MSUS operator competences can be assessed reliably and valid using either the OSAUS or the EULAR assessment tool, thereby allowing a uniform competency-based MSUS education in the future. Although both tools demonstrated high inter-rater reliability, the EULAR tool was superior to OSAUS. TRIAL REGISTRATION: ClinicalTrials.gov, http://clinicaltrials.gov, NCT05256355.


Assuntos
Artrite Reumatoide , Humanos , Reprodutibilidade dos Testes , Correlação de Dados , Mãos , Exame Físico
12.
J Rheumatol ; 51(3): 263-269, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37914219

RESUMO

OBJECTIVE: To assess the construct validity of the novel Outcome Measures in Rheumatology (OMERACT) ultrasound (US) semiquantitative scoring system for morphological lesions in major salivary glands by comparing it with magnetic resonance imaging (MRI) and unstimulated whole salivary flow rates (U-WSFRs) in patients with primary Sjögren syndrome (pSS). METHODS: Nine sonographers applied the OMERACT 0-3 grayscale scoring system for parotid (PGs) and submandibular glands (SMGs) in 11 patients with pSS who also had MRIs performed. These were evaluated by 2 radiologists using a semiquantitative 0-3 scoring system for morphological lesions. The agreement between US and MRI and the association between U-WSFRs and imaging structural lesions was determined. A score ≥ 2 for both US and MRI was defined as gland pathology. RESULTS: The prevalence of US morphological lesions in 11 patients with a score ≥ 2 was 58% for PGs and 76% for SMGs, and 46% and 41% for PGs and SMGs, respectively, for MRI. The agreement between OMERACT US scores and MRI scores was 73-91% (median 82%) in the right PG and 73-91% (median 91%) in the left PG, 55-91% (median 55%) in the right SMG and 55-82% (median 55%) in the left SMG. When relations between the presence of hyposalivation and an US score ≥ 2 were examined, agreement was 91-100% (median 83%) in both PGs and 55-91% (median 67%) in both SMGs. CONCLUSION: There is moderate to strong agreement between the OMERACT US and MRI scores for major salivary glands in patients with pSS. Similar agreement ratios were observed between the higher OMERACT US scores and presence of hyposalivation.


Assuntos
Síndrome de Sjogren , Xerostomia , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia , Xerostomia/diagnóstico por imagem , Imageamento por Ressonância Magnética
13.
Ocul Surf ; 31: 1-8, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38049032

RESUMO

PURPOSE: This double-blinded randomized clinical trial aimed to evaluate the efficacy of injecting allogeneic adipose-derived mesenchymal stem cells (ASCs) into the lacrimal gland (LG) for the treatment of dry eye disease (DED) secondary to Sjögren's syndrome (SS). METHODS: Fifty-four participants with severe DED secondary to SS were included and allocated to either ASCs (n = 20), vehicle (n = 20), or a non-randomized observation group (n = 14). The intervention groups received a single injection of either ASCs or an active comparator (vehicle, Cryostor® CS10) into the LG in one eye, while the observation group received lubricating eye drops only. The primary outcome measure was changes in Ocular Surface Disease Index (OSDI) score and secondary outcome measures were non-invasive tear break-up time, tear meniscus height, Schirmer's test, and Oxford score within a 12-month follow-up. RESULTS: A significant reduction in OSDI score was observed in the ASCs and vehicle groups compared to the observation group. In addition, the ASCs group demonstrated a significant increase in non-invasive tear break-up time compared to the vehicle group at the 4-week follow-up and to the observation group at the 12-month follow-up. A significant improvement in ocular surface staining, tear osmolarity, and Schirmer test score from baseline was also observed in the ASCs group; however, these changes were not significant compared to the other groups. CONCLUSION: Improvement of subjective and objective signs and symptoms of DED was observed in both intervention groups following injection into the LG compared to the observation group. Future studies should investigate the mode-of-action of both injection treatments.


