1.
Ann Vasc Dis ; 17(1): 21-24, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38628936

RESUMO

Objective: Cyanoacrylate closure (CAC) is a minimally invasive technique for the treatment of varicose veins. A recent paper reported serious adverse events (AEs) associated with this use. This triggered an urgent survey to determine the incidence of AEs in Japan. Methods: The CAC-AE survey was sent to all 1,030 institutions authorized for CAC treatments. Cases performed between January 2020 and October 2023 were surveyed. Data on serious AEs and mortality were collected. Results: There were 623 surveys returned. There were 16 cases of proximal deep vein thrombosis, 3 cases of pulmonary embolism (PE), and 0 cases of stroke. Deep vein occlusion due to cyanoacrylate extension was observed in 1 case. Vein resection due to infection was observed in 4 cases. There were 299 cases of localized phlebitis and/or allergic reactions requiring steroid administration. Systemic allergic reactions requiring steroid administration were observed in 66 cases. There was no anaphylaxis associated with cyanoacrylate. There was one postoperative death from PE. Conclusion: This report's intent is to provide real world data on serious AEs following CAC from Japan given current concern over these events. An extensive report investigation of individual complications with analysis including causality will be provided following a full investigation separately.

2.
Kyobu Geka ; 75(12): 999-1002, 2022 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-36299152

RESUMO

The patient was a 60-year-old woman who underwent thoracoabdominal aorta replacement for type B aortic dissection three years ago and aortic root replacement and total aortic arch replacement due to asymptomatic type A aortic dissection two years previously. Her clinical course was uneventful until follow-up computed tomography (CT) disclosed anastomotic insufficiency in the innominate artery and left main coronary artery stenosis owing to hematoma. Emergent percutaneous coronary intervention and stent graft insertion into the innominate artery were performed successfully. Seven months later, however, CT scan revealed a perforation in the posterior wall of the artificial graft damaged by the edge of the implanted stent graft. The patient underwent open surgery and perforation of artificial graft was sutured and redundant stent graft edge was resected. Artificial graft damage by stent graft placement is rare to date, but may increase in the future in accordance with broader application of endovascular treatment.


Assuntos
Aneurisma da Aorta Torácica , Dissecção Aórtica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Feminino , Pessoa de Meia-Idade , Prótese Vascular , Tronco Braquiocefálico/diagnóstico por imagem , Tronco Braquiocefálico/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Stents , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia
3.
Circ J ; 84(10): 1764-1770, 2020 09 25.
Artigo em Inglês | MEDLINE | ID: mdl-32759542

RESUMO

BACKGROUND: Limited data is available on the use of a polyester graft limb with a helical stent configuration deployed in the external iliac artery (EIA) during endovascular aneurysm repair (EVAR), so we prospectively analyzed the efficacy of the Zenith Spiral-Z limb deployed in the EIA.Methods and Results:Patients undergoing EVAR using a Zenith stent-graft and Spiral-Z limb deployed in the EIA were prospectively registered in 24 Japanese institutions from June 2017 to November 2017. In total, 65 patients (74 limbs) (mean age: 77.1±8.0 years, 87.7% men, mean abdominal aortic aneurysm (AAA) diameter: 51.9±7.2 mm, mean iliac artery aneurysm (IAA) diameter: 38.3±10.0 mm) were registered and followed up. The most common reason for deployment in the EIA was a common IAA (43 limbs, 58.1%), and 8 limbs (10.8%) had a bare nitinol stent placed at the Spiral-Z limb. A total of 61 patients (70 limbs) completed a 24-month follow-up. There were 2 Spiral-Z limb stenoses and 1 occlusion, leading to a primary patency of 95.5% and a secondary patency of 100%, at 24 months. Buttock claudication occurred in 24.3% of the limbs treated at 1 month but decreased to 4.3% at 24 months. CONCLUSIONS: Our multicenter prospective study showed that Spiral-Z limb deployed in the EIA was associated with satisfactory results and seems to be a durable option, even in the era of iliac branch devices.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Estenose da Valva Aórtica/etiologia , Implante de Prótese Vascular/métodos , Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/métodos , Oclusão de Enxerto Vascular/etiologia , Artéria Ilíaca/cirurgia , Desenho de Prótese , Stents/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/epidemiologia , Humanos , Artéria Ilíaca/patologia , Japão/epidemiologia , Masculino , Estudos Prospectivos , Fatores de Risco , Resultado do Tratamento
4.
Circ Rep ; 2(10): 635-636, 2020 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-33693188
5.
Gen Thorac Cardiovasc Surg ; 66(12): 744-747, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29536235

RESUMO

In almost every type of artificial valve, structural failure has been described. We are reporting on a case of a sudden leaflet escape of an Edwards TEKNA mitral valve prosthesis 12 years after implantation. The patient had a sudden onset of dyspnea and severe pulmonary edema with subsequent cardiogenic shock. An emergency mitral replacement was successfully performed. A multi-detector computed tomography scanning and three-dimensional imaging showed two fragments that had embolized in the terminal aorta and the left common iliac artery. The patient presented visual field abnormality, and postoperative head computed tomography showed watershed cerebral infarction. The escaped leaflet that fractured transversely was removed, following the patient's recovery, during cardiac surgery.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Falha de Prótese , Embolia , Embolização Terapêutica , Feminino , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores , Implantação de Prótese , Edema Pulmonar/diagnóstico , Choque Cardiogênico/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...