Assuntos
Síndromes do Olho Seco , Transplante de Células-Tronco Hematopoéticas , Transplante de Células-Tronco Mesenquimais , Síndrome de Sjogren , Humanos , Síndrome de Sjogren/complicações , Síndrome de Sjogren/terapia , Síndrome de Sjogren/diagnóstico , Síndromes do Olho Seco/etiologia , Síndromes do Olho Seco/terapia , Síndromes do Olho Seco/diagnóstico , Lágrimas/metabolismo
15.
Clin Rheumatol ; 42(12): 3275-3281, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37553551

RESUMO

The objective of this pilot study was to assess the impact of a salivary gland ultrasound (SGUS) atlas for scoring parenchymal changes in Sjögren's syndrome by assessing the reliability of the scoring system (0-3), without and with the use of the SGUS atlas. Ten participants with varying experience in SGUS contributed to the reliability exercise. Thirty SGUS images of the submandibular and parotid gland with abnormalities ranging from 0 to 3 were scored using the written definitions of the OMERACT SGUS scoring system and using the SGUS atlas based on the OMERACT scoring system. For intra-reader reliability, two rounds were performed without and with the atlas-in the 2nd round the 30 images were rearranged in random order by a physician not included in the scoring. Inter-reader reliability was also determined in both rounds. Without using the atlas, the SGUS OMERACT scoring system showed fair inter-reader reliability in round 1 (mean kappa 0.36; range 0.06-0.69) and moderate intra-reader reliability (mean kappa 0.55; range 0.28-0.81). With the atlas, inter-reader reliability improved in round 1 to moderate (mean kappa 0.52; range 0.31-0.77) and intra-reader reliability to good (mean kappa 0.69; range 0.46-0.86). Higher intra-reader reliability was noted in participants with previous SGUS experience. The SGUS atlas increased both intra- and inter-reader reliability for scoring gland pathology in participants with varying SGUS experience suggesting a possible future role in clinical practice and trials. Key Points • Ultrasonography can detect parenchymal changes in salivary glands in patients with Sjögren's disease. • An ultrasound atlas may improve reliability of scoring parenchymal changes in salivary glands.


Assuntos
Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Projetos Piloto , Reprodutibilidade dos Testes , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia/métodos
16.
Best Pract Res Clin Rheumatol ; 37(1): 101837, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-37258318

RESUMO

This paper addresses how to perform an ultrasound assessment of the salivary and lacrimal glands, how to identify pathological changes, and how to score disease activity, focusing on the use for primary Sjögren's syndrome (pSS). It addresses the role of salivary gland ultrasound for diagnosing and management of patients with pSS and touches upon the use for differential diagnosis, including how and when to perform ultrasound-guided biopsies and injections.


Assuntos
Aparelho Lacrimal , Síndrome de Sjogren , Humanos , Síndrome de Sjogren/diagnóstico por imagem , Aparelho Lacrimal/diagnóstico por imagem , Aparelho Lacrimal/patologia , Glândulas Salivares/diagnóstico por imagem , Ultrassonografia , Diagnóstico Diferencial
17.
Rheumatology (Oxford) ; 62(11): 3547-3554, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-36943374

RESUMO

OBJECTIVES: To examine the effect of pre-course e-learning on residents' practical performance in musculoskeletal ultrasound (MSUS). METHODS: This was a multicentre, randomized controlled study following the Consolidated Standards of Reporting Trials (CONSORT) statement. Residents with no or little MSUS experience were randomized to either an e-learning group or a traditional group. One week before a 2-day face-to-face MSUS course, the e-learning group received access to an interactive platform consisting of online lectures, assignments, and practical instruction videos aligned with the content of the course. The traditional group only received standard pre-course information (program, venue, and time). All participants performed a pre- and post-course practical MSUS examination and were assessed by two individual raters, blinded to the group allocation, using the validated Objective Structured Assessment of Ultrasound Skills (OSAUS) tool. RESULTS: Twenty-eight participants completed the study. There were no statistically significant differences in the pre- or post-course practical MSUS performance between the e-learning group and the traditional group; the mean pre-course OSAUS score (s.d.) in the -learning group was 5.4 (3.7) compared with 5.2 (2.4) in the traditional group (P = 0.8), whereas the post-course OSAUS score in the e-learning group was 11.1 (2.8) compared with 10.9 (2.4) in the traditional group (P = 0.8). There was a significant difference between the mean pre- and post-course scores (5.74 points, P < 0.001). The OSAUS assessment tool demonstrated good inter-rater reliability (intra-class correlation = 0.84). CONCLUSION: We found no significant impact of pre-course e-learning on novices' acquisition of practical MSUS skills. Hands-on training is of the utmost importance and improves MSUS performance significantly. The OSAUS assessment tool is an applicable tool with high interrater reliability. TRIAL REGISTRATION: https://clinicaltrials.gov/ NCT04959162.


Assuntos
Instrução por Computador , Humanos , Reprodutibilidade dos Testes , Ultrassonografia , Competência Clínica
18.
Front Med (Lausanne) ; 10: 1131362, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36968827

RESUMO

Objectives: To identify the prevalence of calcium pyrophosphate crystal deposition (CPPD) using ultrasound and conventional radiology at peripheral joints in patients with suspected or definite CPPD. Methods: A systematic literature search was performed in PubMed and Embase using pre-defined search strategies from inception to April 2021 to identify studies that evaluated conventional radiology and ultrasound in detecting CPPD at peripheral joints, including definite or suspected CPPD [Research question 1 (RQ1) and Research Question 2 (RQ2), respectively]. For the meta-analysis, the first, second, and third sub-analysis included studies with the knee, and knee or wrist as the index joint for CPPD (without restrictions on the reference standard) and synovial fluid analysis or histology as a reference standard (without restrictions on the index joint), respectively. Results: One-thousand eight hundred and twenty-seven manuscripts were identified, of which 94 articles were finally included. Twenty-two and seventy-two papers were included in RQ1 and RQ2, respectively. The knee had the highest prevalence for RQ1 and RQ2 by both conventional radiology and ultrasound, followed by the wrist with the highest prevalence for RQ1. The hand had the lowest CPPD prevalence. The third sub-analysis showed a higher CPPD prevalence on ultrasound than conventional radiology at the knee (only data available). Conclusion: Among all peripheral joints, the knees and wrists could be regarded as the target joints for CPPD detection by imaging. Furthermore, ultrasound seems to detect a higher number of calcium pyrophosphate deposits than conventional radiology, even when using a more restrictive reference standard.

19.
Life (Basel) ; 13(3)2023 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-36983848

RESUMO

Giant cell arteritis (GCA) is an ophthalmological emergency that can be difficult to diagnose and prompt treatment is vital. We investigated the sequential diagnostic value for patients with suspected GCA using three biochemical measures as they arrive to the clinician: first, platelet count, then C-reactive protein (CRP), and lastly, erythrocyte sedimentation rate (ESR). This retrospective cross-sectional study of consecutive patients with suspected GCA investigated platelet count, CRP, and ESR using diagnostic test accuracy statistics and odds ratios (ORs) in a sequential fashion. The diagnosis was established by experts at follow-up, considering clinical findings and tests including temporal artery biopsy. A total of 94 patients were included, of which 37 (40%) were diagnosed with GCA. Compared with those without GCA, patients with GCA had a higher platelet count (p < 0.001), CRP (p < 0.001), and ESR (p < 0.001). Platelet count demonstrated a low sensitivity (38%) and high specificity (88%); CRP, a high sensitivity (86%) and low specificity (56%); routine ESR, a high sensitivity (89%) and low specificity (47%); and age-adjusted ESR, a moderate sensitivity (65%) and moderate specificity (65%). Sequential analysis revealed that ESR did not provide additional value in evaluating risk of GCA. Initial biochemical evaluation can be based on platelet count and CRP, without waiting for ESR, which allows faster initial decision-making in GCA.

20.
J Ocul Pharmacol Ther ; 39(4): 275-278, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36944128

RESUMO

Purpose: To develop a method of injecting a volume up to 50% of the lacrimal gland (LG) volume while minimizing patient discomfort and maximizing accurate drug delivery. Herein we describe a series of ultrasound (US)-guided transcutaneous injections in the LG and discuss the safety and feasibility of this technique. Methods: Ultrasonography was performed in 40 patients with aqueous deficient dry eye disease using a GE Logic E10 (Milwaukee, Wisconsin, USA) US machine with a 6-24 MHz transducer. US was performed by 2 medical experts in ultrasonography. We recorded the injection and observed an enlargement of the LG ensuring delivery within the LG before the needle was removed. Assessment of injection-related adverse event was performed immediately after the injection. Results: The position of the injection needle within the LG was documented in all 40 patients. Injection of the stem cells and vehicle (N = 20) or solely vehicle (N = 20) led to an enlargement of the glandular structures in all cases. No serious adverse reactions related to the injections were observed. Conclusion: US-guided injection into the LG enables injection on a closed eye causing minimum patient discomfort and maximum certainty of accurate drug delivery. US can provide real-time images and may be used to safely guide the needle ensuring correct placement and injection within the gland capsule. This reduces the risk of injury to the eye and adjacent structures and makes a precise transcutaneous injection possible. Clinical Trial Registration number: NCT04615455.


Assuntos
Síndromes do Olho Seco , Aparelho Lacrimal , Humanos , Ultrassonografia , Síndromes do Olho Seco/tratamento farmacológico , Células-Tronco , Ultrassonografia de Intervenção/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...